Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹2.4 L
Closing Date
23 Apr 2026, 10:00 amClosed
Executive Engineer HPPWD Solan
near new bus stand Solan
Construction of structural/civil work including design, supplying, installing, testing and commissioning of sewerage treatment plant of 150 KLD capacity
2026_PWD_134487_1
solan23.04.2026
Open Tender
Civil Works
Percentage
60 days
Solan
as per SBD
13 documents required · 13 mandatory
₹5,000
₹2.4 L
4 May 2026
17 Apr 2026
23 Apr 2026
17 Apr 2026
23 Apr 2026
17 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Bar Screen Supply, Installation of Manual Bar Screen made of MSEP flat 40x5 mm size, with clear opening of 10 mm, for trapping large size floating impurities from incoming sewage (there will be two bar screen in bar screen chamber of RCC as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 2 | Air diffusers FOR Effluent Collection tank Supply, installation, testing and commissioning of coarse bubble diffusers system with HDPE/PP (10 kg/cm2 rating ) pipe grid as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 3 | Raw Effluent Pumps Supply, installation, testing and commissioning of centrifugal submersible raw Effluent lifting pumps to pump effluet from equalisation tank to Flocuulator with casing of cast iron, make: KSB, Grund fos or Kirloskar complete with pressure gauge, NRV and control valve capable of delivering 5 KL per hour Effluent water at minimum head of 15 m & solid handling capacity of 35 mm with low & high level sensors/switches for Auto ON/OFF, continuous duty, suitable for operation on 415 volt 50 Hz, 3 phase AC supply having a minimum horse power rating necessary to drive the above pump - 2 Lots having 2 Pumps each (1W + 1S) as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 4 | Chemical Dosing Systems For Lime / Alum / Sod. Thio Sulphate Supply, installation, testing and commissioning of dosing pump of Milton/ Prominent/ Minidose / Unitech/ Unitech make,of capacity 100 litre per hour and head 2.0 kg per cm2 , operated on Sodium Thio Sulphate Solution , Alum, Lime . The unit shall consist of 03 no. 500 litters HDPE/ LDPE tank for solution preparation with complete set of pipes, valves and fittings i/c connections as required as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 5 | Chemical Dosing Systems For Poly Electrolite Supply, installation, testing and commissioning of electro-magnetic dosing pump of Milton/ Prominent/ Minidose / Unitech/ Unitech make,of capacity 6 litre per hour and head 3.0 kg per Sq.cm , operated on Sodium Thio Sulphate Solution . The unit shall consist of one no. 500 litters HDPE/ LDPE tank for solution preparation with complete set of pipes, valves and fittings i/c connections as required. | - | set | - | - |
| 6 | Flocculator Supplying, installing, testing and commissioning of MSEP Flocclutaor for 3 KLPH Capacity with Slow speed Agitator of SS 304 for floculation complete with single phase motor for flash mixer. | - | set | - | - |
| 7 | Primary Tube settler Supply Installation Testing and commissioning of Primary Tube settler MOC MSEP 5 MM Capacity 3 KLPH with Sludge seperator media of PP/PVC for for solid and liquid separation to be installed in Primary tube settler tank as required as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 8 | Air diffusers FOR Sewage Collection Tank Supply, installation, testing and commissioning of coarse bubble diffusers system with HDPE/PP (10 kg/cm2 rating ) pipe grid with as required as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 9 | Raw sewage Pumps : Supply, installation, testing and commissioning of centrifugal submersible raw Sewage lifting pumps to pump effluet from equalisation tank to Anoxic Tanks with casing of cast iron, make: KSB, Grund fos or Kirloskar complete with pressure gauge, NRV and control valve capable of delivering 10 KL per hour Effluent water at minimum head of 15 m & solid handling capacity of 35 mm with low & high level sensors/switches for Auto ON/OFF, continuous duty, suitable for operation on 415 volt 50 Hz, 3 phase AC supply having a minimum horse power rating necessary to drive the above pump - 2 Lots (1W + 1S)as required as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
| 10 | Air Diffusion System for MBBR Reactor Supply, installation, testing and commissioning of fine bubble diffusers with Silicon Membrane, having suitable dimensions complete with Aeration grid make it retrievable & to provide clog-free oxygen for MBBR as per requirement for 150 KLD system as required as required as per direction of Engineer in Charge and as per HP.PWD. specification including carriage of all labour equipment and material to various locations through all modes of transportation in all leads and lifts and all incidental charges. | - | set | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.22 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.54 MB
BOQ_198984.xls
BOQ • 0.30 MB
SBD.pdf
Tender Documents • 3.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .