Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹6.6 LAccepted-AOC COLLEGE ROAD CHABUA PO CHABUA DIST DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | 1 | Accepted-AOC ACCEPTED | |
| 2 | 2₹8.1 L+₹1.5 L (23.3%)Rejected-Finance | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹6 L
EMD Value
₹12,000
Closing Date
24 Mar 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) JORHAT
HQ CWE (AF) JORHAT, ROWRIAH, ASSAM-785005
84127/E8 REPAIRS/MAINT OF COOLING APPLIANCES AND ALLIED WORKS AT TAMULBARI UNDER GE AF CHABUA
2025_MES_698620_1
84127/E8
Open Tender
Civil Works - Others
Item Rate
180 days
GE AF CHABUA
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE AF CHABUA
₹12,000
Yes
21 May 2025
20 Feb 2025
25 Mar 2025
20 Feb 2025
24 Mar 2025
6 Mar 2025
Amount
REPAIRS/MAINT TO FANS
Disconnecting & Taking down Ceiling Fan, Exhaust Fan, etc., Sealing Cable End, Dismantling Blades and Removing Fan and Blades to MES Store and Deposited, complete all as specified and as directed.
Disconnecting & Taking down Unserviceable Ceiling Fan of any Size & Make, Removing Fan to AGE E/M STORE YARD for Opening & Checking in Presence of a Board of Officers to ascertain the Quantum of Defects & Repair Works involves, Repairing Fan to Functional including Replacing Unserviceable Parts, Re-assembling & Testing the Fan on Full Load to Entire Satisfaction of Engineer-in-Charge after Repaired, complete all as specified and as directed. NOTE :- (a) Defective/Unserviceable Parts (to be replace) & Rewinding will be Measured and Paid for separately under respective Items here-in-after. However, Cost of Taking down/ out Unserviceable Parts and Fixing of New Parts will deem to be included in the Quoted Unit Rate. (b) Any Minor Items and/or Any Repair Works involves to Make the Fan Functional, even if not notified by the Board of Officers, the same will be carried out by the Contractor without any Extra Cost to the Department.
Supply only Bearing 6201 (as approved) suitable for Ceiling Fan 1200/ 1400mm Sweep, complete all as specified and as directed. MAKE : BOSCH/ NBC/ SKF/ TATA
Supply only Bearing 6202 (as approved) suitable for Ceiling Fan 1200/ 1400mm Sweep, complete all as specified and as directed. MAKE : BOSCH/ NBC/ SKF/ TATA
Supply only Capacitor 2.5 mfd, Epoxy Filled type, Copper Wound, (as approved) suitable for Ceiling Fan 1200/ 1400mm Sweep, complete all as specified and as directed. MAKE : EPCOS/ HAVELLS/ TIBCON
Supply only Gun Metal Bush (as approved) suitable for Ceiling Fan 1200/ 1400mm Sweep, complete all as specified and as directed. MAKE : BOSCH/ NBC/ SKF/ TATA
Supply only Rubber Insulator, Reel type (as approved) suitable for Ceiling Fan 1200/ 1400mm Sweep, complete all as specified and as directed.
M&L Preparing Surfaces of Ceiling Fan 1200mm/ 1400mm Sweep Complete including Cleaning all Dust, etc., Filling Cavities with Filler and Applying One Coat Synthetic Enamel Paint (as approved) with using Spray Machine/ Gun including Stencil Writing Numbers, Letters, Figures, etc. not exc. 30mm in High with Black Color Synthetic Enamel Paint, complete all as specified and as directed.
M&L Re-hanging Ceiling Fan 1200mm/ 1400mm Sweep (after Repaired in all respect) and Connecting up with and including 3 Core Flexible Copper Conductor of suitable Length, complete all as specified and as directed.
S&F Ceiling Fan 1200mm Sweep complete with Blades, Down Rod, Electronic Regulator & Accessories, having Minimum Air Delivery 210 CFM with Service Value 6.00 BEE, 5 Star rated with Brushless Direct Current Motor (BLDC) and Connecting up with and including 3 Core Flexible Copper Conductor of suitable Length, complete all as specified and as directed. MAKE : CROMPTON ENERGION HS/ HAVELLS AMBROSE/ USHA ENERGIA
S&F Exhaust Fan 250mm Sweep, 1200 RPM, Made Of Sturdy Engineering Plastic Complete With Louvers Shutter, Copper Winding, 230 Volt, 50 Hz, Fixing to existing Location, Connecting up with and including 3 Core Flexible Copper Conductor of suitable Length including Make Good Disturbed Surfaces of Walls in Cement Mortar 1:3 and Applying Surface Treatment to Match the Adjacent Surfaces/ Area, complete all as specified and as directed. MAKE : CROMPTON (BRISK AIR_WHITE)/ HAVELLS (MODEL 250MM FAN VENTIL AIR DX WHITE)/ USHA (CRISP AIR VX)
S&F Exhaust Fan 300mm Sweep, 1200 RPM, Steel body Complete with Blades, Aluminium Louvers Shutter & Frame, 230 Volt AC, Single Phase, Fixing to existing Location, Connecting up with and including 3 Core Flexible Copper Conductor of suitable Length including Make Good Disturbed Surfaces of Walls in Cement Mortar 1:3 and Applying Surface Treatment to Match the Adjacent Surfaces/ Area, complete all as specified and as directed. MAKE : CROMPTON EXHD/ HAVELLS TERBO FORCE/ USHA TERBO HD
REPAIRS/MAINT TO AC
Disconnecting from Socket Outlets Split type/Window type AC of Capacity upto 2.0 Ton of any Make, Servicing by Dusting, Cleaning of Indoor and Outdoor Units, Removing AC to AGE E/M STORE YARD for Opening & Checking in Presence of a Board of Officers to ascertain the Quantum of Defects & Repair Works involves, Rectifying Gas Leakage by Applying necessary Brazing, Adjusting and Rectifying Faulty Operation of Electrical and Electronic Remote Control Panels, Replacing of Perished Electrical Wires for Proper Connection from Voltage Stabilizer, Reinstalling the Units to its Original Positions, Replacement of Remote Cell, complete all as specified and as directed. NOTE :- (a) Defective/Unserviceable Parts (to be replace), Gas, etc. will be Measured and Paid for separately under respective Items here-in-after. However, Cost of Taking down/ out Unserviceable Parts and Fixing of New Parts will deem to be included in the Quoted Unit Rate. (b) Any Minor Items and/or Any Repair Works, involves to Make the AC Functional, even if not notified by the Board of Officers, the same will be carried out by the Contractor without any Extra Cost to the Department.
Supply only Blower Fan, PVC (as approved) for Window type AC 1.5 Ton Capacity, complete all as specified and as directed.
Supply only Blower Fan, PVC (as approved) for Split type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Compressor Unit (as approved) including Supply of Refrigerant/ Gas (as required) and Charging the System suitable for Window/ Split type AC 1.5 Ton Capacity, complete all as specified and as directed. NOTE : Cost of Refrigerant/ Gas (R22/134A) as required including Charging of Gas will deem to be included in the Quoted Unit Rate.
Supply only Compressor Unit (as approved) including Supply of Refrigerant/ Gas (as required) and Charging the System suitable for Window/ Split type AC 2.0 Ton Capacity, complete all as specified and as directed. NOTE : Cost of Refrigerant/ Gas (R22/134A) as required including Charging of Gas will deem to be included in the Quoted Unit Rate.
Supply only Capacitor 3.15 mfd, Epoxy Filled type, Copper Wound, (as approved) suitable for AC 1.5 Ton Capacity, complete all as specified and as directed. MAKE : EPCOS/ HAVELLS/ TIBCON
Supply only Capacitor 4.0 mfd, Epoxy Filled type, Copper Wound, (as approved) suitable for AC 2.0 Ton Capacity, complete all as specified and as directed. MAKE : EPCOS/ HAVELLS/ TIBCON
Supply only Condenser, Split Outdoor, Fins type (as approved) suitable for AC 1.5 Ton Capacity, complete all as specified and as directed.
Supply only Condenser, Split Outdoor, Fins type (as approved) suitable for AC 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Display Board (as approved) suitable for Split/ Window type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Indoor Unit Fan Motor (as approved) suitable for Split type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Outdoor Unit Fan Motor (as approved) suitable for Split type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only PCB Board (as approved) suitable for Split type AC 1.5 Ton Capacity, complete all as specified and as directed.
Supply only PCB Board (as approved) suitable for Split type AC 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Relay (as approved) suitable for Split/ Window type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Remote Control (as approved) suitable for Split/ Window type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Sensor for Indoor Unit (as approved) suitable for Split/ Window type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Starting Capacitor 45+6 mfd (as approved) suitable for AC 1.5 Ton Capacity, complete all as specified and as directed.
Supply only Starting Capacitor 55+6 mfd (as approved) suitable for AC 2.0 Ton Capacity, complete all as specified and as directed.
Supply only Swing Motor of Lower Shutter (as approved) suitable for Split/ Window type AC upto 2.0 Ton Capacity, complete all as specified and as directed.
Supply only & Charging of Refrigerant R-22/307, complete all as specified and as directed.
Taking down Carefully Unserviceable Electronic PCB Board at existing AC 1.5 Ton/ 2.0 Ton Capacity, Repairing the Same and Re-fixing after Repaired, complete all as specified and as directed.
S&F Brass Service Valve 1/4" dia (as approved) including Taking down/ out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Brass Service Valve 1/2" dia (as approved) including Taking down/ out Unserviceable Valve of any description, complete all as specified and as directed.
S&F Copper Pipe 1/4" dia (as approved) including Taking down/ out Unserviceable Pipe of any description, complete all as specified and as directed.
S&F Copper Pipe 1/2" dia (as approved) including Taking down/ out Unserviceable Pipe of any description, complete all as specified and as directed.
S&F Insulation Copper Pipe/ Tube of Size 1/4''/ 1/2'', Pipe/ Tube fixing to/ with Split type AC upto 2.0 Ton capacity, complete all as specified and as directed.
S&F AC Stand Mounting Bracket Heavy duty suitable for Outdoor Unit of AC 1.5 Ton/ 2.0 Ton Capacity including necessary Cement Concrete 1:2:4 (20mm graded stone aggregates) Block and Brick Masonry Work in Cement Mortar 1:4 including Rendering 10mm thick in Cement Mortar 1:4, complete all as specified and as directed. NOTE : Cost of Cement Concrete, Brick Masonry, Rendering Works as required will deem to be included in the Quoted Unit Rate.
REPAIRS/MAINT TO GEYSERS
Disconnecting Electric Supply & Water Connections from Wall mounted Geyser 25/35 LITRE Capacity and Removing Geyser to MES Store and Deposited, complete all as specified and as directed.
Disconnecting Electric Supply & Water Connections from Wall mounted Geyser 25/35/50 LITRE Capacity, Taking down and Removing Geyser to AGE E/M Store Yard for Opening & Checking in Presence of a Board of Officers to ascertain the Quantum of Defects & Repair Works involves, Repairing Geyser to Functional including Replacing Unserviceable Parts, Re-assembling & Testing the Geyser to Entire Satisfaction of Engineer-in-Charge after Repaired, complete all as specified and as directed. NOTE :- (a) Defective/Unserviceable Parts (to be Replace) will be Measured and Paid for separately under respective Items here-in-after. However, Cost of Taking down/ out Old Unserviceable Parts and Fixing of New Parts will deem to be included in the Quoted Unit Rate. (b) Any Minor Items and/or Any Repair Works involves to Make the Geyser Functional, even if not notified by the Board of Officers, the same will be carried out by the Contractor without any Extra Cost to the Department.
Supply only Heating Element 1.5 KW, Cup/ Triangular type (as approved), 230 Volt, AC suitable for Geyser, complete all as specified and as directed.
Supply only Heating Element 2.0 KW, Cup/ Triangular type (as approved), 230 Volt, AC suitable for Geyser, complete all as specified and as directed.
Supply only Neon Indicator Lamp (Red/ Green), Round/ Rectangular type (as approved) suitable for Geyser, complete all as specified and as directed.
Supply only Safety Valve/ Fusible Plug 15mm bore of Brass (as approved) suitable for Geyser, complete all as specified and as directed.
Supply only Thermostat Switch (as approved) suitable for Geyser 25 LITRE Capacity, complete all as specified and as directed.
Supply only Thermostat Switch (as approved) suitable for Geyser 50 LITRE Capacity, complete all as specified and as directed.
M&L Preparing Surfaces of Geyser upto 25 LITRE Capacity including Cleaning all Dust, etc., Filling Cavities with Filler and Applying One Coat Synthetic Enamel Paint (as approved) with using Spray Machine/ Gun including Stencil Writing Numbers, Letters, Figures, etc. not exc. 30mm in High with Black Color Synthetic Enamel Paint, complete all as specified and as directed.
S&F PVC Hot & Cold Water Connecting Pipe 450mm long, Heavy duty as Inlet/ Outlet Pipe and fixing with Brass Ferrule Nuts on Both Sides suitable for Geyser 25/ 35/ 50 LITRE Capacity including Taking down/ out Unserviceable Connecting Pipe of any description, complete all as specified and as directed.
S&F PVC Insulated Sheathed Copper Conductor Cable 2.5 Sqmm 3 Core suitable for Connecting Wire of Geyser including Taking down/ out Unserviceable Cable of any description, complete all as specified and as directed.
S&F Geyser (Electric Water Heater) 25 LITRE Capacity, Storage type, Steel Body with Copper Inner Tank and Heating Element upto 2.0 KW, BEE 5 Star rated complete with all Accessories such as Safety Valve, Thermostat, NRV, Connection Piece, etc. and fixed on Walls with suitable Supports of Mild Steel/ Wooden Frame to support and Mild Steel Bolts, Nuts & Washers, etc., Make Good Disturbed Surfaces of Walls in Cement Mortar 1:3 and Applying Surface Treatment to Match the Adjacent Surfaces/ Area, Providing Electric Supply & Water Connections and Testing, complete all as specified and as directed.
REPAIRS/MAINT TO REFRIGERATORS
M&L Opening Defective Refrigerator 280/310 LITRE Capacity of any Make/ Model/ Type, Removal of Blockage by Flushing out, Brazing (as required) and making the system Fully Leakage Proof, Replacing Unserviceable Compressor & Other Parts and Re-assembling after necessary repaired and Testing, complete all as specified and as directed NOTE :- (a) Defective/Unserviceable Parts (to be Replace) will be Measured and Paid for separately under respective Items here-in-after. However, Cost of Taking down/ out Old Unserviceable Parts and Fixing of New Parts will deem to be included in the Quoted Unit Rate. (b) Any Minor Items and/or Any Repair Works involves to Make the Refrigerator Functional, even if not notified by the Board of Officers, the same will be carried out by the Contractor without any Extra Cost to the Department.
Supply only Cooling Coil (as approved) suitable for Refrigerator 280/310 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
Supply only Over Load Relay (as approved) suitable for Refrigerator 280/310 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
Supply only Starting Relay (as approved) suitable for Refrigerator 280/310 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
Supply only Thermostat Switch (as approved) suitable for Refrigerator 280/310 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
REPAIRS/MAINT TO DEEP FREEZER & WATER COOLERS
M&L Opening Defective Deep Freezer 320/405 LITRE Capacity of any Make/ Model/ Type for Checking/ Repairing, Removal of Blockage by Flushing Out, Brazing (as required) Suction & Discharge Pipes for Making the System Fully Leakage Proof, Cleaning thoroughly Cooling Coil to achieve Proper Cooling effect, Replacing Unserviceable Compressor & Other Parts and Re-assembling after necessary repaired & Testing, complete all as specified and as directed. NOTE :- (a) Defective/Unserviceable Parts (to be Replace) will be Measured and Paid for separately under respective Items here-in-after. However, Cost of Taking down/ out Old Unserviceable Parts and Fixing of New Parts will deem to be included in the Quoted Unit Rate. (b) Any Minor Items and/or Any Repair Works involves to Make the Deep Freezer Functional, even if not notified by the Board of Officers, the same will be carried out by the Contractor without any Extra Cost to the Department.
Supply only Over Load Relay (as approved) suitable for Deep Freezer 320/405 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
Supply only Starting Relay (as approved) suitable for Deep Freezer 320/405 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
Supply only Thermostat Switch (as approved) suitable for Deep Freezer 320/405 LITRE Capacity of any Make/ Model/ Type, complete all as specified and as directed.
S&F Water Cooler Tap (as approved) suitable for Water Cooler including Taking down/ out Unserviceable Water Cooler Tap of any description, complete all as specified and as directed.
REPAIRS/MAINT TO VOLTAGE STABILIZER & MISC ITEMS
M&L Disconnecting existing Cable, Dismantling Voltage Stabilizer upto 5.0 KVA Capacity, Single Phase, 240 Volt AC, Repairing/ Replacement of Push on Switch, Relay Transistor, Diode, Voltmeter, Indicator Lamp, High Low Cut out complete Parts, Re-assembling the Voltage Stabilizer after Repaired, Re-installed and Testing & Commissioning including Transportation Charges from the Site of Work to Workshop and Back, complete all as specified and as directed. NOTE : Cost of All Materials & Labour Elements required for Making the Voltage Stabilizer Functional will deem to be included in the Quoted Unit Rate.
S&F Voltage Stabilizer 5.0 KVA Capacity, Single Phase, 230 Volt, 50 Hz suitable for Split/ Window type AC 1.5/ 2.0 Ton, Working Range 130 - 280 Volt, Time Delay System including Taking down/ out Unserviceable Voltage Stabilizer of any description and Removing Voltage Stabilizer to MES Store and Deposited, complete all as specified and as directed. MAKE : BLUELAND/ MICROTEK/ V-GUARD
S&F MCB 6 Amp to 32 Amp, Single Pole (SP), 'C' Series, 50 Hz, 10 kA, 240 Volt and Connecting up including Taking down/out Unserviceable MCB, complete all as specified and as directed.
S&F Sheet Metal Enclosure, Single Pole & Neutral, having 2-Pin Earth Plug & Socket, IP-43 Protected, Fixed with MCB 20 Amp (01 No.) Single Pole, 240 Volt and Connecting up including Taking down/out Unserviceable Sheet Metal Enclosure, complete all as specified and as directed.
DEDUCTION AGAINST SCHEDULE OF CREDIT
Bidder(s) shall/ will Quote the EQUAL AMOUNT as per SCHEDULE OF CREDIT catered at SERIAL PAGE No. 22 of Tender documents under Column 5 i.e. 'UNIT RATE' (M) against Row No. 86 .
M/S PRABIR ROY (BID ID -3265224)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .