| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.7 LAccepted-AOC 101 1ST FLOOR JASOL RESIDENCY 14TH CROSS KANAKANAGAR R T NAGAR POST BANGALORE 560032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹31.9 L+₹2.2 L (7.29%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹32.5 L+₹2.7 L (9.11%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹34.2 L+₹4.5 L (15.0%)Rejected-AOC NO157 14 13TH B MAIN ROAD 1ST STAGE 1ST PHASE GOKULA BANGALORE 560054 | BENGALURU URBAN | KARNATAKA | 560054 | L4 | Rejected-AOC Rejected | |
| 5 | L5₹37.2 L+₹7.4 L (25.0%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
₹36.5 L
EMD Value
₹73,000
Closing Date
5 Sept 2020, 6:00 pmClosed
BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
PROVN OF DEFICIENT CEILING FANS AND EXHAUST FANS IN OTM ACCN AT NEW TB III OLD TB III ORs QTRS AT ADMC LED SECURITY LIGHT FROM SPG GATE TO NORTH GATE OF TB I OTM ACCN OF 15 DOGRA AND CERTAIN MINOR WORKS UNDER GE NORTH BANGALORE
2020_MES_366664_1
8463
Open Tender
Miscellaneous Works
Item Rate
120 days
BANGALORE
Class D category b(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹73,000
Yes
11 Sept 2020
5 Aug 2020
7 Sept 2020
5 Aug 2020
5 Sept 2020
19 Aug 2020
5 Aug 2020 - 18 Aug 2020
Amount
Energy saving ceiling fans, 230 Volts, 32 Watts, single pole, 1200 mm sweep, high speed of approved colour with remote control and two years warranty certificate from the manufacturers, with latest BEE five star rating and BLDC technology all as per Havells Model No :- Efficiencia Neo (BLDC 32W)/ Usha Model No. Energia 32(BLDC) 5 STAR or techno commercially equivalent models specified in PS complete with down rod and GI hook with welding work, wire connections from ceiling rose to ceiling fans, with complete accessories including writing of MES No with unit name on ceiling fans using approved stencil with synthetic enamal paint complete all as specified and as directed.
Point wiring complete with 1.5 sq.mm single core PVC insulated unsheathed, 1100 volts grade with multi stranded copper conductor cable conforming to IS 694 drawn through and including non-metalic rigid PVC conduit mdium grade with all accessories surface type run on walls / ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 1.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed for one fan point controlled by one switch/regulator.
Stepped type electronic fan regulator flush type, 230 Volts, 1000 Watt all as specified and as directed.
Hot dip galvanised octgaonal pole of 8 mtr height made out of 3 mm thick HT sheet steel plate along with 220 x220 x16mm base plate, top dia 70 mm, bottom dia 130 mm including taking down old unserviceable pole erecting all as directed including providing following accessories :- (a) M20x600 mm long type foundation bolts with template. (b) 1500 mm single arm decorative type bracket with welded along with the pole. (c) Connector for three phase and neutral fixed inside the cable termination box of octagonal pole for loop in and loop out facility of UG cable.
LED street light fittings, 90 Watts with pressure die cast housing with toughned glass, IP-66 protection, 90 watt LED lamp etc., complete with accessories all as per Bajaj Cat No. BRTFG 90 W or techno commercially equivalent makes specified in PS complete all as as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in deep for cable and getting in hard/dense soil complete all as specified and as directed by Engineer-in-charge.
Returning, filling in excavated soil, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in hard / dense soil etc complete as specified as directed.
Removing excavated surplus soil to a distance exceeding 250m but not exceeding 500m and depositing where directed at a level not exceeding 1.5m above the starting point all as directed.
Sand cushioning in layers for cables in trenches / ducts for cable including consolidation complete all as specified and directed. NOTE: Punned thickness will be measured for payment purpose.
Bricks, sub class 'B' of old size 230 mm x 115 mm x 75 mm laid in trenches for cable protection all as specified and directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 10 sq.mm, 4 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
XLPE insulated, galvanised steel strip or wire armoured and PVC bedded, heavy duty, LT cable 25 sq.mm, 3.5 core, 1100 volts grade with multi stranded aluminium conductor, including cable glands, cable lugs etc., to suit the cable size, laid in trenches, or fixed along with the poles, bare or through GI pipe, laid under floors / road etc., fixed / concealed in walls / encased in GI pipe etc., jointing and testing complete all as specified and as directed.
Wiring with three core PVC insulated, sheathed, cable 1.5 sq.mm with multi stranded copper conductor, 1100 volts grade, conforming to IS :694, including drawn through the octagonal pole and connection to light fitting and MCBs complete all as specified and as directed.
MCB SP 6 Amps 'C' curve fixed inside the octagonal pole including electrical connections all as specified and as directed.
Plain cement concrete (1:4:8), type D2, using 40 mm graded stone aggregate as in foundation of poles, stay assembly etc., complete all as specified and as directed.
Plain cement concrete (1:3:6), type C1, using 20 mm graded stone aggregate as in for coping including necessary form work complete all as specified and as directed.
Earthing complete with galvanised steel plate electrode 600mm x 600mm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge not less than 1.5 m below ground level connected to earth lead by GI wire 4 mm dia by means of bolts nuts, check nuts, washers made out of galvanised iron connected to main switch all as shown in elect plate No 3 of MES SSR Part -I includingn excavation and earth work in any type of soil,funnel, 20 mm dia light grade GI watering pipe with chamber of PCC 1:3:6 type C1 40mm thick of size 450mm x450mm (1:2:4) type B1 for cover slab reinforced with 8mm dia TMT bars 10cm c/c both ways and with 6mm MS hook etc complete all as specified including testing on completion all as specified and directed.
Time lite distribution box consisting of digital time switch of 230 Volts 32 Amps, 3 pole contactor, MCB TPN 40 Amps internally pre wired with suitable size of wires and connectors fitted on the pole with GI clamps of size 20 x5 mm fitted with nut, bolts and washers including connecting in and out connections etc all as specified and as directed.
Exhaust fan 230Volts, SP, 380 mm sweep,1400 RPM metalic body, high speed, heavy duty complete with Louvers, clamps with screws nut and bolts, including making core cutting, wire connections from ceiling rose to exhaust fan complete with accessories all as per Usha Cat No. S.PH TURBO HDEF 1400RPM ISI or techno commercially equivalent makes specified in PS including writing of MES No with Unit Name on Exhaust fans using stencil with synthetic enamel paint all as specified and as directed.
Moulded (FRP) junction box with IP-65 protection of size 250 x 200 x 100mm (in side), hinged type with 32 Amps, 4 way, heavy duty terminal block with 6 Amps MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as specified and as directed.
Security light fitting with 1x60 Watt LED, high power LED 5700 K suitable for primary roads, pressure die cast aluminium IP-66 protection, peanut lens to ensure uniform distribution with LED street lights all as per Wipro, Cat No.:- LR02-671-XXX-57-XX or techno commercially equivalent makes specified in PS all as specified and as directed.
Sub main wiring / circuit wiring complete with two runs of 1.5 sq.mm single core PVC insulated FRLS multistranded copper conductor cable 1100 volts grade, with one run of 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing non metallic rigid PVC conduit of suitable size, medium grade and conduit accessories fixed on poles / walls with suitable sizes of clamps and connecting up all as specified and as directed. NOTE :- Two runs of cable, one run of earth wire and one run of conduit shall be measured as one unit for payment purpose.
Bracket made out of GI tubing light grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm, nuts, bolts, washers etc., applying two coats of aluminum paint over a coat of red oxide primer before fixing complete all as specified and as directed.
Reverse Osmosis filter plant of delivery capacity 25 Litres per hour with stainless steel storage tank of 100 Litre capacity, including stainless steel bib tap of 15mm dia fitted with tank complete all as specified and as directed.
Galvanised iron pipe of 15 mm dia, medium grade, laid in trenches, floors / fixed to wall with all fittings such as socket, bends, elbow, union etc., complete all as specified and as directed.
Stop valves, 15mm bore fancy type, cast copper alloy chromium plated, screwed down, high pressure, with cructh or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and as directed.
Point wiring complete with 2.5 sq.mm single core PVC insulated unsheathed, 1100 volts grade with multi stranded copper conductor conforming to IS 694 drawn through and including non-metalic rigid PVC conduit medium grade with all accessories surface type/ concealed run on walls/ ceiling including MS terminal boxes fabricated with 1.6 mm thick MS sheet surface mounted/ concealed on walls with plastic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket outlets, fan regulators etc., including provision of 2.5 sq.mm PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. Note for Item No 1.02 and 1.27 :- (i) The earth wire for the points in the same circuit can be looped from point to point. (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring
Switch socket combination 2 in 1, 3 pin and 2 pin, 5 and 15 Amps flush type, universal complete all as specified and as directed
Refrigerator, inverter type, double door, 360 Litres capacity BEE four star rated, 230 Volts, AC all as per LG Model No. GLR402JPZN or techno commerically equivalent makes in Samsung / Whirlpool complete all as specified and as directed.
RAMSON TRADERS
B M Electricals
N RAJEGOWDA and CO
kamadhenu Electricals
GS TRADERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .