| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹71.0 LAccepted-AOC 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | L1 | Accepted-AOC L1 | |
| 2 | L2₹82.5 L+₹11.5 L (16.1%)Rejected-Finance 116 SHANTINAGAR ROAD BHADRAKALI UTTARPARA HOOGHLY WEST BENGAL 712232 | HOOGHLY | WEST BENGAL | 712232 | L2 | Rejected-Finance Higher Quoted Rate. | |
| 3 | L3₹85 L+₹14.0 L (19.7%)Rejected-Finance 9TH FLOOR ABHIJEET MITHAKALI SIX ROADS MITHAKALI AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | L3 | Rejected-Finance Higher Quoted Rate. | |
| 4 | L4₹86.5 L+₹15.5 L (21.9%)Rejected-Finance | L4 | Rejected-Finance Highest Quoted Rate. |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
25 Sept 2019, 12:00 pmClosed
SE, Kolkata Electrical Circle, PWD
P-16, India Exchange Place Extn. KIT Building, 2nd Floor, Kolkata-700073
Renovation of Electrical Installation, HVAC, Fire Detection and Ventilation system at 1st floor to 4th floor at Uttirna-HVAC Works.
2019_PWDE_242545_1
PWD/SE/KEC/NIT-04/19-20
Open Tender
A/C ORG
Item Rate
60 days
Kolkata
Please refer Tender documents.
8 documents required · 8 mandatory
₹1.7 L
Office of the SE, Kolkata Electrical Circle, PWD
21 Sept 2021
5 Sept 2019
27 Sept 2019
5 Sept 2019
25 Sept 2019
17 Sept 2019
16 Sept 2019
Amount
HVAC Works Variable Refrigerant Flow System: Supply, erection, testing & commissioning of Modular Type outdoor units considering All Inverter Technology based Variable Frequency Driven VRF air-conditioners with air-cooled outdoor units, which shall be capable of cooling as per individual or season requirement suitable for operation on 415V, 3 phase, 50 Hz AC electric supply. Supply of the All Inverter Technology with scroll compressor VRF Outdoor units. The unit should be suitable for non-ozone depleting refrigerant R410A/R-32 refrigerant including charging of the refrigerant of capacity mentioned below- ODU TOP DISCHARGE - 24 HP COP at 50% Load and 40°C DBT outdoor temperature should be 4.5 or above. There should be no capacity deration upto 40°C (Make-Blue Star / Carrier / Daikin / Hitachi / Voltas / Trane / Mitsubishi Electric / General).
Supply, erection, testing & commissioning of INDOOR UNITS considering inverter Technology based VFD VRF air conditioners with air cooled indoor unit which shall be capable of cooling as per individual or season requirement including cordless remote control (make same as ODU). (a) Indoor Unit 4 way cassette 2.3 TR
Do----Do----Do----Do (b) Indoor Unit 4 way cassette 3.2TR
Do----Do----Do----Do (c) Indoor Unit 4 way cassette 4TR
Supply, erection, testing & commissioning of Y Joints as per direction of EIC.
Lifting, shifting & positioning of VRF Outdoor Units with necessary supports, vibration isolation pads etc.
Supply, laying, dressing, testing & commissioning of standard copper 3C x 1.5 sq.mm shielded communication cabling including clamping and supporting as per standard specifications.
Supply, installation, testing & commissioning of drain piping consisting of hard PVC pipes of following sizes insulated with 9mm nitrile rubber insulation. (a) 25 mm
Do----Do----Do----Do (b) 32 mm
Do----Do----Do----Do (c) 40 mm
Supply, installation, testing & commissioning of the insulated refrigerant piping between outdoor unit to indoor units as per the specifications. The insulation shall be of 19 / 13mm thick Nitrile rubber throughout the running length of suction refrigerant piping (a) Dia 38.1 mm (with 19mm thick nitrile rubber insulation)
Do ---------- do ---------------- (b) Dia 31.75 mm (with 19mm thick nitrile rubber insulation)
Do ---------- do ---------------- (c) Dia 28.6 mm (with 19mm thick nitrile rubber insulation)
Do ---------- do ---------------- (d) Dia 25.4 mm (with 19mm thick nitrile rubber insulation)
Do ---------- do ---------------- (e) Dia 22.2 mm (with 19mm thick nitrile rubber insulation)
Do ---------- do ---------------- (f) Dia 19.1 mm (with 19mm thick nitrile rubber insulation)
(g) Do ---------- do ---------------- Dia 15.9 mm (with 19mm thick nitrile rubber insulation)
(h) Do ---------- do ---------------- Dia 12.7 mm (with 13mm thick nitrile rubber insulation)
(i) Do ---------- do ---------------- Dia 9.5 mm (with 13mm thick nitrile rubber insulation)
Supply & fixing of GI cable trays of size 300 mm (W) x 50 mm (D) x 2 mm (T) with vertical sides on both ends and suitable MS supports including concrete bolts, hold fast etc.
Supply & errection of MS STRUCTURAL WORK as required to make the outdoor units ready and complete for installation and functioning (Drawing and Design to be approved by EIC).
Dismantling of Existing IDU carefully for further reinstallation, as directed by EIC
Reinstallation of Existing IDU carefully at relocated position, as directed by EIC including additional charging of Refrigerant if required.
Dismantling of existing refrigerant piping of different dia including dismantling of drain line, as directed by EIC. N.B: (a) The Agency must procure the materials from the Manufacturer / OEM or from their authorized. Sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. (b) Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the e-mail of Engineer-in-Charge and hard copy of it to be submitted during execution of work / submission of bill. (c) Certification in original from the manufacturer / OEM, as the case may be, regarding originality of the material must be submitted before any payment. (d) If any refurbished material is supplied and installed, penal action will be taken as per existing rules.
AIR Q SOLUTIONS
JOHNSON CONTROLS HITACHI AIR CONDITIONING INDIA LTD.
EVAC ENGINEERING PROJECTS PVT. LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .