| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.8 L+₹2.9 L (7.01%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in required category | |
| 4 | Rejected-Technical AKULA STREET BHAPUR BAZAR BERHAMPUR DISTT GANJAM ODISHA 760001 | GANJAM | ODISHA | 760001 | - | Rejected-Technical Not enlisted in required category | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in required category |
Tender Value
Refer Docs
EMD Value
₹76,000
Closing Date
31 Aug 2023, 6:00 pmClosed
GARRISON ENGINEER I GOS
GARRISON ENGINEER I GOPALPUR MILITARY STATION PO GOLABANDHA DIST GANJAM ODISHA 761052
REPAIR REPLACEMENT OF PLUMBING SANITARY FITTINGS SUNKEN FLOOR WALL FLOOR TILING ETC OF CERTAIN BLDGS OF AAD CENTRE AND OF HT SWITCHGEARS CABLES JOINT KITS AND ALLIED WORKS UNDER GE I GOS AT GMS
2023_MES_613221_1
8000/49/2023-24/0948/E8
Open Tender
Civil Works
Item Rate
210 days
GOPALPUR MILITARY STATION
As per tender docus
6 documents required · 6 mandatory
₹500
GARRISON ENGINEER I GOS
₹76,000
Yes
6 Nov 2023
11 Aug 2023
1 Sept 2023
11 Aug 2023
31 Aug 2023
24 Aug 2023
Amount
Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed.
M & L brick work with fly ash bricks, Straight or curved onplan exc 6m mean radius,built in 1:6 in cement mortar all as Specified and Directed
M & L for brick work with sub class "B" brick (old size) straight or curved on plan to any radius in half brick thick walls built in CM 1:4 to any radius complete all as specified and directed.
Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 on fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed
M&L for rendering 15mm thick in CM 1:6 on other than fair faces of brick work or concrete surface of wall and to be finished even and smooth with out using extra cement complete all as specified and directed
Supply only integral water proofing compound all as specified and directed.
M&L for preparation of newly plastered surfaces of wall applying two coat of white wash over a coat of primer all as specified and directed.
Dismanting of existing sunken floor treatment incl plaster and removal of all debris and M&L for water proofing treatment on existing sunken floor/wall with the following specification and sequence complete all as specified and directed by Engr-In-Chrg (a) Cleaning the internal surface areas thoroughly so that they are free of all contaminants like dirt and laitance & to remove all the loose materials by various mechanical/manual means. (b) Removal of all surface Imperfections, protrusions ,loose concrete & filling of cracks using Dr Fixit Pidicrete URP Modified Mortar in the ratio Cement: Sand (1:4) and 5% by weight of cement. (c) Providing and making fillets at the junction of the walls and the slabs using cement mortar of 1:4 mix admixed with 5 % of DR. FIXIT URP by weight of cement. (d) Applying two coats of elastomeric compound viz beck bond WPC-30/Master coat IRC over one coat on neat primer i.e. Super latex of Dr Fixit/Master bond of Conchem. (e) Laying protection plaster 15mm, in CM 1:4 admixed with STP/DrFixit diproof LW@200 ml per bag of cement.
Demolition of cement concrete unreinforced in ground floor and paving n exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for PCC 1:5:10 type E-2 using 40mm graded stone aggregate as in filling of sunken floor etc and mass concrete complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded stone aggregate, 75mm thick in plinth protection laid in panels and finished even and smooth without using extra cement including necessary form work complete all as specified and directed. Note : Joints 12mm wide to the full depth of PCC shall be provided at every 3 meters and at every change of direction and shall be filled with mixture of bitumen and sand 1:3 by weight. Cost of this provision shall be deemed to be included in the quoted rate for concrete in plinth protection.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in Sub base flooring 100 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
M&L for PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in sub base flooring 25 mm thick surface finished even and rough to receive the topping layer complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding etc (but not backing) and removing rubbish off the premises complete all as specified and directed.
M&L for Machine cut kota stone slab flooring mirror finished 18-20 mm thick (each slab not less than 0.25 Sqm) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 20 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
M&L for Machine cut kota stone in riser of steps, skirting, dado and pillar mirror finished 18-20 mm thick over cement base rendering laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab with 15 mm thick screed bed or bedding layer in cement mortar 1:4, including rubbing and polishing complete all as specified and directed.
M/L Vitrified Ceramic tiles 10 mm thick (square/ rectagular) dark/light colour shade polished,area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match as in floors over 20mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L Vitrified Ceramic tiles 10 mm thick on vertical surface of wall of size not exceeding 0.36 sqm,as in dado/skitting including 10 mm thick rendering in CM 1:4 complete all as specified and directed
M&L for Non skid ceramic coloured tiles of design as approved by GE 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles including 20 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L for Non skid ceramic coloured tiles vertical surfaces area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm as skirting non skid ceramic tiles ncluding 10 mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface 300x200x7 mm thick coloured on vertical surfaces such as dado/skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match , including 10mm thick rendering in CM 1 :4 complete all as specified and directed.
M&L for glazed ceramic coloured tiles 350 x 250 x 7 mm / 450 x 350 x 7 mm thick on vertical surface such as dado /skirting / risers to steps etc jointed in neat cement slurry and pointed in white or coloured cement to match surface of tiles over and including rendering 10 mm thick in cement mortor 1:4 complete all as specified and directed. Note- (i) The size of tiles (except thickness) may be varied during execution without any price adjustment.
M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations
Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store for 15mm bore of pipe complete all as specified and directed.
Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 20mm bore of pipe complete all as specified and directed.
Taking up & down GI steel tubing & connections including cleaning for refixing or removal to store 25mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 15 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 20 mm bore of pipe complete all as specified and directed.
Refixing old steel tubing and connections in new or old position (wall, floor, ceiling etc) of 25 mm bore of pipe complete all as specified and directed.
Supplying and laying of 15mm bore dia, CPVC pipes SDR 11 & plain CPVC SDR 11 fittings, fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed.
Supplying and laying of 20mm bore dia, CPVC pipes SDR 11 & plain CPVC SDR 11 fittings, fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed.
Supplying and laying of 25mm bore dia, CPVC pipes SDR 11 & plain CPVC SDR 11 fittings, fixed on walls/ceiling or laid in floors, etc, complete all as specified and directed.
S&F CPVC Brass elbow 15mm bore dia complete all as specified and directed
S&F CPVC Brass elbow 20mm bore dia complete all as specified and directed
S&F CPVC Brass elbow 25mm bore dia complete all as specified and directed
S&F CPVC Brass Tee 15mm bore dia complete all as specified and directed.
S&F CPVC Brass Tee 20mm bore dia complete all as specified and directed.
S&F CPVC Brass Tee 25mm bore dia complete all as specified and directed.
S&F CPVC Brass Union 15mm outer dia complete all as specified and directed.
S&F CPVC Brass Union 20mm outer dia complete all as specified and directed.
S&F CPVC Brass Union 25mm outer dia complete all as specified and directed.
S&F CPVC Brass Elbow (20/15) 20 mm bore dia complete all as specified and directed.
Dismantling PVC water tanks exc 250 ltr but not exc 500 ltr capacity and removing to store
Dismantling PVC water tanks exc 500 ltr but not exc 1000 ltr capacity and removing to store
S&F 500 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
S&F 1000 ltr capacity Rotational moulded polyethylene water storage tanks (cylin-drical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I
M&L for cleaning of water storage tank of any capacity,size,type etc. mountred on roof incl removal of all vegetation if any, loose dirt and all other materials all as directed by Engr-in-Chrg
Cutting chases in brick walls, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete.
S&F in repair bib tap cast copper alloy chromium plated with crutch or butterfly handle fixed to 15 mm dia GI tube/CPVC pipe all as specified and directed.
S&F in repair 15 mm fancy type pillar taps chromium plated cast copper alloy with capstan heads screwed down high pressure with or without lettered ‘Hot’ or ‘cold’ with long screwed shanks and fly nuts .
S&F in repair 15 mm fancy type stop valve/angle valve cast copper alloy chromium plated screwed high pressure with crutch or butter fly handle screwed both ends for iron or union and fixed to 15 mm GI tube complete all as specified and directed by Engineer-in-Charge.
S&F in repair 20mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks all as directed.
S&F in repair 25mm dia ball Brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipes or brass ferrule and fixed as in PVC Service tanks all as directed.
S & F in repairs 20mm bore gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed.
S & F in repairs 25mm bore gun metal gate valves with iron wheel head screwed both ends for iron pipe and fixed.
S&F in repairs PVC connection 15mm size with PTMT nuts, of 450mm length complete all as specified and directed.
S & F in repairs Brass chromium plated shower rose 125mm size complete all as specified and directed
S & F in repairs, vitreous china wash basin, white, flat back, size 550x400mm with brackets, inc.cutting for fixing & pinning in ends of brackets complete all as directed by Engr-in-Chrg
S&F in repairs viterious china squatting pan orissa pattern size 580x440mm white integal foot rest including concrete bedding & including P or S trap 100mm complete all as directed by Engr-in-Chrg
S & F in repairs, vitreous china wash down water closet pan (pedestal pattern), white, incl 'P' or 'S' trap and plastic water closet seat, black, closed pattern with flat bottom and cover & MS chromium plated or aluminised hinging device, complete all as directed by Engr-in-Chrg
S & F in repairs Vitreous China urinals, bowl type flat back size of 465 x 355 x 265 mm white (minimum) with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement etc complete all as sapecified and directed.
S&F in repair PVC low level flushing cistern (white) 10 Ltrs capacity with inlet, ball valve, float and handle internal fitting, push button operated type with and including brackets etc complete.
S/F in repair health faucet with flex pipe and hand shover ,the length of hose 1.50 mtr fitted to the tap.complete all as specified
S&F in repair PVC Jet connector suitable for EWC all as specified and directed by Engineer-in-Charge.
S&F in repairs EWC seat cover of any pattern including cover and Mild steel chromium plated hinging devices of any colour all as specified and directed.
S&F Grating doom 125 mm dia with waste hole of PTMT Minimum weight 40 gms complete all as specified and directed.
S/F in repair CP 2 way bib cock. make as approved by GE complete all as specified
S&F in repair CP brass towel rail `D’ type 60Cm long fixed to wall all as spd and directed by Engr-in-Charge
S&F in repair soap dish any type fixed to plugs with chromium plated brass screws complete all as specified and directed
S&F as in repair glass shelf assembly consisting of 5.5mm thick sheet 12cm wide with chromium plated bracket guard railing 60cm long complete all as specified and directed
S&F as in repair cornner glass shelf of size 9"*9" shelf and frond,circle in design fixed over chromium plated brackets of heavy duty with frond linings with glass fixed in wall with necessary screws complete all as specified and directed.
S & F in repairs LId of water tank capacity of 500/1000/2000 Ltrs including necessary cleats/clamps complete all as specified and directed.
M&L 32mm dia bore Waste fittings, brass, chromium plated for glazed ware sinks, basins, etc.with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed as in repairs
Demolition and breaking up drain pipe (salt glazed ware, AC or reinforced concrete,PVC ) set in cement mortor for any size & type complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 75 mm bore of pipe etc complete all as specified and directed.
M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints,fixed to walls of 110 mm bore of pipe etc complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with out access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 75 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) bends any radius of 110 mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 75 mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 100 mm bore complete all as specified and directed.
M&L for providing precast cement concrete louvres and jallies 35 mm thick (measured solid) including all mouldings but excluding frame in cement concrete 1:2:4 type B0 using 12.5 mm graded stone aggregates and set in cement mortar 1:4 complete all as specified and directed.
Excavating in trenches not exceeding 1.5 meter wide and not exceeding 1.5 meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil all as specified and directed.
Excavating in trenches not exceeding 1.5 meter wide and exceeding 1.5 meter and not exceeding 3meter in depth for foundation for erection of poles, stays, laying cables, stays etc and getting out in hard / dense soil all as specified and directed.
Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata
Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point
Supply/ Lay dry river sand /m -sand in trenches for cable protection all as directed. Note : Punned thickness only will be measured & Paid
M & L for graded coarse aggregate (broken stone or boulders) of size 40 mm in sub - station yard for laying all as directed and specified.
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation.
M & L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate including use and waste of form work for pole filling/ any description all as directed.
M & L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate including use and waste of form work for pole filling/ any description all as directed.
S & F in trench/on wall in repairs GI tubing light grade for road crossing and cable protection of the 80 mm dia as in repairs.
All as per item No.95 above, but size 100 mm dia
Dismantling old and unserviceable pre stressed concrete /Steel poles any type including breaking cement concrete complete, Material and erection of steel tubular swaged pole with cast iron base plate finial tapper plug, bolts nuts and screws and specified type 410-SP-55 ( 11mtr long) in truly vertical position 1.5 m length of pole above ground level shall be painted with two coats of synthetic enamel paint in strips of 30 cm width, black and yellow alternatively and painting with two coats of aluminum paint over a coat of red oxide primer on rest part of pole and its connected parts complete all as specified and directed by engir-in charge. (note- Excavation and PCC shall be measured and paid seperately )
M & L for Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 complete all as specified and directed.
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as directed.
Dismantling old unserviceable stay assy complete, material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 incl stay clamp, (loop insulator, stay wire, excavation and concrete measured seperately) complete all as directed.
S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as directed.
S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
S & F in repairs cable jointing kit for 11KV grade cable for Straight through joint heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm. (Make : 3M/Birla/Denson)
Supply & Lay , testing and commissioning in repairs XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas complete
Repairing / Servicing the Air break isolating switch HT 33 KV/11 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & paid seperately under relevant item of Sch'A' item No. 27
Supply only 33 KV/11 Airbreak switch spares all as directed Male contact / moving Contact Blade
All as per item No.111 above, but Female contact / Fix Contact Jaw
All as per item No.111 above, but Rotating contactor pipe 200A/400 A
All as per item No.111 above, but MS jumper carrier
All as per item No.111 above, but Back Connector plate
S & F in repairs lighting arrestor Zinc oxide gap less type , station class suitable for 11 KV / 65 KA complete with all fittings all as specified and directed .(Make : M/s Crompton Greaves / M/s Lamco / M/s Elpro / M/s Oblum)
M & L preparation of old painted surfaces of HT 33 MRS at GOS consisting of Steel poles / ISMBs, cross arms, GOD pipe,clamps etc., having of any description and applying one coat of aluminium paint manually all as directed complete. Note : (a) This rate inclusive of painting all minor items such as clamps, brackets, nuts, bolts and washers which is not particularly mentioned in this item. (b) This painting work will be carried out during Holidays only to avoid elect shut down.
M & L for removing vegitation, grass, scrubs and bushes growing in Sub station yard along with fancing by mannually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note :- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
S & F in repairs insulating rubber mat ISI marked of size 1 m x 2 m x19mm suitable for 11 KV at 33 KV MRS Old Air Field
Taking down carefully the existing 33/11 KV power transformer of capacity 1.6 MVA by disconnecting HT overhead connection/underground cables and earth strips etc. from MRS using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted.
Taking down carefully the existing 11KV/433 V distribution transformer of capacity 63 KVA to 315 KVA by disconnecting HT overhead connection/underground cables and earth strips etc. from any substation / locations using suitable capacity of crane or by any other method irrespective of type of approach available, loading in vehicle, transportation to workshop for repairs and unloading carefully. Reloading the tranformer after repairs and testing of transformer; transportation to site and unloading including placing at given position and re-commissioning complete all as specified and directed by Engr-in-charge. Note : All the T&P required for disonnection, connection, loading and loading including necessary petty items like bolts, nuts etc will be arranged by the contractor and rates for the same deem to be included in the rates quoted.
M & L for repairs toTransformer step down 11KV/0.433 KV any type of capacity 63 KVA to 315 KVA, after dismantling the transformer body carefully, opening the top cover of Transformer for inspection /repair, drain out the transformer oil from the tank complete, taking out the core and winding assy by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, renewal/replacement of u/s rubber bushes and washers , replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, warnishing the coil, keeping the coils in electric oven chamber for 24 hrs to remove the moisture, Painting of complete transformer body from outside and inside by weather proof type using spray gun, Marking of MES/SM Number etc, replacement of conservator tank glass, re-intalling the core and winding inside properly, making the all connection with suitable copper lugs, refilling of dehydrated transformer oil including dehydration, reinstalling the top cover after cleaning and painting of housing, conservator tank, expulsion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and directed by Engr-in-Charge. Note :- Winding wire including labour for making of coils and LT/HT bushes will be measured & paid seperately.
All as per Srl item No 122 above but of capacity 11 KV/0.433 KV, 315 KVA to 650 KVA complete all as directed.
All as per Srl item No 122 above but of capacity 11 KV/0.433 KV, 315 KVA to 650 KVA complete all as directed.
Supply and filling of fresh transformer power oil of BDV not less than 50 KV for topping up of reduced level of transformer due to evaporation/ leakage/losses due to dehydration in distribution 11 KV transformer /Distribution transformer 63 to 650 KVA or for replacement complete including removing of old unservicable transformer oil all as specified and directed.
M & L for conducting oil filtration by stream line / Vacuum type filter machine to remove the moisture/carbon particles to improve required BDV of oil 50 to 60 KV for 1 min for min for distribution transformer incl routine testing after filtration for any capacity of transformers/CT/PT units all as directed. (Note : The contractor shall change the filter assy before starting the filtration of power/ distribution transformer of any capacity in presence of Engr In charge)
Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 63KVA to 315 KVA complete.
All as per item No 127 above but LT side.
Material and labour for replacement of 33 KV bushings for capacity of 1.6 MVA 33/11 KVA transformer complete.
Material and labour for replacement of 11 KV bushings for capacity of 1.6 MVA 33/11 KVA transformer complete.
Material and labour for repalcement of 33 KV bushing stud (copper) for capacity of 1.6 MVA 33/11 KV transformer complete
Material and labour for repalcement of 11 KV bushing stud (copper) for capacity of 1.6 MVA 33/11 KV transformer complete
Material and labour for cleaning, treatment and reassembling of core for 1.6 MVA 33/11 KV transformer complete all as specified and directed
Material and labour for arching horn (33KV) double gap clamp complete all as specified and directed
Material and labour for arching horn (11KV) double gap clamp complete all as specified and directed
Material and labour for 33 KV Off load Tap switch 5 position (+5 to -10) complete all as specified and directed
Material and labour for repalcement of gasket for complete transformer all as specified and directed
Material and labour for repalcement of silica get breather for transformer 1.6 MVA complete all as specified and directed
Material and labour for dial type therometer 6 inch with DC complete for 1.6 MVA 33/11 KVA transformer
Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side transformer of capacity of 1.6 MVA 33/11 KVA complete.
Material and labour for replacement of brass terminal rod with nuts,bolts washers & bushings suitable for HT side of the transformer of any make and capacity from 315 KVA to 650 KVA.
All as per item 141 above but LT side.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 63 KVA to 315 KVA transformer.
Supply and replacing silica gel breather clear view type including first fill of good quality silica gel of capacity suitable for 315 KVA to 650 KVA transformer.
M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 63 KVA to 650 KVA (Indoor/outdoor type).
M & L for painting using spray painting the outer surface of the transformer with one coat of weather proof paint after preparing the surface dust and oil free and cleaning the bushes, name plate etc paint free after painting including writing the MES/SM No with white enamelled paint all as directed for capacity of transformer 1.6 MVA complete
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x6mm thick burried directly in ground (earth pit not less than 2.25 m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size, by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6 mm earth lead protected by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregates with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4kg/Sqm) and frame of angle iron 25x25x3 mm with lugs-02 Nos and with 6 mm dia MS bar handle made to shape, GI medium grade 20 mm bore pipe for watering perforated at bottom 1.5 meter long placed on top edge of earth plate common salt and charcoal filling, test point with fixing arrangements, funnel wire mesh and earth work in hard/dence soil returning filling in and removal of surplus soil to a distance not exceeding 50 m, all as per electrical plate No 5 of SSR-2010 Part-I and connecting to earth test point all as specified and directed.
M&L for replacement off load tap changer for distribution transformer of any make and capacity from 63-650 KVA
M&L for super enamelled copper conductor wire of suitable gauge and size including making suitable coil bobbins as per existing size and shape with proper insulating materials, spacers, warnishing as per required grade and insulatin and assembling on core, heating the same in oven as per standard procedure at appropriate temerature to obtained desired insulatin level for the power/ distribution transformer of any capacity / any make complete all as directed.
Material and labour for replacement of bush type insulator white/brown/green working pressure 433 Volts LT side all as specified and directed by Engr-in-charge.
M & L for servicing of 33 KV VCB / 11KV VCB / bus coupler by dismantling cleaning greasing the complete VCB with attached relays bus bar etc insulation testing, setting the contact gap by measuring as required reassembling the VCB and reinstalling back to its original position checking and repairing the current circuit panel wiring, replacement of new spares as required complete including operational testing and commissioning all as directed. (Note : New spares will be measured and paid separately under relavent item of this schedule)
M & L for carrying out primary & secondary injection test of 33 KV or 11 KV indoor /outdoor type current transformer (Set of three) of VCB's by using standard injection test method and checking the electrical circuits for fault condition, all relay testing and proper functioning incl submitting the test report all as directed by Engr in charge. (Note : PIT/SIT for VCB will be carried out in 6 months intervals and each primary & secondary injection test will be measured and paid)
Supply only Closing coil 24/30V DC, spares for VCB 11 KV 400 A 25 KA 250MVA as approved by GE
All as per item 153 above but Tripping coil 24/30V DC
All as per item 153 above but Antipumping device 24/30V DC
All as per item 153 above but Earth Fault and over current relay as per existing and suitable
All as per item 153 above but Digital type power factor indicator meter
All as per item 153 above but Digital type Voltmeter / Ammeter 96 x 96 mm size
All as per item 153 above but LED type indicator lamp assembly
All as per item 153 above but spout incoming side
All as per item 153 above but spout outgoing side
All as per item 153 above but Epoxy insulators bushings for incoming / out going cables / bus bar suppors as per existng size of VCBs
All as per item 153 above but Gear system assy complete with handle for charging / discharging of VCBs
All as per item 153 above but Spring charging motor for VCBs
All as per item 153 above but Over current protection relay as per existing and suitable
All as per item 153 above but Metering and protection current transformer epoxy/resin filled of 11 KV grade of ratio 100-50/5 class = 5P, 10/1 25 VA draw out type with necessary mounting and connected items.
Painting of two pole stucture consistig of 2 Nos PCC pole 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed
Painting of two pole stucture consistig of 2 Nos (Metal Strucure) 11 M height, 1 no GOS, 1 set support insulators with channels, with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code to the metal structure and cement paint to the PCC structures all as specified and as directed
Painting of four pole stucture consisting of 4 Nos pole(metal structure) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed
Painting of four pole stucture consistig of 4 Nos pole(PCC) 11 M height, 3 no GOS, 1 set Fuse with channels,1Bus bars 1 No LA etc with all connected clamps,supports etc by preparing the surface and applying two coat of syntheti enamal paint over a coat of primer as per colour code all as specified and as directed
Supply & fix replacement of silica gel complete all as specified and directed..
Supply & fixing of petroleum jelly complete all as specified and directed..
Supply & Fixing in replacement precast PCC cable route indicator duly marked and painted for HT /LT cable of size 80 x 25 x 7.5 CM with suitable size of base complete all as specified and as directed.
Supplying & laying of precast concrete cable cover, class HV, type 1 peak type size 300mmx180mmx40mm complete all as specified and directed..
S & F in repair horn gap fuse 11 kv 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed
Supply and install HT 11 KV 3 phase 50 cycles out door type air break switch suitable for horiandal/Vertical mounting fixed type complete with 9 insulators operating handle and all clamps,nuts,bolts etc of rating upto 200 Amp all as specified and as directed
M&L in repairs danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete
Supply and fixing of fuse wire tinned copper of different capacity as per ground requirement complete all as specified and directed..
M&L for cable fault locator vehicle mounted to locate fault at any type of location with one fault locate at a time complete all as specified and directed by Engr-in-Charge
M&L for in repairs aluminium conductor steel reinforced complete all as specified and directed to be used as jumpers
M & L for Cutting and trimming of tree branches 5 mtr all around of any size which is coming over the two/four pole structure of 11 KV line by using required tools and plants incl removing trimmed tree branches. (Note : Each cleaning will be measured and paid separetely)
M&L for PVC board of size 30x30 cm with letter written in stickers dully marked the incoming and outgoing cable feeder with suitable size of letters with fixing complete all as specified and directed. Note: Background of the board should be red and letters should be in white colour.
S & F in repairs incl testing of metering & protection current transformer Oil filled out door type of 11 KV capacity ratio 100-50/5 or 200-100/5 class=5P, 10/1 15 VA including dismantling old existing CT all as directed.
Dismantling old and burnt out PT unit 33000/110/220 volts oil filled out door type taking out contact with lead and bushing from the bus bar and replacing by new one of same model suitable for 11 KV PT unit incl testing on completion all as directed.
S & F in repairs cable jointing kit for 33 KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. (Make : 3M/Birla/Denson)
S & F in repair horn gap fuse 33 kv (Polymer) 200 Amps horizontal/vertical type for outdoor use including all connected accessorises complete all as specified and as directed
S&F in repair 33 KV disc insulator polymer type with hardware fittings complete all as specfied and directed
S&F in repairs power aluminium bolted type connectors to be fixed on jumpers/aluminum conductors/AB conductors of any size complete all as specified and directed
S&F in repairs of AB conductor of size 100 Sqmm with colour code (RYB) as required on ground for MRS structure complete all as specified and directed
S&F in repairs of 33 KV post insulators complete all as specfied and directed
S&F in repairs of 11 KV post insualtors complete all as specified and directed
Boring of holes horizontally for laying of 80mm dia pipe (minimum depth 0.60 Mtr from top level) under road, Pavement, hard standing complete all as specified and directed.
M&L for attending day to day breakdown complaints of any nature in high tension line after receiving complaint from complaint cell/ JE concerened and rectifying the same as soon as possibble complete all as specified and directed.
M/s Bapujee Builders and Traders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .