Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹53,376Qualified Make: BPE
Model: BPE, BP1000 OPP DESHBANDU COLLAGE SOUTH DELHI DELHI 110019 | SOUTH EAST DELHI | DELHI | 110019 | Make: BPE
Model: BPE, BP1000 | L1 | Qualified | |
| 2 | L2₹53,968+₹592 (1.11%)Qualified Make: BPE
Model: BPE NIY 1KVA LINE INTRACTIVE UPS 7AH 2NOS 2YEARS AAREY MILK COLONY MUMBAI MAHARASHTRA 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Make: BPE
Model: BPE NIY 1KVA LINE INTRACTIVE UPS 7AH 2NOS 2YEARS | L2 | Qualified | |
| 3 | L4₹61,584+₹8,208 (15.4%)Qualified Make: ELNOVA
Model: I-1002-7-AH 19 103 NEW MALHAR SAHARA STATES JANKIPURAM LUCKNOW UTTAR PRADESH 226021 | LUCKNOW | UTTAR PRADESH | 226021 | Make: ELNOVA
Model: I-1002-7-AH | L4 | Qualified | |
| 4 | L5₹61,600+₹8,224 (15.4%)Qualified Make: BPE
Model: BPE UPSX1101L2 548 C 254 CHANDRODAYA NAGAR DEVPUR RAJAJIPURAM LUCKNOW LUCKNOW UTTAR PRADESH 226017 | LUCKNOW | UTTAR PRADESH | 226017 | Make: BPE
Model: BPE UPSX1101L2 | L5 | Qualified | |
| 5 | L5₹61,600+₹8,224 (15.4%)Qualified Make: BPE
Model: BPE, BP1000 C 10 SAGAR MARKET 25 16 KARACHI KHANA KANPUR KANPUR U P 208001 | KANPUR NAGAR | UTTAR PRADESH | 208001 | Make: BPE
Model: BPE, BP1000 | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
11 Oct 2018, 10:00 amClosed
Line Intractive UPS with AVR Line Intractive UPS With AVR ( 16 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 SMF-VRLA confirming to JISC-8702 Pt 1
2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC
50 Hz Single Phase Quasi-Sin- wave 230 V AC
50 Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year 1 year Warranty for Line Interactive UPS 2 Years 2 Years Installation and commissioning instructions No * 1/4 CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9%
50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts
the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree
RH -95% for 2-cycle as per IS:9000 Yes * 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Kumar Pandey 801103
AIR FORCE STATION BIHTA NEAR MUSEPUR 16 15
656349
GEM/2018/B/93109
Line Intractive UPS with AVR
15 days
Bihar; Patna
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Line Intractive UPS with AVR Line Intractive UPS With AVR ( 16 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERIC Rating in KVA/min VAH capacity of battery (KVA/VAH) 1.0/168 1.0/168 Technology MOSFET-PWM MOSFET-PWM Type of battery SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 SMF-VRLA confirming to JISC-8702 Pt 1 | - | - | - |
| 2 &3 Rated Output (Volt) Single Phase Quasi-Sin- wave 230 V AC | - | - | - |
| 50 Hz Single Phase Quasi-Sin- wave 230 V AC | - | - | - |
| 50 Hz Degree of protection IP-21 IP-21 Inverter Efficiency (%) >/= 70% >/= 70% Warranty for the battery from the date of delivery 1 year 1 year Warranty for Line Interactive UPS 2 Years 2 Years Installation and commissioning instructions No * 1/4 CONSTRUCTIONAL Type of enclosure ABS * AC out put for printer (not through inverter) Yes Yes Inverter out put socket AC out put for printer (not through inverter) 3 Three pin 3 Three pin FUNCTIONAL Total harmonic distorsion (%) </= 40% * Input (Volt) Single phase sinewave(160-280v) * Switching over time (Mili sec) Maximum 10 milli seconds * Overload Time (Minutes) >/= 10 minutes * Load power factor >/= 0.6 * Variation in AVR output in AC mode (%) AVR (Voltage regulation) output voltage in AC Mode 230 Volts +/-9% | - | - | - |
| 50 +/-3 Hz * Overload (%) >/=10% * Variation in output voltage in battery mode (%) (UPS output voltage in battery mode) 230 Volts +/- 10% * Variation on output frequency in battery mode (Hz) </=0.5 * PROTECTION Protection against (over discharge) discharge per 12v battery (Volt) 10.5 * Protection for outside input voltage range: If Input voltage goes outside the range 160 to 280 Volts | - | - | - |
| the system shall switch over to battery mode Yes * Protection against short circuit of UPS Yes * Protection for over voltage and over load Yes * REPORTS AND CERTIFICATIONS Damp heat Test at 45 degree | - | - | - |
| RH -95% for 2-cycle as per IS:9000 Yes * 2/4 pt-5/sec-1 Dry heat Test at 45 degree for 16 Hrs as per IS:9000 pt-3/sec-5 Yes * Cold Test as per IS:9000 pt-2/sec-4 Yes * Availability of the type test report from central Govt./NABL/ILAC Accredited Lab Yes * Type Test certificate no. and date - * Name Of Lab - * Address of Lab - * As per Meity (Government of India) guidelines UPS shall have valid BIS CRS certifications as applicable Yes * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Arun Kumar Pandey 801103 | - | - | - |
| AIR FORCE STATION BIHTA NEAR MUSEPUR 16 15 | - | - | - |
Exempted
11 Oct 2018
26 Sept 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_656349.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .