Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹5.6 Cr
EMD Value
₹8.3 L
Closing Date
18 Oct 2024, 9:30 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Mangalore Electricity Supply Company Limited
Mr Shivakumar
Reconductoring of old deteriorated rabbit ACSR conductor by Coyote ACSR conductor of 33kV Balehonnur- Sringeri SC line from 66/33/11kV Balehonnur Sub-Station to 33/11kV Sringeri Sub-station to a distance of 32.96Rkms using 11m Spun & 9.5m RCC Poles in Sringeri Sub division of Koppa Division on Total Turnkey Basis
MESCOM/2024-25/EL/WORK_INDENT240
MESCOM/2024-25/EL/WORK_INDENT240
Open
Electrical
Two Tender Document System(Two Cover)
MESCOM Superintending Engineer Procurement Corporate Office Managaluru
11 documents required · 11 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
Above Sl.No.1 to Sl.No.12 in Technical criteria is not applicable for this tender. Refer to the clause no. 8.0 of NIT & clause no 5.0 of Invitation For Bids of Volume-I of Bid document for the pre-qualifying requirement of this tender.
₹5,000
₹8.3 L
18 Sept 2024
18 Sept 2024
19 Oct 2024
3 Oct 2024
3 Oct 2024
Reconductoring of old deteriorated rabbit ACSR conductor by Coyote ACSR conductor of 33kV Balehonnur- Sringeri SC line from 66/33/11kV Balehonnur Sub-Station to 33/11kV Sringeri Sub-station to a distance of 32.96Rkms using 11m Spun & 9.5m RCC Poles in Sringeri Sub division of Koppa Division on Total Turnkey Basis-Supply Portion
Pre - Stressed Tubular Spun Pole 11 M Long - 500 Kg WL
33 KV DP Structure without Poles
RCC Pole - 9.5 Mtr Long, 350 Kg WL for 33kV Line
Clamp 9.5M RCC Pole for 33kV
Spiral Earth Electrode
Horizontal X arm for 33kV
Clamps for 11 mtrs Spun Pole
HT ST Support for 33 kV
Coyote ACSR Conductor
C - Type Wedge Connector-Coyote to Coyote ACSR
33 kV, 800 A, 25 kA Isolators, double break with manual operating mechanism, with solid core insulator, terminal connector suitable for Al. tube/conductor, marshalling box etc., complete-Upright witho...
H Frame for 33 KV GOS
33kV Polymer Pin Insulators
33kV 70 KN Polymer Insulator (Ball & socket type)
Guy set with 2 Nos. 15 Strain Insulator & concreting materials
Guarding Materials above 40 mtrs span
Earthing Material Set
Anti Climbing Device-GI Barbed wire (12 Mtr/Kg)
33 KV Danger Board
PG Clamps for Coyote to Coyote
Number Plates with Bolt & Nuts
Rabbit ACSR Conductor
Single Tension Clamps Suitable for Coyote ACSR Conductor
B & N Size 16x100mm-MS
B & N Size 16x150mm-MS
B & N Size 16x175mm-MS
B & N Size 16x200mm-MS
B & N Size 16x225mm-MS
Reconductoring of old deteriorated rabbit ACSR conductor by Coyote ACSR conductor of 33kV Balehonnur- Sringeri SC line from 66/33/11kV Balehonnur Sub-Station to 33/11kV Sringeri Sub-station to a distance of 32.96Rkms using 11m Spun & 9.5m RCC Poles in Sringeri Sub division of Koppa Division on Total Turnkey Basis-Erection Portion
Erection of 11 mtrs long concrete spun pole in a pit of 2.5 mtr depth
Digging of Pit 2.5 mtr depth for erection of 11mtr long tubular spun pole
Erection of DP structure
Erection of RCC Pole 9.5 Mtr long 350 Kg WL in a pit of 2.0 Mtr depth for 33KV line
Digging of Pit 2.0 Mtr depth for erection of 9.5 Mtr Long RCC supports
Providing Spiral Earth Electrode type earthing
Stringing of Conductor Coyote ACSR
Erection of H Frame
Erection of Isolators Assembly, Erection Alignment and Wiring including Movement from the point of Unloading to Point of Erection (Upright)
Digging of Pit for GUY SET
Fixing of guy sets with break insulators making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement using 2 No.15 strain insulators
Guy concreting with Boulders, Mud & Sand (300x300x450 mm)
Fixing guarding including fixing of necessary cross arms between HT and LT line
Fixing of Danger Board
Digging of pit for providing GI Pipe type Earthing
Providing GI Pipe Earthing for lightning arrestors Transformer Neutral and Transformer Metal parts
Base concreting-For 11m Spun Pole (1000x1000x150 mm)
Pole concreting (without coping)-For 11m Spun Pole (1000x1000x2500 mm)
Coping for Poles-390 mm all around the pole for an height of 300 mm for 11m Spun Pole (1130x1130x300 mm)
Base concreting-For 9.5m Pole (500x650x150 mm)
Pole concreting (without coping)-For 9.5m Pole (650x500x1850 mm)
Coping for Poles-150 mm around pole for an height of 300 mm for 9.5m RCCPole(400x400x300 mm)
Loading and unloading of poles (loading of poles to vehicles at stores and unloading at workspot) - 9.5M Long 350 kg WL RCC Poles for 33kV Lines
Loading and unloading of poles (loading of poles to vehicles at stores and unloading at workspot)Pre - Stressed Tubular Spun Pole 11 Mtr Long - 500Kg WL
Releasing & Refixing 33 KV Polymer Insulators
Releasing & Refixing of 9m RCC Released Good Poles Used As Stud Poles
Fixing of 33 KV horizontal cross Arms including Single Top Support Brace and Insulator fixing
Fixing of Anti Climbing Devices
Head Transportation of 11m Spun Poles
Head Transportation of 9.5m RCC Poles
Trimming of trees and branches and clearing
Fixing of number plate
Releasing of RCC poles
Releasing of RCC DP Structure with poles
Releasing of I Beam Poles
Releasing of A Type Towers
Releasing of 33 KV crossarms
Releasing of Rabbit Conductor
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
4 Techno-commercial sheets (33kV Balehonnuru to Sringeri).xlsx
Others - 3 TC Sheets • 0.04 MB
3 Vol 2 - 33kV Balehonnuru to Sringeri.docx
Others - 3 Volume-II • 3.86 MB
1 NIT- 33kV Balehonnuru to Sringeri.docx
Others - 1 NIT • 0.05 MB
2 Vol 1 - 33kV Balehonnuru to Sringeri.docx
Others - 2 Volume-I • 0.80 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .