YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AUTHORITY
Construction of 33/11kv Subsatation (Ess No-01) in Sector-24A yeida
2026_YEIDA_1139773_9
YEA/OSD(M)/2026/394 DT-16/04/2026
Open Tender
Electrical Works
Fixed-rate
365 days
YAMUNA EXPRESSWAY INDUSTRIAL DEVELOPMENT AUTHORITY
REFER TENDER DOC
5 documents required · 5 mandatory
₹6,770
₹11.3 L
6 Aug 2026
22 Apr 2026
6 May 2026
22 Apr 2026
4 May 2026
22 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | (33kV HT PANELS)Supply, Installaton, Testing & Commissioning of 33 KV ,Indoor type 6 panel board Vacuum circuit breaker (With 1 No. Incomer 1250 Amps, 2 No. Outgoing 1250 Amp, 2 No. Tie Feeder 1250 Amp & 1 No. Bus Coupler 1250 Amp), 3 phase, 31.5 KA for 1 sec. , HT switch gear with all necessary protection, metering and other accessories as required. Analysis of Rate YEIDASOR- 73 | 1 | Nos. | - | - |
| - | Supply , Installaton, Testing & Commissioning of 33KV , Indoor type 2 panel board Bus PT, 3 phase, 31.5 KA for 1 sec with all necessary protection, metering and other accessories as required. Analysis of Rate YEIDASOR- 71 | 1 | Nos. | - | - |
| - | Supply, Installation, testing & commissioning of out door type 10 MVA Power Transformer with on load tap changer as per ISI specification including loading, unloading, local carriage & erection of the same on plinth & making all necessary connection etc. Complete in all respects as per specification (Make ABB/ Crompton/ Schinider). Cable termination box with disconnecting facility for 33 KV XLPE cable at 33 KV side. Cable termination box with disconnecting facility for 11 KV XLPE cable at 11 KV side.On load tap changer+/- [email protected]%, Bi directional roller, Conservator with drain valve, Earthing ferminals, Double diaphragm explosion vent, Radiator with top & bottom shut off valve, First filling of oil including make up fill, Silica gel breather with oil seal, Rating and diagram plate, Air Release plug,Buchholz relay with shut off valve,Winding temperature indicator (WTI), Oil temperature indicator (OTI), Megenatic oil level guage, Pressure relief device, Marshalling box. No load losses-7Kw, load losses 50KW, Toleronce as per I.S. code Analysis of Rate YEIDASOR- 75 | 2 | Nos. | - | - |
| - | Supply Installaton Testing & Commissioning of 11 kV, Indoor type 12 panel board Vacuum circuit breaker (2 No. Incomer 1250 Amps, 1 No. bus coupler 1250 Amps and 9 Nos.630Amp Outgoing) 11 KV, 3 phase, 25 KA for 1 sec. HT switch gear VCB breaker with all necessary protection, metering and other accessories as required. Analysis of Rate YEIDASOR-72 | 1 | No. | - | - |
| - | Supply, Installaton, Testing & Commissioning of 11KV Indoor type 2panel board Bus PT, 3 phase, 25 KA for 1 sec with all necessary protection, metering and other accessories as required. Analysis of Rate YEIDASOR- 70 | 1 | Nos. | - | - |
| - | Supplying, assembling, installation, commissioning of Sealed maintenance free (SMF) 110V D.C., 200 AH batteries. The batteries shall rest on treated wooden planks fabricated from MS angle and free standing floor mounted rack with acid resistant finish and complete with series connecting electrical leads and charging of batteries. The batteries shall be accompanied with tester. This shall have incoming leads as well as outgoing leads and of suitable battery charger for 8 hrs charge of 200AH battery charger enclosed in sheet metal with fan on top and it should automatically charge the batteries With booster and trickle charge. Charger shall be complete with incoming & outgoing leads and D.C. Distribution board will have one set of 63 amps MCB as incomer and 10 Nos. of suitable rated MCB (as per coil rating of VCB) on outgoing side enclosed in metal sheet enclosure of 2mm thick CRCA sheet steel dully painted anti-corresion paint. The unit will be complete with bus bars, accessories, links, terminal strip, clamps etc along with cables up to incoming & outgoing to VCB panels.Analysis of Rate YEIDASOR- 69 | 1 | No. | - | - |
| - | Supply, delivery, laying, testing & commissioning of 33KV (E), XLPE cable having compacted circular staranded aluminium conductor, conductor screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semin conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 33 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I. Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job. (CCI , Fort Gloster, Asian , Universal, Nicco , ICL , Diamond, Havells, KEI make. Analysis of Rate 33kV, 3C X 400 sq. mm. (from 33kV HT Panel to 33/11kV Power transformer). Analysis of Rate YEIDASOR- 03 | 330 | Mtr. | - | - |
| - | Supply, delivery, laying, testing & commissioning of 11KV (E), XLPE cable having compacted circular staranded aluminium conductor, conductor screening of extruded semi conducting compound, cross linked polythylane (XLPE), insulation screening of the extruded semin conducting compound followed by copper tape, cores laid up, taped PVC inner sheath, single layer of steel strip armouring, overall PVC outer sheath conforming to IS: 7098 (Part-amendments) for following mentioned sizes. It should be operational at 33 KV, 50 Hz. AC system in ground at a depth of 1200 mm below ground level over a cushion of 75 mm thick sand alround and protected with bricks on sides and top on surface the cable run shall be fixed on M.S. clamps etc of suitable size or as directed by the E/I. Complete in all respect. The price are inclusive of all earth work such as digging, back filling, supply & spreading of good earth all around the cable, supply & providing cable identification markers. The installation should be complete in all respects and as per requirement of the job. (CCI , Fort Gloster, Asian , Universal, Nicco , ICL , Diamond, Havells, KEI make. Analysis of Rate 11kV, 3C X 300 sq. mm. (From 33/11 Power Transformer to 11 KV HT Panles). Analysis of Rate YEIDASOR- 02 | 300 | Mtr. | - | - |
| - | Supply, Delivery, Installation, Testing & Commissioning of 33KV, Indoor type cable termination kit complete in all respects as required for proper completion of work. (make Raychem, CCI, Frontec) 33kV, 3C X 400 sq. mm., XLPE insulated, Aluminum conductor E grade, strip armoured cable. Analysis of Rate YEIDASOR- 09 | 8 | Nos. | - | - |
| - | Supply, Delivery, Installation, Testing & Commissioning of 33KV, Indoor type cable termination kit complete in all respects as required for proper completion of work. (make Raychem, CCI, Frontec) 11kV, 3C X 300 sq. mm. ,XLPE insulated, Aluminum conductor E grade, strip armoured cable. Analysis of Rate YEIDASOR- 04 | 8 | Nos. | - | - |
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.71 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.32 MB
BOQ_2128846.xls
BOQ • 0.46 MB
9.pdf
Tender Documents • 1.58 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .