Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.1 L+₹1.7 L (4.22%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹41.7 L+₹2.3 L (5.96%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹42.4 L+₹3.0 L (7.72%)Rejected-Finance SECUNDERABAD | WARANGAL | TELANGANA | 506350 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹44.4 L+₹5.1 L (12.8%)Rejected-Finance | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹48.5 L
EMD Value
₹97,100
Closing Date
9 Oct 2024, 6:00 pmClosed
GE MCEME SECUNDERABAD
GE MCEME SECUNDERABAD
SPECIAL REPAIRS TO BLDG No P 66 MI ROOM AT MCEME SECUNDERABAD UNDER GEMCEME SECUNDERABAD
2024_MES_675044_1
GE/MCEME/TOKEN/ 18 /2024-25
Open Tender
Civil Works
Item Rate
180 days
SECUNDERABAD
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE MCEME SECUNDERABAD
₹97,100
Yes
14 Dec 2024
18 Sept 2024
14 Oct 2024
18 Sept 2024
9 Oct 2024
1 Oct 2024
Amount
Demolition of cement concrete of any description and position and debrises off the premises complete all as specified.
M&L 25mm thick PCC (1:2:4) type B0 using 12.5mm graded stone aggregate as in padding concrete (levelling course) on roof complete all as specified and as directed by Engr-in-Charge.
Rendering 10 mm thick in CM (1:3) using water proofing compound as per manufacturer instructions as in roof padding and chajjas complete all as specified. Note : Water proofing compound will be measured and paid separately.
M&L for APP modified prefabricated five layer water proofing membrane minimum 3mm thick and weighing not less than3.6 kg/Sqm, reinforced with non woven polystester matt black finished (wt not less than150 gms/Sqm) over combatible primer at 0.40 Ltr/Sqm and torch applications of membrane with minimum 10cm side over lap and 15cm end laps and applying solar reflective bituminous aluminium paint @ 0.10 kg / sqm complete all as specified and as directed by Engineer-in-Charge.
Supply only integral water proofing compound complete all as apecified
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing srviceable tiles to store and rubbish off the premises complete all as apecified
M&L Anti-skid / Non skid ceramic coloured tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as directed
M&L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified.
M&L for 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes.
M&L glazed ceramic coloured tiles 450x 300x 6 to 7mm thick on vertical surfaces such as dados, wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match on vertical surfaces.
M&L Rendering 10 mm thick in CM (1:4) finished rought to receive wall tiles.
M&L for 20mm thick Granite (of any type) tiles machine cut, bedded and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and rounding edges, over 15 mm thick screed bed or bedding layer of mortar in cement mortar 1:6 for lying floor finishes complete all as directed and polishing complete
Demolition of brick work or stone masonry built in cement mortar including pillar etc. complete all as apecified
M&L for brickwork with fly ash modular bricks straight or curved on plan exc. 6m mean radius built in CM 1:6 complete all as specified
M&L Brick work with Fly ash modular bricks straight or curved on plan to any radius in half brick thick walls built in cm 1:4 complete all as apecified
Taking down plastering in cement mortar on brick or stone wall/ ceilings etc including racking out joints hacking for key scrubbing down with water etc.complete all as apecified
M&L for rendering 10mm thick cement plaster 1:6, incl finishing even and smooth without using with out extra cement on internal faces.
M&L for rendering 15mm thick in two coat 10 mm thick in cement plaster 1:6 and 5mm thick in cement plaster 1:4 mixed with integral water proofing compound as per manufacturer instruction,on fair faces of brick work or concrete surfaces finish even and smooth without using extra cement all as specified and as directed ( water proofing compound taken separately)
M&L for cement plaster 1:3, 5 mm thick incl finishing even and smooth without using extra cement on ceiling.
M&L for rendering 10mm thick in two layers on fair faces of brick work, chajja, facia,slabs etc in CM 1:3 finished even and smooth without using extra cement complete all as apecified
M&L for applying two coats of OBD over two coat of wall care putty over a coat of alkali resistant primer including preparing the new plastered wall surfaces complete all as directed
M&L for complete removal of existing surfaces on walls and applying two coats of oil bound distemper over two coat of wall care putty over a coat of alkali resisitant primer complete all as specified and directed.
M&L for three coats of white wash to ceiling surfaces including preparation of new surfaces complete all as specified
M&L for preparation of old surface of ceilings and applying one coat of white wash complete all as specified and directed.
M&L for preparation of new surfaces of walls etc, and applying two coats of exterior weather proof paint over one coat of external primer complete all as directed by Enginneer-In-Charge.
M&L for complete removal of existing treatment of walls and cornices and finishing walls with Acrylic Smooth exterior paint of required shade (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thick, including removing rubbish off the premises complete all as apecified
M&L for PCC (1:3:6) type C2 using 40 mm graded aggregate as in plinth protection/ Paths of 75mm thick. Finishing cement concrete surface even and smooth without using extra cement complete all as specified
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for complete all as specified.
M&L for formwork to rough finished flat surface of concrete soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping)
M&L for RCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) Slabs supported on walls,beams and columns in floors,roofs, landings, balconies,canopies, deck slabs and in shelves and the like complete all as specified
M&L for Mild steel TMT bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9 mm dia or securing with clips all as specified.
M&L for precast cement concrete 1:2:4, type B1 (using 20 mm graded stone aggregate), as in man holes cover slabs etc including necessary form work and set in CM 1:6, complete all as specified and as directed. Note:- Reinforcement will be measured and paid seperately
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) not exceeding 1.5 Sqm each complete all as apecified
Taking down chowkats or frames with shutters (without taking off shutter from the frames ) exceeding 1.5 Sqm each but n.exc. 4 sqm each complete all as apecified
S & F Anodised aluminium frame (Powder Coated) for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
M&L Anodised aluminium door shutters (Powder Coated), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Supply and Fixing powder coated anodised aluminium window and ventilator shutters without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified
S&F 12mmthickness toughened glass factory made frosted with MCEME logo embedded as in doors /wall partion including providing and fixing of top and bottom pivot and spring type fixing arrangement & necessary holes & making good & required hinges ,SS 304 grade handles , door/floorspring etc and including all necessary fittings complete allas specified and as directed.
Hacking out old broken glass (any thickness size/ quality description) from metal frame including punching or drilling out old glazing pin/spring clips and providing and fixing new one complete all as specified.
S &F of Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each panel of thickness 5.5 mm.
S &F Prelaminated particle board of thickness 18/19 mm, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to Aluminium frame.
S&F Windows/ ventilators (NCL ECO – 4000 Series Windows (Double Rebate Windows) or equivalent) fabricated from roll framed sections made of galvanized steel colour coated/ powder coated (Base steel as per IS 513 “D” quality galvanized as per IS 277 with zinc of 120 gms/Sqr. Mtr.) with total coated thickness of 0.58mm.Sections for Frame should be of 72mm x 55mm, Section for Mullion should be of 72mm x 50mm, Section for Shutter Frame should be of 47mm x 20mm, Section for Fixed Glass Bead should be of 12mm x 12mm, and Section for Fly Mesh should be of 40mm x 20mm Section for Frame Glazed Shutters and Mesh Shutters should be cut to length and miter joined with Polypropylene Corner Brackets, Mullion Section should be joined with Frame/Mullion using Mullion Cap Ethyl Propylene Damien Monomer (EPDM) Gasket should be used all around glass in shutter and Fixed Glass. Spoon Section should be used around Fly mesh to fix Mesh in Mesh Shutter including SS Pivot Hinges – 1 set, Seccolor Handle & Seccolor Stay and 4MM Plain Float Glass and Stainless Steel 32 gauge Fly mesh of 25 holes per SqCM and powder coated Grill made of 10mm sq. MS Bars welded at 150mm c/c, 6mm x 12mm MS flat and fixed to window frame with screws complete all as directed MAKE: NCL
M&L Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M S Square tube, supplying and fixing in opening as per manufacturers instructions all as directed complete all as specified
Factory made solid panel laminated PVC door shutter 30mm thick (style) consisting of frame made out M.S tube for top & bottom rails. M.S Frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail : Panelling of plain colour PVC sheet to be fitted in the M.S frame welded/scaled the stiles & rails with suitalble PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specifications & drawing complete all as specified
S&F 100 mm long butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed complete all as specified
S/F 150mm size aluminium anodised handles, fabricated type complete all as specified
S/F 150mm long aluminium anodised barrel tower bolt of extruded section complete all as specified
S&F 250 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified
S&F Solar control film 50 micron reflective type (gareware sun control or equivalent)
S & F door closer hydraulically regulated of Aluminium(die cast body), designation No.3 universal type suitable for door shutters of 851 to 1200 mm in width and of weight between 61 to 80 kg complete all as specified and as directed.
S & F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, overall length 150 mm fixed in floor complete all as specified and as directed .
S & F Aluminium Mortice lock, vertical type, size 100 mm, long 4 levers with handles complete all as specified and directed.
S & F Aluminium Mortice lock, vertical type, size 65mm, long 4 levers with handles complete all as specified and directed.
S & F Continuous (piano) hinges, with width of flam 30 mm mild steel, bright finish or electrogalvanised complete all as specified and directed
S & F 40mm dia, cupboard knobs fixed with nut, screw and washer of brass, polished all as specified and as directed.
S&F Harrison rails, mild steel, chromium plated with fixing brackets, stops, rollers etc
S&F 4mm thick figured glass pin head type and glazing with oil putty in square n. exc. 0.50 Sqm in each pane.
S&F Corner glass shelf with railing of Make Jaguar Cat No: ACN1173 complete all as spd and directed. Make : Jaguar Cat no:CAN-1173 or Its equivalent
S & F in repair Wall hung WC with UF soft close seat cover hinges Accessories ,Set Size 385x5695x385 mm withP or S trap with concealed flushing cistern Concealo Neo (80mm) size 460X 450X 80mm with all connected items complete Make: Jaguar Cat No:Hindware Cat No.92559 OR its equivalent
S&F in repair counter top basin of size 63 x 50 cms of complete as directed by Engr-in-Charge. Make: Hindware Cat No.10045 or its equivalent.
S&F towel rail 600 mm long with lower hanger QUEENS complete as directed by Engr-in-Charge. Make: Hindware Cat No.F-580012 or its equivalent
S&F in repair Soap dish complete as directed by Engr-in-Charge. Make: Jaguar Cat part No ACN 1131N or its equivalent
S&F angular stop cock with flange complete as directed by Engr-in-Charge. Make: Hindware Cat No.F-200005 or its equivalent
S&F health faucet (ABS with 8 mm dia, 1.2 m long flexible tube and wall hook (allied) complete all as directed by Engr-in-Charge. Make: Jaguar Cat part No 565 or its equivalent
S&F toilet paper holdercomplete as directed by Engr-in-Charge. Make: Jaguar Cat part No AQN 7753 or its equivalent
S&F two way bib cock with wall flange complete as directed by Engr-in-Charge. Make: Jaguar Cat part No QQT-7041 or its equivalent
S&F in central hole basin mixer with regular spout with popup waste system with 450mm long braided hoses (QUEENS) complete as directed by Engr-in-Charge. Make: Jaguar Cat part No QQT-7169B or its equivalent
S&F looking mirror of size 1.50 m long and 0.90 mtr wide with fancy glass with decorative beading complete all as directed.
S&F 15 mm dia stop/ angle valve, chromium plated fancy type, cast copper alloy with capstain/ fancy type handle , screwed down , screwed both ends for iron pipe or for brass ferrule with wall flange. Make: Jaquar, cat part No- CON-059KN
S&F in repair Vitreous China sensor Type Urinal with suitable connection accessories white/ ivory colour & urinal vitrous portion complete all as directed. Make : Jaguar, Hindware, Cera
S&F in repairs for low density polythelyne pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB etc. 32mm bore complete all as specified
Taking up or down steel tubing & connections, 15 mm dia complete all as apecified
Taking up or down steel tubing & connections, 20 mm dia complete all asapecified
S & F 15mm dia. Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe all as specified and directed.
S & F 20mm dia. Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipe
Cutting chases ,pinning in making good to facing where required of brick walls and pointed in cement mortar 1:3 for concealed water tubing etc cutting not exc 10 cm girth.
Dismantling /Demolition and breaking of old water tanks(PVC ) of exc 500 and n exc1000 Ltrs capacity complete all as specified
S&F 1000 ltrs capacity rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I complete all as specified
S & F Gun metal globe or gate valves of 20 mm dia with iron wheel head screwed both ends for iron pipe and fixed in repair complete all as specified
S&F 20 mm bore dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (min weight 210gms) complete all as specified
S&F Stainless steel sink with draining board, made out of 1.00mm thick sheet for kitchen or laboratory with plug, waste coupling CP brass , washers waste pipe, cast iron cantilever brackets, connecting union overall size 915mm X 460mm with bowl size 410mm X 330mm X 160mm complete all as specified
S&F in repairs110 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and laid in trenches and under floor etc incl taking down old pipes complete all as specified
S&F in repairs 75 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls and laid in treanches and under floors etc incl taking down old pipes complete all as specified
S&F 110mm PVC (SWR) bends any radius complete all as specified
S&F 75 mm PVC (SWR) bends any radius complete all as specified
S&F 110mm PVC (SWR) bends any radius but with access doors complete all as specified
S&F 75 mm PVC (SWR) bends any radius but with access doors complete all as specified
S&F PVC (SWR) floor trap, plain with grating including jointing with solvent to waste pipe fixed in cement concrete type B-1 (1:2:4), 75 mm dia outlet complete all as specified
S&F PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement complete all as specified
S&F 110 mm PVC (SWR) vent cowl complete all as specified
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finished, and reforming benching as required for 150mm dia pipe complete all as specified and as directed.
Demolition of precast concrete block masonry, built in cement mortar incl all quoins, arches, pillars, etc. but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specificed and as directed .
Demoltion of cement Concrete of any description and in any position not otherwise specifically provided, complete all as specificed and directed by Engineer-in-Charge.
M&L for Cement concrete type D2 1:4:8 ( 40 mm graded aggregate) in foundations, filling and mass concrete complete all as specified.
M&L cement type C2 1:3:6, using 20mm aggregate in surface channel and drains etc, complete all as specificed and directed by Engineer-in-Charge.
M&L for precast cement concrete Type C1, 1:3:6 (20 mm graded aggr) solid block masonry exc 10 cm in width and set in CM 1:6, complete all as specificed and directed by Engineer-in-Charge.
M & L plain cement concrete 1:3:6 type C1 using 20mm graded aggregate in coping complete all as specified.
M&L Rendering 15mm thick in CM 1:4 on brick work or concrete surface is to be finished even and smooth (without using extra cement)
Excavation in Post holes ( or similar holes ) in hard dense soil, each not exc 0.5 cum, getting out, and removing excavated soil to a distance n.exc 50m.
M&L treating surfaces of ends of post etc area n.exc 0.1 sq.m each tretad with tar or coal tar black paint.
M&L providing cement concrete 1:2:4 in foundations, including raft footings, foundation beams and mass concrete.Type B-1,(using 20 mm graded aggregate), all as directed by Engr-in-charge.
M&L for two coat of synthetic enamel paint over a coat zinc chrome primer, including preparing new steel surfaces any description, over 10 cm width or grith,not otherwise described.
S&F Steel work in tubular trusses / rectangular or square, Hollow mild steel sections for structural use, including special shaped washer etc. complete using ERW or induction butt welded tubes confirming to I.S.1161-1979 grade St-240, and Painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractor's workshop before fabrication
S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410 -W (Gde-E- 250) quality-A all as specified and directed.
S&F Pre-painted galvatume aluminum zinc coating GI based corrugated steel sheeting, 0.50 mm thick, of an colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws or or fixed with 'L' or 'J' type or cranked hooks bolts in liew of screw all as specified by Engr-in-charge.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/cladding to wall, ridge fixed with self tapping screws as specified
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / Hylam sheet/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Material and labour for point wiring with single core PVC insulated unsheathed 1100 volt grade cable with multistranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including non metallic rigid PVC conduit medium duty ISI marked of suitable dia conduit wiring including Tee, Junction boxes and provision of modular terminal boxes and covered with modular cover plate with frame of suitable size including suitable screws with washer for mounting modular switch, modular sockets and modular regulators and drawing continuous earth wire with and including PVC insulated unsheathed 1100 Volts grade cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) and connected to common earth dolly complete all as specified & as directed for One light point controlled by one, one way Modular switch 5 amps, SP
All as per item No. 112 above but for One Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator
All as per item No. 112 above but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per item No. 112 above but for One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No. 112 above but using 4 Sqmm single core copper conductor cable multistranded PVC insulated unsheathed 1100 volts grade for 3 pin 15 Amps switch socket combination point including running 4 Sqmm copper conductor PVC wire as earth continuity conductor on independant board.
Supply and fixing of Modular Switch , 1 module, 6 Amps capacity 230 volts complete all as specified.
Supply and fixing of Modular Switch , 1 module, 16 Amps capacity 230 volts complete all as specified.
Supply and fixing of Modular socket outlet 6 Amps 2 /3 pin 2 module complete all as specified.
Supply and fixing of Modular socket outlet 6/16 Amps 2 /3 pin 2 module complete all as specified.
Supply and fixing of ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
Supply and lay on wall/in ground/on pole ISI marked XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 1100 volts laid in trenches, floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified of size 50 Sqmm , 3.5 core all as specified and directed. ( Main panel to VTPN DB )
Material and labour for concealed Submain wiring with 4 runs of single core 10 sqmm and 2 runs of single core 6 sqmm earth wire PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 32 mm dia including two run of single core 10 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed.Note:-Four runs of cable, two run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From VTPN DB to TPN)
Material and labour for concealed Sub main wiring with 2 runs of 6 sqmm single core, 1 run 4 sqmm multistranded PVC insulated unsheathed cable 1100 volts grade with copper conductor, drawn in and including concealed rigid PVC conduit of 25mm dia, conduit fittings and accessories concealed in wall/roof/floor with one run of 6 sqmm PVC insulated unsheathed copper conductor cable as earth continuity conductor and connecting to common earth dully all as specified and directed.Note: 3 runs wires and one unit lenght of conduit shall be measured as one unit length.(From TPN DB to 1 phase metal clad Socket and SPN Dbs )
Material and labour for concealed Submain wiring with 2 runs of single core 4 sqmm and 1 run of 2.5 sqmm earth PVC insulated unsheathed multistranded 1100 volts grade with copper conductor drawn through and including non-metalic rigid PVC conduit and conduit accessories of medium grade not less than 25 mm dia including one run of single core 4 sqmm PVC insulated unsheathed multistranded 1100 volts grade with copper conductor cable as earth continuty conductor along with the wiring and connected from Panel/DB to DB/main board including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified and as directed. Note:-Two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured as one unit length. (From TPN DB to 15A Power sockets)
S & in replace of Vertical type MCCB TPN DB 4 way double door suitable for MCCB 100 Amps made out of CRCA sheet housing with powder coating complete all as specified and directed.
Supply and replace MCCB 4P, 415V,16KA, 125 amps suitable for Vertical MCCB DB all as specified and directed .
Supply and replace MCB double door TPN DB 6 way with 415V, 200 Amps busbar made including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
Supply and fix in MCB TPN 40 Amps 415 volts for fixing on MCB DB.
Supply and replace MCB double door DB SPN 8 way with 200 Amps busbar including removing the existing unserviceable one and making good the distrubed surface to match with the existing surface.
Supply and fix in MCB SPN 40 Amps 240 volts for fixing on MCB DB.
Supply and fix in MCB SP 6 to 40 Amps 240 volts for fixing on MCB DB.
Supply and fix in MCB SP 63 Amps 240 volts for fixing on MCB DB.
Supply and fix in MCB TP 40 Amps 415 volts for fixing on MCB DB.
S&F SPN encloser with a two pin and earth pin and socket complete with one SP MCB 20Amps all as specified and directed.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete.
Supply and Fixing of LED luminaire 600mm X 600mm 35/36W ,220V, AC recessed type with high efficiiency PMMA diffuser soft glare free light complete with drivers ,holders LED lamp suitable for roof ceiling connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fixing LED wall mounted batten light fitting with polycarbonate housing and integrated electronic driver 1x 20W, 220V, AC connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed .
Supply and fix LED energy efficient security light fitting of capacity of 40 W including suitable dia GI pipe bracket for fixing the light on wall all as specified and directed. NOTE : GI bracket, clamp, nut and bolt etc will be measured in separate item.
Supply and fixing galvanised iron tube bracket of 40 mm dia light grade and 1.2 m length for fixing bldg security light, with all fixing arrangement including necessary clamp, nut and bolts etc as required size all as specified and directed
S & F Exhaust fan pvc body , 300 mm sweep , single phase ,50 HZ , with louver and connecting up with and incluiding provision of PVC insulated copper flexible cord of size 23/0.019, 3 core from ceiling rose to connection of exhaust fan and including material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface completed all as specified. Note : cost for material and labour for making of hole to the wall of suitable size for fixing of exhaust fan and making good the disturbed surface will be measured and paid in seperate item.
Disconnecting and removing fan of any sweep any height from electrical connection bringing down, dismantling, cleaning internally and externally thoroughly examine and replacement of split pins/ cotter pins and check nuts etc overhauling, lubricating , reassembling, refixing in original position with new down rod and clamp complete all as specified.
Rewinding of burnt ceiling fan of 1200 / 1400mm sweep of any make and model with supper enameled copper wire of suitable size and using insulating material of good quality, varnishing complete all as specified and directed by Engineer -in-charge.
Supply only Sealed ball bearing suitable for ceiling fan of any size(set of two)
Supply only Rotar shaft suitable for ceiling fan of any size
Supply only Rubber bushes with MS clamp,bolt and nut suitable for ceiling fan of any size.
Supply only Fan condensor 2.5 mfd suitable for ceiling fan of any size.
Materials and Labour for one coat of spray painting, super glossy to fan body including blades with white colour, after removing of loose paint, rust dust and oily particle by scraping , complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 mtr width and not exc 1.5 mtr in depth and getting out in hard /dense soil for laying / repairing of LT cable / GI pipe.
Supply, spread river sand of approval in cable trenches providing for cable cushioning as directed. NOTE :- Punned thickness of sand only will be measured and paid.
Removal of surplus soil to a distance not exc 50 mtrs away and depositing where directed at a level not exc 1.5 mtr above the starting point.
Returning , filling incl spreading levelling watering and well ramming in layers not exc 25 cm thick.
Supply and lay PCC cable covers for LT cable protection, Class LV, Type 1 of size 250x150x40mm
Supply and fixing medium grade GI tubing of 50 mm dia for XLPE cable protection complete all as specified and as directed
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth wire 4 mm dia drawn through and including GI protection pipe of light grade 15 mm bore by means of bolts, nuts, checknuts and washers all as shown in Electrical Plate No.3 of SSR Part-I and connected to main switch board including excavation and earth work, PCC chamber in 1:3:6, RCC Cover in 1:2:4 type B-1 reinforced with 8 mm dia MS bars at 10 cm c/c, 20 mm dia medium grade GI pipe with funnel and wire mesh complete and watering arrangement all as specified. (Note: GI pipe 15mm dia, GI wire 4mm dia upto 7.5m deemed to be included in quoted rate.)
Sri venkateswara Electricals (BID ID -3134054)
Sri Associates (BID ID -3134307)
SAI RUPA CONSTRUCTIONS (BID ID -3133676)
B AND H CONSTRUCTIONS (BID ID -3134118)
K LAKSHMAN SINGH AND CO (BID ID -3133692)
Vara Enterprises (BID ID -3134321)
KIRAN CONSTRUCTIONS (BID ID -3133978)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .