Loading…
Loading…
Tender Value
₹1.2 Cr
EMD Value
₹1.2 L
Closing Date
13 Jul 2026, 6:00 pm3d left
CEO
BHOPAL SMART CITY DEVELOPMENT CORPORATION LIMITED
MISCELLANEOUS ELECTRICAL WORKS AT VARIOUS PLACE AT BHOPAL CITY BMC LIMITS UNDER SMART CITYDEVELOPMENT CORPORATION LIMITED PHASE 05 (Fifth Call)
2025_UAD_459308_5
MPBSCDCL /TENDER NO- 308
Open Tender
Electrical Works
730 days
UNDER SMART CITYDEVELOPMENTCORPORTION LIMITED
Please refer tender documents
4 documents required · 4 mandatory
₹10,000
₹1.2 L
BHOPAL SMART CITY DEVELOPMENT CORPORATION LIMITED
29 Jun 2026
29 Jun 2026
14 Jul 2026
29 Jun 2026
13 Jul 2026
29 Jun 2026
6 Jul 2026
MISCELLANEOUS ELECTRICAL WORKS AT VARIOUS PLACE AT BHOPAL CITY BMC LIMITS UNDER SMART CITY DEVELOPMENT CORPORATION LIMITED – PHASE 05 (Fifth Call)
Name of the Bidder
Revised Financial Bid Sheet
Sr.No. Sub-Head Section/Discipline Amount in Rs.
1 SH-I UADD_Electrical
2 SH-II PWD_Electrical
3 SH-III NON SOR
"Instructions to the Bidder"
1 Bidder can qoute there rates in the highlighted yellow spaces provided
2 Bidder should write name of his firm/company in the highlighted yellow space provided
3 Rates should be qouted including all the taxes and excluding GST.
4 Bidder should qoute rate in DSR sheet on % basis and in NON SOR the rate should be qouted item wise
5 If any Bidding sheet or Bidding Excel cell is left empty then it will be considered as zero (zero rupees)
NAME OF BIDDER-
S.NO. UADD SOR Item No. Items/particulars Unit Rate Quantity Amount Quote should be in percentage higher or below on the SOR Rates the same is to quoted in the form of decimal only. (For example if contractor wants to quote 5 percent higher than he have to quote 1.05 and if he wants to quote 5 percent below he have to quote 0.95 and so on....)
1 13.13 Erection of steel tubular or steel rail pole or H-Beam of length exceeding 8 meters but not exceeding 10 meters in cement concrete 1:3:6 (1 cement : 3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation, base padding & muffing including exacavation and refilling etc. as required.(4.55 bags of cement/cmt.) Each 1681 42 1
2 13.14 Erection of steel tubular or steel rail pole or H-Beam of length exceeding 10 meters but not exceeding 13 meters in cement concrete 1:3:6 (1 cement :3 coarse sand: 6 graded stone aggregate 40mm nominal size) foundation , base padding & muffing including excavation and refilling etc. as required.(4.55 bags of cement/cmt.) Each 1855 100
3 0.9 Supply of support for overhead line RS joist / H-beam of I.S. standard including welding, drilling of required hole etc. complete as required.
2 R.S. Joist 175 x 90 - 19.3 kg per meter M 897 600
6 H-Beam 152x152mm , Std weight 37.1 kg per meter M 1810 600
4 13.58 Supplying of angle/channel flat iron fitting for overhead lines such as cross arms, clamps, brackets, welding and other necessary materials as per specifications. Kg. 48 15000
5 13.23 Supplying and erection of stay set complete (Galvanized) with 19mm.dia 1.8 meter long stay rod, ancher plate of size 300mm x 300mm x 6.4mm thimble stay clamps, bow tightener, 7/4.00 dia G.I. stay wire and strain insulator etc. in cement concrete 1:3:6 (1 Cement : 3 Coarse and : 6 granded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required. Each 1895 20
6 15.13 Supplying, installing, testing of earth Coil (coil of 115 turns of 50mm dia, and 2.5 Mtrs. Lead of 4 mm G.I wire. EA 241 140
7 0.9 Supplying and drawing of stranded Aluminium Conductor Steel Reinforced (ACSR) confirming to IS:398-1976 of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connecting etc. as required and clearing of obstacles (if any) etc.
8 ACSR 6/1 - 4.09mm dia (Raccoon) with equivalent copper area 48 Sqmm (0.075 sq inch) equivalent calculated Aluminium area 77.83 Sq.mm. Km 79028 20
8 13.61 Supplying and erection of galvanised stay set for 11kV overhead line complete with 19/20mm dia x 1.8 meters long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle (20mmx 600mm), 7/4.00mm dia G.I. stay wire and 11kV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm. nominal size) foundation including excavation and refilling etc. as required. Set 2038 20
9 13.62 Supplying and erection of galvanised stay set for 33kV overhead line complete with 19/20mm dia x 1.8 meters long stay rod, anchor plate of size 45cm x 45cm x 7.5mm thick, thimble, stay clamps, turn buckle (20mmx 600mm), 7/4.00mm dia G.I. stay wire and 33kV strain insulator etc. in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm. nominal size) foundation including excavation and refilling etc. as required. Set 2050 16
10 13.68 Supplying of channel iron 75mm x 40mm x 7.14 kg/Mtr. V- shape cross arm for two 11 kV overhead line conductors complete with 50 mm x 6mm M.S. flat iron clamp, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. and painting with primer and finish paint as required. Each 1067 100
11 13.69 Supplying of channel iron 75mm x 40mm x 7.14 kg/Mtr. Vshape cross arm for two 33 kV overhead line conductors complete with 50 mm x 6mm M.S. flat iron clamp, bolts and nuts including drilling holes for insulator pins, bolts and nuts etc. and painting with primer and finish paint as required. Each 1209 50
12 13.7 Erection of pole top/straight two wire/V-shape two wire/angle iron/channel iron, Cross arm on steel tubular/Rail/Channel iron/PCC pole for 11kV/33kV as required. Set 200 200
13 13.84 Supplying and erection of three piece nonlinear resistor type lighting arrestor suitable for 3 wire, 11kV overhead lines with rated voltage of 9kV (rms) with a nominal discharge current rating of 5 KA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washer etc. as required. Set 1442 10
14 11.35 Providing and fixing earthing arrangement with 38.1mm dia 2.5 meter long galvanized iron pipe electrode including packing of charcoal powder and salt as per specification watering pipe 19mm dia G.I. Connection etc. complete with refilling the pit as required, but excluding the excavation of earth pit. Each 970 17
15 0.0 Supplying and laying 25mm X 5mm G.I. strip at 0.5 meter below ground level as strip earth electrode including soldering etc. as required. Meter 59 1575
16 0.9 Supply of XLPE Insulated power cable (conforming IS-7098 ) 1100 Volt grade/Heavy duty power cable conforming to IS 1554-1100 Volts grade , 2 core /3½ core/4 core ISI MARKED with Alu. Stranded /solid conductor
14.1.2 ARMOURED 2 Core
4 10 Sq.mm.(XLPE) M 75 500
17 14.1.6 ARMOURED 3½ CORE
2 35 Sq.mm(XLPE) M 168 500
4 70 Sq.mm(XLPE) M 297 500
7 150 Sq.mm.(XLPE) M 531 200
18 14.1.8 ARMOURED 4 CORE
2 10 Sq.mm.(XLPE) M 99 500
3 16 Sq.mm.(XLPE) M 113 500
4 25 Sq.mm(XLPE) M 153 500
19 14.1 CABLE LAYING
7 Laying of one number PVC insulated and PVC sheathed power cable of 1:1 kV grade of size not exceeding 25 Sq.mm in the existing RCC Hume/Stone/Ware/G.I. pipe as required. M 32 600
11 Laying of one number PILC/PVC insulated and PVC sheathed power cable of grade exceeding 1.1kV but not exceeding 11kV of size not exceeding 120 Sq.mm direct in ground including excavation sand cushioning, protective covering and refilling the trench etc. as required. M 103 600
20 15.3 Supplying installing and testing of AB isolating switch assembly set gang operated suitable for 11/0.4 KV, DP structure with brass part contacts, operating rod with required GI pipe, handle locking arrangement on On-Off position conforming to IS complete with required material and installing on existing structure to complete the job as required as per specification.
21 15.4 Supplying, installing ,testing of 11 KV D.O. fuse assembly with brass part contact for 11/0.4 KV DP structure set of 3 with fuse with barrel with required fuse element & other materials as per specification on existing D.P. structure as required.(set of 3nos.)
22 8 Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase, 3 pole, 50 Hz, 415 Volts, AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS - 8828
8.2 MCCB with Breaking Capacity 35 KA at 415 V
2 Current Rating -200 Amps & Adjustable: 70% -100% thermal & 5-10 times magnetic setting Each 11111 5
3 Current Rating -250 Amps & Adjustable: 70% -100% thermal & 5-10 times magnetic setting Each 13740 5
23 15.7 (i)Supplying, installing, testing and commissioning of LT Distribution Box with TPN isolator 200 amper on incoming, bus bar and 66 S.P.M.C.C.B.of 60 A" .on outgoing side for 63 KVA transformer Each 14111 2
(i)Supplying, installing, testing and commissioning of LT Distribution Box with TPN isolator 200 amper on incoming, bus bar and 6 S.P.M.C.C.B.of 90 A" .on outgoing side for 100 KVA transformer Each 14702 2
(i)Supplying, installing, testing and commissioning of LT Distribution Box with TPN isolator of 600 amper on incoming, bus bar and 6 S.P.M.C.C.B.of 120 A".on outgoing side for 200 KVA transformer Each 26523 2
24 8.5 Supplying of ISI Marked and accepted standard of Miniature Circuit Breaker (MCB) of 'C' series suitable for 240/415 Volts, 50 Cycle, 10 kA Value AC supply confirming to IS : 8828 : 1996, IEC : 60898:2002 but without enclosures :-
8.5.2 SINGLE POLE & NEUTRAL(SPN)
2 6 Amp to 32 Amp Rating Each 235 10
8.5.5 FOR TRIPLE POLE & NEUTRAL(TPN)
2 6 Amp to 32 Amp Rating Each 532 5
8.5.6 FOUR POLE(FP)
4 50 Amp to 63 Amp Rating Each 827 4
Supplying & fixing pin terminal lugs as per ISS specification suitable for cable evently cramped with high pressure tool & connection to switch gear terminal.
1 Aluminum Lugs Pin Type
a Upto 16 Sq.mm Conductor Size Each 4 42
b Upto 25 Sq.mm Conductor Size Each 7 30
c 35 Sq.mm Conductor Size Each 9 21
26 17.4 Supplying and installing Double wall corrugated pipes (DWC) of HDPE ( IS 14930 Part II -marked ) for cable laid under ground with necessary connecting sockets/ couplings,tees of same material and at required depth upto 90cm. below road/ground surface,including excavation, back filling with excavated material with ramming and making the surface good.
1 50.00mm outside dia. Mtr 178 100
27 13.8 Supplying and drawing guard wire/earth wire/bearer wire 13mm2 (4mm. Dia) G.I. including stringing, binding at existing insulators or brackets, jointing, jumpering, connecting etc. as required and clearing of obstacles (if any) Km 8986 1
28 9.15 Supplying, fixing,testing & commissioning wall / floor mounted LT Panel primer coated with two coat of enamel paint & provided with required gasket for dust/ vermin proof with degree of protection IP42 suitable for 415V 3 phase ,50 Hz ,4 wire system fabricated out of CRCA sheet upto 2 mm thick (1.6 mm for doors) with frame work of angle iron/ channel/ bolted type construction duly compartmentalised for incomer,bus section , outgoings ,cable alleys & CT,PT Ampere Meter ,Volt Meter , selector switches,Frequency Meter ,phase indicating lamps , energy Meter complete including cost of busbar supports,detachable cable gland plates,2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs ,panel mounted Changeover switch/SFUs, etc. as required but excluding cost of busbar strips,Ampere Meter, Volt Meter, Selector switch as per approved design & specification Kg 84 800
29 9.16 Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per specification
4 Copper Bus bar strips with PVC sleeves Kg 533 50
5 Aluminium bus bar strips with PVC sleeves Kg 156 50
6 LED lamp indicator Each 194 25
30 16.7 Designing & casting with M-20 cement concrete foundation suitable for 9 mtrs. Octagonal poles considering the safe soil bearing capacity at site as 10 T/sqm at 2 mtrs. Depth including excavation, foundation nut bolts in an approved manner. Each 16145 26
31 16.3 Providing and erecting 9 mtrs. High hot dipped galvanized octagonal poles with bottom of 200mm A/F, top 100mm, A/F made from 3mm thick HT plate & 290x290x16mm base plate with 1500mm long decorative sword type double arm bracket complete ererted in an approved manner on provided foundation. Suitable size & type of foundation bolts. 4 nos. bolts type M20x750mm 'J' type foundation bolts (EN8 grade) Each 31094 21
32 17 Suppying & installing G.I. Pipe for protection of underground cable fixed on wall/support/in trench/fixed between two rigid existing support of wall/beam for erection of ceiling Fan/down rod for stiff pendent for light luminaries /fan/protective for earthing, lightening conductor down strip/everhead service line/for submer cable or centrifugal pump for water supply with necessary iron clamp coupler, bend, te, elbow, nuts and bolts etc. complete in an approved manner as required to complete the job excluding cost of excavation/dismateling & other finished masonary Item complete.
17.1 For 'B' Class G.I.pipe ISI Marked (IS-1161-68)
17.2 A' Class G.I.Pipe ISI Marked (IS-1161-69)
3 50.00mm Meter 243 49
33 14.4 Providing & Making cable end termination with HEAT SHRINKABLE jointing kit complete with all accesories including lugs suitable for 33 kV/11 kV 3 core XLPE alum. conductor cable as required as per specification andas per accepted standard complete.
14.4.1 Heat shrinkable joint,kit 33 kV XLPE
1 Heat shr.jointg. kit 33 kV XLPE cable O.D. termination
a. 3x50 Each 32898 5
2 Heat shrinkable joint. kit 33 kV XLPE cable I.D. termination
a. 3x50 Each 23318 5
14.4.2 Heat shrinkable joint,kit 11 kV XLPE
1 Heat shr.jointg. kit 11 kV XLPE cable O.D. termination
c. 3x95 Each 30559 5
2 Heat shrinkable joint. kit 11 kV XLPE cableI.D. termination
c. 3x95 Each 18831 5
34 14.5(B) Cable Jointing
14.5.1 Straight through cable jointing kit including compound, hardener, plastic mould with other accessories for the following aluminium conductor PVC insulated and PVC sheathed cable//XLPE of 1.1 kV grade:(I.D./O.D.)
a. 6-16 sqmm 2 / 3 / 3½ / 4core Each 990 5
14.5.2 Supply and making Heat shr.jointg. kit 1.1 kV XLPE/HD cable straightthrough jointing.kit complete with all accessories including lugs etc. (I.D../O.D.)
a. 6-16 sqmm 2 / 3 / 3½ / 4core Each 2600 3
MISCELLANEOUS ELECTRICAL WORKS AT VARIOUS PLACE AT BHOPAL CITY BMC LIMITS UNDER SMART CITY DEVELOPMENT CORPORATION LIMITED –PHASE 05
Name of the Bidder:
S.N. Description UNIT Rate TOTAL AMOUNT (Rs) Bid to qouted 1 plus % above or below( for example: If want to qoute 5% above the write 1.05 and if want to qoute 5% below then write 0.95)
MP PWD 42.7 Supplying, drawingand testing of XLPE insulated covered aluminium conductor of approved make, stringing, making off complete with binding at existing insulator, jointing, jumpering, tearing off, connectingetc. as requiredandclearingofobstacles (if any) etc. 0.00_
0.0 70 Sqmm XLPE 11KV grade K KM 541000 541000
1.1 99 Sqmm XLPE 33KV grade KM 679000 679000
Name of the Bidder:
MISCELLANEOUS ELECTRICAL WORKS AT VARIOUS PLACE AT BHOPAL CITY BMC LIMITS UNDER SMART CITY DEVELOPMENT CORPORATION LIMITED –PHASE 05
S.N. Description Quantity UNIT Rate TOTAL AMOUNT (Rs) Bid to qouted 1 plus % above or below( for example: If want to qoute 5% above the write 1.05 and if want to qoute 5% below then write 0.95)
1 Supply installation Testing commisioning of 6.3m height Side pole with 6m cantilever arm, inculding foundation and earthing as per attached drawing 13 No 65000 0.00_
2 Supply installation Testing commisioning of 6.3m height Side pole with 8m cantilever arm. Inculding foundation and earthing as per attached drawing 6 No 95000
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
rfp.pdf
Tender Documents • 0.98 MB
Revisedfinancialbid.xls
Other Document • 0.64 MB
Download all tender documents and submit your bid