Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹93,142Accepted-AOC | ₹93,142 | L1 | Accepted-AOC L1 Bidder |
| 2 | L1₹2.9 LAccepted-AOC | ₹2.9 L | L1 | Accepted-AOC L1 Bidder |
| 3 | L1₹3.2 LAccepted-AOC 107 CHOPRA COMPLEX COMMUNITY CENTER PREET VIHAR PREET VIHAR EAST DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | ₹3.2 L | L1 | Accepted-AOC L1 Bidder |
| 4 | L1₹4.1 LAccepted-AOC KHASRA NO 605 612 615 618 PILKHUWA DHOLANA ROAD VILLAGE KHERA PILKHUWA PILKHUWA HAPUR UTTAR PRADESH 245304 | HAPUR | UTTAR PRADESH | 245304 | ₹4.1 L | L1 | Accepted-AOC L1 Bidder |
| 5 | L2Rejected-Finance B 12 BULANDSHAHAR ROAD GHAZIABAD NEAR RTO OFFICE GHAZIABAD UTTAR PRADESH 201001 | GHAZIABAD | UTTAR PRADESH | 201001 | - | L2 | Rejected-Finance L2 Bidder |
Tender Value
Refer Docs
Closing Date
29 Dec 2022, 3:00 pmClosed
Mr. Nilesh Sathe
thyssenKrupp Industrial Solutions (India) Private Limited (Formerly Uhde India Private Limited) Uhde House, L B S Marg, Vikhroli (W), Mumbai - 400083, India
SUPPLY OF FLANGE-CARBON STEEL FOR P25 PROJECT AT IOCL PANIPAT REFINERY
2022_REFHQ_160399_1
6745-PPM-000-CA-PI43
Limited
Mechanical - Piping, materials, flanges, valves, seals
Supply
120 days
IOCL Panipat Refinery
Please refer Tender documents.
6 documents required · 6 mandatory
Exempted
22 Jan 2025
15 Dec 2022
30 Dec 2022
15 Dec 2022
29 Dec 2022
22 Dec 2022
SUPPLY OF FLANGE- CARBON STEEL
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 150,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH 160,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
BF,CS, 150,0, AWWA C207 CL.D, FF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
BF,CS (NACE), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
BF,CS (NACE), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
BF,CS (NACE), 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
STEEL FLG,CS, 150,0, AWWA C207 CL.D, FF, HUB TYPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
STEEL FLG,CS, 150,0, AWWA C207 CL.D, FF, HUB TYPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
STEEL FLG,CS, 150,0, AWWA C207 CL.D, FF, HUB TYPE, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 150,0, B16.5, BW ENDS,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS, 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
WN FLG,CS (NACE), 300,0, B16.5, BW ENDS,SCH STD,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.NACE REQ. ACC. TO NACE MR-0103, AND DOC. 6745-PIP-000-EC-0005
SO FLG,CS, 150,0, B16.5, RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SW FLG,CS, 150,0, B16.5, SW END,SCH XS,RF, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001
SUPPLY OF FLANGE- CARBON STEEL (EPOXY COATED)
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
WN FLG,CS,(INT EPOXY CTD), 150,0, B16.5, BW ENDS,SCH STD,RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
BF,CS,(INT EPOXY CTD), 150,0, B16.5, RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
BF,CS,(INT EPOXY CTD), 150,0, B16.5, RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
BF,CS,(INT EPOXY CTD), 150,0, B16.5, RF, FORGED, INTERNAL EPOXY COATED, FLANGE A105N, ADD. INFORMATION, 1.FOR GENERAL TECHNICAL REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0001, 2.FOR INTERNAL COATING REQUIREMENTS, REFER DOC. 6745-PIP-000-EC-0023
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .