Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
27 Jul 2024, 4:00 pmClosed
Executive Engineer ED-II JPDCL
Executive Engineer ED-II JPDCL
Rate contract for laying of 11KV line and creation of 11KV Isolation Point on 9 Mtr. PCC Poles using ACSR Weasel/Rabbit conductor at different locations within the jurisdiction of Electric Division-II Jammu during the Financial Year 2024-25
2024_PDD_252144_1
Enit 22 of 2024 Dated 05-07-2024
Open Tender
Electrical Works
Turn-key
30 days
ED-II JPDCL
As per ENIT/SBD.
8 documents required · 8 mandatory
₹500
Executive Engineer ED-II JPDCL
₹16,000
2 Aug 2024
5 Jul 2024
29 Jul 2024
5 Jul 2024
27 Jul 2024
5 Jul 2024
Amount
Particulars of works for erection of 11KV line with ACSR Weasel Conductor on 9 Mtrs PCC poles
Erection of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation from Divisional Store at Miran Sahib to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator with fitting 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanized Nuts and Bolts
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Providing & Fixing of Stone Pad (300 mm x 300 mm x 75 mm)
Providing & Fixing of Aluminium Jointing Sleeves
Providing & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Particulars of works for erection & commissioning of Isolation point
Erection of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation from Divisional Store at Miran Sahib to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply ,Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire
Providing & Fixing of PG Clamps for 30mm² ACSR Conductor
Supply, Installation, Testing & Commissioning of 11 KV GO AB Switch, 3-phase, 3-pole, 400 Amp.
Supply, Installation, Testing & Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, line Type
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip(2 nos for ST poles & ino. For G O Switch/LA)
Providing of Stone Pad 300 mmx300mmx75mm
Description of Work / Item(s)
Amount
Particulars of works for erection of 11KV line with ACSR Rabbit Conductor on 9 Mtrs PCC poles
Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation from Divisional Store at Miran Sahib to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply, Transportation, Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Laying & Stringing of ACSR Rabbit Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of PG Clamps for 50mm² ACSR Conductor
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator with fitting 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of Galvanized Nuts and Bolts
Providing & Fixing of Danger Plates with Clamps
Providing & Fixing of Anti-Climbing Device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Providing & Fixing of Stone Pad (300 mm x 300 mm x 75 mm)
Providing & Fixing of Aluminium Jointing Sleeves
Providing & installation of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Particulars of works for erection & commissioning of Isolation point
Erection, Testing & Commissioning of 9 Mtr Long PCC Pole (WL-300Kg) including Transportation from Divisional Store at Miran Sahib to erection site, excavation of pit and back filling of soil & consolidating by ramming, watering etc.
Supply ,Fabrication & Fixing of MS Channel Iron, Cross arms, Angle Iron Braces, Clamps etc duly fabricated, red oxide & aluminium paint coated including all necessary Nut & Bolts & Washers etc.
Laying & Stringing of ACSR Weasel Conductor on Cross arms through insulators including proper binding & twisting with soft Aluminium Wire.
Providing & Fixing of PG Clamps for 50mm² ACSR Conductor
Supply, Installation, Testing & Commissioning of 11 KV GO AB Switch, 3-phase, 3-pole, 400 Amp.
Supply, Installation, Testing & Commissioning of Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, line Type
Providing & Fixing of 11kV Polymeric composite Pin Insulator 12kV, 10kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing & Fixing of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply & Fixing of Stay Set with 50 x 8 mm Stay Clamp, Guy Insulator (2 Nos), Anchoring Plate (200 x 200 x 6 mm), Nut & Bolts, 2 No Turn Buckle, 1.8m long, 16 mm diameter solid Stay Rod & 7/3.15 mm dia stranded wire complete
Supply & Fixing of Danger Plates with Clamps
Supply & Fixing of Anti Climbing device with Clamps
Providing of Earthing Complete by GI Pipe 40 mm or GI Rod 20 mm, 2.5 Mtr Long through GI Strip(2 nos for ST poles & ino. For G O Switch/LA)
Providing of Stone Pad 300 mmx300mmx75mm
M/S A A ENTERPRISES
M/S RAJ ELECTRICAL CONTRACTOR
M/S SINGH ELECTRICALS
M/S NEW TRIKUTA TECHNOCRATES
M/S DAYAL BUILD TECH
JASMEET SINGH
M/S PVM INFRA
AJAY KAPOOR
VEENA CONSTRUCTION CO.
M/S A G ELECTRICALS
M/S RAJ ELECTRICAL CONTRACTOR
M/S RATHER CONSTRUCTIONS AND TRADERS
JASMEET SINGH
M/S DAYAL BUILD TECH
M/S A A ENTERPRISES
M/S A G ELECTRICALS
M/S NEW TRIKUTA TECHNOCRATES
M/S PVM INFRA
AJAY KAPOOR
VEENA CONSTRUCTION CO.
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .