| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹8.1 LAdmitted-Finance 975 E LOHIYA GALI NO 4 BABARPUR DELHI 110032 | DELHI | SHAHDARA | DELHI | 110032 | L1 | Admitted-Finance | ||
| 2 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | ||
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹9.3 L
EMD Value
₹18,557
Closing Date
4 Jun 2026, 11:00 amClosed
Executive Engineer (E),
Executive Engineer (E),PWD NES/M-251, LM Bund Road, Ramesh Park, Delhi
RMO Electrical and Mechanical services of at SDM Court, Seelampur (SH- Providing and Fixing of Air Conditioners, Industrial Air Coolers, RO and Water Coolers at SDM Court and VERC Center.)
2026_PWD_292180_1
24/EE(E)/PWD NES ED/2026-27
Open Tender
Electrical Works
Percentage
30 days
under M-2511
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹18,557
Yes
8 Jun 2026
28 May 2026
4 Jun 2026
28 May 2026
4 Jun 2026
28 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying, Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180- 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply: Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS: 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). 1.5 TR with 5 Star BEE Rating (Inverter type) | |||||
| 2Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. | |||||
| 3Supplying and fixing of copper wounded Automatic Digital Voltage stabilizer of 5 KVA capacity single phase having input voltage range 150-270 voltage with over & under voltage protection and time delay etc. complete as required. | |||||
| 4Supply and installation of MS (Mild Steel) powder-coated stand suitable for supporting 1.0 / 1.5 / 2.0 Ton split AC outdoor units, wall/floor mounted type, including fasteners, clamps, rubber pads, and necessary accessories for proper fixing etc. complete as required. | |||||
| 5Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. | |||||
| 5.1 | 3 x 6 sq. mm | - | Mtr | - | - |
| 6Supplying and installation of 1/2" and 1/4" copper pipe with insulation, copper cable and flair nuts i/c brazing, testing, commissioning etc. complete as reqd. | |||||
| 7Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required | |||||
| 7.1 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire | - | Mtr | - | - |
| 8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required | |||||
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 3.18 MB
BOQ_387893.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .