| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC OPPOSITE GHOOM DRC PO GHOOM DISTT DARJEELING WB PIN 734 102 | DARJEELING | WEST BENGAL | 734102 | L1 | Accepted-AOC L1 BIDDER | |
| 2 | L2₹15.9 L+₹72,744 (4.78%)Rejected-Finance | L2 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 3 | L3₹16.8 L+₹1.5 L (10.2%)Rejected-Finance | L3 | Rejected-Finance HIGHER THEN L1 BIDDER | |
| 4 | L4₹17.2 L+₹2.0 L (13.2%)Rejected-Finance NEAR PAYAL CINEMA P O SEVOKE ROAD SILIGURI 734 001 | DARJEELING | WEST BENGAL | 734001 | L4 | Rejected-Finance HIGHER THEN L1 BIDDER |
Tender Value
₹14 L
EMD Value
₹28,000
Closing Date
22 Oct 2022, 6:00 pmClosed
CWE
HQ 136 WORKS ENGINEERS PIN - 914136 C/O 99 APO
REPAIR/MAINT OF HT INSTALLATION HT VCBS HT CABLES AND DISTRIBUTION TRANSFORMERS AT JALAPAHAR UNDER AGE (I) DARJEELING
2022_MES_553439_1
CWE/136-WE/36 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Darjeeling
Class E, Category b(ii)
8 documents required · 8 mandatory
₹500
AGE (I) Darjeeling
₹28,000
18 Nov 2022
21 Sept 2022
24 Oct 2022
21 Sept 2022
22 Oct 2022
7 Oct 2022
21 Sept 2022 - 28 Sept 2022
Amount
Material and labour in repair for mechanically gang operated air break switch 11KV mounted on 12 nos. insulator and steel frame with operating mechanism worked from ground level complete with drop out fuse (set of three) of rating 400 amps.
Servicing / calibration / trouble shooting / repairing / adjustment of over current relay, earth fault relay, Spring, spring charge mechanism, close coil, trip coil, including connected accessories cleaning of all contacts with CTC, of the 11KV HT VCB panel of 630A, 50 Hz by qulified technical personel to make functional in all respects including identifying the deffective parts.
Supply and fixing following spares in repairs suitable for 11KV HT VCB of maximum short circuit current rating 25/26.3 KA 630A/400A after taking down the old spares all as specified and directed.-
LED indicating lamps R/Y/B
LED indicating lamps amber
LED indicating lamps white
Trip circuit push button with NO contracts.
Limit switch
Tripping Coil assembly
Closing Coil assembly
Gear Assembly
PT fuse
12NO + 12NC auxiliary Contact
Space heater
Thermostat
HRC control fuse 2A, 4A, 6A 10A
Holding catch assembly
Breaker controler Switch
ON/OFF push button plate assembly
Breeze rectifier
Fuse base with carrier
Test & service Limit switch
Single phase power pack with capacitor backup, 110V DC
Spring Charge motor coil Supply 230V AC
Space Heater
Earthing complete with galvanized steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth strip 32 x 6 mm (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no 3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia 150mm long reinforcement, watering funnel, 40 mm dia light grade for protection of earth electrode 20 mm dia for watering all as specified and directed and tested on completion all as specified and directed.
Disconnecting and removing transformer from mounting platform/structure after disconnecting HT/LT side cable connections, draining out transformer oil for repair/periodical maint of transformer of following capacity all as directed by Engr - in- Charge.
BLANK
50 KVA to 100 KVA
150 KVA to 200 KVA
250 KVA to 350 KVA
400 KVA to 500 KVA
Disconnecting and removing transformer from mounting platform after disconnecting HT/LT side cable connections and transporting of unserviceable transformer for rewinding from MES sub station to contractors/civil workshop and vice versa by arrangement of necessary crane for taking down loading / unloading and refixing at site of following capacity all as specified and directed.:-
50 KVA to 100 KVA
150 KVA to 200 KVA
Opening the top cover lid and taking out the core with winding by means of Crane/Chain Pulley without any damage to core and winding after disconnecting all internal connection of coil with outgoing/incoming terminals and keeping aside for periodical maint such as cleaning of transformer core and winding, cleaning of oil tank, repair/replacement of unserviceable /Burnt parts of following capacity all as specified and directed by Engr -in-Charge.
50 KVA to 100 KVA
150 KVA to 200 KVA
250 KVA to 300 KVA
400 KVA to 500 KVA
Periodical maint of transformer such as cleaning of core and winding by means of washing by hosing down with clean dry oil to remove dust/sludge on core and coil, including cleaning of oil tank to remove sludge deposit, replacement of rusted gasket set, burnt spindle, broken/unserviceable HT and LT ceramic bushing , broken arc horn surge arrester, replacement of silica gel for transformer of following capacity all as specified and directed by Engr-in-Charge.
50 KVA to 100 KVA
150 KVA to 200 KVA
250 KVA to 300 KVA
400 KVA to 500 KVA
Note for iteam No 42.00 to 45.00: (i) Cost of Transformer oil for cleaning by hosing down shall be deemed included in the rate quoted. (ii) Gasket set, LT/HT side ceramic bushing, spindle for HT/LT side and arc horn surge arrester for replacement shall be measured and paid under relevant item
Re-fixing of transformer core and windings by means of Crane/Chain Pulley without any damage to core/windings including re-filling/ topping up dehydrated new transformer oil after carrying out the maintenance/repair and making internal connection on LT/HT side and re-fixing of top lid cover, installing on mounting platform, making connections with HT/LT feeder and testing on load for transformer of following capacity all as specified and directed by Engr-in-Charge.
50 KVA to 100 KVA
150 KVA to 200 KVA
250 KVA to 300 KVA
400 KVA to 500 KVA
Note for item No 48.00 to 51.00 :- New transformer oil for topping up shall be measured and paid under relevant item. The dielectric strength of the same shall be tested by contractor before filling in transformer.
Rewinding of transformer of under mentioned capacities by super enameled copper wire as per existing guage of primary coil with `E’ class insulation, varnishing and heating the coil properly, fixing on core and making connection to achieve rated voltage and current of followings all as specified and directed by Engr-in-Charge.
50 KVA to 100 KVA
150 KVA to 250 KVA
Rewinding of transformer of under mentioned capacities by super enameled copper wire as per existing guage of secondary coil with `E’ class insulation, varnishing and heating the coil properly, fixing on core and making connection to achieve rated voltage and current of followings all as specified and directed by Engr-in-Charge:-
50 KVA to 100 KVA
150 KVA to 250 KVA
Supply only brass spindle for terminal on HT side threaded complete with nut, washers etc of suitable dia for transformer of following capacity all as specified and directed. :-
63 KVA to 100 KVA
150 KVA to 250 KVA
300 KVA to 500 KVA
All as per item No 59.00 here-in-before but for LT side of transformer of following capacity all as specified and directed.:-
50 KVA to 100KVA
150 KVA to 250 KVA
300 KVA to 500 KVA
Supply only ceramic bushing on LT side of transformer of following capacities all as specified and directed.
All as per item No 67.00 here-in-before but for HT side of transformer of following capacity all as specified and directed. :-
Supply only gasket set for transformer top lid cover, LT and HT terminal bushing suitable for transformer of following capacity all as specified and directed. :-
50 KVA to 100KVA
150 KVA to 200 KVA
250 KVA to 300 KVA
400KVA to 500 KVA
Supply and fixing Lightning arrestor suitable for HT12 KV Zinc Oxide valve element type (ZnO) 5 KA rms class E as per IS 3070 (PT.3 1993, IEC 99-4/1991 il with all fitting for outdoor use, Including Disconnecting and taking out existing unserviceable lightening arrestor complete .
Dehydration/filtration of transformer oil by means of centrifugal filtration plant to achieve the specified dielectric strength of 35 to 40 KV at 2 mm gap in existing possession of transformer of any capacity and transformer oil for topping up at various sub-station all as specified and directed by Engr-in-Charge.
Supply only transformer oil of approved quality having dielectric strength not less than 60 KVA, tested in 4.0mm gap, IS marked (Make: Savita/Poweroil) for filling in transformer for topping up all as specified and directed by Engr-in-Charge.
M&L for pin type grey polymer insulator in repair including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 11000 Volts grade.
M&L for disc type grey polymer insulator in repair including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut suitable for 11000 Volts grade.
M&L for sand filling spreading, levelling in layers including watreing and consolidation complete all as specified and directed.
M&L and labour for spreading and levelling of unbroken river stone aggregate for loose filling of guage 40mm to 80mm graded complete all as specified and directed.
Supply & laying Electrical rubber mat 1mx2m of 11 KV grade (3.0 mm thick) made of highly electrical resistant elastomer complete all as specified and directed.
Supply & laying Electrical rubber mat 1mx2m of 33 KV grade (2.0 mm thick) made of highly electrical resistant elastomer complete all as specified and directed.
Note 1:- (Applicable for all parts/items) : The biidders/contractors are advised to read tender document, all drawings & all corrigendum/ amendments and general condition of contracts before entry/quoting the rates. Note 2:- Attention to bidder is hereby invited to upload revised BOQ if published during their bid submission. Uploading of incorrect/ pre-revised BOQ shall be treated as non bonafide and rejected.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .