| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.3 LAccepted-AOC 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | 1 | Accepted-AOC Lowest | |
| 2 | 2₹29.4 L+₹98,133.25 (3.45%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | 2 | Rejected-Finance Higher | |
| 3 | 3₹29.4 L+₹98,360.35 (3.46%)Rejected-Finance HOUSE NO 40 CHOTTI BARADARI PART I GARHA ROAD NEAR MEDICAL COLLEGE JALANDHAR PB 144022 | JALANDHAR | JALANDHAR | PUNJAB | 144022 | 3 | Rejected-Finance Higher |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
20 Aug 2020, 4:00 pmClosed
GE Amritsar
GE Amritsar PIN-143001
SPECIAL REPAIR TO EXTERNAL WATER SUPPLY DISTRIBUTION LINE, ELECTRONIC ENERGY METER AND OTHER E/M SANCTIONED WORKS AT AMRITSAR CANTT
2020_MES_361724_1
GE/ASR-17/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE Amritsar
Class E, Category aii and bi
8 documents required · 8 mandatory
₹500
GE Amritsar
₹46,000
Yes
25 Sept 2020
21 Jul 2020
21 Aug 2020
21 Jul 2020
20 Aug 2020
7 Aug 2020
Amount
Supply and fix single phase energy meter with LCD type display AC single phase accuacy class 1.0 rating 10 to 60 Amp 240 Volts 50 Hz with optical and RS485 COM port compact meter with ceiling screw provn complete inclduing connection all as specified and directed. Make :- L&T/Secure/HPL
M & L for sub main wiring with 1100 volt grade two single core FR Wire PVC insulated and unsheathed cable with stranded copper conductor 6 sqmm and 1 run of 6 sqmm drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (Part-III) 1983 mark, or relevant ISI mark with all accessories fixed concealed including chase cutting in brick/ stone masonry for fixing conduit and making good the disturb surfaces of wall as per existing including 6 sqmm multi - stranded copper conductor as earth wire in green colour complete all as specified and directed. Including taking down old unserviceable sub main wiring. Make of FR wire :- Polycab, Havells / RR Cable, Make of PVC pipe : - Polycab, Finolex, Kalinga .NOTE: 2 single core 6 sqmm and one 6 sqmm cable and PVC conduit shall be measured as one RM. Make RR Kabel/Polycab/Havells
Excavation in trenches not exc. 1.50 m wide and not exc. 1.50 m in depth for foundation etc. or for laying of pipes and fittings, cables, HT / LT poles, stay assembly, DI/GI pipes etc including forming bottom surfaces to required level and slope and getting out in hard / dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm thick in each layer as in hard / dense soil complete all as specified and directed.
Removing surplus excavated material (SOIL) to distance not exc. 50 m and depositing where directed at a level not exc. 1.50 m above the starting point complete all as specified and directed.
Taking out CI/GI Tubing 100 mm nominal bore incl old fittings and connections & removing from site all as specified and directed by Engr-in-charge.
Taking out CI/GI Tubing 80 mm nominal bore incl old fittings and connections rremoving from site all as specified and directed by Engr-in-charge.
Taking out GI Tubing 50 mm nominal bore incl old fittings and connections removing from site all as specified and directed by Engr-in-charge.
Taking out GI Tubing 40 mm nominal bore incl old fittings and connections & removing from site all as specified and directed by Engr-in-charge.
Taking out GI Tubing 25 mm nominal bore incl old fittings and connections & removing from site all as specified and directed by Engr-in-charge.
Taking out GI Tubing 20 mm nominal bore incl old fittings and connections & removing from site all as specified and directed by Engr-in-charge.
Material and labour for ductile iron pipe 100 mm nominal bore with spigot and socketed end class K-7 suitable for rubber ring joints, laid in trenches, under the roads or fixed on walls with suitable clamps nuts bolts and washers including rubber ring joints all as specified and directed by Engr-in-charge. Make : Electro steel/Jindal/TATA Note : 1. The DI fitting shall be measured and paid separately under respective items.2. Earth work will be measured and paid for separately.3. Rubber ring joints will be included in overall quoted rate.
Supplying, fixing, connecting & testing of GI tubing 80mm bore medium grade, ISI marked including all fittings laid in trenches, under floors, fixed to walls etc, complete all as specified and directed by Engineer-in-charge. Make: JINDAL/TATA/PRAKASH. Note: (a) Excavation and earth work will be meaured and paid separately. (b) Cost of GI bends, sockets, unions and connected items will be deemed to be included in the unit rate quoted by the contractor.
Supplying, fixing, connecting & testing of GI tubing 50mm bore medium grade, ISI marked including all fittings laid in trenches, under floors, fixed to walls etc, complete all as specified and directed by Engineer-in-charge. Make: JINDAL/TATA/PRAKASH. Note: (a) Excavation and earth work will be meaured and paid separately. (b) Cost of GI bends, sockets, unions and connected items will be deemed to be included in the unit rate quoted by the contractor.
Supplying, fixing, connecting & testing of GI tubing 40mm bore medium grade, ISI marked including all fittings laid in trenches, under floors, fixed to walls etc, complete all as specified and directed by Engineer-in-charge. Make: JINDAL/TATA/PRAKASH. Note: (a) Excavation and earth work will be meaured and paid separately. (b) Cost of GI bends, sockets, unions and connected items will be deemed to be included in the unit rate quoted by the contractor.
Supplying, fixing, connecting & testing of GI tubing 25 mm bore medium grade, ISI marked including all fittings laid in trenches, under floors, fixed to walls etc, complete all as specified and directed by Engineer-in-charge. Make: JINDAL/TATA/PRAKASH. Note: (a) Excavation and earth work will be meaured and paid separately. (b) Cost of GI bends, sockets, unions and connected items will be deemed to be included in the unit rate quoted by the contractor.
Supplying, fixing, connecting & testing of GI tubing 20 mm bore medium grade, ISI marked including all fittings laid in trenches, under floors, fixed to walls etc, complete all as specified and directed by Engineer-in-charge. Make: JINDAL/TATA/PRAKASH. Note: (a) Excavation and earth work will be meaured and paid separately. (b) Cost of GI bends, sockets, unions and connected items will be deemed to be included in the unit rate quoted by the contractor.
Supply and fix CI sluice valve in replacement with forged brass stem class PN- 1.6 ISI marked with stainless steel spindal and flanged both ends of size 100 mm dia bore with hand wheel conforming to IS 14846. Make : Kirloskar/Kartar/BIR
Supply and fixing of Gun-metal, globe or gate valves of size 50 mm dia , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fixing of Gun-metal, globe or gate valves of size 40 mm dia , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fixing of Gun-metal, globe or gate valves of size 25 mm dia , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fixing of Gun-metal, globe or gate valves of size 20 mm dia , with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Cutting existing steel tubings for alteration/additions or branch connections etc. all as specified of 50/40mm bore. ( Each cut measured ), complete all as specified and directed by Engr-in-charge.
Cutting existing steel tubings for alteration/additions or branch connections etc. all as specified of 25 mm bore. ( Each cut measured ), complete all as specified and directed by Engr-in-charge.
Cutting existing steel tubings for alteration/additions or branch connections etc. all as specified of 20 mm bore. ( Each cut measured ), complete all as specified and directed by Engr-in-charge.
Boring of holes under road pavement, hard standing by the help of boring machine or manually by deploying suitable manpower and tools/plant including safety of personnel.
Material and labour for ISI marked CI/ductile iron fittings up to size 200 mm dia such as bends, Tapers tale pieces, Tee pieces (single branch) Y junction double branch,cross collars, caps and plug set including rubber ring push on joints complete as specified and directed Make Electro steel/JINDAL/Tata
M&L for constructing of brick masonry valve pits of internal dimensions 1.0 mtr x1.0 mtr x1.0 mtrs (PCC floor of valve pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space), bottom floor of the pit be constructed in PCC (1:3:6) 15 cms thick with 20 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The sluice valve and other fittings should be housed in center of the pit, the vertices of the pit should in right angle and champhered. The top cover of the pit will be made out of MS sheet min 2mm thick witth angle iron frame made out of MS angle 50mm x50 mmx 6 mm with galvanised steel hindges two nos welded with MS frame and locking arrangements duly painted with two coats of synthetic enamelled paint over one coat of red oxide primer.
Supply and fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 meter long) complete all as specified and directed by Engineer in Charge.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 4 core 16 Sqmm. Make :- Havells/Polycab/RR kabel.
Supply and fix in replacement of 60W LED light fitting made of pressure die cast aluminium alloy for housing heat sink for effective thermal management studyness excellent corrosion resistance cable gland is used for maintaining ingressprotection epoxy powder coated grey colour finish after phosphochromate treatment, tempered protective toughened glass, thermal shock and impact resistance fixed to the housing with SS screws. High efficacy long life LED module with the SMD LED package mounted on MCPCB with lumen efficacy of LED >140 lumen/Watt with PC lens to ensure better uniformity of light distribution, ambient temperature 35 degree celcius .and system lumen 9000 for above. Power by built in isolated electronic driver SMPS base constant current supply with lower THD, output open slash short circuit protection , Over voltage protection , Phase to phase protection , surge voltage protection 10 KVA. with IK 07 and IP 66 protection, CCT 5700K CRI more than 70 THD<10%, SPD 10 KVA for internal and external 10 KVA extra should be fixed with fitting, PF> 0.95 IP66 IK07 protection with life of 50000Hrs @ L70 operating temp -10 degree to +50 degree input supply voltage range 140/270V frequency 50/60Hz . Driver safety requirement standard: IS 15885/2/13, driver performance requirement IS 16104. Photobiological safety norms IS 16108. Certification LM 79 for luminar LM 80 for LED. And warranty should be 5 Years on site.
M&L for earthing complete with galvanised steel earth plate electrode 600mmx600mmx6.3 mm thick burried in ground vertically to a depth not less than 2.25 meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15 cm thick layers of common salt and charcoal dust starting FRLSom ground below 15 cm of earth plate and up to 15 cm above the same. GI plate connected with galvanised iron earth lead of size 4 mm by means of galvnised nuts, bolts and washers. GI wire of 4 mm dia laid in 15 mm dia light grade GI pipe as protection FRLSom top of the plate up to test point (cost of protection pipe up to 7.5 meters FRLSom earth electrode will be included in the rates quoted by the contractor.
S&F of street light fitting brackets 1.5 meter long made out of galvanized iron pipe of 32/40 mm dia size suitable for LED fittings light grade complete with nut bolts washers etc inclusive of one primer coat one under coat and one finishing coat of silver paint complete all as specified and directed by Engr-in-Charge.
S&F of Junction Box shall be insulated and made out of Polycarbonate with glass fiber reinforced. The size should be not less then 200 X 160 X 98 in mm cat. Part no KF5255. The Polycarbonate JB shall be environment friendly, recyclable, UV resistant, halogen & silicon free, anti acid & anti corrosive including 6 A SP MCB, breaking capacity 10 kA. The JB shall be rated for Degree of Ingress Protection IP 66 in accordance with IEC 60529. The gasket material shall be Polyurethane and the gasket shall be internally embedded. The JBs shall be complies with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670 –22 & IEC 60670 – 2-5. The JB color according to RAL 9011. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate. For better safety the Polycarbonate encl shall be fire retardant & self-extinguishing in accordance with IEC 60 695-2-11, DIN VDE 0304 Part 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wir test for 960 deg. Cent. The impact strength of polycarbonate enclosures / boards i.e. the Degree of Protection against Mechanical load shall be in accordance with EN 50298-98 for IK 08. Made of Hensel/Rittal or equivalent. Manufacturer should submit routine test certificate for CJB/PJB.
M&L PVC insulated FR PVC Sheathed multi stranded copper conductor wire 2.5 sqmm size twin core complete for drawing through pole for making connection to street light fitting provided on poles upto junction box incl thimbles.
Excavation for poles in trenches in any type of soil .n exc. 1.5 mtr wide and exc 1.5 mtr in depth all as specified & directed.
Material and labour for PCC 1:4:8 type D-2, using stone aggregate 40mm graded as in sub base foundation for electric poles including necessary form work where required and fair finish to the exposed surfaces all as specified & directed by Engr-in-charge.
All as per srl item No 37 here-in-before but PCC 1:3:6 type C-1 as in foundation of poles.
All as per srl item No 37 here-in-before but PCC 1:2:4 type B-1 as for coping of poles including necessary formwork etc.
Supply and laying old size as sub class 'B' bricks, laid flat in trenches over the cable along the length of cable and bricks perpendicular to the direction of cable adjacent / abutting each other compete all as specified . and directed by Engr-in-Charge.
M&L for sand cushioning with layer of sand 8 cm thick before laying of cable and 15 cm after lying of calbe in trenches complete all as specified & directed. Note :- Thickness after punning shall be measured.
S&F street light distribution outdoor panel with canopy single door vertical type made out of CRCA MS sheet with thickness not less than 3 mm surface with insulated material like polysofer or with epoxy powder coating surface mounting TPN 4 way,415 Volt with copper bus bar rating 200Amps for R,Y,B,N phases dust and vermin proof suitable for incorporation of MCCB and IP43-IK09 profection with and incl 100Amps 16KA 4 Pole MCCB including angle iron support legs and foundation work for the legs (including excavation and doing PCC 1:2:4). Make of MCCB Legrand/Schnedier/Siemens. The size of the panel should not be less than 600mmx400mmx200mm, and height of the panel should be atleast 300mm above ground level. the angle iron for support should be minimum 35 mm x 35mm x 5 mm thick.
S&F in replacement of galvanised iron pipe of 50mm nominal dia light grade fixed to poles with clamps nuts, bolts washers or laid under road cutting or fixed to wall incl painting two coats of aluminium paint over coat of red oxide paint complete all as sprecified and directed by Engr-in-charge.
S&F of AC 3 phase LT CT operated static Electronic Energy meter with accuracy class of 1.0, 3x240 Volts, 50 Hz, with Backlit LCD Display of rating - /5A capable of measuring KWH complete all as specified and Directed.
S&F of low tension tapewound ring type Toroidal CT with CT ratio of 200/5 , accuracy class 1.0 complete all as specified and directed
S&F of low tension tapewound ring type Toroidal CT with CT ratio of 400/5 , accuracy class 1.0 complete all as specified and directed
Supply and fixing of Submersible pump with motor complete set of not less than 45 hp or next higher capacity suitable for the required flow and head water cooled copper rotor motor sync. Speed 2880 rpm at rated 415 volts with wide voltage variation of +5% and -10%, 3 Phase , 50 Hz. A.C. power supply with QC8 mixed flow pump suitable for 300mm/350mm dia deep borewell , 2000 LPM & 70 meter water Head conforming to IS 8034 and IS 9283. Bore hole with normal clean drinking water. Recommended to operate upto 40 degree centigrade at mean sea level complete all as specified and directed.Note: (a) Lifting of old pump and Lowering of the pump including connecting the delivery pipe and making electric connection are included in the quoted rates. (b) The discharge outlet of the pumset should be 150mm dia.
Supply and fixing in replacement, for MS flanged pipe of size 150 mm dia heavy duty 'C' class with necessary MS bolts, nuts and washers, packing material, rubber gaskets, pressure gauge for lowering etc complete all as specified and as directed by Engr-in-charge.
Supply, installation, testing and commissioning of Air Conditioner, Split type, (Indoor, outdoor unit), single phase, rotary compresser and condenser coil of copper having cooling capacity 4500 K Cal per hour (1.5 ton), BEE rating 3 star or above refregirent type R410A/R32 with cordless remote control unit complete all as specified and directed. Make - Voltas; Samsung, LG
Supply, Installation & testing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 140V to 270V with out put voltage stabilized at 230V with accuracy of + 2.5% with time delay system and of caapcity 4KVA complete all asspecified. Make - Voltas, V-Guard VM 500, Microtek, Luminous
M & L single pole and neutral enclosure 32 A ,230 V with a two pin and earthplug and socket complete with one Single pole MCB 32 A complete all as specified and directed.Make Legrand/Siemens/Schiender
M & L for sub main wiring with PVC insulated, 1100 volts grade single core FR multistranded copper conductor cable conforming to IS specifications, 2 runs of 4 sqmm including 1 run of 4 sq mm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Make of FR wire; Polycab/Havells/RR Cable,Make of PVC Pipe - Polycab/FInolex/Kalinga premium. Note : 2 Run of 4 sqmm, 1 Run of 4 sq mm and 1 run of PVC conduit will be mesuared as 1 unit.
Material and labour for Point wiring for oneGeyser / AC controlled by one 1-way switch complete with 2.5 Sq mm (nominal area) FR, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked, in and including PVC concealed conduit ISI marked of size 20 mm dia and 1.5 mm wall thickness and PVC conduit fittings such as tees, bends,‘elbow, reducers except conduit junction box (junction box will be of MS) including cutting and chasing and 2.5 Sq mm (nominal area) FR, PVC insulated, un-sheathed and stranded copper conductor cable ISI marked as earth wire, connecting to common earth dolly with thimble, including pressed steel powder coated MS sunken box of suitable size, covered with & including 3 mm thick bakelite, laminated hylem sheet top cover and making good surface as original by plastering and whitewash/ colour/ distemper etc complete all as specified.
All as per item No 53 above but one 2 in 1 pin socket outlet 15 Amps, independent
S & F switch socket combination 2 in 1, 5 pin, 5 and 16 Amp flush type universal complete all as specified and directed
Supply and fixing plug top 3 pin 16 Amp including connection with existing cable complete all as specified
Supply and fixing galvanized iron steel tubing medium grade 15 mm bore with all fitting and fixed to walls, ceiling and laid in floor complete all as specified Note- Quoted rate will include the cost of making water connection from existing supply line and making good of the wall surface etc all as specified.
Supply and fixing Brass chromium plated fancy type bib tabs of size 15 mm dia bore short body, screwed down for GI pipe or for brass ferrule and fixed complete all as specified
S & F MCB SP single pole, 240 volts, 32 Ampere, rupturing capacity 10 KA, ‘c’ curve type complete all as specified and directed. Make polycab havells or equivlant make
Dismantlig floor or wall tiling including cement mortar bedding,removing rubbish of premises complete all specified and directed.
Supply and fixing glaze ceremic colour tile 450 mmX 300mmX6mm /300mmX200mmX6mm thic etc on vertical surfaces such as skirting ,dadop etc set and jointed in neat cemented slurry and pointed in white cement mixed with pigment to match over and including 10mm thick rendering plaster in cement mortar 1:4 on brick surface complete all as specified and directed.
M & L for sub main wiring with PVC insulated, 1100 volts grade single core FR multistranded copper conductor cable conforming to IS specifications, 2 runs of 2.5 sqmm including 1 run of 2.5 sq mm single core multistranded copper conductor, PVC insulated cables as earth continuity conductor drawn through and including one run of 25 mm dia rigid PVC conduit and conduit accessories fixed on wall/ceiling etc., or concealed in wall and connecting to common earth dolly all as specified and directed including taking down all sub main wiring . Make of FRLS wire; Polycab/Havells/RR Cable,Make of PVC Pipe - Polycab/FInolex/Kalinga premium. Note : 2 Run of 2.5 sqmm, Run of 2.5 sq mm and 1 run of PVC conduit will be mesuared as 1 unit.
Supply, installation, testing and commissioning of Refrigerator, capacity not less than 290 liters, Double door. electric driven, single phase, minimum 3 star BEE rated complete all as specified and directed. Make - Samsung LG, Whirlpool.
Supply, installation and testing of voltage stablizer, copper wound, naturally air cooled, indoor type, capacity 1 KVA complete all as specified and directed. Make - Voltas, V-Guard VG 100, Microtek, Luminous
S&F Distribution Board double Door made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection surface mounting SPN 4 way, 240 volts with bus bar rating 200 Amps, dust and vermin proof suitable for incorporation of MCB’s and isolators etc complete all as specified. Make :Legrand Lexic / Hager /Schneider Elect . (Note : cost of removing old wooden box and making good of surface as original by brick work, plastering, whitewash/colour/distemper etc is included in quated rate)
Supply and Fix Storage water heater (Geyser) of 25 litre capacity 230V AC, 50HZ having element of 2 KW of COPPER/INCOLOY alloy , Rust proof outer body,high density PUF insulation, BEE 5 Star Rated and above ,Inner tank of SS 304 which can sustain pressure of minimum 8 Bar working pressure, making electric and water connection complete all as specified. Make AO Smith / Racold/Havells.
Supply and fixing of brass chormium plated angle valve, fancy type of size 15mm dia screwed down for high pressure, complete all as specified and directed.
Supply and fixing of PVC Connection (Hot) of size 15 mm x 600 mm complete all as specified :Make Prayag/Shakti
Supply and fix water cooler electric driven (single phase), having approx storage capacity of 80 litre and nominal cooling capacity of 40 Litres per hour. Make - Sidwal / Voltas / Usha
Supply and fixing 15mm bore stop valves, cast cooper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed but fancy type chromium plated.
Supply, installation, testing and commissioning of glass top deep freezer of capacity 320 LTR single phase 230 Volt, 50 HZ complete all as specified and directed. Make :- Voltas, Bluestar, Godrej
Supply, Installation & testing of voltage stabilizer for automatic operation single phase naturally air cooled indoor type and designed for input variation between 140V to 280V with out put voltage stabilized at 230V with accuracy of + 2.5% with time delay system and of capacity 3 KVA complete all as specified. Make - Voltas, V-Guard VM 500, Microtek, Luminous
S & F in repair MCB double pole, 240 Volts, 32 to 40 Ampere, rupturing capacity 10 KA, 'B' curve type complete all as specified and directed. Make - Legrand / Schiender / Siemens
M & L for point wiring complete with 1.5 sqmm single core PVC insulated unsheathed FR cable 1100 volts grade, multistanded with copper conductors conforming to IS specifications, drawns through and including conceled conduit concealed/fixed on wall / ceiling wiht suitable clamps, screws, etc or concealed in wall including terminal boxes fabricated with 1.6 mm MS sheet concealed in walls covered with palstic laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch sockets outlets, fan regulators, etc, including provn of 1.5 sqmm PVC insulated unsheathed cable with multistandard copper conductor as earth continuity conductor and connecting common earth dolly all as specified and as directed. Make of FR wire - Polycab / Havells / RR cable, Make of PVC pipe - Polycab / Finolex / Kalinga premium. (a) One light point / Bell / fan point controlled by one switch.
Supply and fixing ceiling rose surface bakelite 3 terminals 65x32mm complete all as specified. Make - Anchor / Plaza / SSK
Supply and fixing of exhaust fan of sweep 225 mm complete with self closing louvers, mounted in suitable opening arrangement and suitable for operation on 230 Volts single phase, 50 Hz, AC supply and including two core PVC insulated, PVC sheathed copper conductor flexible cable 1.5 sqmm and making all necessary connection and fixed by using 4 Nos 100 mm long 10 mm dia bolts, nuts and washers and grouted in wall with cement 1:3 completed all as specified and directed. Make - Havells / CG / Orient. Note:- The cost of making hole in the existing wall and making good teh disturbed surface of wall / ceiling etc as original i.e brick work, plastering, white washing etc. is included in the quoted rate and no extra payment will be made to contractor in tis effect.
kapoor and co
UNITED ENGINEERING CORPORATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .