Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 CrAccepted-AOC C 51 SECTOR DELTA I GREATER NOIDA | GREATER NOIDA | ₹1.2 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.3 CrRejected-Finance | ₹1.3 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹1.4 CrRejected-Finance 511 KRISHNA NAGAR BAGU BYE PASS ROAD VIJAY NAGAR GHAZIABAD U P | GHAZIABAD | U P | ₹1.4 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹1.5 Cr
EMD Value
₹3.0 L
Closing Date
31 Dec 2025, 5:00 pmClosed
SM_TENDER CELL
GNIDA OFFICE
Operation of electric substation, DG Set, Indoor Stadium, Tennis Complex, Cricket Flood light, Food and toilet block lights and Maintenance of DG Set and Substation at Shaheed Vijay Singh Pathik Sports Complex, Greater Noida.
2025_GNIDA_1100164_25
SM/(E-TENDER CELL)/2025/683 DATED-17.12.2025
Open Tender
Electrical Works
1095 days
GREATER NOIDA
REFER TENDER DOCUMENT
5 documents required · 5 mandatory
₹2,690
₹3.0 L
7 Apr 2026
22 Dec 2025
2 Jan 2026
22 Dec 2025
31 Dec 2025
22 Dec 2025
Maintenance of Indoor floor mounted totally enclosed including all loading unloading. testing and comisioning caringfrom site to workshop & back to site etc. coimpartmentalized, extendable type PCC/PMCC/MCC Cubicle Panel Board having 36 MVA, 50 kA breaking capacity of suitable size fabricated from CRCA steel of 2 mm thick for frame work, enclosure and doors, 3 mm thick for gland plates with stiffeners wherever required, having vibration free structure Chemically treated with seven tank process before painting for surface treatment and powder coated, with suitable electrolytic grade high conductivity PVC sleeved aluminium (E91-E) busbars shall be sized for maximum 0.8 A/mm2 current density, extensible type. complete in all respect asper direction of E/I. Make L&T, ABB, Schneider
Air Circuit Breaker (ACB)
Supply and Replacement Air circuit Breaker (3200 amp) GNIDA Approved Rate
Supply and Replacement Air circuit Breaker (1600 amp) GNIDA Approved Rate
Supply and Replacement Air circuit Breaker(1000 amp) GNIDA Approved Rate
Supply and Replacement 530 amp GNIDA Approved Rate
Supply and Replacement 400 amp GNIDA Approved Rate
Supply and Replacement 315 amp GNIDA Approved Rate
Supply and Replacement 200 amp GNIDA Approved Rate
Fuses & MCB
Protective Relay GNIDA Approved Rate
Electronic Accessories GNIDA Approved Rate
Preventive Maintenance (quarterly & as when required) GNIDA Approved Rate
Maintenance of 33 Kv & 11 Kv 1000 MVA, 400 A, Indoor, drawout type Three HT Vaccum Circuit Breaker Panel (1 Incomer + 2 outgoing) with CT and PT including all loading -unloading, testing and commisioning cashing from site to workshop & back to site etc. PT appropriate rating for metering and protection along with required Indicating lamps, protection relay and Indicating meters, etc. complete in all respects as per IS, Specification including loading and unloading. complete in all respect as per direction of E/I.
HT Indoor Switch gear Panel - 11 KV GNIDA Approved Rate
Supply and Replacement CT/PT GNIDA Approved Rate
Supply and Replacement HT Fuse &MCB GNIDA Approved Rate
Supply and Replacement Cable joint kit GNIDA Approved Rate
Supply and Replacement Protective relay GNIDA Approved Rate
Preventive Maintenance (quarterly & as when required) GNIDA Approved Rate
S&F of 200 Amp. Four pole mouled case type on load change over switch with enclosure includind the cost of labour, T & P and material required for proper completion of the work as per direction and satisfaction of Engineer in charge. UPPWD-2018/379A
Maintenance of diesel generator with engine, alternator & DG Controller Set, including all loading unloading, testing and commissioning caring from site to workshop & back to site etc. complete in all respect as per direction of E/I.
1000 KVA (Cummins) GNIDA Approved Rate
Filter Lubricating Oil GNIDA Approved Rate
Supply and Replacement Element Air Cleaner GNIDA Approved Rate
Radiator GNIDA Approved Rate
Supply and Replacement Belt GNIDA Approved Rate
Fuel Filter GNIDA Approved Rate
Supply and Replacement Gas Kit Cylinder GNIDA Approved Rate
Supply and Replacement Battery pulse lite GNIDA Approved Rate
Indicator Restriction GNIDA Approved Rate
Supply and Replacement Electronic Accessories GNIDA Approved Rate
Preventive Maintenance (quarterly & as when required) GNIDA Approved Rate
Separator Fuel Water GNIDA Approved Rate
Operation of HT Panel, isolator panel, Main LT Panel Sub panel, internal lighting & external lighting panel transformer, Diesel Generator 1. Operation of DG Set during power failure. 2. Change over during power failure. 3. Taking of all running load reading every 2 hours 4. Maintain of DG running record.
Work of scope of Transformer: Visual inspection of transformer 1. Checking of relays of transformer 2. Checking of cooling systems 3. Checking of oil level.
Scope of work of H.T. /L.T. panel: Visual inspection of breaker 1.Through cleaning of breaker 2.Lubrication of moving parts of drive mechanism. 3.Lubrication of closing & tripping mechanism 4. Checking of Gear box assembly 5.Checking of Test service auxiliary switch operation 6.Checking of tripping mechanism operation 7.Checking of breaker auxiliary switch operation. 8.Sprin'g charging limit switch operation. 9.Checking of front drive key operation in test & service position. 10.Checking of trip coil resistance 11.Checking of closing coil resistance.
Operation of light & H.V.A.C. 1.Substation 2.Flood light 3.Indoor stadium - Light & AC operation 4. Tennis complex - Light & AC Operation 5.Technical Supervisor - 01 No. 6.D.G. Operator / Electrician - 06 No. 7.Helper-01 No. GNIDA Approved Rate
Total AMC period 01 Year)
Grand Total (AMC period 03 Year) 5005669.70X3=15017009.10 Year
Labour Cess and GST will be paid extra as per govt. orders
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
techsummary_2027279.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.20 MB
Tendernotice_2.pdf
PDF • 0.17 MB
PreQ_Oper_Elec_Substat_DG_Complex_Cric_Flood_Vijay_Pathak.pdf
Tender Documents • 1.51 MB
687.pdf
Additional Documents • 0.17 MB
BOQ_2027279.xls
BOQ • 0.24 MB