Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC KOIL KOIL PULWAMA PULWAMA JAMMU KASHMIR 192301 | PULWAMA | JAMMU AND KASHMIR | 192301 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹13.0 L+₹47,688.45 (3.79%)Rejected-Finance AZAD COLONY B 90 FEET ROAD SOURA SRINAGAR J K 190011 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190011 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹13.2 L+₹60,057.45 (4.78%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹14.9 L+₹2.3 L (18.5%)Rejected-Finance 184 TENGPUNA PULWAMA PULWAMA PULWAMA JAMMU KASHMIR 192301 UDYAM JK 15 0009999 | PULWAMA | JAMMU AND KASHMIR | 192301 | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹15.1 L+₹2.5 L (20.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
₹19.4 L
EMD Value
₹38,840
Closing Date
27 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) AWANTIPUR
GE (AF) AWANTIPUR, 8 FBSU, AF AWANTIPUR
SPECIAL REPAIR/REPLACEMENT OF HPSV LIGHTS TO LED LIGHTS PH-II AT 8FBSU
2021_MES_491138_1
GE (AF) AWA-33/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) AWANTIPUR
AS PER NIT AND TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (AF) AWANTIPUR
₹38,840
Yes
8 Feb 2022
29 Nov 2021
29 Dec 2021
29 Nov 2021
27 Dec 2021
14 Dec 2021
60 days
Amount
Excavation in trenches n.exc 1.5 metre wide and n.exc 1.5 metre deep for laying of cables or other items and getting out in any type of soil, complete all as specified and directed.
Sand cushioning to underground cable 8 cm thick layers below the cable and 15 cm thick above the cable in trenches using fine screened river sand, free from sharp particles, complete all as specified and directed. Note :- Punned thickness shall be measured and paid.
Well burnt old size sub class 'B' bricks of nominal size 230X115X75 mm abutting each other and laid perpendicular to the axis of cable for cable protection, complete all as specified and directed.
Returning filling in (soil) including spreading leveling, watering and well ramming in layers n. exc 25cm, complete all as specified and directed.
Removal of excavated material (soil) to a distance n.exc 50 metres and depositing where directed at a level n.exc 1.50m high from the starting point, complete all as specified and directed.
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 95 Sqmm, 3.5 core including making electrical connections, complete all as specified and directed. MAKE:NICCO,INDOASIANCABLES,HAVELLS,KALINGA, GOLD,PLAZA,PARAGAON
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 50 Sqmm, 3.5 core including making electrical connections, complete all as specified and directed. MAKE:NICCO,INDOASIANCABLES,HAVELLS,KALINGA, GOLD,PLAZA,PARAGAON
Supply, laying or passing through pipe underground cable PVC sheathed, XLPE insulated armoured LT 1100 volts grade with aluminium conductor of size 25 Sqmm, 3.5 core including making electrical connections, complete all as specified and directed. MAKE:NICCO,INDOASIANCABLES,HAVELLS,KALINGA, GOLD,PLAZA,PARAGAON
Factory made sheet metal encloser (junction pannel) CPRI approved made out of 14 SWG CRCA sheet powder coated weather proof out door type with 60cm long legs 4 Nos made out of 40X40X6mm equal angle size of encloser not less than 120X75X45cm depth with front and rear openable double door with locking arrangement including 4 strip aluminium bus bar of current carrying cap 100 Amp of lengh 75 cm, mounted on insulators including and connection in the new chamber with bolts and nuts, including thimbles of suitable sizes, neccessary earth work and PCC foundation for grouting of four legs, complete all as specified and directed.
Taking down old unserviceable sodium/HPSV fittings complete with all accessories, complete all as specified and directed.
Supply and fixing of warm white LED flood light fixture ≥ 150 Watt LED with pressure die cast aluminium housing with toughened glass having IP-66 degree of protection, individual LED's must have secondary lense for better throw across and along the road, with system luminarie efficacy ≥100 lumen/watt, colour rending index(CRI) of ≥ 70, co-related colour temperature (CCT) of 5700K. Luminaire should have surge protection upto 05 KV and having additional surge protection upto 10 KV for driver, PF ≥ 0.9 and THD ≤10%, operating voltage range from 140 to 270 volt, The potted driver used shall be a constant curent driver with efficiency of ≥ 85%.The manufacturers LOGO shall be engraved into housing of luminaire.Make of LED fitting model JETAIRISFLS 150W LED 757 PSYMLTG of havells or equivalent in crompton/Bajaj. Note: (i) Contractor shall obtain LM 79 & LM 80 test report (From third party NABL lab only ) for the light fitting from the manufacture before supply of material and submit it to the department. (ii) A certificate from the manufacturer for warranty minimum upto 2 year shall be obtained and submitted to GE.
Supply and fixing of warm white LED street light fixture ≥ 100 Watt LED with pressure die cast aluminium housing with toughened glass having IP-66 degree of protection, individual LED's must have secondary lense for better throw across and along the road, with system luminarie efficacy ≥100 lumen/watt, colour rending index(CRI) of ≥ 70, co-related colour temperature (CCT) of 5700K. Luminaire should have surge protection upto 05 KV and having additional surge protection upto 10 KV for driver, PF ≥ 0.9 and THD ≤10%, operating voltage range from 140 to 270 volt, The potted driver used shall be a constant curent driver with efficiency of ≥ 85%.The manufacturers LOGO shall be engraved into housing of luminaire.Make of LED fitting model ENDURAPEARL MAGNUMSL 100 W LED 757PASYTOTGAST of HAVELLS OR EQUIVALENT IN CROMPTON/Bajaj. Note: (i) Contractor shall obtain LM 79 & LM 80 test report (From third party NABL lab only) for the light fitting from the manufacturer before supply of material and submit to the department. (ii) A certificate from the manufacturer for warranty minimum upto 2 year shall be obtained and submitted to GE.
Supply & fix, bracket for fixing of LED light on pole made out of 50 mm dia G.I pipe 1.5 mtr long light grade bent to shape with suitable type of MS clamp of size 40mmX5mm thick MS flat nuts, bolts and washers, duly painted, complete all as specified and directed.
Supply and fix moduler box made of FRP / impact resistance plastic & heat resistant materials including provision of MCB SP 6A, connector terminal block 4 pole suit for fixing cable conection and fixing to pole/Wall with suitable sizes of clamps, nuts and bolts. MS works duly painted with two coat of synthetic enamel paint over a coat of red oxide primer,complete all as specified and directed.
S&F in replacement of PVC insulated, sheathed, multi stranded, three core, 1100 volts grade copper conductor cable of size 2.5 sqmm, complete all as specified and directed. MAKE: KINJAL,HPL,HAVELLS,PLAZA,PARAGON,GLOSTER
Earthing complete with galvanized mild steel plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically (in earth pit not less than 2.25 meter deep below ground level) with the top edge of earth plate at a depth not less than 1.5 meter below normal ground level, the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15 cm on all sides and including GI strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth (Plate) electrode at one end and connected to main switch board /panel/ test point at the other including watering GI pipe (medium grade) 20 mm bore from bottom of earth pit to top of electrode and 40 mm GI pipe light grade for earth strip protection complete with earth pit in PCC (1:2:4) type B1 using 12.5 mm graded crushed stone aggregate, RCC cover, (1:2:4) type B1 using 12.5mm graded stone aggregate and xpm steel reinforcement with 10mm MS handle funnel, wire mesh including necessary excavation and earth work in any type of soil, returning filling in and removal of surplus soil, complete all as specified and directed
Note :- An amount of Rs. 37,620.00 on account of credit schdule for Sch 'A' Part-II Shall be deducted from the total amount of BOQ to arrive at the contract sum.
FG CONSTRUCTION
M/S LEO TRADERS
M/S BASHIR AHMAD AND SONS
M/S Bali Agencies
ORISON ENTERPRISES
MS Ghulam Hassan and Sons
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .