Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC PLOT NO 1134 1196 MORIVALI VILLAGE TAL AMBARNATH DIST THANE AMBERNATH 421505 | AMBERNATH | THANE | MAHARASHTRA | 421505 | L1 | Accepted-AOC AOC | |
| 2 | L2₹36.9 L+₹5.0 L (15.7%)Rejected-Finance COLABA MUMBAI | L2 | Rejected-Finance Other Than Being Lowest | |
| 3 | L3₹37.5 L+₹5.6 L (17.6%)Rejected-Finance | L3 | Rejected-Finance Other Than Being Lowest | |
| 4 | L4₹37.9 L+₹6.0 L (18.9%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | L4 | Rejected-Finance Other Than Being Lowest | |
| 5 | L5₹39.8 L+₹7.9 L (24.8%)Rejected-Finance COLABA MUMBAI | L5 | Rejected-Finance Other Than Being Lowest |
| Sl No | Description | Qty | Unit | Shree Elevator Engineering Co. L3 | Monarch Enterprises L2 | Veer High Tech Solution L5 | Escon Elevators Pvt Ltd L4 | shakti engineering and electrical works L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door cills, door locks, cabin lights, minor repair of cabin fan,control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked /broken and MS parts,door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement and ensure smooth and safe operation of lifts , fixing of loose rail bracket with necessary masonry work , changing of broken anti skid pvc rubber mat and air freshner at lift cabin, removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces and lift machine and all equipment held in machine room and rust painting at car top and door and allied parts , two coats of painting of gear motor, all MS channels and Control Panels using spray gun ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and , dewatering of lift wells in case of any emergency arise complete all as specified and directed.
Buildings :Boat Pool 01 Nos lift (2000Kg) G+03.Make: Existing make at Bldg . | 11 | Per Month | 10,950 ₹1,20,450 | 10,500 ₹1,15,500 | 11,400 ₹1,25,400 | 11,000 ₹1,21,000 | 8,900 ₹97,900 Lowest |
| 2.00 | Ditto all as per item No 1.00 herein before but 06 PS , (02) Nos lift with collapsble door (408 Kg) (G+05) installed at Reveria bldg. (Total 02 Nos lift). Make : Existing make at Bldg. | 11 | Per Month | 17,400 ₹1,91,400 | 16,500 ₹1,81,500 | 18,200 ₹2,00,200 | 17,800 ₹1,95,800 | 14,240 ₹1,56,640 Lowest |
| 3.00 | All as per item No 1 herein before but for 13 passengers having daul power operated door, automatic levelling device and microprocessor based simplex collective control system to serve G+12 floors installed at Aditi bldg (Total 01 lifts). Make : Existing make at Bldg. | 11 | Per Month | 13,050 ₹1,43,550 | 12,500 ₹1,37,500 | 13,700 ₹1,50,700 | 13,250 ₹1,45,750 | 10,680 ₹1,17,480 Lowest |
| 4.00 | All as per item No 1 herein before but for 13 passengers having daul power operated door, automatic levelling device and microprocessor based simplex collective control system to serve G+12 floors installed at Ahilya bldg (Total 01 lifts). Make : Existing make at Bldg. | 11 | Per Month | 13,050 ₹1,43,550 | 12,500 ₹1,37,500 | 13,700 ₹1,50,700 | 13,250 ₹1,45,750 | 10,680 ₹1,17,480 Lowest |
| 5.00 | All as per item No 1 herein before but for 08 passengers having daul power operated door, automatic levelling device and microprocessor based simplex collective control system to serve G+12 floors installed at Ahilya bldg (Total 02 lifts). Make : Existing make at Bldg. | 11 | Per Month | 20,170 ₹2,21,870 | 20,350 ₹2,23,850 | 20,300 ₹2,23,300 | 20,220 ₹2,22,420 | 17,800 ₹1,95,800 Lowest |
| 6.00 | Dismantling and taking out ARD control system and commissioning and testing of new ARD system including PC cards/ diodes suitable for upto 10 HP motor including wiring with connected item in existing building complete all as specified and directed. | 2 | Each | 1,73,800 ₹3,47,600 | 1,62,300 ₹3,24,600 | 1,82,000 ₹3,64,000 | 1,81,600 ₹3,63,200 | 1,42,400 ₹2,84,800 Lowest |
| 7.00 | Dismantling and taking out all defective batteries from existing ARD and supply and fixing new batteries suitable for ARD including necessary connection like battery terminals of brass and copper lead heavy duty to connect the battery terminal of complete all as specified and directed. | 5 | Each Set of 04 Nos batteries | 11,000 ₹55,000 | 9,500 ₹47,500 Lowest | 13,800 ₹69,000 | 13,620 ₹68,100 | 10,680 ₹53,400 |
| 8.00 | Taking down unserviceable main pulley with complete set Supplying & fixing new main pully with complete set complete all as specified and directed. | 3 | Each Job | 38,500 ₹1,15,500 | 37,975 ₹1,13,925 | 28,000 ₹84,000 Lowest | 39,725 ₹1,19,175 | 31,150 ₹93,450 |
| 9.00 | Dismantling and taking out unserviceable old control panel with control wiring up to mid way junction and Supply and fixing new control panel with multiple integrated micro processor programmable chip based suitable for auto door, consisting of contactors, intergrated mother board & compatible to existing capacity VVVF drive, connectors,assembled in MS Sheet cabinet with lockable hinge door, foot mounted, in powder coated finish, seperate box for breaking resistor and programmed in such a way to operate lift from COP and comprising with variable voltage, variable frequency drive suitable up to 15 HP motor 240 volts 50Hz controlled by pulse with modulation complete with all safety devices such as over current protection, single phase protection etc. including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with 6.0 sq mm copper conductor in PVC insulated, IS Marked etc. including all standard features & fixtures ete all as per IS 14665 all as specified and directed. | 2 | Each | 2,25,600 ₹4,51,200 | 2,44,125 ₹4,88,250 | 2,47,000 ₹4,94,000 | 2,26,500 ₹4,53,000 | 2,00,500 ₹4,01,000 Lowest |
| 10.00 | Disconnecting and taking out defective shaft wiring and providing new shaft wiring in hoist way up to lower limit switch with PVC insulated 16/18 core flat/round type standard copper conductor cable size 1.00/0.75 Sqmm 1100 volts grade with ISI Marked drawing through in upto ground floor in hoist way for control of all floor hall push button assembly ,limit switch, Firemenswitch etc, complete all as specified. | 2 | Job | 46,200 ₹92,400 | 45,570 ₹91,140 | 45,000 ₹90,000 | 47,670 ₹95,340 | 37,000 ₹74,000 Lowest |
Tender Value
₹34.5 L
EMD Value
₹69,000
Closing Date
22 Dec 2025, 6:00 pmClosed
CWE (NW) Mumbai
CWE (NW) Mumbai
REPAIR AND ROUTINE MAINTENANCE OF LIFTS AT ADITI, AHILYA BLDG, NEW SAILER BLOCK BOAT POOL AND REVEIRA BLDG AT OUTLAYING AREA UNDER GE (NW) NOFRA COLABA, MUMBAI
2025_MES_742332_1
8678/CWE(NW)Mumbai/E8
Open Tender
Civil Works
Item Rate
335 days
GE (NW) NOFRA
Class D
Category c(ii)
8 documents required · 8 mandatory
₹500
GE (NW) NOFRA
₹69,000
Yes
14 Feb 2026
2 Dec 2025
24 Dec 2025
2 Dec 2025
22 Dec 2025
17 Dec 2025
2 Dec 2025 - 22 Dec 2025
Amount
Repair/maintenance of lifts including carrying out daily check and periodical services of fully automatic electrical lift with power operated door, simplex collective control system with repair/maintenance of unserviceable damaged parts such as bearings, bushes, all type of guide shoes, headers, hangers, door ropes,door cards,car door sills, landing door cills, door locks, cabin lights, minor repair of cabin fan,control cards, and its contacts, hall push buttons and its spares, connector/links, welding of cracked /broken and MS parts,door safety edge and sensor mechanical safety lock, magnetic lock or contact, car position indicator, and all connected accessories, necessary wiring of hall push button assembly, repair/maintenance of broken COP/LOP buttons and display, including cover, Fire alarm, Firemen button glass, Intercom, alarm/hooters, damaged hand rail, Shaft, light/switches, complete with illuminated push button and direction indicator with LED display with LPT/LPC card of stainless steel inclusive of harness wiring for laminating of push button of each floors and cutting wall making good disturbed surface with masonry work to make with existing surface & cable as per requirement and ensure smooth and safe operation of lifts , fixing of loose rail bracket with necessary masonry work , changing of broken anti skid pvc rubber mat and air freshner at lift cabin, removing old paint by paint removers and cleaning with scrappers, any number of coats, steel surfaces and lift machine and all equipment held in machine room and rust painting at car top and door and allied parts , two coats of painting of gear motor, all MS channels and Control Panels using spray gun ensure safe and smooth functioning of lift and complete maint of car top, binding of loose wire at control panel and , dewatering of lift wells in case of any emergency arise complete all as specified and directed. Buildings :Boat Pool 01 Nos lift (2000Kg) G+03.Make: Existing make at Bldg .
Ditto all as per item No 1.00 herein before but 06 PS , (02) Nos lift with collapsble door (408 Kg) (G+05) installed at Reveria bldg. (Total 02 Nos lift). Make : Existing make at Bldg.
All as per item No 1 herein before but for 13 passengers having daul power operated door, automatic levelling device and microprocessor based simplex collective control system to serve G+12 floors installed at Aditi bldg (Total 01 lifts). Make : Existing make at Bldg.
All as per item No 1 herein before but for 13 passengers having daul power operated door, automatic levelling device and microprocessor based simplex collective control system to serve G+12 floors installed at Ahilya bldg (Total 01 lifts). Make : Existing make at Bldg.
All as per item No 1 herein before but for 08 passengers having daul power operated door, automatic levelling device and microprocessor based simplex collective control system to serve G+12 floors installed at Ahilya bldg (Total 02 lifts). Make : Existing make at Bldg.
Dismantling and taking out ARD control system and commissioning and testing of new ARD system including PC cards/ diodes suitable for upto 10 HP motor including wiring with connected item in existing building complete all as specified and directed.
Dismantling and taking out all defective batteries from existing ARD and supply and fixing new batteries suitable for ARD including necessary connection like battery terminals of brass and copper lead heavy duty to connect the battery terminal of complete all as specified and directed.
Taking down unserviceable main pulley with complete set Supplying & fixing new main pully with complete set complete all as specified and directed.
Dismantling and taking out unserviceable old control panel with control wiring up to mid way junction and Supply and fixing new control panel with multiple integrated micro processor programmable chip based suitable for auto door, consisting of contactors, intergrated mother board & compatible to existing capacity VVVF drive, connectors,assembled in MS Sheet cabinet with lockable hinge door, foot mounted, in powder coated finish, seperate box for breaking resistor and programmed in such a way to operate lift from COP and comprising with variable voltage, variable frequency drive suitable up to 15 HP motor 240 volts 50Hz controlled by pulse with modulation complete with all safety devices such as over current protection, single phase protection etc. including proper connection with proper lugs, terminal connectors screws and motor connection with galvanised sheet trunking 24 SWG including wiring of main motor with 6.0 sq mm copper conductor in PVC insulated, IS Marked etc. including all standard features & fixtures ete all as per IS 14665 all as specified and directed.
Disconnecting and taking out defective shaft wiring and providing new shaft wiring in hoist way up to lower limit switch with PVC insulated 16/18 core flat/round type standard copper conductor cable size 1.00/0.75 Sqmm 1100 volts grade with ISI Marked drawing through in upto ground floor in hoist way for control of all floor hall push button assembly ,limit switch, Firemenswitch etc, complete all as specified.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 13 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight, pulley and car cabin with clamps, nut, bolts and washers etc complete all as specified and directed.
Taking down old unserviceable main steel wire rope after disconnecting old wire rope from counter weight, pulley and car cabin and supply and fix new main steel wire rope 8 mm dia, ungalvanised, 8/19 construction in and including necessary connection with counter weight pully and car cabin with clamps,nuts, bolts and washer etc complete all as specified and directed .
Complete Machine Overhauling by opening of Gear removing old dirty oil, cleaning & Replace of new Gear oil refitting of the same with new packing & adjustment of thrust bearing & keep it into perfect working order.complete all as specified and directed .
Dismantling and taking out unserviceable travelling cable from hoistway & supply and fixing new travelling cable PVC insulated 12 Core flate/ round type with standared copper conductor, conforming to relavent IS in and including thimbles, suspended type freely move with car cabin up and down movement between ground and upper floors including necessary proper connection with mid way junction and other connection require in circuit complete all as specified and directed.
Disconnecting and taking out old defective infra red door sensor of any type and make and supply and fix new infra red door sensor of up to full length of car door complete all as specified and directed.
Taking down old unserviceable aluminium covered wire wond dynamic breaking resister to absorb the reverse energy dissipation of motor during regeneration in control operation suitable for existing capacity complete all as specified and directed.
Taking down broken granite slab and material an labour for mirror polished black granite slab, machine cut, set on vertical surfaces allround with lift facial elevation including back casting cement mortar (1:3) 15 mm thick and joint filling with white cement with pigment to match with shade of granite for lift archive at all floors complete all as specified and directed.
Taking out old unserviceable cabin fan from car cabin, supply and fix new cabin fan non osciliating type axial flow, single speed 300mm sweep, 230 Volts, ISI mark with stainless steel grill. complete all as specified and directed .
Taking down old unserviceablerope over load relay sensor from ropes & fixing new over load relay sensor suitable for up to 13 passenger capacity lift all as specified and directed.
Distmantling and taking out old unserviceable main VVVF unit supply and fix new main VVVF drive unit of suitable for 1 existing panel and connected with existing system including testing and commissioning confirming to same model with specification and same capacity of existing items complete for smooth and jerk free working of lift. Complete all as specified and directed.
Dismantling and taking out unserviceable car door for any paasenger lift from car cabin supply and fixing new car door comprises of 02 No power operated, auto telescopic / centre opening by horizontal sliding stainless steel panel of flush type panels complete with removed headers, hangers, door drive unit with full beam infrared sensor up to full length of car door, aluminium sill VVVF door drive unit for motor complete with all accessories control connection etc. for for any capacity of lift complete all as specified and directed..
Material and labour for drain out the water by mono block submersible motor from the lift cabin pit and cleaning the pit complete all as specified and as directed.
Disconnecting and taking out unseriveable emergency alarm system complete S&F new emergency alaram system assembly on ground fllor landing complete with PCB card battery backup charging uni and speaker including necessary control/electric connection wiring with COP and control panel complete all as specified ands directed in Central machine shope and various other lift of Nofra area.complete all asspecified and directed .
Taking down unserviceable/ burnt lift motor from the lift machine room and M&L for Rewinding of electrical motor 15HP capacity 3 phase 415 V , including rewinding of the motor by proper gauge of copper wire with class E insulation with Varnishing, heating and re-assembling and testing at the site complete all as specified and directed.
Material and labour for Earthing in repair with galvanized steel earth electrode 600x600x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm by means of bolts, nuts & washers of galvanized iron or steel up to the test point all as shown in electrical plate No.3 of SSR Part-I connected to lifts including PCC chamber pit, CI cover, GI funnel with wire mesh, GI protection pipe of 50 mm dia for earth lead and 20mm GI pipe for watering , excavation and earth work in any type of soil, filling the pit with charcol and common salt surrounding the earth plate complete including connecting up to machine drive motor and control panel and testing on completion all as specified and directed .
Taking down old unserviceable Aluminium chequered plate supply & fixing new aluminium Chequered plate ( For Goods Lift) of thickness upto 5mm including removing existing plates complete all as specified and directed .
Supply and Fixing in replacement of Car and Cwt Buffer Spring with all accessories of suitable for 06/08/13 Passenger Lifts various Bldgs of Nofra, complete all as specified and directed.
Taking down unserviceable landing push button box complete with stainless steel plate push buttons and combined digital position indicator and arrow indicator supply and fix e landing push button box complete with stainless steel plate push buttons and combined digital position indicator and arrow indicator complete all as specified and directed.
Disconnecting & taking out defective COP assembly, supply and fix new COP assembly for 08/13 ps lifts illuminated push button for floor position indicator, alarm, non stop, door close, door open, cabin light, stop attendant out key etc including direction indicator of 7 segment display with CPI card on stainless steel face plate duly connected with existing control and electric system complete all as specified and directed.
Taking down unserviceable pit pulley and governor pulley with complete acessories and Supplying &fixing new pit pulley and governor pulley complete all as specified and directed.
Monarch Enterprises (BID ID -3505636)
Shree Elevator Engineering Co. (BID ID -3505622)
Escon Elevators Pvt Ltd (BID ID -3506547)
Veer High Tech Solution (BID ID -3506433)
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.41 MB
BOQ_831276.xls
BOQ • 0.26 MB
8678.rar
Tender Documents • 1.82 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .