Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 CrAccepted-AOC 304 | DHANBAD | JHARKHAND | 818142 | ₹2.3 Cr | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹2.4 Cr+₹7.5 L (3.21%)Rejected-AOC P J B ROAD PRASANTI APPARTMENT 103 P O CHEMIKUTHI PS CHANDMARI DIST KAMRUP M ASSAM | KAMRUP M | ASSAM | ₹2.4 Cr+₹7.5 L (3.21%) | L2 | Rejected-AOC L2 bidder |
| 3 | L3₹2.5 Cr+₹14.9 L (6.39%)Rejected-AOC WARD NO 03 P O SONARI P S SONARI DIST CHARAIDEO ASSAM PIN 785690 | CHARAIDEO | ASSAM | 785690 | ₹2.5 Cr+₹14.9 L (6.39%) | L3 | Rejected-AOC L3 bidder |
Tender Value
₹2.3 Cr
EMD Value
₹4.7 L
Closing Date
26 Nov 2019, 2:00 pmClosed
Managing Director, ASWC
Pannyagar Bhawan, Amarabati Path, Christian Basti, GUWAHATI, 781005.
Project for renovation of Existing warehousing in 13 warehouse complexes in 10 Districts and Construction of 04 new Warehouses at 04 warehouse complex in 03 Districts.
2019_CD_14680_1
AWC.ENGG.475/2017/Tender/94
Open Tender
Civil Works
Item Rate
365 days
Hijuguri, Tinisukia
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
CD
₹4.7 L
Yes
O/o the Managing Director, ASWC
24 Jan 2020
7 Nov 2019
26 Nov 2019
7 Nov 2019
26 Nov 2019
7 Nov 2019
15 Nov 2019
Amount
RETROFITTING WORKS,
Chipping and breaking / cutting of loose concrete, mortars etc. using electrical chipping hammers to the satisfaction of the Engineer-in charge for successful execution of the subsequent rehabilitation works at all heights with all leads, lifts etc complete with all tools and machineries required for the job , operator, applicator, labour, scaffolding for staging and supervision etc.
Providing and applying two coats of NitozincPrimer a two component epoxy zinc rich primer/ sika top Aarmatec- 108 or equivalent product on the properly cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface as per the manufacturer's specifications.
Before laying of the Micro Concrete, the substrate shall be coated with a bonding agent, Nitobond EP Std. / Sikadur -32 LP or equivalent product and the micro concrete shall be poured within 6 hrs/ 4 hrs or as applicable of the application of the bonding agent.
Providing and placing free flow micro concrete Renderoc RG / Sika Micro - concrete-2 or equivalent product of after fixing slurry tight shuttering. The micro concrete should be mixed mechanically while maintaining water, powder ratio of 0.16 strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer- in -Charge.The micro concrete should develop a compressive strength of 10N/mm2 within 1 day, 40N/mm2 within 7 days and 50N/mm2 within 28 days.The cost is inclusive of materials, transportation, labour, taxes etc. all completre.
Drilling 12mm diax100 mm hole into the concrete surface using concrete hammer drill machine.Providing 10mm PGMS nozzles in a grid of 0.25m both and injecting with high strength cementitious grout- Cebex 100/ sika Intraplast EP or equivalent product till completion and refusal of grout complete as per manufacturer's specifications. The nozzles are to be sealed off after grouting using Renderoc Plug / Sika - 2 mortar or equivalent product injection with high strength cementitious grout-Cebex 100/ Sika intraplast EEP or equivalent product of Fosroc Complete as per the Specifications of the manufacturer.
Providing and applying two components epoxy resin based moisture intensive low viscous Sikadur-53 UF for high pressure injection grout with drilling & fixing of nozzle at 0.30 mt centre to centre as per manufacturer specification. The cost is inclusive of material, labour, tools & tackles etc all complete.
Crack openings should be chiselled out to approximately 20 mm x 20 mm , and should always be undercut to avoid formation of a" V" shape and cut back to a minimum depth of 15 mm and given a good mechanical key to apply Renderoc Plug / Sikadur-31 or equivalent product based per manufacture's specification.
Providing and applying Nitobond SBR Latex / Ska Latex or equivalent priming coat followed by placement of renderoc S2/ sika top 122 or equivalent high build light weight polymer modified morter to give a composited thickness of 100. The Mortar should be mixed mechanically white maintaining water powder ratio strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer-in-charge. The cost is inclusive of materials and application and exclusive of scaffolding
REPAIRING WORKS,
Taking out from position and repairing steel window shutters including steel frames at all levels after cutting out the heavily rusted and damaged portion of the shutters and frames and welded with the new 'Z' section of steel members, corner, hinges, stay etc. including fitting and fixing in position and riveting with new rivets adjusting, cleaning, cutting the holes and making good the damages to metal with existing one. Window grills to be removed during carrying out the work and to be re-fixed in position after completion of work. The glass panes damaged during execution should also be changed.
DISMANTLING AND DEMOLISHING
Demolishing plain cement concrete including disposal of debris as directed for all levels
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Extra for cutting reinforcement in RCC or RB work at all levels (Payment to be made on cross sectional area of RCC or RB work obtained by multiplying the length of the cut reinforcement and thickness of the member).
Extra for scraping, cleaning and straightening reinforcement from RCC or RB work at all levels
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling steel work in single sections (R.S.Joists, channels, angles, tees and flats etc.) including dismembering and stacking the materials as directed by the Department for all levels.
Dismantling steel work in built up sections in joists, angles, channels, tees, flats etc. including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking the materials as directed by the Department for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels.
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling of existing steel windows/ steel ventilators/ steel windows and steel ventilators without damaging the walls, removing to a safe place and necessary repairs to the edges of walls.
EARTHWORK IN EXCAVATION
Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00m below the existing ground level.
(a) In ordinary soil
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.
(b) Other than Guwahati city
Extra lead per km truck carriage for sand gravel beyond the initial lead of 8 km.
CEMENT CONCRETE WORKS:
PLAIN CEMENT CONCRETE WORKS
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
(a) In prop 1cement: 3 sand :6 coarse aggregate by volume
(b) In prop 1cement: 4 sand :8 coarse aggregate by volume
(c) In prop 1cement: 5 sand :10 coarse aggregate by volume
Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
b) 50mm thick
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
(I) Using Mixer Machine
(A) In substructure up to plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
N) Without using admixture, plasticiser
a) M15 grade concrete or Prop. 1:2:4
b) M20 grade concrete or Prop. 1:1.5:3
b) M25 grade concrete
(B) In super structure from plinth level up to 1st floor level.
ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.
N) Without using admixture, plasticiser
b) M20 grade concrete or Prop. 1:1.5:3
iii) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre and projected band.
b) M20 grade concrete or Prop. 1:1.5:3
SHUTTERING & FORM WORK
TIMBER SHUTTERING ( FORM WORK)
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
(b) Using 25mm thick plank
Sides of tie beams, grade beams etc. at or below ground level.
(b) Using 25mm thick plank
Columns, Pillars, Posts & Strut
(a) Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face
(ii) Using 25mm thick plank
Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
(ii) Using 25mm thick plank
Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a) Floors etc. upto 200mm in thickness.
(ii) Using 25mm thick plank
Vertical surface such as walls (any thickness), parapet walls, partitions, walls of septic tank, inspection pit and the like including attached pilasters, butresses, plinth and string courses and the like.
(ii) Using 25mm thick plank
Vertical ties, fins, sun breaker, louvers, bands, dropwalls etc.
(ii) Using 25mm thick plank
Providing form work of ordinary timber planking and removal of the same in edges of slabs and breaks in floors and walls etc. of in-situ reinforced concrete works upto first floor level.
(a) Thickness not exceeding 200mm.
Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.1.3(a).
BRICK WORKS ( CONVENTIONAL / FLY ASH )
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(a).Brick on flat soling.
(c).Stone soling of thickness 150mm.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4.
(II) In superstructure above plinth level up to 1st floor level.
(b) In proportion 1:4.(1 cement:4 sand)
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately)
(A) 112mm thick brick wall
(a) In cement mortar in proportion 1:4.
Providing and laying 50mm thick C.C. floor with metallic concrete hardener topping under layer of 35 mm thick cement concrete in prop.1:2:4 (1cement : 2 coarse sand : 4 coarse aggregate of 20 mm and down) and top layer of 15mm thick of metallic cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 stone aggregate 6 mm and down) by volume with which metallic hardening compound of approved quality is mixed in the ratio of 4:1 (4 parts of cement : 1 part of metallic floor hardening compound of approved quality by weight) including finishing with curing complete as directed.
TILES WORKS
CERAMIC TILES
B) ON WALLS
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
a) Normal range Somany/ Orient/Nitco/Asian Make
i) Of size 200mmx200mm and above
ANTISKID TILES
Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed.
(A) CERAMIC
i)Normal range (Sizes 300 mm x 300mm and above)
(a)Orient made: Galaxy Brown, Galaxy creama, Galaxy Pink, Galaxy Green, Pulsar Beige, Pulsar Blue, Pulsar Dove, Pulsar Pink, Burj Brown, Burj Green, Burj Slate.
CEMENT PLASTERING
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed
a) In cement mortar 1:3
b) In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
a) In cement mortar 1:3
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for providing and mixing water proofing materials in cement mortar in prop as recommended by the manufacturer including curing complete as directed.
i) 10 mm thick plaster
b) In cement mortar 1:4
ii) 15 mm thick plaster
b) In cement mortar 1:4
Extra over item no 6.2.1 to 6.2.3 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
15 mm thick plain cement mortar bands in cement mortar 1:4 in width including curing complete as directed.
A) Up to 300 mm width
a) Flush band
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
(iii) 0.50 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
(iii) 0.50 mm thick
ROOF TREATMENT
Grading roof for water proofing treatment with
(a) Cement concrete 1:2:4 (cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
I . Plain grill
(c) Fixed to Brickwork/P.C.C/R.C.C.
ALUMINIUM WINDOW AND VENTILATOR
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels.
(a) 2 Track sliding window
(ii) 5mm frosted glass
P.V.C. DOORS & DOOR FRAMES
Providing, fitting and fixing 40mm x 48mm wood reinforced PVC chowkhats fixed to the columns / stiffeners / walls with necessary holdfast / sleeves etc. as specified and directed at all levels.
Providing, fitting and fixing 24mm/ 29mm thick polymer reinforced moulded PVC door shutters fixed to the chowkath with necessary hinges, screws, bolts etc. as specified and directed at all levels (Door fixtures and fittings to be measured and paid seperately)
a) 24mm thick
DISTEMPERING
f) Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
i). Extra over item no (f), (g) and (h) above for distempering every subsequent coat of distempering with dry distemper of approved brand and manufacture.
j). Extra over item no. (f) above for distempering with dry distemper on ceiling and or sloping roof.
SPECIAL WATHER PROOF COLOURING
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
(i) Thickness = 1.5 mm thick
PAINTING ON STEEL AND OTHER METAL SURFACE
Synthetic enamel paint, aluminium paint / bituminus paint on steel and other metal surfeces. i).Removing old paint from steel and other metal surface and making the surface even.
a). With hand scraping
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i).Surfaces over 100mm in width or girth.
a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
(ii).Surfaces up to 100mm in width or girth.
a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
ALUMINIUM FITTINGS
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
a) Sliding door bolts
i) 300mm x 16mm
b) Tower bolts
i) 300mm x 12mm
c) Door handles
iii) 150mm
ENTRANCE GATE
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
Providing rails for plying of rollers of gate made made from 50mm x 6mm size M.S. flat and to be fitted with 3 nos of hinged hold fasts to be embedded in concrete prop. 1:2:4 of 10mm wide and 75 mm deep over brick flat soling 250mm wide including curing etc. complete.
Providing roller to the gate including welding etc.complete
a) With 25mmx50mm (dia) roller
b) With 12.50mmx50mm (dia) roller
REINFORCEMENT
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(ii)Super Ductile (SD) TMT reinforcement bars
BEAMS AND JOISTS
Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed.
a) In beams and joists fitted independently without connecting plates.
c) In M.S. angles, channels, Tees etc.
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire lenth and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.
ANGLES/ FLATS/ BOLTS AND NUTS
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed.
a) M. S. Angles…….
b) M. S. Flats…….
c) M. S. bolts & nuts…….
Surface dressing of ground including removing vegitation and/ or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift up to 1800mm in all kinds of soil.
Jungle clearance including up-rooting of vegetation, grass, brush-wood, saplings and trees not exceeding 300 mm girth and disposal of the same outside the periphery and lift upto 1500 mm.
Precast concrete block masonry (includingquoin blocks, jamb blocks, closure etc.) with hollow cement concrete blocks of approved size conforming to I.S. 2185 - 1965 with1:6mix (1cement: 6 graded stone aggregate, 20 mm and down gauge) 1/4th having solid materials not less than 50% total volume of block including curing complete as directed.
(c) 100mm thick in super structure in cement morter (1:4)
Jungle clearence including uprooting of vegitation, grass, brush-wood, sapling and trees not exceeding 300mm girth and disposal of the same outside the periphery and lift upto 1500mm
Providing and fixing galvd. / M.S. tube (light grade) outlet (spout) in cement mortar 1:3 including cutting and making good the wall
(a).25mm bore - 300mm long.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed.
b) 75mm thick slab
PRE CONSTRUCTION ANTI - TERMITE TREATMENT
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick layers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
PVC PIPES,BENDS,JUNCTIONS,TEES ETC.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.
a) In exposed surfaces or in trenches.
(iv) 75mm dia.
Providing 13 mm mesh hexagonal wire net made of one I.S. designation (1mm dia) wire above post plate in eaves with 1st class (Hollock/Bonsum) timber frame to fit exactly with the corrugation of roofing sheet including painting two coats with approved paint to timber works complete as directed.
turbo ventilator
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
i). 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
INDIAN TYPE WATER CLOSET
Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)
Indian type W.C Orissa pattern of size 580 x 440 mm
a) White
i) Parryware make
AUTOMATIC FLUSHING CISTERN
Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
ii) Hindware make
a) White
Auto Cister 10 litre (Cat. No.C61002)
URINAL
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.
(A) Parryware Make
(a) White
(iv) Flat Back (Cat. No.C0501/72)
WASH BASIN
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)
PEDESTAL BASIN (with pedestal)
(A) Parryware Make
(iv) Cascade NXT 550 x 440 with long Pedestal (Cat. No.C0404/C0380)
MIRROR
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
SOAP TRAY,SOAP DISH,LIQUID SOAP DISPENSER AND LIQUID SOAP CONTAINER
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified.
(a) Parryware Make
(ii) Wall Soap tray (Cat. No.C9951)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified.
(b) Sona make
(i) Towel ring round (Cat.No.TR-06051)
WASTE COUPLING
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified.
(b) Sona
(i) Rupa 32mm (HT/ FT) (Cat.No.WS-0801)
BOTTLE TRAP
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified.
(b) Sona make
(i) Bottle trap indian 32mm (Cat. No.BT-0751)
Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified.
(a) Sona make
(i) Pipe for bottle trap 300mm long (Cat. No.BT-0761)
PVC PIPES,BENDS,JUNCTIONS,TEES ETC.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 110mm dia.
(iv) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(iv) 75 mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(ii) 75 mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(ii) 110mm dia.
(iv) 75 mm dia.
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 110mm x110mm
(ii) 75 mm x 75mm
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 110mm x110mm
(ii) 75 mm x 75mm
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 110mm dia.
(iii) 75 mm dia
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 110 mm dia
(iii) 75 mm dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified.
COWEL
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
(iii) 90mm dia. PVC cowel of ISI make
GRATING
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified.
(a) 110mm dia
SOAK PIT AND INSPECTION CHAMBER
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
PIPING
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages.
(A) Exposed or in trenches
SFMC/ FUSION brand or other brand of equivalent quality.
a) PN-16 Pipe,16mm OD,SDR-7.4
b) PN-16 Pipe,20 mm OD,SDR-7.4
c) PN-16 Pipe,25 mm OD,SDR-7.4
f) PN-16 Pipe,32 mm OD,SDR-7.4
e) PN-16 Pipe,40 mm OD,SDR-7.4
f) PN-16 Pipe,50 mm OD,SDR-7.4
(B) Concealed pipe with cutting chases & making good the walls
SFMC/ FUSION brand or other brand of equivalent quality.
a) PN-16 Pipe,16mm OD,SDR-7.4
b) PN-16 Pipe,20 mm OD,SDR-7.4
c) PN-16 Pipe,25 mm OD,SDR-7.4
f) PN-16 Pipe,50 mm OD,SDR-7.4
e) PN-16 Pipe,40 mm OD,SDR-7.4
f) PN-16 Pipe,50 mm OD,SDR-7.4
BIB COCK
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately)
Essco make (Delux/Sumthing spl./Tropical)
(a) Bib cock short body
STOP COCK
Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately)
I) Brass stop cock (heavy) of Sant make
(i)15mm dia
(ii)20mm dia
(iii) 25mm dia
(iv)32mm dia
(v) 40mm dia
(v) 50mm dia
PUSH BIB COCK
Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately).
a) C.P.C.H.
(a) Light type
PILLAR COCK
Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed.
SONA make
(a) Light type
VALVE
Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.
a) 50mm dia
b) 40 mm dia.
c) 25 mm dia.
d) 2O mm dia.
e) 15 mm dia.
Supplying and fitting ball valve as specified and directed..
a) 25 mm dia. (gun metal)
b) 20mm dia. (gun metal/Copper)
Supplying fitting and fixing gun metal check valve including necessary threads to pipes.
a) 50 mm dia (Heavy type)
b) 40 mm dia (Heavy type)
Supplying fitting and fixing G.I. Foot valve with strainer including cutting necessary threads to pipes.
a) 50 mm dia (Heavy type)
b) 40 mm dia (Heavy type)
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
500 litre capacity
(a) Sintex make
Motor Pump Set
Supplying including installation, connection as approved by the Deptt., testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt
1 HP single Phase jet pump set (Horizontal(Crompton Greaves/ Aquatic/ CRI/ V-Guard make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Granular Sub-base with Well Graded Material ( Table 400.1 ) ( Only for PMGSY work )
( Construction of granular sub base by providing well graded material, spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification cl. 401
(ii) For Grading II Material
3) WBM Grading-3
Using stone screening Type-A 13.2 mm for Gr. 3
Providing laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 KN in stages to proper grade and camber, applying and brooming, stone screening to fill up the interstices of coarse aggregate, watering and compacting to the required density grading 3 as per Technical specification clause 405
A) By manual Means
Inter locking concrete block pavement
Providing and laying interlocking Concrete Block Pavement having thickness 80mm as per drawing and Technical specification clause 1504
EMBANKMENT CONSTRUCTION WITH MATERIAL
Obtained from Borrow Pits (Construction of embankment with approved material obtained from borrow pits with a lifts Upto 1.5m, transporting to site, spreading, grading to required slope and compacting to meet requirment of table 300.1 and 300.2 with a lead upto 1000 m as per technical specification clause 301.5
From private land
Extra lead beyond initial lead of 3.0 Km upto 12.0 Km. ( RS.7.74 Per CM/KM)
ELECTRICL WORKS
Wiring in surface/ recessed ISI marked Steel conduit pipe FR.(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) cable
Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia rigid ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) including 6 amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete
Medium point up to 6.00 metre. Length.
long point up to 10.0 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked Steel conduit pipe (AKG or equivalent as approved by the Deptt.) wiring system including 5 pin 6 Amps flush type plug socket and 6 Amps F/T switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. marked) with phenolic laminated sheet cover including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete, when placed elsewhere.
Short point up to 3.00 metre. length.
Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed ISI marked Steel conduit pipe wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. rigid Steel conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts(Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including earth continuity in surface/ recessed ISI marked Steel conduit pipe wiring system .
With 3 x 4 sq. mm. + earth continuity with 2x 2.5 sq. mm. cable in 25 mm. dia. rigid Steel conduit.
FITING AND ACCESSORIES
Supplying and fixing of Jaquar or equivalent philips/ Wipro LED strip Batten light fittings complete with shade, back plate including connection cable, as approved by the Deptt. as required.
LED Strip Batten, 22W
Supplying and fixing of 3 plate Ceiling Rose (Anchor Penta PC CHERRY /Gold medal /Kolor kany.kom/Havells or equivalent make as approved by the Deptt.) on the existing block including connection as approved by the Deptt.)complete as required
MCB DB (ABB, SCHNEIDER MG, LEGRAND, HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDOASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.)
MCB IN-comer SPN DB
Supplying with fitting and fixing sheet steel, phosphatised, powder painted Single door surface mounting MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
ABB, Schneider MG, legrand, Hager make)
6 way TPN (4+18) single door
MCB, MCCB, RCCB, RCBO (ABB, SCHNEIDER MG, LEGRAND, AND HAGER MAKE) & (SCHNEIDER NEO BREAK, C&S, Havells, INDO ASIAN, HPL OR EQUIVALENT MAKE AS PPROVED BY THE DEPTT.) MCB (Conform to IS / IEC 60898-1:200/ MCCB (Conform to IS/IEC 60947- RCCB (Conform to IS/IEC 12640 / 61008)
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager make)
Supplying with fitting and fixing TP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
B Series (Schneider MG, legrand, Hager Crabtree xpro make)
Supply, installation & testing of G.I. earth station with perforated 50 mm dia and 3.00 Metre long heady duty G.I. pipe with necessary 50 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 65 mmx50 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt (5 K and Charcoal (64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supplying & laying of 8 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Repairing brick wall with cement concrete ( 1:2:4 ) of thickness varing from 25mm to 100 mm after cleaning of the surface of the brick wall applying bonding agent Nitobond EP Std./Sikadur-32 LP or equivalent product to cover up the damaged portion of existing brick wall including fixing of chicken wire netin position to hold the c.concrete if necessary. Finished and complete as per direction of Engineer in Charge.
DOORS
Providing, fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 100mm x 45mm x 2.5mm section of approved brand with door style of size 88mm x 45mm x 2.5mm, top rails 50mm x 45mm x 2mm lock rails 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels.
(v) 6 mm clear glass
GYPBOARD CEILING
Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners.
Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with 25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary).
12mm thick
STONE MASONARY WORK
Stone masonary work in retaining wall, wing wall, abutment, foundation, steps, plinth etc. in cement mortar in prop 1:6 with levelling course of 1:6:12 with both faces hammer dressed including bonding, providing face stone, through stone and centering including racking of joints, curing and supplying and all carriage of stone as directed including payment of forest royalty and sales tax and carriage.
(a) Random Rubble Masonry
Refused materials like Roofing Sheet, M.S. Rebar,M.S. tube, M.S. angle,various debrishes etc collected during renovation of the existing structures recovered by the contractor at his own risk including transfer of the materials from the site before completion of the work. The work should be done under supervision of Engineer incharge and PM Consultant.
MS UDAY ENTERPRISE
PABITRA SAIKIA
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .