Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance CB 288 RING ROAD NARAINA NEW DELHI NEW DELHI 28 | NEW DELHI | DELHI | 110028 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹88 L
Closing Date
6 Feb 2021, 2:00 pmClosed
Er. A.K. Chhibber
Office of the Deputy General Manager, JKPCC Ltd., Unit Electrical, Rail Head Complex Jammu.
SITC of 1000 kVA Servo AVR, LT panels, cables and minor leftover internal/ external electrification works at Additional Block of Dental Hospital, Jammu.
2021_PWDJK_114358_1
e-NIT No. 43/ELECT of 2020-21 Dt. 22-01-2021.
Open Tender
Electrical Works
Item Rate
90 days
JAMMU
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,000
Yes
Financial Controller, JKPCC Ltd.
Exempted
O/o General Manager, JKPCC Ltd., Jammu
15 Mar 2021
23 Jan 2021
6 Feb 2021
23 Jan 2021
6 Feb 2021
23 Jan 2021
28 Jan 2021
Amount
OUTGOINGS MCCB 400 Amps FP TMR with Breaking Capacity 36 KA (6 Nos) MCCB 250 Amps FP TMR with Breaking Capacity 36 KA (6 Nos) MCCB 100 Amps FP TMR with Breaking Capacity 36 KA (3 Nos) Microprocessor ACB 800 Amps FP EDO Type for AC plant with Breaking Capacity 50 KA (2 Nos) Microprocessor ACB 800 Amps FP EDO Type for DG Supply with Breaking Capacity 50 KA (1 Nos) On/Off/trip (15 Set) 30 A Capacitor Duty Contactor (10 Nos) 50 A Capacitor Duty Contactor (4 Nos) Capacitor 30 KVAR 440 V H.D (10Nos) Capacitor 50 KVAR 440 V H.D (04 Nos) Push Button (01 Sets) MAKE of Panel Body :-CPRI Approved IP-54 Powder Coated with 50 ka bus bar breaking capacity. ( Electric field/Jai Maa/Power Control/OR any other National Approved Brand. ) The manufacturer must have a valid Type Test of the Equipment from a Govt. approved Test House. Load Bearing Members to be made out of 2.0 mm CRCA Sheet. Partitions to be made out of 1.6 mm CRCA Sheet Gland Plates to be 3.0 mm Thick.
Supplying,Installation,Testing and Commissioning of Cubical Type Floor Distribution Panel Board Suitable for for dental chairs.(size 1' x1'x10") complete with powder coated and hingable locking unit. 8 module box with plate - 1 nos 10 Ampere switch - 4 Nos 10 Ampere socket- 4 Nos
Supply, laying and testing of under noted sizes of Aluminium conductor XLPE insulated PVC sheathed & sleeved armoured and overall PVC sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and as per specification laid direct in ground along with PVC pipe/glads etc.
Single core 630 sqmm Aluminium armoured cable
3.5 x 400 sq.mm
3.5 x 240 sq.mm
3.5 x 185 sq.mm
3.5 x 150 sq.mm
3.5 x 120 sq.mm
3.5 x 95 sq.mm
3.5 x 50 sq.mm
3.5 x 25 sq.mm
SITC of 13 metre MS Pole along with insulator , Aluminium paint,etc.
SITC of 100 Watt LED Street Light along with bracket .
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required.(For horizontal run)
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or on surface of wall for lightning conductor complete as required. (For vertical run)
Earthing with GI earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required.
Supply, Installation, Testing & Commissioning of 1000KVA Servo Voltage Stabilizer at Additional block of Dental Hospital,,Jammu. The unit shall be copper wound operational automatically as well as manually, naturally oil cooled type, operation servo controlled, 3 phase and designed for input voltage range of 300 volts to 460 volts and output voltage 415 ± 1% with frequency 50 Hz ± 3 % of AC supply. The rate of correction of voltage shall not be less than 8V per second between phase and neutral. The Unit shall have combination of 3 no separate phase units which shall have separate tanks for dimmers and buck boost transformers. The no-load current shall not be more than 5% of the rated output current. The Stabilizer shall be totally powder coated from outside to have aesthetic outlook and inside of tank should be zinc chromate painted. Panel should be screen- printed. The unit shall be housed in sheet steel case of suitable thickness having wheels with sturdy construction to withstand the rigorous shifting movement, repair works and handing .The unit shall be supplied with first filling of oil and shall be suitable for unbalanced input voltage and unbalanced output load and the Servo Voltage Stabilizer should be equiped with BYPASS bus bar facility. The manufacturer must have a valid Type Test of 1000 kVA or above Servo AVR from a Govt. approved Test House.
A G ELECTRICALS
Electro Tech Systems
Electromechanics Engineers And Contractors
COUNTRY CONSTRUCTION
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .