Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.1 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹16.6 L+₹55,885 (3.48%)Rejected-Finance 31 TILAK NAGAR SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | 2 | Rejected-Finance Not Lowest | |
| 3 | 3₹17.7 L+₹1.6 L (10.0%)Rejected-Finance | 3 | Rejected-Finance Not Lowest | |
| 4 | 4₹18.2 L+₹2.2 L (13.4%)Rejected-Finance CHANDPURA TIKAMGARH DIST TIKAMGARH MP | TIKAMGARH | TIKAMGARH | MADHYA PRADESH | 4 | Rejected-Finance Not Lowest | |
| 5 | 5₹18.8 L+₹2.8 L (17.3%)Rejected-Finance | 5 | Rejected-Finance Not Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
3 Dec 2020, 6:00 pmClosed
Garrison Engineer Abohar
Garrison Engineer Abohar Pin 152116
REPAIR/MAINT AND REPLACEMENT OF SUBMAIN WIRING DISTRIBUTION BOARDS AND ALLIED WORKS AT MIL STATION ABOHAR
2020_MES_385922_2
GE ABH-31/20-21
Open Tender
Civil Works
Item Rate
180 days
Abohar Mil Stn
MES Registered Contractor enlisted in class E Category b (i) having deposited standing security of Rs 50000 with departments. Contractors not registered in MES should meet the MES enlistment criteria corresponding to appropriate class and category
5 documents required · 5 mandatory
₹500
Garrison Engineer Abohar
₹40,000
Yes
3 Feb 2021
19 Nov 2020
5 Dec 2020
19 Nov 2020
3 Dec 2020
20 Nov 2020
Amount
M&L for submain wiring comprising single core ,4 Runs of 10 sqmm nominal cross sectional area multimultistranded copper conductor cable, PVC insulated unsheathed 1100 Volts grade drawing in and including appropriate dia. PVC conduits and conduit fittings complete, including provision of 2 x10 sqmm nominal cross sectional area multimultistranded copper conductor cable PVC insulated unsheathed 1100 Volts grade as earth wire complete incl taking down old UNSV sub main all as specified. ( Note :- Extra length of cables/ wire required for connection to MCBs shall not be measured and the rate quoted by contractor for per unit shall be deemed accordingly)
Description all as per Item No 1 herein before but 4 Runs of 6 sqmm nominal cross sectional area in PVC conduits and conduit fittings complete, including provision of 2 x 6 sqmm nominal cross sectional area as earth continuity wire all as specified.
Description all as per Item No 1 herein before but 4 Runs of 10 sqmm nominal cross sectional area in PVC casing and caping fittings complete, including provision of 2 X 10 sqmm sqmm nominal cross sectional area as earth continuity wire all as specified.
Description all as per Item No 1 herein before but 4 Runs of 6 sqmm nominal cross sectional area in PVC casing and caping fittings complete, including provision of 2 x 6 sqmm nominal cross sectional area as earth continuity wire all as specified.
Description all as per Item No 1 herein before but 2 Runs of 6 sqmm nominal cross sectional area in PVC conduit and its fittings complete, including provision of 1 x 6 sqmm nominal cross sectional area as earth continuity wire all as specified.
Description all as per Item No 1 herein before but 2 Runs of 6 sqmm nominal cross sectional area in PVC casing and caping fittings complete, including provision of 1 x 6 sqmm nominal cross sectional area as earth continuity wire all as specified.
Description all as per Item No 1 herein before but 2 Runs of 4 sqmm nominal cross sectional area in PVC casing and caping fittings complete, including provision of 1 x 4 sqmm nominal cross sectional area as earth continuity wire all as specified.
Description all as per Item No 1 herein before but 2 Runs of 4 sqmm nominal cross sectional area in PVC conduit and its fittings complete, including provision of 1 x 4 sqmm nominal cross sectional area as earth continuity wire all as specified.
M & L cutting chases, pinning in, making god to facings where reuired and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc ; and cutting chases for concealed water tubing or concealed wiring etc, and making good, cutting not exc 10 cm girth in brick walls complete all as specified.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable for service connection of size 2 core 10 sqmm nominal cross section in service connections of PVC insulated aluminium multi standard conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and directed by Engr-In-charge. Make- Havells/Plaza/Finolex/Kalinga/Kei/Anchor
All as per Item No 10 above here-in-before but 2 core 6 sqmm complete all as specified and directed.
All as per Item No 10 above here-in-before but 2 core 4 sqmm complete all as specified and directed.
S&F sheet metal enclouser VTPN/HTPN DB having facility to fix MCCB incomer upto 250 Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill protector,insulated bus bar assembly and blanking plates including making good disturbed surfaces after taking out old unserviceable DB complete all as specified and directed. Make- Indo Asian Model No: 811893 Legrand/L&T Hager/C&S/INDO KOPP/Standard/Havells
All as per Item No 13 above here-in-before but TPN DB 6 Way double door type complete all as specified and directed make- Indo Asian Model No: 811894 or equvalent Makes of- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
All as per Item No 13 above here-in-before but TPN DB 8 Way double door type complete all as specified and directed. make- Indo Asian Model No: 811895 or equvalent Makes of- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
All as per Item No 13 above here-in-before but TPN DB 12 Way double door type complete all as specified and directed. make- Indo Asian Model No: 811896 or equvalent Makes of- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
Taking down existing Old control board and supplying and fixing CRCA sheet metal board made of 2.0 mm thick metal sheet and painting 2 coats of synthatic enamel paint over a coat of primer inluding copper bus bar and fixed with wall for fixing 04 Nos of meters complete with wiring,fitting and accessories, locking arrangement with handle (not less than size of box 100cmx80cmx25cm and adequate depth for the following equipments,internal wiring and termination of external cables,lugs,glands,wire thimbles and conduit/flexible pipe for finishing as required) comprise of following:- (a) Incoming 63 Amps 4 pole MCCB 25 KA -01 Nos (b) Bus bar of 200 Amps TPN & Earth (c) 40 Amps DP MCB -04 Nos ( for Electric DU Meter) (d) 10 Amps DP MCB - 01 Nos ( out going for Stair case/garage light circuit) (e) Fixing only existing single phase KWH meter after taking out carefully for refixing in panel.
Taking down existing Old control panel board and supplying and fixing CRCA sheet metal panel board out door type made out of 3.15 mm thick metal sheet and painting 2 coats of synthatic enamel paint over a coat of primer inluding copper bus bar and fixed complete with wiring,fitting and accessories, locking arrangement with handle (not less than size of box 100cmx80cmx25cm and adequate depth for the following equipments,internal wiring and termination of external cables,lugs,glands,wire thimbles and conduit/flexible pipe for finishing as required) comprise of following:- (a) Incoming 100 Amps 4 pole MCCB 25 KA -01No (Adj thermal and Magnetic release) (b) Bus bar of 200 Amps TPN & Earth (c) 40 Amps DP MCB -04 Nos ( for Electric DU Meter) (d) DOL starter for 5 HP motor with motor relay for fountain - 01 Nos (e) MCCB 40 Amps 16 KA-02 Nos Adj thermal and Adj magnetic relase (out going for garden lights and road lights)
Supply and fixing MCCB TPN ( 4 pole) 63 Amps 415 Volts of braking capacity 36 KA (Adjustable Thermal and Adjustable Magnetic Release Setting) complete taking down old unserviceable one and making necessary connections as existing and cleaning the terminals with CTC solutions complete all as specified and directed. Make :IndoAsian or equvalent of Havells/LegrandSchneider/HPL/Standard
All as per Ser Item No 19 but 100 Amps with braking capacity 36 KA.
All as per Ser Item No 19 but 125 Amps with braking capacity 36 KA.
All as per Ser Item No 19 but 160 Amps with braking capacity 36 KA.
All as per Ser Item No 19 but 200 Amps with braking capacity 36 KA.
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser TPN DB having facility to fix MCCB incomer upto 125Amps and MCBs in outgoing, TPN 4 ways, Double door type complete fitted with bus bars, neutral links, IP-43 protection Isolated Neutral bar,door earthing,cement spill ptorector and blanking plates including making good disturbed surfaces complete all as specified and directed. Make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
Dismantling of existisng unserviceable MCB distribution board and S&F sheet metal enclouser SPN DB having facility to fix MCB in incomer and MCBs in outgoing, SPN 12 ways, Double door type complete fitted with bus bars, neutral links, blanking plates including making good disturbed surfaces complete all as specified and directed. Make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells
All as er Item No 25 but MCB DB SPN 8 ways complete all as specified.
All as er Item No 25 but MCB DB SPN 4 ways complete all as specified.
Supply and fixing Plug and socket type DB (Functional Unit) 20 Amps capacity with provision of single pole 20 amps MCB, plug top and earth plug, grouted flush to walls complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
Supply and fixing Plug top type 20 Amps 3P+E, 230 Volt capacity of plug top and earth plug, complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
Supply and fixing plug top type 20 Amps 3P+E, 230 Volt capacity of Socket with safety cap complete all as specified. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells Schneider/C&S)
Supplied and fixed Miniature circuit breaker (MCB), single pole, 240 Volts, of 6-32 amps current rating and 10 KA breaking capacity, B' series type complete all as directed by Engr-in-charge. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Supplied and fixed Isolator TPN, 415 Volts, of 63 amps current rating complete all as directed by Engr-in-charge. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Supplied and fixed Isolator TPN, 415 Volts, of 100 amps current rating complete all as directed by Engr-in-charge. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Supplied and fixed Isolator, Double pole, 240 Volts, of 32 amps current rating complete all as directed by Engr-in-charge. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Supplied and fixed Isolator, Double pole, 240 Volts, of 40 amps current rating complete all as directed by Engr-in-charge. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Supplied and fixed Isolator, Double pole, 240 Volts, of 63 amps current rating complete all as directed by Engr-in-charge. Make-Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Suuply and fixing on load change over switches 4 pole in sheet steel enclosure of 63 amps complete all as specified and directed Make: Make-Indoasian Cat: ITAS0063 or equvalent of Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Suuply and fixing on load change over switches 4 pole in sheet steel enclosure of 100 amps complete all as specified and directed Make: Make-Indoasian Cat: ITAS0100 or equvalent of Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Suuply and fixing on load change over switches 4 pole in sheet steel enclosure of 125 amps complete all as specified and directed Make: Make-Indoasian Cat: ITAS0125 or equvalent of Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Suuply and fixing on load change over switches 4 pole in sheet steel enclosure of 160 amps complete all as specified and directed Make: Make-Indoasian Cat: ITAS0160 or equvalent of Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
Suuply and fixing on load change over switches 4 pole in sheet steel enclosure of 200 amps complete all as specified and directed Make: Make-Indoasian Cat: ITAS0200 or equvalent of Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/ Schneider/C&S)
M&L for Earthing complete with GI earth plate electrode of size 600x600x6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel, protected by galvanized iron pipe 40mm bore (Medium grade) all as directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel, wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and directed after taking down old earthing.( GI wire upto 7.5m including testing consider in this item).
M&L for cable end jointing kit for LT, 1100 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 70 sqmm complete all as specified and directed. Make: Denson/3M or equivalent
M&L for cable Straight throgh jointing kit for LT, 1100 Volt (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 16 to 70 sqmm complete all as specified and directed. Make: Denson/3M or equivalent
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 4 core including taking down old unserviceable complete all as specified. Make: Kalinga/ Plaza/Gloster/ Havells/ Finolex/POlycab/Kei or equvalent makes
All as per item above herein before but the size cross-sectional area 10 sq. mm 4 core
All as per item above herein before but the size cross-sectional area 16 sq. mm 4 core
All as per item above herein before but the size 25 sqmm 4 core
All as per item above herein before but the size 35 sqmm 3.5 core
All as per item above herein before but the size 50 sqmm 3.5 core
All as per item above herein before but the size 70 sqmm 3.5 core
Excavation in trenches not exceeding 1.5 mtr depth width and not exceeding 1.5m depth for laying under ground cable in loose/soft soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm.
Removal of surplus soil obtained from excavated material not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point.
M&L for sand cushioning for protection of PVC cable with screen wash river sand and punning to proper required cover.
M&L for PCC preparation including cutting up to 45 cm width and depth of the road/hard standing and making good disturbed surfaces by using PCC type C2(1:3:6) by using 40mm graded stone aggregate for the fixing the pipe/laying cables complete all as directed by the Engr. in Charge.
M&L for 40mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. (MAKE: JINDAL/PRAKASH/SURYA)
M&L for 50mm dia steel tubes (light grade) galvanised with fittings, laid in trenches/wall for protection of underground earth strip when crossing the road/fixing on wall as in repair complete all as specified and directed. (MAKE: JINDAL/PRAKASH/SURYA)
M&L for bricks of sub class ‘B’ bricks, for cable protection in trenches laid dry and flat.
Taking down defective street light of LED of capacity 25/30/60/90/120W, Bldg flood light and building security light fitting of any type from their existing position i.e, Multi store bldgs/poles and refixing the same after repairs carried out. Note: (i) LED driver/LED Strip,, and SPD, PVC wire/cable will be measured and paid separately under respective items of the BOQ (ii) Cost of nut, bolts & washers for fixing new items is included in the unit rate of items.
Supply only surge protection device (SPD) of capacity 8 KV with phase neutral and earth wire incoming and outgoing both sides complete all as specified and directed. Make: Havells/Philips/CG/syska/Bajaj/
Supply only surge protection device (SPD) of capacity 5 KV with phase neutral and earth wire incoming and outgoing both sides complete all as specified and directed. Make: Havells/Philips/CG/syska/Bajaj/
Supply &fixing LED driver 18/20/22 W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed.
Supply &fixing LED driver 36/40 W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed.
Supply &fixing LED driver 60 W LED recess/surface light fitting Indoor type suitable for existing light fitting as per sample complete all as specified and directed.
Supply only LED driver 20/25 W LED bldg/pole street light fitting complete all as specified and directed.
Supply only LED driver 30 W LED bldg/pole street light fitting complete all as specified and directed.
Supply only LED driver 60/90W W LED bldg/pole street light fitting complete all as specified and directed.
Supply only LED Strip for 20/25W LED bldg/pole street light luminaries complete all as specified and directed
Supply only LED Strip for 30W LED bldg/pole street light luminaries complete all as specified and directed
Supply only LED Strip for 60/90W LED bldg/pole street light luminaries complete all as specified and directed
Material and labour for brackets suitable for building security light fittings made out of light grade 20 mm dia GI tubing bent to shape of up to 2.5 meter length complete with aluminium painting of two coat and necessary nuts, bolts and clamps including taking down old unserviceable compelete all as directed by Engr-in-charge.
S&F LED tube light fixture with batten fitting, environmental friendly energy efficient ready to use 18/20W LED 6500K and above (4') complete all as specified and directed by Engr-In-charge. Make:Syska Price SSK-ALB-20W I & SSK-TL-20W I or equvalent.
S&F batton for LED tube light fixture with extruded aluminium heat sink, environmental friendly energy efficient ready to use with 18/20 W LED 6000K and above (4') including electric connection complete all as specified and directed by Engr-In-charge. Make: Havells/Crompton Greaves/ Philips/Wipro/Syska/polycab
S&F for LED tube light fitting of LED T5 tube lights (6500K) environomental freiendly energy efficient of 18/20 Watt LED including electric connection complete all as specified and directed by Engr-In-charge. Make:Syska SSK-SQ2001 20W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab
S & F LED bldg street light luminaitres 20/25 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-ST25W-MG or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab
S & F LED bldg street light luminaitres 15 watts with IP66 complete with pressure dia cast aluminium housing with GI pipe bracket made out of 25 mm dia medium grade pipe (60 cm long) bend to shape including fixing arrangement to wall with MS flat 25x3mm-2 Nos by nut, bolts and washers including electric connection complete all as specified and directed by Engr-In-charge. Make:Syska max glow series SSK-MST 15W or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Polycab
S&F for Skylux LED efficient LED surface 2'x2' luminaire & glare free soft illumination of capacity 36Watt LED white colour inlcuding connection complete all as specified and directed by Engr-In-charge. Make:Bajaj BZSSQL 36W LED WH or equvalent of Havells/Crompton Greaves/ Philips/Wipro/Syska
S&F for Galaxy LED suspended type decorative LED low bay luminaasire white colour of capacity 24 Watt complete all as specified and directed by Engr-InCharge Make: Bajaj BLSPD LED 24W WH or equivalent in Havlls/Crompton Greaves/ Philips/Wipro/Syska.
S&F for WEE Plus LED bulk head luminaire of capacity 10 Watt an ideal energy efficient solution for upgrading conventional GLS bulkhead luminaires to LED bulk head IP 65 including connections complete all as specified and directed by Engr-InCharge Make: Bajaj BIBWP LED 10W WH or equivalent in Havlls/Crompton Greaves/ Philips/Wipro/Syska
S&F for LED building street light luminaire of capacity 20 Watt with pressure die-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07 including connections complete. Make: Bajaj BRLEPLED 20W LED V2 or equivalent in Havlls/Crompton Greaves/ Philips/Wipro/Syska as approved by GE.
S&F for LED building street light luminaire of capacity 60 Watt with pressure die-cast housing with individual LEDs as light source and lens embedded PC cover having TOP opening separate driver compartment with IP 66 protection and impact resistance of IK 07 including cocnnections complete. Make: Syska cat No SSK-SLF-CF-60W or equavalent of Bajaj/Havlls/Crompton Greaves/ Philips/Wipro/polycab.
Supply only fan regulator electronic (socket) type, single phase, 230Volt complete all as specified and directed Make: Anchor/Cona or equivalent.
Taking out faulty underground 1100 volt grade LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or rerouting after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed. Note:1. New LT cable replace with fault portion ,joints shall be measured and paid separately under respective items of the schdule. 2. Retrived old serviceable bricks will be laid in trenches for cable protection. if extra bricks and sand required at site shall be measured and paid separately under respective items of the schdule. 3. Earth work and excavation will be measured and paid separately under respective items of the schdule.
Material and labour for disconnecting faulty/burnt end portion of cable by removing the cable from loop including necessary excavation & earth work, relaying and reconnecting the cable by removing faulty/burnt portion of incoming and out going cables at pole connection/panel boards and preparing fresh terminals with suitable size of thimbles,lugs and glands or gland plates as suitable of any size and number of cables incoming out going at panel board`
M&L for Boring hole across the Road/plinth/hardstanding/path/drain/pavement etc., suitable for inserting HDPE/GI pipe of upto 100mm dia bore for cable passing without damaging existing Raod/path/hardstanding/floor using necessary equipment complete all as specified and directed.Make-Legrand/L&T Hager/C&S/INDO
Supply and fixing MCB TPN 100 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand or equivalent
Supply and fixing MCB TPN 63 Amp, 10 KA 415 Volt in repair. Make : Havells/Legrand or equivalent
Demolishing the broken earth pit chamber and constructing new earth pit chamber and provisionn of PCC/MS chamber cover and funnel complete as per SSR Pt -I of 1996 all as directed.
S&F 1.5 sqmm 3 core, 1100 volt grade heavy duty cable, PVC insulated copper multistranded conductor, served with inner sheathing of PVC tape and overall PVC sheathed for making connection of street light from FRP junction box/OH line to street lights complete all as specified and directed
Supply only aluminium lugs suitable for cable of size 10 to 16 sqmm complete all as specified and directed.
Supply only aluminium lugs suitable for cable of size 25 sqmm complete all as specified and directed.
Supply only aluminium lugs suitable for cable of size 35 sqmm complete all as specified and directed.
Supply only aluminium lugs suitable for cable of size 50 sqmm complete all as specified and directed.
M&L for removing connections of faulty cable from both ends of LT terminaton from panel to building feeder piller after meggaring and confirm the faulty cable all as specified and directed and finding the spot of the cable faulty position with any other mechanism like cable fault locator or manual with necessary earth work made and remove the cable from the trench and jointing the cable to serviceable condition after necessary meggaring values obtain and shifting or relaying the cable all as specified and directed by Engr-InCharge. Note: 1. Earth work for the cable removing. laying and necessary joint material measured and paid separately under relevent items of the schedule. 2. skilled operator/instruments involved for positioning the cable fault location is deemed to be included in the rates quoted.
M&L for test point terminal box made of gunmetal or phosphorus bronze size 75 x 75 x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal heads screw for lighting conductors complete all as specified and directed.
Relaying old bricks of any type and size bricks, for cable protection in trenches laid dry and flat.
Taking down care fully existing burnt/faulty/loose incoming and out going cables connections from building dist panel to pole of any size and removing carefully unserviceable switch gears/DB's and measuring instruments for reuse/refixing of serviceable items and repair/maint and servicing of existing Bldg dist panel by replacing hinges,switch gear compartments with rubber sheal,locks, nuts,bolts and washers and provn of danger notice boards, indicators of three nos with colour coding as existing and tape bus bar with insulation sleeves to three phases and neautral with colour coading and painted with two coats powder coating primer and also reconnecting all cables in same position with suitable glands,gland plates,aluminium lugs, nut bolts and washers after cleaning with CTC solution and apply silica gel to terminal junctions. Note: Supply and fix Switch gears against unserviceable measured and paid separately with relevent items of this schedule.
Supply and fix Bldg street light timer enclosed out door box canopy arrangment 3 phase,40 Amps, 3 pole , 230 volt Astronomical time switch complete with all accessories i.e MCB 40 Amps TPN, Astronomical time switch 24 Hrs with timer, contactor,fuse unit,indicator lamp,rotary switch and in coming and out going connector etc including prewired complete all as specified. Make: IndoAsian Cat: TL040ASO and equivalent in make Havells/ L&T/CG/Standard/Siemens/Legrand
S&F lamp holder angle/Batten, two brass terminals with LED lamp 9 Watt or more capacity including connection complete all as specified and directed. Make: Anchor/Wipro/Polycab/Syska/CG/Philips
Supply and fix in replacement digital voltmeter 0 - 500 Volts
Supply and fix in replacement digital ammeter 0 - 500 Volts
Supply and fix in replacement neon indicating lamp (Red, Yellow, Blue)
S&F PVC enclouser SPN DB 2 way having facility to fix MCB DP/SPN 2 ways complete fitted with bus bars, neutral links including provision of MCB DP 6-16A and making good disturbed surface area complete all as specified and directed. Make- Legrand/L&T Hager/C&S/INDO KOPP/Indo Asian/Standard/Havells/Topson
Singla Electricals
SHRI SHYAM CONSTRUCTION CO.
POOJA CONSTRUCTION COMPANY
ROYAL BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .