| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.6 LAccepted-AOC AT BAGHUABOL CHHAK PO HATATOTA TALCHER ANGUL ODISHA PIN 759100 | ANUGUL | ODISHA | 759100 | L1 | Accepted-AOC The amount quoted by L1 bidder M/s industrial engineering works is 19.52 percent below the estimated cost / the updated cost. | |
| 2 | L2₹10.1 L+₹23,982.45 (2.43%)Rejected-Finance AT GURUDWARA SOUTH BALANDA TALCHER ANGUL ODISHA 759100 | ANUGUL | ODISHA | 759100 | L2 | Rejected-Finance On being L2 | |
| 3 | L3₹11.0 L+₹1.1 L (11.0%)Rejected-Finance PLOT NO 46 SUGANDHA VIHAR NEAR NEW ERA PROGRASSIVE SCHOOL RAMPUR DIST KORBA 495677 | KORBA | CHHATTISGARH | 495677 | L3 | Rejected-Finance On being L3 | |
| 4 | L4₹11.5 L+₹1.6 L (16.4%)Rejected-Finance PLOT NO 733 BIJIPUR HOUSE NO 2 TAMANDO VILLAGE TOWN SPRINGVILLE GREEN CITY BHUBANESWAR KHORDHA ODISHA 752054 INDIA | KHORDHA | ODISHA | 752054 | L4 | Rejected-Finance On being L4 | |
| 5 | L5₹12.9 L+₹3.0 L (30.5%)Rejected-Finance AT RAMPUR COLLIERY BRAJRAJNAGAR DIST JHARSUGUDA ODISHA 768216 | BRAJRAJNAGAR | JHARSUGUDA | ODISHA | 768216 | L5 | Rejected-Finance On being L5 |
Tender Value
₹14.5 L
EMD Value
₹18,100
Closing Date
15 Mar 2024, 5:00 pmClosed
Vijay Kumar Staff Officer(EnM) Lakhanpur Area
Vijay Kumar Staff Officer(EnM) Lakhanpur Area GM Office Bandhabahal Dist-Jharsuguda Odisha-768211 Mob-9437595715
Supply, installation and commissioning of 33KV CT,PT,LA and other accessories for bay-1 and 2 for Main sub-station at Lakhanpur OCP, Lakhanpur Area
2024_MCL_303610_1
MCL/LKPA/EnM/eNIT/23-24/119 dt-04.03.2024
Open Tender
Electrical and Maintenance Works
Item Rate
75 days
Lakhanpur OCP, Lakhanpur Area
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,100
28 May 2024
4 Mar 2024
18 Mar 2024
4 Mar 2024
15 Mar 2024
5 Mar 2024
4 Mar 2024 - 8 Mar 2024
Amount
Supply and erection of 30kV, 10kA, SM – Station Medium Duty (Old Line Discharge Class – III) Polymer Surge Arrestor with Terminal Clamp for 1.65 Inch(42mm) IPS Al. Bus Tube with Insulating Base With Surge Monitor along with Connecting Lead of 2m Cu 35 Sq mm Cable, Creepage Distance: 31mm/kV (3 nos. per set) (Technical Specification mentioned in GTC)
Supply and fixing of 33KV, 1200A carrying capacity, high quality Aluminium Tubular pipe bus bar, Size- Outer dia-42mm, thickness-4mm with bus bar connector and GI Bolt, nut washer etc as required.
Supply and erection of 33KV, Outdoor, Oil Cooled, Dead Tank Type, Single Phase CT, CT RATIO: 200-100/5-5-5 A I.S.S: 2705’92, Core I: 30 VA, Accy. Cl.: 1.0, Core II : 15 VA, Accy. Cl.: 5P, ALF : 10, Core III : 15 VA, Accy. Cl.: 5P, ALF : 10, B.I.L: 36KV/70KV/170KVp, STC: 13.1 KA for 3 Sec., Creepage : 31mm/kV, Enclosure : Hot dip galvanized. (Technical Specification mentioned in GTC)
Supply and erection of 33KV, Single Phase, Outdoor, Oil cooled, Type PT with PT ratio : 33KV/√3/110V/√3 , I.S.S: 3156’92, Burden : Wdg 1 : 100 VA , Accy. Class : 3.0, V.F : 1.2 cont & 1.5 for 30 sec., B.I.L:36KV/70KV/170KVp, Creepage : 31mm/kV, Enclosure : Hot dip galvanized.(Technical Specification mentioned in GTC)
Supply and erection of Powerpack with AC Input Voltage: 110/230 VAC, 1ph, 50 Hz., DC Output-1: 110VDC, 40 WSec [Stored], DC Output-2: 110VDC, 100 Watt [Non-Stored], Insulation Test [Routine Test]-2500V AC RMS, 50 Hz, for 1 Second is applied between Earth & All Terminals [as per IS 3231:1965, Clause 10.5]. Unit withstands the same. (Technical Specification mentioned in GTC)
Primary injection test of 33KV outdoor Dead Tank Type, Single Phase CT, CT RATIO: 200-100/5-5-5 A of main substation. Test report to be submitted.
Total impact of GST plus Labour Cess [@ 1 % (BOCW Cess to be deducted from the RA bill as per the value of the work progress)] for the purpose of CTC
M/S. R.K. TRADING AGENCY
Pioneer Enterprises
UNIVERSAL PROJECT AND MAINTENANCE
M/S LIGHT PALACE
M/s Evergreen Electrical Works
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .