Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.3 LAccepted-AOC | L1 | Accepted-AOC QUALIFIED | |
| 2 | L2₹10.5 L+₹14,350 (1.39%)Rejected-AOC | L2 | Rejected-AOC QUALIFIED | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹11 L
EMD Value
₹11,000
Closing Date
29 Jun 2020, 3:00 pmClosed
SUPERINTENDING ENGINEER, EUDC-II, GHAZIABAD
33/11 KV Sub-Station, Kala Pathar, Indirapuram, Ghaziabad.
Testing and maintenance AMC work of 11 KV and 33 KV Breaker and Transformers installed at various 33 by 11 KV Sub Stations under EUTD II GZB
2020_PVVNL_484171_1
13/W/2020-21/T-II/EUDC-II/GZB
Open Tender
Electrical Works
Item Rate
365 days
UNDER EUTD II GHAZIABAD
Please refer Tender documents.
2 documents required · 2 mandatory
₹3,540
SUPERINTENDING ENGINEER, EUDC-II, GHAZIABAD
₹11,000
3 Dec 2020
17 Jun 2020
30 Jun 2020
17 Jun 2020
29 Jun 2020
17 Jun 2020
Amount
fo|qr uxjh; forj.k e.My&f}rh;] xkft;kckn ds vUrxZr fo|qr uxjh; ijh{k.k [k.M&f}rh;] xkft;ckn ds dk;Z{ks= esa 33@11 ds0oh0 midsUnzksa ij LFkkfir 11 ds0oh0 ,oa 33 ds0oh0 czsdjksa o ifjorZdksa dh ijh{k.k@vuqj{k.k ¼,0,e0lh0½ dk dk;Z vuqcU/k dh fnukad ls ,d o"kZ rd vks0 ,.M en esa okg~; ,tsUlh ds ek/;e ls djkus dk dk;ZA
Testing of 11 KV VCB and keeping it healthy for 1 year by (a) Checking of closing/Tripping circuit and indication/ Annunciation/ alarms. (b)Testing of CT's for metering and protection. (c) Testing of O/C & E/F relays & replacement of defective relays if required. (d) New wiring in break down conditions. (The control wire with ferrule will be provided by the Contractor the relay would be provided by the utility).
Testing of 33 KV VCB and keeping it healthy for 1 year by (a) Check Electrical closing & Tripping from local and remote and set right the fault (b) Check control panel Indication bulb, O/C & E/F Relay and replacement of relay if required, DC & AC panel, charging Motor and its supply, Kit Kat & MCB. (c) New wiring in break down conditions. (The control wire with ferrule will be provided by the Contractor the relay would be provided by the utility).
Replacement of oil/winding temperature meter. Replacement of defective temperature meter/oil temperature meter including cost of meter as and when required and keeping them in healthy condition for 1 year (Quantity may vary as per site requirement).
Rewiring & Rearrangement of switching PT circuit through relay controlled by 11 KV outgoing VCB at different substation & keeping them in healthy condition for 1 year.
Measuring of specific gravity of cells of 24 Volts Battery charger on weekly basis and topping up of battery water as per requirement & keeping the battery charger in healthy state for 1 year.
NAVEEN ELECTRICALS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .