Provision of Air Conditioning Facility in ICU, Light Points, Power Points, Air Conditioners, Wall Mounted Fans, Ceiling Lights at ICU in Ground Floor, Delivery Suite at 1st Floor and Panchkarma Center at 2nd floor Online UPS in ICU, Electrical
2021_SDMC_88201_1
EE/Electrical/WZ/2021-22/13
Open Tender
Electrical Works
Works
30 days
RAJOURI GARDEN
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
Exempted
8 Nov 2021
14 Sept 2021
22 Sept 2021
14 Sept 2021
21 Sept 2021
14 Sept 2021
Amount
Part- A
Air Condition Facility for ICU at Ground Floor and Delivery Suite at First Floor
Supply, installation testing and Commissioning of 2 TR, 5 star Inverter Split air conditioner having copper condensor coil and R32 / better refrigerant
S/I/T/C of 2 TR, 3 star, Window air conditioner having copper condensor coil, rotary compressor and R32/ better refrigerant.
S/I/T/C of Stand for Split AC
S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270 and output voltage of 195-245 V
S/I/T/C of 5 KVA Voltage Stabilizer having input voltage 150V-270 and output voltage of 195-245 V
S/I/T/Cof Copper pipe for Split AC
S/I/T/C of Drain Pipe
S/I/T/C of 3 Core 4 Sqmm Electrical wire for Air Conditioner
Part-B Electrical Work
Lift Related Electrical Work
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125A,36KA,FPMCCB
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63 A, 4 Pole rating, 415 V, 10 KA, "C Curve, miniature circuit breaker suitable for inductive load of following Poles in the existing MCB DB Complete with connections, testing and commissioning etc. as required."
S/I/T/C of MCCB Sheet Metal Enclosure,4P, 100 A-125 A
SITC of 10 W surface/wall mounted LED Bulkhead factual impact dust and water resistant luminairies with IP65/66 Protection
S/I/T/C of LED Tube type luminaire 20 Watt rating complete with Extruded Aluminium Batten prewired with high efficient LEDs with the following: a) Total system wattage 20 Watt + - 5 % c) Luminious efficacy lumens/watt >=95 d) Power factor >= 0.95
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole and neutral
ELECTRICAL WORK IN ICU AT GROUND FLOOR, DELIVERY SUITE AT 1st FLOOR, DIALYSIS UNIT AT GROUND FLOOR
Light Points
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Power Points
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
WALL MOUNTED FANS FOR ICU AND 1st FLOOR
SITC of Wall mounted Fan 400 mm sweep rated voltage 220-230 AC rated frequency 50 Hz speed 1280-1350 rpm white colour etc as required.
Conduit Pipe for Wiring in ICU and 1st Floor
Wiring for Air Conditioners and UPS in ICU
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required.
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
2 X 6 sq. mm + 1 X 6 sq. mm earth wire
2 X 10 sq. mm + 1 X 10 sq. mm earth wire
4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
4 X 4 sq. mm + 2 X 4 sq. mm earth wire
4 X 6 sq. mm + 2 X 6 sq. mm earth wire
4 X 10 sq. mm + 2 X 10 sq. mm earth wire
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way , Double door
12 way , Double door
16 way, Double door
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
6 way (4 + 18), Double door
INDUSTRIAL SOCKET FOR AIR CONDITIONERS IN ICU
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single Pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Double Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
EXHAUST FAN FOR STORE
Supply of 12"(300 mm) sweep 1400 rpm exhaust fan heavy duty complete with shutter blade etc as required
CEILING LIGHT SOURCES
S/I/T/C of Surface Mounting CRCA Housing 36 W LED Luminaire with acrylic cover diffuser prewired with high efficient LEDs with the followingspecifations including fixing on exixting wall/surface including connections as reqd.: a) Total system wattage 36 Watt + - 5 % c) Luminious efficacy lumens/watt >=95 d) Power factor >= 0.95
PILLAR BOX FOR DIALYSIS UNIT AND PANEL ROOM
SITC of Pillar box size 900mm x 450mm x 250mm suitable for mounting incomer of 250 AMCCB/Main switch 4 pole and energy meter 3phase complete with eleethoypic grade Aluminium bus bar of size 25mm x 10mm mounted on galvanized M.S. body power quoted pilferage proof SMC door duly welded with S.S. with rain com size 40mm x 40mm x 5mm x 600mm height in cutting 300 mm height below grand and covered with shode proof SMC sheet of 3 mm as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.
125 A,36KA,FPMCCB
Operation Theatre Examination Light
Supply of Portable Operation Theatre(OT) Examination LED Light:- Dome diameter: 150-250mm, Lux Intensity (A1 Meter): 50000-100000 Lux, Focus Diameter:100 mm to 200 mm, Colour Rendering Index:90-96 RA, Colour Temperature: 3200-5500K, Dimming Range: 10-100% Digital, LED Life : >50000 Hours, LED Wattage: 1-3 W per LED, Power Consumption: 10-20W, No. of LED:- 10-35, Power Supply: 220 V 50 Hz AC
10 KVA ONLINE UPS
Supplying and Installation of ONLINE UPS 10 KVA/192 V DC Single phase Input and Single phase Output Online UPS System
S/I/T/C of UPS VRLA Sealed Battery (12 V/ 65 AH)
S/I/T/C of Battery Rack(20*65A) & Links & Accessories
Cable Tray for ICU Room, Lift Machine Room, Dialysis Unit
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
150 mm width X 50 mm depth X 1.6 mm thickness
Electrical Cable, laying and end termination for ICU ROOM, DIALYSIS UNIT and LIFTS
Supply of XLPE insulated PVC Sheathed Al. Conductor Armoured Cable 1.1 KV Grade conforming to IS-7098 of following size;-
4 Core, 50 sqmm
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.
Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
4 x 50 sqmm
Earthing for Air Conditioning Facility in ICU, Lift Machine Room and Dialysis Unit
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required
SACHDEVA ELECTRICALS
Kamal Electricals
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .