Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹32.0 LAccepted-AOC | L-1 | Accepted-AOC L-1 | |
| 2 | L-2₹37.3 L+₹5.3 L (16.7%)Rejected-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L-2 | Rejected-AOC L-2 | |
| 3 | L-3₹43.6 L+₹11.6 L (36.2%)Rejected-AOC | L-3 | Rejected-AOC L-3 | |
| 4 | L-4₹45.1 L+₹13.1 L (40.8%)Rejected-AOC | L-4 | Rejected-AOC L-4 |
Tender Value
Refer Docs
EMD Value
₹94,480
Closing Date
13 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Jammu
GE Jammu c/o 56 APO Pin-180003
CERTAIN E/M LBW WORKS, REVENUE WORKS AND MINOR WORKS AT SUNJUWAN, MIRAN SAHIB AND DAMANA UNDER GE JAMMU
2020_MES_392031_3
GEJC-49/2020-21
Open Tender
Job Works
Item Rate
180 days
AoR of GE Jammu
Please refer Tender Documents
8 documents required · 8 mandatory
₹500
GE Jammu
₹94,480
Yes
31 Mar 2021
20 Feb 2021
15 Mar 2021
20 Feb 2021
13 Mar 2021
22 Feb 2021
60 days
Amount
Supply, installation, testing, lowering and commissioning submersible pumping set three phase 415 Volt AC suitable for 250mm dia bore well having discharge 8500 to 10000 GPH and head 85-100 mtrs complete with CI / GI jointing coupling piece suitable and matching with the existing MS column pipe of size 125mm dia suction and 150mm dia discharge complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing of Submersible cable 16 Sqmm 3 core flat copper conductor heavy duty 1100 Volts grade confirming to ISI all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning of diesel engine driven water cooled turbo charged generating set of capacity 63 KVA, 415 Volts, AC supply, 50 Hz, 3 phase, 4 wire, 0.8 PF at NTP, with CPCB approved acoustic enclosure, speed 1500 RPM, mounted on common base plate with flexible coupling and meeting the requirement of IS-4722 / BIS specification complete in all respect with extended warranty of 5 years with and including the following: - (a) Diesel Engine :- Water cooled turbo charged diesel engine of adequate capacity at 1500 RPM under NTP condition with governor suitable to regulator speed of DG set from No load to full load provided with blower fan, 12 Volts self starting system including maintenance free battery of 12 volts, 180 AH, charging dynamo / alternator, air cleaner, diesel oil filters, complete in all respect. (b) Fuel Tank: - Fuel Tank of adequate capacity for 12 hours running with stop cock, drain plug and necessary fuel pipe, manufactured out of MS sheet, complete all as per manufacturer's recommendations.
(c) Alternator: - Alternator suitable for continuous operation generating 63 KVA at 1500 RPM, 415 Volts, 0.80 power factor (lag) suitable for 50 Hz, 3 phase, 4 wire system. The alternator is brushless type screen protected, revolving field, self excited, self regulated through an AVR. The alternator has the following features : +1.0% voltage regulation (Max) in static conditions, IP : 23 protection wih insulation class H, Permissible overload of 10% for one hour in 12 hours of operation. (d) Control Panel: - The control panel consists of the following parts: - (i) Generator set controller microprocessor based multifunctional with LED display for engine water temperature, Lubricant oil pressure, Engine RPM, Engine shut down display, total hours run and suitable for protection against high water temperature, low lubricant oil pressure, over speed and battery charger failure. (ii) Digital multifunctional meter with LED display suitable to display all electrical parameters of individual phase such as voltage, current, frequency, KVA, KW, power factor and having RS 485 communication port complete with appropriate CTs and control wings.
(iii) MCCB 4 pole 415 Volts AC of suitable capacity with aluminium bus bar all as per manufacturer's recommendations. (iv) HRC fuses for protection as per standard engineering practice and manufacturer recommendations for protection of meters etc. (e) Electric Starter equipment: - The equipment will be comprised of the following: - (i) Maint free battery duly initially charge and battery lead of adequate cap. (ii) Starter motor (iii) Starter gearing (iv) Start / Stop Push button (v) Alternator / Dynamo of suitable capacity to charge the batteries while DG set is running complete with auto cut out all as per manufacturer's recommendations. (f) PCC foundation including all civil works for DG set all as per manufacturer's recommendations and all as directed. (g) AMF Panel for 63 KVA complete with relay panel and switch gears for automatic starting on main failure, control panel having meter and sound proof canopy as per CPCB norms and foundation etc.
M&L for replacement Earthing complete with galvanised steel earth plate electrode 60 X 60cm X 6.3mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel including GI protection pipes 15mm dia light grade and 20mm dia watering pipe medium grade upto test point, charcoal common salt, PCC 1:2:4 type B-1, Pit, CI cover with Handle, excavation and earth work in any type of soil, returning, filling and removal of surplus soil where directed to a distance n.exc. 50m rest complete all as shown in Electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross- sectional area 95 Sqmm, 3.5 core, complete all as specified and as directed by Engr-in-Charge. Note: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross- sectional area 70 Sqmm, 3.5 core, complete all as specified and as directed by Engr-in-Charge. Note: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross- sectional area 16 Sqmm, 4 core, complete all as specified and as directed by Engr-in-Charge. Note: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
M&L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross- sectional area 10 Sqmm, 4 core, complete all as specified and as directed by Engr-in-Charge. Note: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr depth in hard / dense soil getting out and levelling of bottom surfaces to required level for poles / stay assembly / cable all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25m thick all as specified and as directed.
Removing excavated material from site to a distance not exceeding 50mtr away and depositing where directed not exceeding 15mtr from the starting point all as specified and as directed.
M&L of GI Pipe light grade 50mm bore for cable protection as a guard pipe complete all as specified and as directed.
M&L Sub class 'B' bricks well burnt laid with length perpendicular to the axis of the cable in trenches for protection to cable complete all as specified and as directed.
Supplying and Laying in trenches Clear Sand for cushioning under ground cable 8 cm below and 15cm above complete in level all as specified and as directed.
M&L for aluminium earth strip size 25 X 3mm thick complete with replacement of MS saddle / clamp fixing screw etc for roof conductor and down conductor above ground and on wall complete all as specified and as directed.
M&L for test point terminal block made of MS strip of size 32 X 6 mm of suitable size drilled and screwed including 4 No's 8mm dia 25mm long hexagonal head screw complete all as specified and as directed.
Supply and fixing in replacement of on load open execution change over switch front handle operated 4 pole, 415 Volt, 50 Hz, 125 Amp confirming to IS complete all as specified and as directed by Engr-in-Charge.
Supply, installation, testing and commissioning replacement of LT panel of suitable size for 3 phase, 415 Volt, outdoor weather proof vermin proof duly powder coated double door with back and front opening made out from 3.0mm thick CRCA sheet with angle iron base frame of size 50 X 50 X 6mm cubical type complete with aluminium bus bar 200 Amp 4 way with proper colour coding complete with PVC insulator, with IP 54 as per IS 13947 protection, fault rating 50 KA/1 sec, complete with foloowing items including: -
MCCB 4 pole, current rating 125 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 36KA at 415V, 50 Hz, -01 No as incomer.
MCCB 4 pole, current rating 100 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 25KA at 415V, 50 Hz, -01 No as outgoing.
MCB 4 pole, current rating 40 Amp, with adjustable thermal magnetic setting 70%-100% breaking capacity 25KA at 415V, 50 Hz, -01 No as outgoing.
Supply and fix in replacement of on load open execution change over switch front handle operated 4 pole, 415 Volt, 50 Hz, 125 Amp confirming to IS all as specified and as directed by Engr-in-Charge.
MCB SPN 32 Amps, 'C' series 10 KA - 2 No
Indicator Lamps (LED type) showing R,Y,B phases - 01 Set
Internal panel wiring with suitable multistranded copper conductor PVC insulated and sheathed FRLS complete with copper thimble / lugs.
Angle iron base frame as required size as per above panel, total leg height 600 mm and grouting in side PCC 150mm legs and made out of ISA 5050, 50 X 50 X 6mm thick angle iron duly painted - 01 No
Necessary foundation in PCC 1:3:6 (40mm graded crushed stone aggregate) type C-2 for foundation of angle iron legs frame work complete - 01 Job.
S&F Servo Voltage Stabilizer 250 KVA for automatic operation, three phase naturally oil cooled indoor type and designed for input variation between 340 V to 480 V with output voltage stabilized at 415 with accuracy + 2.5 % and speed of correction 8 Volts per second and of capacity including 1st filling of transformer oil complete with provn of over load and short circuit protection, high low voltage, cut off and by pass arrangements etc complete all as specified and as directed.
Supply and lay cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 300 Sqmm 3 1/2 core complete all as specified and as directed by Engr-in-Charge. Note: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connecting to the iron strip 25 X 4mm using 40mm pipe for protection by means of bolts, nuts, check nuts and washer of GI bore including provision of concrete pit in PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregates with CI cover wih suitable angle frame and handle, GI light grade 20mm bore pipe for watering, perforated at bottom, 1.75 mtr long placed on top edge of earth plate, charcoal and common salt filling, funnel, wire mesh and earth work in hard / dense soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtr all as per electric plate No 5 of SSR part-I and connecting to earth test point all as specified including testing on completion.
M&L for Aluminium thimble of size 150 to 300 Sqmm of ISI mark complete all as specified and as directed.
Supply and fix water heater (Geyser) 25 ltr Cap metal body, single phase with working voltage 240 Volts, 50 Hz ISI marked complete all as specified and as directed confirming to ISI. Note: - Rates are included in the cost for fixing of 4 No's rawl plug of suitable size (4"-6") nuts and bolts, grouting work in RCC / Brick wall.
M&L Point wiring with 2.5 Sqmm (nominal area), PVC insulated, multistranded, single core unsheathed, copper conductor cables FRLS drawn through and including concealed in PVC conduits with all accessories complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point including 1.6mm thick mild steel sunken boxes of suitable size with 3mm thick hylam sheet top cover fixed with suitable size of brass screws for mounting switches, sockets, regulators etc complete for one light / fan / bell point controlled by one, one way switches complete all as specified and as directed.
S&F switch socket combination 2 in 1, 5/16 Amps, 5 in 1, flush type, with fuse and neon indicator complete all as specified and as directed by Engr-in-Charge.
M&L for cutting existing pipe in position and insertion of T and bends as required and connecting new GI pipe complete all as specified and as directed.
Supply and fix Galvanised iron steel tubing medium grade of size 15mm complete with all fittings such as bend, tee, reducer, elbow and union of required size complete all as specified and as directed.
Supply and fix gun metal or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete of size 15mm dia complete all as specified and as directed.
Supply and fix PVC connection (HOT / COLD) Heavy duty ISI Marked both end brass nuts complete all as specified and as directed.
Supply and fix Bib Tap fancy type cast copper alloy with crutch or butterfly handle, screwed down for iron pipe 15mm dia complete all as specified and as directed.
Supply and fix NRV for 15mm dia pipe complete all as specified and as directed.
Supply and fix steel body Desert cooler electric driven (single phase) having nominal air flow capacity of 4000 CuM per hour, body made out from PGI sheet 22 gauge (SWG) including submersible pump of suitable capacity, Fan motor 90 watt at 2800 RPM complete with electric connection three core copper conductor and 5 Amp top plug complete all as specified and as directed by Engr-in-Charge.
Supply, Fabrication and installation of Angle iron frame stand of suitable size as per site requirement for desert cooler made out from angle iron 40 X 40 X 6mm thick bend to shape and cut duly mounted in brick / stone / masonery wall including iron clamp / nut and bolt complete with black painted two coat over a coat of red oxide primer complete all as specified and as directed by Engr-in-Charge.
M&L for Point wiring complete with 1100 Volts grade PVC insulated unsheathed cable of copper conductor (FRLS) multistranded of size 1.5 Sqmm, single core, in and including continuous earth wire of size 1.5 Sqmm unsheathed stranded copper conductor (FRLS) with green PVC insulation connected to common earth dolly drawn into rigid non-metallic PVC concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes, bakelite sheets, PVC rectangular boards / round blocks (for housing lamp holders and sketch fittings etc) including cutting chases for conduit and sinkings for boxes and providing MS concealed terminal boxes made of MS sheet with 3mm thick plastic laminated bakelite (Hylum) sheet to cover for mounting switches / bell pushes / sockets, fan regulators etc complete all as specified and as directed.
One 5 Amps 3/5 pin socket outlet on the independent board with other switch complete all as specified and as directed by Engr-in-Charge.
Supply and fixing only switch piano flush button type 05 Amp single pole, one way complete all as specified and as directed.
S&F only socket outlet multi purpose 3 pin 2 pin 05 Amp flush type complete all as specified and as directed.
Supply and installation of silent Diesel Engine driven generating capable of delivering 15 KVA or of next higher capacity as per available / manufactured 415 Volts (AC 3 phase, 4 wire system of supply) 50 Hz at power factor 0.8 minimum. The DG set shall consist of a diesel engine coupled directly to a matching parts or as recommeded / provided by the manufacturer on a common base frame and thereafter installed in the CPCB approved acoustic enclosure. (The complete set conforming to and test certificate as per CPCB norms and as specified) all as specified complete with AMF Control panel standardized by manufacturer, fuel tank with mounting arrangement flexible exhaust pipe complete and shall comprise the following: -
(a) Engine (Prime mover) : Diesel Engine 1500 RPM of minimum or recommended by manufacturer water cooled / Air cooled, 12 Volt 75 AH maintenance free dry electric battery start, complete with fly wheel and all standard fittings / fixtures as per manufacturing practice including suitable engine control panel / Dash Board with electronic technometer, Lubricant Oil temperature and Pressure gauges water temperature gauge and frequency meter (digital type) including safety automatic shut down in case of fault detection such as high water temperature, low lubrication of pressure, over speed and also including self starter, alternator, cogged V belt, fuel tank with first all of lubricant oil and coolent (as applicable) etc.
(b) Alternator:- Alternator AC Alternator, 3 phase 415 Volts, 4 wire rated line current for output 15 KVA PF 0.8, 1500 RPM insulation class enclosure / SPDP self excited, self regulated brushes, complete with AVR with plus and minus voltage regulation directly coupled to and match the above engine. (c) Anti vibration pads for mounting engine alternator assembly on the base frame / plate or as recommended / provided by the manufacturer. (d) Base Plate :- Made out of structural steel as per manufacturer's recommended design / specification.
(e) Acoustic Enclosure provision of an internal type approved / certified acoustic enclosure (Make of enclosure shall be as per CPCB norms for the DG sets to restrict the noise level to 75 db at one meter distance and temp rise within canopy shall not exceed 7 degree centigrade beyong ambient temp. It shall be made of 16 SWG or manufacturer's standard norms CRCA sheet with powder coated finish on outside and provided with non igniting fire retardant foam as acoustic material. The door and glass windows shall be of ISMC. It shall also include the following: - (i) Silencer: - Absorption the non-resistance, residential and exhaust pipe covered with asbestos rope. (ii) Internal wiring with PVC copper conductor cable IS 694 marked FRLS in conduit and LED Lamp fitting with control switch. (iii) Fuel tank of 12 Hours capacity but not less than made of 14 SWG CRCA sheet duly powder coated and provided with float, gauge and fuel float switch. (f) Batteries as recommended by manufacturer. (g) DG set maintenance tool kit as provided by manufacturer.
Earthing complete with galvanised steel earth plate electrode 600 X 600 X 6mm thick buried directly in ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filling in alternate layers, all around, top and bottom and electrode connection by using galvanised iron earth lead strip of size 32 X 6mm flat iron by means of bolts, nuts, check nut and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 40mm bore protection pipe light grade for protection strip upto 3m above ground level (upto the body of equipments) PCC chamber in cement concrete (1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion: -
The unit rate shall include for protection pipe, GI water pipe, funnel, wire mesh excavation, RCC pit cover, test point, 32 X 6mm galvanised strip from top of earth plate upto 5 mtr above ground level and if GI protection is less than 5m, no price adjustment shall be made.
PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc shall be deemed to be included in the unit rate.
If the testing result of earth work is not been found satisfactory than the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account.
Earthing work will be carried out in presence of MES representative.
Supply and install on load change over switch 415V in sheet metal enclosure 4 pole of capacity 63 Amp on wall / angle frame with necessary drilling and thimbles as required at site complete all as specified and as directed by Engr-in-Charge.
Supply and laying, jointing and testing XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100 Volt grade with stranded aluminium conductor of size 25 Sqmm 4 core with earthed system confirming to IS 7098-1985 laid in trenches in floor, in ducts through pipes or along the pole complete all as specified and as directed by Engr-in-Charge. Note: (i) Wherever cable fixing/connection, suitable thimble should be used as per site situation. (ii) Excavation and earth work, sand cushioning, brick work and GI pipe shall be measured and paid separately.
Supply, install, commission and testing cubical type LT panel board, outdoor type, manufactured by a CPRI approved factory, floor mounted, dust and vermin proof, front and rear operated door with necessary locking arrangement made of 50 X 6mm MS angle iron frame work and CRCA sheet of 3.15mm thick duly painted with two coats of powder coated paint of approved shade both internally and externally. The panel shall be suitable for 415 Volts, 50 Hz, 3 Phase, 4 wire system and shall be complete with suitable capacity copper bus bar (1.5 times the incoming switch gear current rating) with suitable size of PVC insulated copper conductor, thimbles glands complete all as specified and as directed with the following accessories: -
MCCB 4 pole 63 Amps, breaking capacity 25 KA at 415 Volt AC, 50 Hz (Incoming) = 01 No's.
MCCB TP 63 Amps breaking capacity 25 KA at 240 Volt AC, 50 Hz (Outgoing) = 1 No's.
MCB Isolator 40 Amps, SPN 10 KA = 02 No's Outgoing.
LED indicating lamp (RYB)
Note: - The rate quoted shall also include providing excavation and PCC foundation as required.
Supply, installation, commissioning of hi wall split unit indoor / outdoor complete with cord less remote control unit and with in built air ioniser and plasma filter for better indoor air quality with minimum 3 star rating and EER 3.2 of capacity 2 Ton including necessary angle iron frame suitable to take the load of outdoor unit including PCC / Grouting work in wall complete with necessary nuts / bolts complete all as specified and as directed by Engr-in-Charge.
Supply and fix Voltage Stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 90 V to 250 V with output voltage stabilized at 230 Volt with accuracy of +2.5 % and of capacity 5 KVA complete with provn of hanging / fixing on wall mounting bracket all as specified and as directed by Engr-in-Charge.
Supply and draw sub main wiring in pairs of two run 16 Sqmm single core PVC FRLS insulated, unsheathed multistranded copper conductor cable 1100 Volt grade, draw through and including PVC conduit medium duty and accessories of 25mm size and fixed with PVC saddles and cadmium plated steel screws to the surfaces of the wall / ceiling including one run of 10 Sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. Note: - Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.
Supply and fixing copper cable PVC insulated 120 Sqmm single core in red and black colour coding confirming to IS-7097 Part - I with necessary thimbles glands all as specified and as directed by Engr-in-Charge.
Supply and fixing copper cable PVC insulated 16 Sqmm single core in red and black colour coding confirming to IS-7097 Part - I with necessary thimbles glands all as specified and as directed by Engr-in-Charge.
Supply and draw sub main wiring in pairs of two run 6.0 Sqmm single core PVC insulated FRLS, unsheathed multistranded copper conductor cable 1100 Volt grade, drawn through and including PVC conduit medium duty and accessories of 25mm size and fixed with PVC saddles and cadmium plated steel screws to the surfaces of the wall / ceiling including one run of 4 Sqmm single core PVC insulated unsheathed copper earth continuity conductor all as specified and as directed. Note: - Two runs of single core cable with one run of earth continuity conductor including PVC conduit accessories shall be measured and paid as one length.
S&F single pole and neutral enclosure with a two pin and earth plug and socket completewith one single pole MCB 20 Amps all as specified and as directed.
Supply and fixing 24" wide galvanised cable tray including all accessories i.e. nuts, bolts, washers, clamps, turning tray etc as per site requirement wih provision of pipe / angle from ceiling to tray for support and angles at walls all as specified and as directed.
Material and Labour for installation maintenance free chemical earthing system through specialize Agency to obtain earth resistance less than one Ohm by providing one No Copper Electrode of size 65mm dia having 3mm thick wall thickness 03 meter long to be placed vertically in 153mm dia bore at centre and four No's copper rod of size 17mm dia 03 mtr long to be placed vertically in 65mm dia bore and six meter away diagonally from the copper electrode and inter connected to each other with 32 X 6mm copper strip, 60cm below the ground level by means of bi-metallic 'U' clamps and covered with isogel / earth enhancing compound and extended upto test point i.e. upto length of 7.5 mtrs including supply and fixing of test point made out of brass of size 120 X 120 X 25mm in IP-55 enclosure, 40mm dia GI pipe light grade for earth lead protection, filling of bore with isogel from Tercel or any other Earth enhancement material @ min 40 Kg per electrode, PVC pit with PVC cover of suitable sizes and locking arrangement including necessary auguring / Drill / Boring / excavation and earth work in any kind of soil and disposal of soil to a distance not exceeding 50 mtr and necessary testing complete. Note: - (a) The work and testing shall be carried out in presence of Engr-in-Charge. (b) All jointing to be carried out by brazing in lieu of bolts and nuts. (c) The contractor is fully responsible to achieve the desired result and no extra payment will be made for using additional quantity (if required to achieve the result) of isoagel / earth enhancing compound etc.
Supply and fix Earth continuity conductor copper strip of size 32 X 6mm flat strip fixed to wall on pattern or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as specified and as directed.
Supply and fix MCBs DB TPN 6 way double door with necessary cutting and plastering to wall complete all as specified and as directed.
Supply and fix MCB TPN 415 V, 32 amps complete all as specified and as directed.
M&L for point wiring for one light / fan point / call bell point controlled by one 5 Amp switch with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 Sqmm copper conductor multistranded FRLS, PVC insulated (unsheathed) drawn into and including new concealed PVC rigid / non metallic conduit and connecting with existing CI / pressed steel terminal boxes including 3.00mm thick hylam brand IS-2036 marked, laminated top sheet cover for mounting switches, sockets, fan regulators etc complete all as specified and as directed. Note: - (a) Wiring shall be done by using proper colour coding. (b) Earth wire shall be of green colour.
One light point controlled by one 5 Amp switch one way complete all as specified and as directed.
M&L switch piano flush type single pole one way 5 Amp complete all as specified and as directed.
M&L ceiling rose surface bakelite white with three terminal including connecting and testing complete all as specified and as directed.
Making holes for 300mm dia exhaust fan of suitable shape and size into or through brick walls at grouting / First floor including plastering for making good to the original surfaces of any description disturbed including painting / distemper matching with the existing colour complete all as specified and as directed. Note: - Rates are deemed to be including charges of any type of T&P, Insurance of staff deployed at site.
S&F exhaust fan steel body of 300 mm sweep 230 V complete with louver shutter including fixing rawl plug / nut and bolts complete all as specified and as directed.
Supply and fixing LED street light fitting 60 Watt 230V AC outdoor type with high pressure di cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 / 66 protection complete all as specified and as directed.
M&L for street light bracket, made out of suitable size GI / MS pipe, (medium grade) of suitable length, bend to shape as required and welded and fixing in position with MS clamps, nuts and bolts complete all as specified and as directed.
Supply and fix in replacement three core flexible copper conductor cable of size 1.5 Sqmm all as required, drawn into conduit / pipe or pole fixed to wall for security light connection all as specified and as directed by Engr-in-Charge.
M&L in replacement of GI pipe light grade 50mm bore for cable protection complete all as specified and as directed.
Labour work for fixing / laying steel tubing pipe complete with earth work as per site requirement complete all as specified and as directed.
Supply and fix MCB SPN 240 V, 40 amps complete all as specified and as directed.
SUMEET TRADING CORPORATION
vishesh engineers
M/S S K Electricals Regd
Bidder Name
M/S S K Electricals Regd
SUMEET TRADING CORPORATION
Dn construction and co
vishesh engineers
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .