Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC 12 NANDGAON PO NIGAHI DISTT SINGRAULI MP 486884 | SINGRAULI | MADHYA PRADESH | 486884 | L1 | Accepted-AOC AS PER TC DELIBERATION | |
| 2 | L2₹16.7 L+₹1.2 L (7.87%)Rejected-Finance | L2 | Rejected-Finance NOT L1 BIDDER | |
| 3 | L3₹17.0 L+₹1.5 L (10.0%)Rejected-Finance JAYANT DISTT SINGRAULI MP PIN 486890 | JAYANT | SINGRAULI | MADHYA PRADESH | 486890 | L3 | Rejected-Finance NOT L1 BIDDER | |
| 4 | L4₹17.8 L+₹2.4 L (15.3%)Rejected-Finance WARD 22 GHOROLI KALA DISTRICT SINGRAULI M P | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486887 | L4 | Rejected-Finance NOT L1 BIDDER | |
| 5 | L5₹22.8 L+₹7.4 L (47.8%)Rejected-Finance PLOT NO 17 18 EWS COLONY DISTT SINGRAULI M P PIN 486889 | SINGRAULI | SINGRAULI | MADHYA PRADESH | 486889 | L5 | Rejected-Finance NOT L1 BIDDER |
Tender Value
₹27.4 L
EMD Value
₹34,200
Closing Date
7 Mar 2024, 11:00 amClosed
GM EM Nigahi Area
Office of GM EM Nigahi Area, NCL, Singrauli, 486884
Replacement of Electrical wirings of New Workshop, Dumper Section and Dozer Section, Base Workshop, Pump House and Washing plants within the premises of New Workshop, Nigahi project.
2024_NCL_302581_1
NGH/EM/e-Tender/23-24/71 dtd. 24.02.2024
Open Tender
Miscellaneous Works
Item Rate
45 days
NCL Nigahi Area
as per NIT
4 documents required · 4 mandatory
₹34,200
27 May 2024
24 Feb 2024
8 Mar 2024
24 Feb 2024
7 Mar 2024
26 Feb 2024
24 Feb 2024 - 29 Feb 2024
Amount
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A "C" curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required: 150 A, 16 KA,TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required: 250 A,36KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required: 400 A,50KA,FPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required: 630 A,50KA,FPMCCB
300 A(Isc=20kA for 1 second) 300 amps. TPN, rising mains in metal enclosure with aluminium busbar including fixing clamp
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Single pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Double pole
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Triple pole and neutral
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: 63 amps., 4 pole isolator
Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
S.P. 5/6 amps, one way switch, piano type ISI marked
3 pin 5/6 amps socket outlet, piano type ISI marked
S.P. 15/16 amps, one way switch, piano type ISI marked
6 pin 15/16 & 5/6 amps socket outlet, piano type ISI marked
Providing and fixing of industrial plug and socket 415V, 63Amp, flange type, and water tight pin and sleeeve, With 5Pin(3P+N+E).
Painting of Electrical switch panel
Total impact of GST for the purpose of CTC
IDEAL SWITCHGEARS
M/S. AMAN ASSOCIATES
ITAUHA BROTHERS AND GROUP
M/S SARCO ENGINEERING WORKS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .