Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.1 L+₹38,076.82 (4.90%)Rejected-Finance KANKARDANGA | L2 | Rejected-Finance stood L2 | |
| 3 | L3₹8.9 L+₹1.2 L (15.1%)Rejected-Finance GR 8 ADDA BUILDING 1ST FLOOR CITY CENTRE DURGAPUR 16 | DURGAPUR | PASCHIM BARDHAMAN | WEST BENGAL | L3 | Rejected-Finance stood L3 |
Tender Value
Refer Docs
EMD Value
₹19,500
Closing Date
13 Dec 2024, 6:00 pmClosed
EE.AED.PWD
Office of the Executive Engineer (P.W.D.) Asansol Electrical Division Near Polo Ground Dist Paschim Bardhaman PIN-13304
Electrical Installation work in Medicine Store in ground floor of Asansol District Hospital , Paschim Bardhaman.
2024_WBPWD_778142_1
WBPWD/EE/AED /eNIQ-79(2nd Call)/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
ASANSOL
Please refer Tender documents.
4 documents required · 4 mandatory
₹19,500
Office of the Executive Engineer P.W.D. Alsanso
28 Aug 2025
3 Dec 2024
16 Dec 2024
3 Dec 2024
13 Dec 2024
7 Dec 2024
6 Dec 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire(Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box,making earthing attachment, painting the MS box and mending good the damages to original finish Average run 8 mtr.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm,25mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required a) 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC .
b) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC .
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. A) 6 sq mm
b) 4 sq mm
c) 2.5 sqmm
Supplying and fixing 415V,16-32A per way , double door Horizontal TPN MCB Distribution board (Enclosure (607716)with IP-42/43 protection,with 63A, 4 pole isolator as incomer and SPMCB's ('C' curve,10kA) as outgoing concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (Legrand/ABB/Siemens) a) 4 way,,63A FP isolator,12nos. SPMCBs as outgoing.
Supplying and fixing double-door SPN MCB Distribution Board(Enclosure-607711) with IP-42/43 protection, with DP isolators as incomer and SPMCB('C' Curve,10A) as outgoing,fixing at flat iron frame on wall &mending good the damages to original finish; inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.(Make: Legrand/ABB) i) (2+8)Way,with S&F 240V 40Amps DPMCB isolator as incomer and 240V 6-32A SPMCB of Breaking capacity 10KA & C characteristics 8 nos as outgoing, 2+8 Way (Legrand/ABB/Siemens)
Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. supply of 16 A DP MCB ,painting, connection & provision for earthing attachment .
Supply & delivery of XLPE/A Al cable of following size with 2 nos 10 SWG GI wire as ECC.(Make- Havells/Polycab/KEI/Gloster) as per choice of EIC. 4Core 35 Sqmm. (From panel to TPNDB)
Supplying and fixing 415V, 100ATPN SFU with sheet steel enclosure on flat iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :4 core 35 sqmm
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials. 4 core 35 sqmm.
Supply & Fixing of perforated GI cable tray with perforation not more than 17.5% suspended from ceiling incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.With out angle iron support. 150x50x1.25mm (18SWG).
Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceiling with two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.150x50x1.25mm (18SWG).
S/Delivery following 250 Volt, 18/20 Watt, 4 Ft. long single/double LED Tube fittings complete with LED polycarbonate tube lamp having at least 100 lumen/watt and cast iron box type fittings.(Make- Crompton/Philips Master LED)a. Single LED Tube(18/20 Watt)
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “U” type MS clamp whose both side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
S/F BC LED lamp (B22) as per direction of E.I.C. (Make- Philips/Crompton/Syska)(9watt)
Supplying and delivery of 250 volts, 50Hz, (12”) sweep 1420 R.P.M. heavy duty exhaust fan complete with all accessories (Make-EPC/usha.CG) as per direction of EIC. Exhaust fan(12”)
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12")
Supply & Fixing 30 cm Exhaust fan (12") louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long)
Supply of 48"ceiling fans complete with all accessories like fan blade,canopy,capacitor etc Model / Cat No. ( Make - USHA /Crompton Greaves/Havells ) as per direction of EIC a.1200 mmSweep .
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWDSpecification Book – May 1991)
Supplying & fixing of 415V, Timer DB Fixed on Wall by flat iron/Angle frame or as per direction of EIC . The Box should comprising following accessories......... A).Double-door SPN-MCB Distribution Board with IP-42/43 protection 2+12 way make Legrand/L&T or as to GS. B). 1No. 250V ,50Hz,16 Amp Digital daily & weekly time switches(Make L&T-67DDT0/Eqv. legrand) C)1No 415V,40A FP-Contractor(Make-L&T/Eqv. legrand). D)1No. 415V,40A FP-MCB(Make-L&T/Eqv. legrand). E)1 No. Toggle Switch(Pass & Seymour) should be fixed inside the box. F)1Nos LED Indication Lamp for running condition. G)The complete arrangement must be wiring by suitable size of PVC insulated Cu wire with suitable socket/lugs as per requirement & direction by EIC.
Supply & Delivery of 3-Star rated Non-Inverter Hybrid Hi-Wall split type room air conditioner with following accessories & features : i). Tonnage : 2.2 Ton. ii). Refrigerant Type : R410/R32A. iii). Compressor type : Super Tropical return cooled Rotary type. iv). Evaporator & Condenser Meterial : Copper. v). Power Supply : 230V,50Hz,1Φ. vi). Running Current at F.L : 9.2Amp. vii). Standard cooling at 100% capacity : >7500W (Max) viii). Power Consumption at 100% capacity : 2050W (Max) ix). Rated ISEER (Kwh/Kwh) : 3.72 or higher. x). Inndoor Fan Speed Control level : 4/5 Speed Control. xi). Indoor Air-Flow Volume High : 1450CMH. xii). Indoor Airflow Distace : 15-18m. xiii). Indoor Noise level : < 40db. xiv). Remote : Wireless Advanced Remote operation. (Make: Mitsubishi Heavy SRK25CSS-S6A/O-General/Hitachi).
Supply & Delivery of 3-Star rated Non-Inverter Hybrid Hi-Wall split type room air conditioner with following accessories & features : i). Tonnage : 1.5/1.6 Ton. ii). Refrigerant Type : R410/R32A. iii). Compressor type : Super Tropical return cooled Rotary type. iv). Evaporator & Condenser Meterial : Copper. v). Power Supply : 230V,50Hz,1Φ. vi). Running Current at F.L : 6.6Amp. vii). Standard cooling at 100% capacity : >5900W (Max) viii). Power Consumption at 100% capacity : 1485W (Max) ix). Rated ISEER (Kwh/Kwh) : 3.99 or higher. x). Inndoor Fan Speed Control level : 4/5 Speed Control. xi). Indoor Air-Flow Volume High : 1350CMH. xii). Indoor Airflow Distace : 15-17m. xiii). Indoor Noise level : < 40db. xiv). Remote : Wireless Advanced Remote operation. (Make: Mitsubishi Heavy SRK20CSS-S6A/O-General/Hitachi).
Lifting,Shifting,Installation,Testing & Commissioning of IDU & ODU of Split Air Conditioners machines,after making hole in wall on mending good the damages to the original finish as required & necy. scaffolding arrangement, labour cost etc.on both side(IDU & ODU Installation),Supply of required Refrigerant R32/R-410A & Supply & Fixing of Heavy Duty ODU stand by drilling holes in wall,fastners ,bolts washers as per direction of EIC.
Supply & Fixing of Copper Refrigeration pipe line for liquid and suction line with fittings, elbows, bends, supports & brackets etc. with 9mm nitrile rubber tube with proper insulation tape required. (Make- Ryoku/Totaline/Jobu/ Nippon/EIC Approved). i) Suction Line (5/8" OD with 0.7mm thick)
ii). Liquid Line (1/4" OD with 0.6 mm thick)
Supply and laying Control copper Cable (PVC insulated & unshethed,un-armoured) from Condensing Unit to IDU control panel & Vice Versa if Required as per OEM (Make: Havells/RR Kable /finolex/EIC Approved ) i). 4 core 2.5 sq mm cable.[IDU to ODU]
Supply and laying of 25mm Drain Water piping work out of PVC/HDPE hard pipes of following sizes incl. fiting accessories bends, elbows, tees flanges, tapings, wall sleeves hangers, supports, anchors etc. as required. (Make : Supreme / Astral/ EIC approved).
Supply & Fixing 240 V, 20 A Plug socket (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.(For AC)
Supply and delivery of 20A Plug Top for interconnection of Indoor AC machine Brand as per choice of EIC.
S/F of 22 A OLP 3 plus starter(Electron make on suitable size MS box with 3mm top cover incl. fixing of MS box & mending good the damages to original finish.
Supply and fixing of 12 V battery charger 125 KVA DG near pathology.
Add GST @18% On total from item no 1 to 32.
Add LWC @1% On total from item no 1 to 33.
SASTIK ENTERPRISE (BID ID -5846960)
DURGAPUR POWER (BID ID -5842464)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .