Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC GROUND FLOOR F 11 PHASE II MAYAPURI WEST DELHI DELHI 110064 | DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹25.9 L+₹65,875 (2.61%)Rejected-AOC | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹26.4 L+₹1.2 L (4.57%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹28.2 L+₹2.9 L (11.7%)Rejected-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹28.4 L+₹3.1 L (12.2%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
11 Jun 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
REPAIR MAINT OF CENTRIFUGAL AND MONOBLOCK PUMP SETS STARTERS AND CONNECTED WORKS IN THE AREA OF AGE U WATER SUPPLY NO III UNDER GE U WATER SUPPLY DELHI CANTT 10
2024_MES_655257_1
GE/WS/Token-05 OF 2024-25
Open Tender
Civil Works
Item Wise
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹84,000
Yes
26 Sept 2024
21 May 2024
13 Jun 2024
21 May 2024
11 Jun 2024
4 Jun 2024
Amount
Opening the electric induction motor of following capacity and taking out the burnt winding wire complete and cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing size/gauge with and including all other insulating material complete all as specified and as directed:-
10-25 HP capacity
30-40 HP capacity
50-75 HP capacity
Notes :- (a) Serviceability of induction motor after repair shall be got tested by EIC before installation and refixing at site. (b) Each motor maintenance / functionality / serviceability will be covered for one year after satisfactory repaired and if induction motor winding brunt out in the contract period or within defect liability period of one year, the same will be repaired by contractor free of cost at his own arrangement and risk. (c) Repair / Maintainance of induction motor shall be carried out from OEM authorised workshop only after getting approval of GE. (d) A BOO will be ordered for verification of serviceable & functionality of motor after repair from workshop and the same will kept on record duly concurred by GE. (e) Spare parts & copper winding shall be measured and paid seperately under respective items as supply only.
Disconnecting of electrical connections from panel board and taking out electic motor of following capacity from base plate of pump set after opening the nuts, bolts and transporting the motor to workshop and back, reinstalled after repair and testing complete all as specified and as directed :-
10-25 HP capacity
30-40 HP capacity
50-75 HP capacity
Notes :- (a) Serviceability of induction motor after repair shall be got tested by EIC before installation and refixing at site. (b) Each motor maintenance / functionality / serviceability will be covered for one year after satisfactory repaired and if electric motor winding brunt out in the contract period or within defect liability period of one year, the same will be repaired by contractor free of cost at his own arrangement and risk. (c) Repair / Maintainance of induction motor shall be carried out from OEM authorised workshop only after getting approval of GE. (d) A BOO will be ordered for verification of serviceable & functionality of motor after repair from workshop and the same will kept on record duly concurred by GE. (e) Spare parts & copper winding shall be measured and paid seperately under respective items as supply only.
Supply only of terminal box for 30-40 HP Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply only of terminal box for 50-75 HP Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply only terminal connection plate for 10-25 HP of OEM make as per site condition of standard quality complete all as specified and directed.
Supply only terminal connection plate for 30-40 HP of OEM make as per site condition of standard quality complete all as specified and directed.
Supply only terminal connection plate for 50-75 HP of OEM make as per site condition of standard quality complete all as specified and directed. (Note for ser item No 3 to 7 :- Old U/s material Terminal connection plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV Iron Scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply only of CI bearing plate for electric motor 10-25 HP of OEM make as per site condition of standard quality complete all as specified and directed.
Supply only of CI bearing plate for electric motor 30-40 HP of OEM make as per site condition of standard quality complete all as specified and directed.
Supply only of CI bearing plate for electric motor 50-75 HP of OEM make as per site condition of standard quality complete all as specified and directed. (Note for ser item No 8 to 10:- Old unserviceable material CI bearing shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
Disconnecting the electric connection of monoblock pump of capacity 10 HP and removing the same from foundation for repair after opening /cutting the rusted nuts, bolts etc and dismantling complete pump and repairing the same with replacing the following unserviceable spare parts i.e CI Impeller, GM shaft sleeve, Mechanical seal, water seal, water liquid reflector, MS stud with nut, gasket packing including grinding work of lathe machine and re-assembling the same including the transporting the pump from side to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and directed. (Note:- (i) Proper inventory for repair and over hauling parts replaced during the repair in work shop shall be prepared and kept in record dully verified and signed by EIC. (ii) Old unserviceable parts repaired & replaced shall be taken on charge under demolition/salvage register with page number in demolition statement.)
Openig the monoblock pump set of cap upto 10 HP and taking out the burnt winding wire complete and cleaning the slots rewinding the motor with super enamelled copper wire of existing gauge/size with and including insulating material. Compete all as specified and as directed. Note : "Copper winding wire of appropriate gauge will be measured under respective item as supply only"
Supply only super enamelled copper winding wire of suitable gauge with insulating material complete all as specified and directed. (Note : (i) Bidder will quote all in all rate according to weight of copper rewinding retrieved after dismentling and mode of measurement of the item is in "KG" only for all the repair/overhandling. Please quote rate accordingly, no any extra cost will be paid by Govt. (ii) A BOO conveyed for working out old unserviceable copper winding quantity details of each pump and the same replaced with new super enamel copper wire of suitable gauze as per old pumps make and submit serviceability / functionality of pumps. (iii) Transportation/freight charges for shifting of pump to workshop and recieved back in the laying/installation place as directed by Engineer-in-Charge shall be deemed included in quoted rate. (iv) Old unserviceable brunt copper winding wire shall be measured in 'KG' and shall be taken in salvage/demolition ledger and the same will be mentioned in demolition certificate with showing page number & ledger number.
Disconnecting and De-coupling the centrifugal pump of following capacity from foundation after cutting of rusted MS nuts, bolts and transported to workshop for repairing and back, re-installed in existing position complete including MS nuts, bolts and packing flange complete all as specified and as directed.
10-25 HP Capacity
30-40 HP capacity
50-75 HP capacity
Notes :- (a) Serviceability of centrifugal pump after repair shall be got tested by EIC before installation and refixing at site. (b) Each pump maintenance / functionality / serviceability will be covered for one year after satisfactory repaired and if centrifugal pump winding brunt out in the contract period or within defect liability period of one year, the same will be repaired by contractor free of cost at his own arrangement and risk. (c) Repair / Maintainance of centrifugal pump shall be carried out from OEM authorised workshop only after getting approval of GE. (d) A BOO will be ordered for verification of serviceable & functionality of motor after repair from workshop and the same will kept on record duly concurred by GE. (e) Spare parts & copper winding shall be measured and paid seperately under respective items as supply only.
Opening the centrifugal pump and repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position of following capacity:-
10 to 25 HP Capacity
30 to 40 HP Capacity
50 to 75 HP Capacity
Notes :- (a) Serviceability of centrifugal pump after repair shall be got tested by EIC before installation and refixing at site. (b) Each pump maintenance / functionality / serviceability will be covered for one year after satisfactory repaired and if centrifugal pump winding brunt out in the contract period or within defect liability period of one year, the same will be repaired by contractor free of cost at his own arrangement and risk. (c) Repair / Maintainance of centrifugal pump shall be carried out from OEM authorised workshop only after getting approval of GE. (d) A BOO will be ordered for verification of serviceable & functionality of motor after repair from workshop and the same will kept on record duly concurred by GE. (e) Spare parts & copper winding shall be measured and paid seperately under respective items as supply only.
Supply only following spare parts for centrifugal pump of capacity 10-25 HP of OEM make only:-
CI Impeller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/P/011 make unique
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
Supply only following spare parts for centrifugal pump of capacity 30-40 HP of OEM make only:-
CI Impeller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/Q/014
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
Supply only following spare parts for centrifugal pump of capacity 50-75 HP of OEM make only;-
CI Impeller
CI Casing wear ring DE/NDE
CI Gland plate
Key for impeller
Impeller nut
Remetalling of pump shaft turning and balancing
CI Stuffing box bush
Pump shaft SS (AISI-410)
Gland packing champion
CI Bearing cartiage DE/NDE
CI Tyre coupling type TC/Q/014
SS Eye bolt with nut
CI Shaft sleeve
Set Gasket packing.
MS Stud with nut
MS coupling key
Note for item No 16 to 18:- Old unserviceable spare parts shall be taken on charge under demolition ledger or scrap ledger with showing value of iron scrap in 'KG' and attach the same page of salvage register with each RAR.
M&L for painting (two coat of synthetic Enamel paint) on centrifugal pump & motor of any capacity rating 10-75 HP, scratching the rusted and suction/delivery pipe line including NRV and sluice valve, MS Base chanel complete all as specified and as directed.
S&F in replacement of MS base channel of existing size including cutting welding making hole and painting (two coat of synthetic enamel paint over a coat of red oxide primer) complete all as specified and as directed. (Note :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
S&F in replacement of MS foundation bolts with nuts and washers size 20 mm dia and 450 mm long complete all as specified and as directed. (Note :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
Supply and Fixing Ball bearing 6305 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6306 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6307 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6308 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6309 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6310 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6311 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6312 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6313 of OEM make best quality complete all as specified and directed.
Supply and Fixing Ball bearing 6314 of OEM make best quality complete all as specified and directed.
Supply and Fixing of double ball bearing 3307 of OEM make best quality complete all as specified and directed.
Supply and Fixing of double ball bearing 3309 of OEM make best quality complete all as specified and directed.
Supply and Fixing of double ball bearing 21309 of OEM make best quality complete all as specified and directed.
Supply and fixing of Rollar bearing No-313 of OEM make best quality complete all as specified and directed.
Supply and fixing of Rollar bearing No-314 of OEM make best quality complete all as specified and directed. (Note for ser item No 22 to 36 :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. Note (i) :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items. (ii) Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm dia
150 mm dia
Supply and fixing jointing and testing of cast iron Non return valve without by pass arrangment swing type confirming to IS 5312 flanged ends pressure rating PN 1.0 complete including taking out unserviceable NRV all as specified and as directed by Engineer-in-Charge. Note (i) - Flanged joints complete with rubber jointing materail shall deemed to be included in the unit rate of this item. (ii) Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying & Fixing , jointing and testing of cast iron Sluice Valve ISI marked (PN-1.0) confirming to IS 14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and gaskets complete all as specified and as directed. (Note:- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
100 mm bore
150 mm bore
200 mm bore
Supply and fixing in replacement of star delta starter type ML-1.5/MN Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply and fixing in replacement of star delta starter type ML-2/MN Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-3 Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-12 Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-6 Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-4 Motor of OEM make as per site condition of standard quality complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-1.5 Motor of OEM make as per site condition of standard quality complete all as specified and directed. (Note for ser item No 40 to 46 :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
M&L in replacement of phase failure relay with under and over voltage relay setting (variable) Auto reset 4%-20% unbalance with neutral tail protection type DZV MR-2 complete all as specified and directed.
M&L in replacement of panel mounting single phase preventor type VSP-II complete all as specified and as directed. (Note for ser item No 47 to 48 :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 10.00 Sq mm complete all as specified and as directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 16.00 Sq mm complete all as specified and as directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 25.00 Sq mm complete all as specified and as directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 50.00 Sq mm complete all as specified and as directed
M&L PVC insulated multistranded copper conductor wire 1100 volts in replacement single core of size 95.00 Sq mm complete all as specified and as directed. (Note for ser item No 49 to 53 :- Old unserviceable material copper cable shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 9-14 amp complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 13-21 amp complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50Hz of range 20-32 amp complete all as specified and as directed
S & F in replacement of biometallic thermal over load relay 415 V 50 Hz of range 28-42 amp complete all as specified and as directed
S & F in replacement of Amp Meter 0 to 100 Amp of size 96 mm x 96 mm Digital Type complete all as specified and as directed
S & F in replacement of Volt Meter 0 to 500 Volts of size 96 x 96 mm Digital Type complete all as specified and as directed. (Note for ser item No 54 to 59 :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
M/L in replacement of Indicating light complete all as specified and directed.
S&F in replacement moulded case circuit breakers 3 pole 400 Amps having breaking capcity 36 KA at 415 volts complete all as specified and directed.
S&F in replacement moulded case circuit breakers 3 pole 200 Amps having breaking capcity 36 KA at 415 volts complete all as specified and directed.
S&F in replacement moulded case circuit breakers 3 pole 160 Amps having breaking capcity 36 KA at 415 volts complete all as specified and directed.
S&F in replacement moulded case circuit breakers 3 pole 125 Amps having breaking capcity 36 KA at 415 volts complete all as specified and directed.
S&F in replacement moulded case circuit breakers 3 pole 100 Amps having breaking capcity 16 KA at 415 volts complete all as specified and directed. (Note for ser item No 61 to 65 :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
S&F in replacement Timer switch of OEM make complete all as specified and directed.
Disconnecting Electric connections from LT Control pannel and starter of non clogging submerssible Sewage pump set of any size 5 HP to 25 HP capacity and removing the pipe line connections from discharge side and taking out submersible pump set along with, column pipe from sewage sump with the help of chain pully block including transportation to workshop and back for repair and lowering of same pump in sewage sump after repair including replacement of rusted nuts bolts, rubber gasket complete all as specified and as directed.
Notes :- (a) Serviceability of submersible motor after repair shall be got tested by EIC before installation and refixing at site. (b) Each motor maintenance / functionality / ser viceability will be covered for one year after satisfactory repaired and if induction motor winding brunt out in the contract period or within defect liability period of one year, the same will be repaired by contractor free of cost at his own arrangement and risk. (c) Repair / Maintainance of submersible motor shall be carried out from OEM authorised workshop only after getting approval of GE. (d) A BOO will be ordered for verification of serviceable & functionality of motor after repair from workshop and the same will kept on record duly concurred by GE. (e) Spare parts & copper winding shall be measured and paid seperately under respective items as supply only.
Labour for opening the non-clogging submerssible Sewage pump set, repairing, rewinding and assembling the pump set including insulating material of any size 5HP to 10 HP capacity complete all as specified and as directed. (Note:- Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only)
Labour for opening the non-clogging submerssible Sewage pump set, repairing, rewinding and assembling the pump set including insulating material of any size 12.5 HP to 25 HP capacity complete all as specified and as directed. (Note:- Copper winding wire and other spare parts required for repairing will be measured and paid under relevant item as supply only)
Supply only in replacement following spare parts for non-clogging sewage submersible pump set vertical type (KRTU type) of capacity upto 25 HP
SS rotor sleeve
SS rotor shaft ASS 410
Water Seal
Connection Plate
Remetaling of rotor & turning/grinding
GM suction ring
GM/SS Impeller
SS stud with nut
Impeller Nut
Impeller Key
Joint of submersible cable
Repairing of stamping of stator
Jointing of cable kit without float switch
CI suction plate
O Ring set
Insulation kit
Temperature sensor
Moisture sensor
Ball bearing 6312ZZ
Roller Bearing 3310
Roller Bearing NU 305
Bearing 6306 2RS1/C3
Bearing 6308 2RS1/C3
Bearing 6309 2 R S1/C3
Bearing 3212
Mechanical seal
(Note for ser item No 70 :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
Supply and laying & testing in replacement of submersible copper cable flat / rount of size 10sqmm 3 core complete all as specified and directed. (Note :- Old unserviceable material submersible cable shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
Supply and fixing in replacement CI Casing body of pump cap 40/50 HP kirloskar make as site with and including Installation testing allignment and nut bolt washer etc complete all as specified and as directed. (Note :- Old unserviceable materialCI Casing body shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
M&L earthing complete with galvanised steel earth plate electrode 60x60 cmx 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below nominal ground level) with top edge of plate not less than 1.5 mtr below normal ground level connected to galvanised iron strip 32x6 mm as earthing lead by mean of bolts, nuts, check nuts and washer of galvanised iron or steel all as shown in Electrical plate No-3 connected to earthing test point all as specified or indicated including testing on completion including taking out of existing unserviceable earthing complete all as specified and directed. (Note:- (i) GI strip 32x6mm upto 7.5Rm shall be included in quoted unit rate and if extra required the same shall be measured and paid seperately under respective items. (ii) Old unserviceable material iron scrap shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
S&F in replacement GI Earthing strip 32x6mm including nut bolts and connecting items complerte all as specified and as directed. (Note (i) :- Old unserviceable material iron scrap shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
Supply and fixing LED street light fitting 70Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. (Note :- Old unserviceable material shall be taken on charge and enter in demolition / salvage register in 'KG' and attach the same page of salvage register with each RAR.)
M&L for replacing U/s gland packing champion of pump set of any capacity at site complete all as specified and as directed. (Note:- Old U/s gland plate obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
S&F in replacement of pressure gauge (0-10 Kg/Sqcm) with connecting accessories of suitable size for pumps complete all as specified and directed.
M/s Shri Shyam Bharat Builders
B.R. Enterprises
M P TYAGI ENGINEERS AND CONTRACTORS
PRASAD ELECTRICALS
KUSHAL ENTERPRISES
P S TRADERS
M/s Dhapola Elevator and Engineering
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .