| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.4 LAccepted-AOC | L1 | Accepted-AOC Being 1st lowest | |
| 2 | L2₹9.6 L+₹16,018 (1.69%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹11.5 L+₹2.0 L (21.3%)Rejected-Finance PB NO 809 ABERDEEN BAZAR PO ATLANTA POINT NEAR POLICE WIRELESS PORT BLAIR 744104 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744104 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹11.7 L+₹2.2 L (23.4%)Rejected-Finance 94A APR COLONY BILHARI JABALPUR MP | JABALPUR | MADHYA PRADESH | 482020 | L4 | Rejected-Finance Other than lowest | |
| 5 | Rejected-Technical | - | Rejected-Technical Not enlisted in app cat |
Tender Value
Refer Docs
EMD Value
₹19,000
Closing Date
26 May 2021, 6:00 pmClosed
GE(I)866EWS CARNICOBAR
GE(I)866EWS CARNICOBAR
SPL REPAIR TO FALSE CEILING AND PROVN OF STREET LIGHT AT JAWAHAR NAVODAYA VIDYALAYA AT CARNICOBAR
2021_MES_440466_1
8501/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
AREA UNDER GE(I)866EWS CARNICOBAR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE(I)866EWS
₹19,000
Yes
17 Jun 2021
5 May 2021
2 Jun 2021
5 May 2021
26 May 2021
19 May 2021
Amount
Dismantling of ceiling boards (fibre, pulp, insulation etc.) or insulation boards / slab /blankets, any description/thickness, including cover fillets complete all as directed by Engineer in Charge.
M&L for providing aluminium snap grid frame (with minimum 15 micron uniform anodic coating) , size of grid 605x605mm consisting of Tee/Angle section, size 40x40x2mm as approved conforming to IS:733 in frame of false celing, including necessary cleats with CO brass/Stainless Steel shunk scrwes. Alumnium peremeter angle fixed to wall /wooden frame at centre to centre and fixing frame to level adjusting with 8mm dia GE wire hook in Tee member at 1.5mtr centre to centre ficed to steel truss roof complete all as specified & directed by Engineer in Charge.
M&L for 4mm thick non asbestos fibre building boards fixed or laid / inserted to alumnium grid frame work in ceiling complete all as specified & directed by Engineer in Charge.
Supply & Fixing of LED street light new generation energy saving and envirnmental long life made up of pressure die cast alumnium housing with high power LED as lighting source and lens embedded PC Cover having top oening seperete drive compartment with IP66 protection and impact resistance of IK07 with 10KV built in surge protection device of capacity 45W with connection wire of suitable size complete of Cat Part No: ENDURACITYLINERNEXGENSL45WLED757SASYBOPC of Havels or equivalent model in Crompton greaves/ Philips as approved by GE.
Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr depth for laying of pipe in soft/loose soil and getting out complete all as directed by Engineer in Charge.
M&L for PCC (1:3:6) type C2, using 40mm graded stone aggregate as in foundations, filling as mass concrete all as directed by Engineer in Charge.
M&L for PCC (1:2:4) type B2, using 40mm graded stone aggregate as in foundations, filling as mass concrete all as directed by Engineer in Charge.
M&L for galvanised iron pipe, medium grade 80mm dia , including necessary fittings, fixed in position complete all as directed by Engineer in charge
Supply and laying of DWC pipe of size 50/38mm for cable protection complete all as specified
M&L for preparation of new steel surface of any description not otherwise described over 10 cm in width or girth and applying two coat of synthetic enamel paint complete all as specified & directed by Engineer in Charge
M&L for preparation of new steel surface of any description not otherwise described over 10 cm in width or girth and applying two coat of synthetic enamel paint complete all as specified & directed by Engineer in Charge
Supply andlaying of PVC insulated XLPE alumnium conductor armoured cable 1100 volt of 6Sqmmx4 core including connecting lugs all as specified & directed by Engineer in Charge.
Returning filling in and including spreading levelling, watering and well ramming excavated soil in layers not exceeding 25cm thick each, all as directed by Engineer in Charge.
Removing excavated soil (soft/loose) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5mtr above from starting point all as directed by Engineer in Charge.
M&L for MCB SP, 5 amp with PVC Box including clamp & nut bolts all as directed by Engineer in Charge.
SKY GROUP
Chandra Construction Enterprises
Ravi Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .