Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹15.6 L+₹44,260 (2.92%)Rejected-Finance | L2 | Rejected-Finance Not the lowest tenderer | |
| 3 | L3₹18.4 L+₹3.3 L (21.5%)Rejected-Finance | L3 | Rejected-Finance Not the lowest tenderer | |
| 4 | L4₹18.5 L+₹3.4 L (22.2%)Rejected-Finance | L4 | Rejected-Finance Not the lowest tenderer | |
| 5 | L5₹18.9 L+₹3.7 L (24.5%)Rejected-Finance | L5 | Rejected-Finance Not the lowest tenderer |
Tender Value
₹22.7 L
EMD Value
₹45,400
Closing Date
1 Sept 2020, 6:00 pmClosed
Garrison Engineer South Delhi Cantt 110010
Delhi Cantt 110010
REPAIR AND MAINTENANCE OF LEAKAGE SEEPAGE INCL REPAIR OF ROOF IN YOGENDER VIHAR AND 1 CBPO UNDER AGE B/R-I (S) OF GE (SOUTH) DELHI CANTT-10
2020_MES_366439_1
GE/DS-23/2020-21
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer South Delhi Cantt 110010
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer South Delhi Cantt 110010
₹45,400
Yes
22 Oct 2020
4 Aug 2020
3 Sept 2020
4 Aug 2020
1 Sept 2020
18 Aug 2020
5 Aug 2020 - 15 Aug 2020
Amount
Demolition mud in roofs any thickness including plastering and leaping and including necessary scaffolding arrangement upto four storey building and removing from cantonment area complete all as specified and directed by Engineer-in-charge
Dismantling Brick tiles or terracing tiles single layer on roofs and removal from site complete all as specified and directed by Engineer-in-charge.
M&L for screed bedding 15 mm thick plaster in CM 1:4 on roof finished even and fair using extra cement on roof with water proofing compound up to four stories bldgs WPC shall be measured and paid seperately complete all as specified and directed by Engineer-in-charge.
S&F APP based polymeric water proofing membrane minimum weighing 3 Kg/sqm and 3mm thick reinforced with polyster non woven fabric ( weight not less than 150 gms/sqm) of make "multiplas" manufactured by STP Texsa LTd or Hyper plas polymer water proofing membrance manufactured by M/s IWL India Ltd or 'Shalli plas' (polyester) manufactured by M/s Capital Steels and Chemicals Pvt Ltd or "Make Poly Plast" manufactured by M/s M K Petro, STP superior polyplas manufactured by STP Ltd as approved by GE laid over and including applying evenly a tack coat of industrial bitumen 85/25 @ 1.2 kg per sqm by torch application including cleaning of surface complete all as per approved manufacturer,s instructions Note The water proofing treatment shall be got carried out by manufacturer or their auth applicators complete all as specified and directed by Engineer-in-charge.
M&L for PCC 1:2:4 type B-1 using 20 mm graded aggregate as in roof padding for providing rqd slop finishing surface even and smooth with out using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for cement concrete tiles 25cmx25cmx22mm thick laid over and including 20mm thick screed in cement mortar 1:6 and jointed grouted and pointed in CM 1:3 complete all as specified and directed by Engineer-in-charge.
Supply only water proofing compound ISI Marked (Siko or equivalent) complete all as specified and directed by Engineer-in-charge.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engineer-in-charge.
M&L for 40mm thick flooring in PCC 1:2:4 type B-1 using 20 mm graded aggregate as in floors finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
S&F 15mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as specified and directed by Engineer-in-charge.
S&F 20 mm bore galvanised iron pipe medium grade with all fittings fixed to wall and ceiling or laid in floor including taking down of old GI pipes and connections complete all as specified and directed by Engineer-in-charge.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 15 mm dia including taking down of old GI pipes and connections complete all as specified and directed by Engineer-in-charge.
Refixing of old steel tubing and connection in new or old position (Wall/Ceiling etc) incl cleaning for refixing, bore of pipe 20 mm dia including taking down of old GI pipes and connections complete all as specified and directed by Engineer-in-charge.
Taking down cement plaster including racking out joints hacking for key scrubbing down with water etc on walls and ceiling complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 on wall surfaces and finished surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for rendering 15mm thick on other than fair faces of brick work or concrete surfaces in cement mortar 1:4 on wall surfaces and finished surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-charge.
M&L for 10 mm thick rendering in CM (1:3) on ceiling finished even & Fair Without using extra cement complete all as specified. complete all as specified and directed by Engineer-in-charge.
M& L for of new plastered surface and applying two coats of distemper oil emulsion over water based primer with chalk whiting on wall surfaces complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plaster surfaces and applying three coats of white wash on ceilling complete all as specified and directed by Engineer-in-charge.
M&L for applying two coats of cement base paint, white or tinted on new plastered surfaces including preparation of surfaces complete all as specified and directed by Engineer-in-charge.
M&L for preparation of new plastered wall surfaces and applying three coats of white wash on plastered surfaces of walls complete all as specified and directed by Engineer-in-charge.
M&L for preparing old plastered surfaces and applying a coat of white wash on wall complete all as specified and directed by Engineer-in-charge.
M&L for prepapring old plastered surfaces and applying a coat of white wash on ceiling complete all as specified and directed by Engineer-in-charge.
Dismantling water tanks exc.500 lit & nexc.1000 lit complete all as specified and directed by Engineer-in-charge.
S&F 500 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) while triple layered hoisted and fixed in position complete all as specified and directed by Engineer-in-charge. Make:- Polywell/Sintex/Rotex.
M&L for 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high-density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms/ 20mm-210 gms/25mm-455gms/ 40mm- 690 gms) complete all as specified and directed by Engineer-in-charge.
S&F in repair 15mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair 20mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both end for iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including suitable clamps complete all as specified and directed by Engineer-in-charge.
S&F in repair PVC (SWR) bends any radius 110mm dia fixed to PVC pipes complete all as specified and directed by Engineer-in-charge.
Cutting of trees including cutting of trunk n.exc 15cm girth and branches and digging out roots from floor or roofs and walls of up to four storied bldg and making good the dismantled portion in cement mortar 1:3 to match the existing surfaces any numbers in area up to 1.5 sqm each complete all as spd. Note :- Any nos of trees/shrubs in area up to 1.5 sqm shall be considered as one unit
M&L for Cement concrete Type F2 (1:7:12) using 40 mm graded stone aggregate in mass concrete complete all as specified and directed by Engineer-in-charge.
S&F in repair vitreous china squatting pan (Orissa pattern) long pan fixed size 580x440mm white with integral footrest with `P' or `S' trap complete (excluding flushing cistern and flush pipe) complete all as specified and directed by Engineer-in-charge.
S&F in repairs 10 ltrs capacity PVC Low level flushing cistern including PVC syphon and float valve with float, PVC long bend for out let connection of cistern with WC complete fixing and connecting bend with WC complete all as specified and directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement moratr bedding (but not backing), removing serviceable tiles to store and rubnbish off the premises complete all as specified and directed by Engineer-in-charge.
M&L for 25mm thick cement concrete type B-0 1:2:4 (12.5mm graded aggregate) as in sub floors finished rough complete all as specified and directed by Engineer-in-charge.
M&L non skid coloured ceramic tiles joint less 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc set & jointed in neat cement slurry & pointed in coloured cement to match over and including 15mm thick screed bed in CM1:6 for laying floor finish complete complete all as specified and directed by Engineer-in-charge.
M&L for coloured glazed ceramic tiles300 x 200 x 7 to 8 mm thick as an vertical surfaces over 10mm thick rendering with CM 1:4 and jointed & neat cement slurry and pointed in white cement mixed with pigment to match the existing surface complete all as specified and directed by Engineer-in-charge.
S&F in repair 15 mm bore brass CP fancy type bib cock long body screwed down to iron pipe,complete all as specified.(Make-Zim/Parko/Prayag) complete all as specified and directed by Engineer-in-charge.
S&F in repair pillar taps, cast copper alloy, with capstan heads, chromium plated,fancy type, screwed down high pressure, with or without lettered (Hot or cold) with long screwed for 15 mm dia iron pipe and fixed complete all as specified and directed by Engineer-in-charge.
S&F in repair PVC connection 15mm x 450 mm including nuts & washers complete all as specified and directed by Engineer-in-charge. Make:- (Prayag)
S&F in repair 15 mm angle valve / stop cock chromium plated, cast copper alloy screwed down high pressure with crutch or butterfly handle screwed for both ends for ironor for unions complete all as specified and directed by Engineer-in-charge.
S&F in repair wash hand basins of size 550 x 400mm including 32 mm dia PVC waste pipe and PTMT waste coupling complete all as specified and directed by Engineer-in-charge. Make 'Parryware/Cera/Hindware.
Dismantling Cast iron pipe 100 dia incl all fittings of any description and in any position complete all as specified and directed by Engineer-in-charge.
Dismantling Cast iron pipe 75mm dia incl all fittings of any description and in any position complete all as specified and directed by Engineer-in-charge.
S&F 100 mm dia sand cast iron soil waste and vent pipe in any length with or with out ear with cement joint fixed to walls complete all as specified and directed by Engineer-in-charge.
S&F 75 mm dia sand cast iron soil waste and vent pipe in any length with or with out ear with cement joint fixed to walls complete all as specified and directed by Engineer-in-charge.
Refixing of 100mm dia sand cast iron soil waste & vent pipe in any position complete all as specified and directed by Engineer-in-charge.
Refixing of 75mm dia sand cast iron soil waste & vent pipe in any position complete all as specified and directed by Engineer-in-charge.
S&F in repair 100mm dia CI 'P' or 'S' trap complete all as specified and directed by Engineer-in-charge.
S&F in repair 75mm dia CI 'P' or 'S' trap complete all as specified and directed by Engineer-in-charge.
S&F in repair 75mm dia CI Bends or diminishing pieces or tapers complete all as specified and directed by Engineer-in-charge.
All same as per ser item No. 52 above but for 75mm dia with oval access door.
S&F in repair Branch pieces,Tee junction with bore of pipe 100 mm, single (equal or unequal), ordinary or inverted, spigot or socket type or with parallel branches with Ovel Access door complete all as specified and directed by Engineer-in-charge.
S&F in repair Branch pieces, Tee junction with bore of pipe 75 mm, single (equal or unequal), ordinary or inverted, spigot or socket type or with parallel branches with ovel Access door complete all as specified and directed by Engineer-in-charge.
M&L in repair 75 mm outlet dia CI floor trap with grating incl jointing to waste pipe in run lead complete all as specified and directed by Engineer-in-charge.
Extra over CI pipes and fittings if lead jointing is provided in lieu of cement joint 100mm bore complete all as specified and directed by Engineer-in-charge.
Dismantling / removal of APP membrane from roof and cleaning the surface including removal of dismantled material from site complete all as specified and directed by Engineer-in-charge
Attending complaint for repair to floor, ceiling plaster, internal wall plaster, external wall plaster, repair of chhajja, repair of drain brick masonary or any type of mason complaint, broken tiling, patch of tiling work, complete including repair minimum defective places if required, complete all as specified and directed by Engineer-in-charge. Notes 1:- The contractor shall make all arrangement for attending the different types of complaints of Yogender vihar OR,s married accn and 1 CBPO area on day to day basis. Any major item required to be replaced with new one, to make the system functional shall be measured and paid for separately as "M&L " under respective item of this schedule. Old retrieved item(s) as considered in 'Schedule of Credit' shall become property of the contractor. 2 :- Contractor shall provide minimum one mason with one helper including all necessary T&P on all working days from 9AM to 5PM . Additional workers can be engaged if nature of work required to be completed within fix time frame as desired by the GE. Rate shall be quoted accordingly, keeping in mind above said provisions. 3 :- Where material provided shall be paid as "M&L " under respective item of Sch 'A', the payment of complaint under this item shall not be paid. 4. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.
Attending complaint for petty repair to leaking water in bib tap, pillar tap, stop cock, angle valve, flushing cistern, WHB, Sink, wall mixer etc of any description any size by changing the washers (s)/jumper (s) etc, by adjusting/replacing the washer(s) and adjustment of lever required for making the flushing cistern functional, by tighting the leaking waste pipe of WHB/Sink and providing 'M' seal to stop leakage as required. Removal of air lock/blockage of water in GI water tubing and cleaning the pipe or fitting etc including replacement of major defective item if required, complete all as directed by Engineer-in-Charge. Notes 1:- The contractor shall make all arrangement for attending the different types of complaints of Yogender vihar OR Md accn and 1 CBPO area on day to day basis. Any major item required to be replaced with new one, to make the system functional shall be measured and paid for separately as "M&L" under respective item of this schedule. Old retrieved item(s) as considered in 'Schedule of Credit' shall become property of the contractor. 2 :- Contractor shall provide minimum one plumber with one helper including all necessary T&P on all working days from 9AM to 5PM. Additional workers can be engaged if nature of work required to be completed within fix time frame as desired by the GE. Rate shall be quoted accordingly, keeping in mind above said provisions. 3. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR/Bill.
Note:- The contract sum shall be after deducting the amount of Credit shown in Credit Schedule of this Tender.
SABHARWAL CONSTRUCTION CO.
R C Sharma and Co
M/S Davinder Kumar
POONAM ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .