Loading…
Loading…
Tender Value
₹88.5 L
EMD Value
₹1.8 L
Closing Date
11 Sept 2026, 11:00 am
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
14 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees, N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar Nature of Work: Works of wiring/cabling or installation and commissioning of electrical items (other than on coaches) such as lights, fans, pumps, charging arrangements. earthing etc (with or without supply of items/equipment's) for 230 Volts, 1 phase or 415V, 3 phase system or higher voltages.
27 conditions · 3 needing a document upload
Uploading of Scanned copy of Statement of Bank details, PAN & GST.
Compliance with Public Procurement (Preference to Make inIndia) Policy: This tender complies with Public Procurement(Preference to Make in India), Order 2017-Revision dated19.07.2024 of Department of Promotion of Industry and InternalTrade, Ministry of Commerce and Industry, Govt. of India (hereinreferred to as PP-PIM), circulated vide Ministry of Railways(Railway Board)'s letter No.2020/RS(G)/779/2/Pt.1 (E3322671)dated 20.08.2024, and all its amendments. Only Class-I localsuppliers (as defined in PP-PIM) shall be eligible to bid for list ofitems specified in Ministry of Railways (Railway Board)'s letterno.2025/RS(G)/779/3 (E3488356) dated 02.05.2025. For otheritems, only Class-I and Class-II local suppliers are eligible to bid.At the time of bidding, each bidder is required to indicatepercentage of local content (as defined in PP- PIM) and provideself-certification that the item offered meets the local contentrequirement for "Class-I local supplier"/"Class-II local supplier",as the case may be. If this self-certification is not submitted, thebid will be summarily rejected. For contracts above Rs.10 crores,the provisions of Para 9(c) of PP-PIM shall be additionallyapplicable. For the purposes of this NIT, the "local content" (asdefined in PP-PIM) requirement to categorize a supplier as"Class-I local supplier" is minimum 50% and for "Class-II localsupplier" is minimum 20%. Also, the Margin of PurchasePreference (as defined in PP-PIM) is 20%. The procedure forpreference to Make in India shall be as specified in PP-PIM.Uploading of self-certificate for meeting the local contentrequirement for "Class-I local supplier"/"Class-II local supplier",as the case may be (proforma attached). Non- submission of thiscertificate will lead to summary rejection of bid. ( Click here to download Format)
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
PANP & S - Provision of General waiting room at PF-1, Toilet block at PF-2, Full length PF shelter at PF-1&2 at PANP & waiting room and parking development at S.
Y-E-29-2026-27-78~SWR
Y-E-29-2026-27-78
Open
Works - General
120 Days
Dharwad, Karnataka
₹0
₹1.8 L
20 Aug 2026
20 Aug 2026
28 Aug 2026
77 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 88,47,623.96 | ||
| — | 100.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Up to 35 sq. mm size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. | — | — | — | 25,300 | |
| — | 700.00 | — | — | ||
| Platform surface/concrete/Road cutting for excavation of cable trench 300 mm wide x 300 deep, re-fitting of soil and re-plastering of excavated trench with cement on the PF's to bring original shape. | — | — | — | 4,71,163 | |
| — | 2500.00 | — | — | ||
| Laying of 4 x 16- 35 Sq mm LTUG cable with aluminium conductor including end terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. | — | — | — | 24,075 | |
| — | 950.00 | — | — | ||
| Supply of HDPE pipe of dia 75 mm grade PE-100 with pressure of PN 6 for safety of cables. | — | — | — | 1,33,000 | |
| — | 950.00 | — | — | ||
| Laying of HDPE Pipe of dia 75 mm grade PE-100 with pressure of PN 6 for safety of cables and all the ends sealing with bituminous compound. | — | — | — | 13,765.5 | |
| — | 124.00 | — | — | ||
| Supply and Fixing of GI pipe 'B' class of dia 50 mm. for cable rising & protection including clamping, fixing arrangements and sealing with bituminous compound. | — | — | — | 1,07,632 | |
| — | 60.00 | — | — | ||
| Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface / recess / concealed, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. / casing & capping as per site requirement. | — | — | — | 32,700 | |
| — | 36.00 | — | — | ||
| Supplying and fixing suitable size GI / PVC box with modular plate and cover in front on surface / recess / concealed, including providing and fixing 6 pin 15/16/20/25 A modular socket outlet and 15/16/20/25 A modular switch, connections etc. / cassing & capping as per site requirement. | — | — | — | 23,724 | |
| — | 16.00 | — | — | ||
| Supply, fixing and commissioning of 200 mm size BLDC Ventilating fan including all other required accessories complete. | — | — | — | 28,025.76 | |
| — | 96.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) motor ceiling fans with maximum power of 28 W 5 star rated with remote 1200 mm size as per specifications. | — | — | — | 2,76,672 | |
| — | 380.00 | — | — | ||
| Supply, fixing, testing and commissioning of 18 - 22 watt 6500k batten 4 feet approximate length LED lighting fixture as per specification SWR/LED LIGHT FITTING(Indoor/outdoor) /001-2016 effective from 18.04.2016 or latest. Including all other required accessories complete. | — | — | — | 2,58,780 | |
| — | 30.00 | — | — | ||
| Supply of 10 watt 6500k batten 2 feet approximate length LED lighting fixture as per specification SWR/LED LIGHT FITTING (Indoor/outdoor)/001-2016 effective from 18.04.2016 or latest. | — | — | — | 4,705.5 | |
| — | 700.00 | — | — | ||
| Wiring for circuit/ sub main wiring along with earth wire with the 2 X 4 sq. mm + 1 X 4 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. | — | — | — | 2,61,100 | |
| — | 600.00 | — | — | ||
| Wiring for circuit/ sub main wiring along with earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire sizes of FRLSH / HFFR PVC insulated copper conductor, single core cable in surface / concealed medium class PVC conduit / casing & capping as required at site. | — | — | — | 1,86,600 | |
| — | 577.00 | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable in surface / Concealed medium class PVC conduit / Casing & capping, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLSH / HFFR PVC insulated copper conductor single core cable etc. as required. (Group - A). | — | — | — | 6,86,053 | |
| — | 12.00 | — | — | ||
| L.T. Earthing arrangements for hard soil using 50 mm C-Class GI Pipe- 2.7 Mtr length, soil treatment by spreading of 25 kgs each of salt and charcoal, duly painting earth pit with black paint and stencilling of earth resistance value with date, including supply and laying of 6 SWG G.I. wire and other hardware to connect equipment at site complete. | — | — | — | 62,364 | |
| — | 6.00 | — | — | ||
| Supply, fixing and commissioning of MCB Distribution board 8 way with transparent cover providing DP MCB-16 Amp-1 No, SP MCB-6 A- 2 Nos & SP MCB-2 A-3 Nos and supply indicator light MCB type-1 No.(All MCB are of Curve-C). | — | — | — | 31,062 | |
| — | 10.00 | — | — | ||
| Design, supply and installation of mobile charging unit made out of MS sheet CRCA 1.2 mm Thick, powder coated, IP 20 of dimensions 360mmx260mmx 100mm with 4 Nos of 6 A sockets and 2 Nos 1 Module USB charging units having 6 A switch for individual sockets and 6A MCB in the incoming with mobile holding tray of size 250mm x 150mm and 4 Nos mobile holding pockets mounted on sides(detachable) as per drawing attached including IR logo, stickering, fixing arrangements on the wall/steel girder as per site condition. Sample to be supplied for approval. | — | — | — | 66,720 | |
| — | 2.00 | — | — | ||
| Liason charges for correspondence with EB authorities for availing new connection, EIG charges. | — | — | — | 13,648.54 | |
| — | 50.00 | — | — | ||
| Dismantling of Existing light posts and electrical fittings in platform/approach road/street light/circulating area and other locations and handing over to concerned SSE in-charge with clear acknowledgement. | — | — | — | 23,414 | |
| — | 1.00 | — | — | ||
| Design, fabrication, supply, installation and commissioning of outdoor LT pane lmade out of 16 SWG CRCA sheet steel, vermin and dust proof with Siemens gray powder coated paint comprising of 200 A FP On load COS-1 No, 200 A FP MCCB with adjustable thermal settings, 25 KA Breaking capacity - 1 Nos as incomer,125A FP MCCB with adjustable thermal settings, 25 KA Breaking capacity- 1Nos, 63 A FP MCCB with adjustable thermal settings, 18 KA Breaking capacity- 4 Nos, 32 A DP MCB -3 Nos, 200 A earth fault relay for incomer MCCB - 1 No including CT for operating earth fault relay a shunt trip to be used including all auxiliary accessories, RYB indication lamp (LED type) -1 Set, Digital multi data meter with suitable Copper Bus bars, cable alleys, locking arrangement, concrete structure for mounting & amp; all auxiliary accessories as per site condition. | — | — | — | 1,78,287.36 | |
| — | 2.00 | — | — | ||
| Supply and provision of Switch board to control all-night and part-night light circuits in platform comprising of 1 No. of 32 Amp DP MCB and 4 Nos of 16 Amp. SPN MCBs, surface mounting type sheet steel enclosure fitted with bus bar, in channel, neutral link and incoming contact | — | — | — | 7,774.8 | |
| — | 100.00 | — | — | ||
| Supply and laying of HDPE pipe of dia 110 mm grade PE-100 with pressure of PN 8 for safety of cables including all the ends should be sealing with bituminous compound. | — | — | — | 44,069 | |
| — | 200.00 | — | — | ||
| Supply and laying of 50 mm Diameter PE 100 HDPE Pipe for safety of cables including all the ends should be sealing with bituminous compound. | — | — | — | 12,012 | |
| — | 200.00 | — | — | ||
| Supply of LTUG Cable with Alu conductor, XLPE insulated and armoured, 4 x 95 sq mm as per IS-7098 part -1 or latest. | — | — | — | 94,002 | |
| — | 400.00 | — | — | ||
| Laying of 4 x 50-240 Sq mm LTUG cable with aluminium conductor including end terminations at both ends. This work includes Extension of power supply from the nearest power supply source in the excavated cable trench/in trough/on building walls/sheds/shelters etc. | — | — | — | 8,696 | |
| — | 100.00 | — | — | ||
| Excavation of cable trench, 450 mm. wide and 1000 mm. deep in all types of soil and refilling the cable trench to original shape by excavated soil free from unwanted materials. | — | — | — | 17,206 | |
| — | 380.00 | — | — | ||
| Connecting of light fittings, fans in platform to all night part night main circuits, running below PF shelter, with 3 No's of 1.5 sq mm for phase, neutral and earth PVC insulated stranded copper wire in 20mm dia PVC pipe and flexible PVC hose. | — | — | — | 1,71,585.2 | |
| — | 1300.00 | — | — | ||
| Supply, fixing, installation testing and commissioning of three phase copper lighting Bus way 40 A double circuit (8 conductors ), straight length with Tap-off provision, along with blanking plate. | — | — | — | 40,07,991 | |
| — | 12.00 | — | — | ||
| Supply and fixing of End feed units with cover suitable for lighting Bus bay, 40A Double circuit (8 conductors). | — | — | — | 59,438.76 | |
| — | 800.00 | — | — | ||
| Supply and fixing of Bracket suitable for wall/suspension mounting of Lighting bus bay 40A double circuit (8 conductors). | — | — | — | 60,784 | |
| — | 800.00 | — | — | ||
| Supply, fixing, installation testing and commissioning of 10A Tap-off unit L+N+E pre- wired with 1 meter length. | — | — | — | 8,23,856 | |
| — | 170.00 | — | — | ||
| Supplying and installing of 300 mm width X 50 mm depth X 1.6 mm thickness size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. (To run Power supply over FOB). | — | — | — | 1,80,540 | |
| — | 4.00 | — | — | ||
| Supply, Freight, installation testing and commissioning of Potable water purification system with inbuilt water cooler. RO + UV + Copper with storage tank capacity 80 Ltr, Stainless steel SS 304 with foundation and other hardware accessories complete as per site requirement. And all other as per detailed specifications complete. | — | — | — | 4,38,120 | |
| — | 4.00 | — | — | ||
| Supply of Portable fire extinguisher DCP type with nozzle and discharge fitting for ABC class of fire having ISI mark to IS -15683 / 2018 Rev.1. Capacity of fire extinguisher 6 Kgs. Fire Extinguishers having composite / SS / Aluminium cylinder of same fire rating as per latest IS- 15683:2018 Rev.1. -Firm's offer: same as above (Warranty Period: up to 30 months from the date of supply). | — | — | — | 4,602 | |
| — | 1.00 | — | — | ||
| Supply of Aluminium Wall Supporting Straight Ladder with Top Hook, Height: 10 feet, Step Type: Flat, fitted: Bottom Rubber, Minimum Load Capacity: 150 kg, C-Section Details (Approx.): 66.67 mm x 31.75 mm, Colour: Silver Conforming to IS: 3696-2 or Latest, (After receiving of the material same to be Handed over to Concern SSE/E for further maintenance of assets) | — | — | — | 3,540 | |
| — | 1.00 | — | — | ||
| Additions/alterations of interconnectivity of power supply, LTUG cable for outgoing feeders at PF LT panel board, fixing and mounting work etc., {The tenderer shall consult and obtain permission with Rly., Engineers before commencement of work each step/occasion} | — | — | — | 2,173.75 | |
| — | 1.00 | — | — | ||
| Supply and fixing of 1 phase meter box of suitable size with double door and with viewing MC along with suitable hardware and accessories complete. | — | — | — | 2,441.79 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCApril-2022.pdf
ATTACHMENT
JPOintenderdocumnets.pdf
ATTACHMENT
AdvanceCorrectionSlips1-11toGCC-2022.pdf
ATTACHMENT
AdvanceCorrectionSlips12toGCC-2022_compressed.pdf
ATTACHMENT
TB-PANPS-ProvisionofGeneralwaitingroom.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].