| 1 | FIRST₹19.8 LAccepted-AOC M S RRK PROJECTS D 306 ADG P CHENNAI 11 3RD CROSS SIR MV LAYOUT VIDHYARANYAPURA POST BANGALORE 560097 | BENGALURU URBAN | KARNATAKA | 560097 | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹20.6 LRejected-Finance | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹20.8 LRejected-Finance | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹21.3 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | FORTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹22.4 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹27.9 L
EMD Value
₹55,800
Closing Date
25 Dec 2022, 6:00 pmClosed
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIR TO INTERNAL ELECTRIFICATION INCLUDING METERS CEILING FAN GEYSER AND EXTERNAL ELECTRIFICATION INCLUDING FPs DBs LT PANEL CABLE STREET LIGHT AND APFC AT AKASH VIHAR UNDER GE AF MARATHAHALLI
2022_MES_559855_2
8993/E8
Open Tender
Civil Works
Item Rate
270 days
GE (AF) MARATHAHALLI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹55,800
Yes
19 Jan 2023
24 Nov 2022
30 Dec 2022
24 Nov 2022
25 Dec 2022
12 Dec 2022
Amount
Taking down unserviceable wire carefully copper/ aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., and making good the disturbed surfaces of walls, ceiling etc., including painting with same colour of the background, complete all as specified and as directed.
Wiring complete with 1.5 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories surface type run on walls/ ceiling incl MS terminal boxes mounted concealed on walls with hylon laminated sheet top cover 3 mm thick fixed with cadmium plated iron screws for housing the switches, switch socket and outlets, fan regulators etc., incl provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly, all as specified and as directed. (a) One Light point controlled by one switch
(b) One fan/Ex. fan point controlled by one switch.
(c) One 5A 2pin/3pin switch socket out let multipurpose on independent Board.
(d) One call bell point controlled by one bell push
All as per item No -02 above but wiring complete with 2.5 Sqmm for 5 pin 5/15A socket multipurpose on independent board. Note :- Item No 2.00 to 3.00 (i) The earth wire for the points shall be laid from the respective switch board only . (ii) Earth wire shall be taken inside the conduit. (iii) Cost of terminal box is deemed to be included in the item rate quoted for point wiring
S & F Switch piano flush type, single pole, one way 5 Amps complete all as specified and directed
S & F Switch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 230 volts complete all as specified and directed
S & F Switch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type , 230 volts complete all as specified and directed
S & F step type electronic fan regulator, - 2 module complete all as specified and directed
S & F PVC ceiling rose two to three terminals complete all as specified and directed
S & F ding dong bell AC, 230 volts, single pole complete all as specified and directed
S & F Socket outlet 2 in 1, 3 pin, 5A Flush type 230 volts complete all as specified and directed
S & F Socket Outlet 2 in 1, 3 pin, 5 and 15 amp flush type 230 volts complete all as specified and directed
S & F Switch Piano Flush type, Single pole, One way 230 volts 15 / 16 Amps complete all as specified and directed
S&FAngle holder PVC/polycarbonate type all as specified and as directed
S & F Modular Switch 1 way 6 Amps 1 Module complete all as specified and directed
S & F Modular Socket,6 Amps- 2/3 pin combined 2 Moduler complete all as specified and directed
S & F Modular Switch 1 way 16 Amps 1 Moduler complete all as specified and directed
S & F Modular Socket,6 A/16A,2 Moduler complete all as specified and directed
S & F Modular type Fan step regulator 120W type 2 moduler complete all as specified and directed
Supply and fixing 600x600mm surface/ recessed mounted LED Light fitting 36 /35 W,glare free uniform illumination acrylic diffuser,connector block etc., complete with all accessories and including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
Supply and Fixing LED Tube light fitting 1 x20 W,220V CRCA housing with PC diffuser box type with driver,holder including LED tube light connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
Supply and fixing LED light fitting mirror type high out put diffuser 2 feet 10 W 220 V AC recessed/surfaced type high efficieny with drivers, holders LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed
Supply and fix LED light fittings 1X9/1X10 bulkhead luminaries including LED drive holder connecting up with thre core flexiable copper conductor cable
Supply and fix LED 20 Watts tube light ultra bright polycarbonate suited for with G 13 Lamp holder all as specified and directed
Supply and fixing round shape LED recessed / surface light fitting 15 W complete with drivers ,holders LED lamps including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal Complete all as specified and as directed.
Supply and Fixing LED Bulb of 9 watts pin type all as specified and as directed. Make: Bajaj / CG / Havells
S&F MCB DB TPN 4 way, double door,415 V, AC, 50 Hz complete all as specified and directed
Supply and Fixing MCB SP 5 to 32 Amps rating, 10 KA Ç 'curve 240V, 50 Hz AC Complete all as specified and as directed.
Supply and Fixing MCB SPN 32 Amps rating, 10 KA 'C 'curve, 240V, 50 Hz AC Complete all as specified and as directed.
Supply and Fixing MCB TP 25- 63 Amps rating, , 10 KA Ç' crve 415V, 50 Hz AC complete all as specified.
Supply and Fixing in repairs MCB TPN 63 Amps rating,10 KA 'C' curve , 415V, 50 Hz AC Complete all as specified and as directed.
Material and Labour for sub main wiring 1100 volts grade PVC insulated FRLS multistranded copper conductors, two runs of single core 4 Sqmm along with one run 4 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC conduit all as specified and as directed Note :- 3 run of multistranded copper conductor and 1 run of PVC conduit shall be measured as one unit
Disconnecting the powersupply and taking down Ceiling fan ,Dismantling the defective Ceiling fans motor 1200mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional Complete all as specified and as directed.
Dis connecting the power supply and taking down the exhaust fan , dismantling the defective Exhaust fans motor up 300 mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional Complete all as specified and as directed.
Dis connecting the power supply and taking down the exhaust fan ,/wall mounting fan dismantling the defective Exhaust fans motor up 400 to 450 mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, and other petty items required for making motor functional Complete all as specified and as directed. Note: item No -32 to 34 - Servicing of Exhaust fans and Spares will be measured and paid separately under relevant items of this schedule.
Hanging Only Ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost Complete all as specified and as directed.
Supply Only GM bush suitable for Ceiling fan 1200 Sweep Complete all as specified and as directed.
Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 Sweep Complete all as specified and as directed. Make: SKF / NBC / TATA or equivalent.
Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed. Make - Usha / CG/ Havells
Supply and fix ceiling fan complete with blades down rod electronic rerulator and accessories 230 V 1200 mm sweep Min air delivery 210 CFM five star brushless (BLDC) complete all as specified and directed
Supply and fix exhaust fan steel body AC single phase 230 V 300 mm sweep with blades and frame with louvers complete all as specified and directed
Taking out unserviceable geyser element including supply and fixing heating element suitable to existing model and make 1.5 / 2 KW Dual clip type/tri angle type / round type with rubber gasket suitable for geysers up to 25 Ltr capacity .
Taking out unserviceable thermostat including supply and fixing thermostat clip type (Range 30 C° to 80 C and acting at 70 C°) for geysers up to 50 Lts all as specified .
Taking out un serviceable PVC connection including supply and fixing 15mm borePVC connections with brass nuts 650 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser complete all as specified and directed .
Taking out unservice pressure release valve including Supply and fixing pressure release valves suitable for geyser up to 50 ltrs capacity type asper existing PR valve complete all as specified and as directed .
Taking out the unservieable 3 core wire including supply and fix FRLS PVC Round insulated copper flexible cable 2.5 sqmm , 3 core PVC sheathed,1100 Volts grade complete all as specified and as directed.
Excavation in trenches in Soft / Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient complete all as specified and as directed.
Returning filling including Spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick Complete all as specified and as directed
Removing excavated material not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed.
Material and labour for riddled Sand Cushioning to cables a layer of 8 cm thick before laying the cable and second layer of 15 cm thick after laying the cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down.
S & F sub class burnt Bricks for cable protection Complete all as specified and as directed
Material and Labour for G.I. tubing light grade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts Complete all as specified and as directed.
Taking out old unserviceable UG cable, Supply and laying 25 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable, Supply and laying 16 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable, Supply and laying 10 Sqmm, 2 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Taking out old unserviceable UG cable, Supply and laying 10 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
Supply and Fixing MCCB DB TPN 4 way, Double door, 415 V, AC, 50 Hz, with 200 Amp rated bus bar
Supply and fix 415 KA'B' Curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commission TPN/FP 40 to 100 Amps all as directed and directed
Supply and Fixing MCCB Triple pole 415 volts 50 HZ AC suitable for current carrying capacity 25 to 100 Amps rating, fixed type with rupturing capacity 16 KA all as specified and directed.
Supply and Fixing MCCB 3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 630 Amps rating, fixed and thermal magnetic release with rupturing capacity 50 KA all as specified and directed.
Supply and Fixing in repairs MCCB 3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 160 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA all as specified and directed.
Supply and Fixing in repairs MCCB 4 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 200 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA all as specified and directed.
Supply and Fixing in repairs MCCB 4Pole, 415 volts 50 HZ AC suitable for current carrying capacity400 Amps rating, fixed and thermal magnetic release with rupturing capacity 36 KA all as specified and directed.
Material and Labour for preperation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint Complete all as specified and as directed.
Supply and fixing moulded (FRP) junction box with IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as directed
Supply and Fixing in repairs Voltmeter digital type 0-500 Volts Complete all as specified and as directed.
Supply and Fixing in repairs Ammeter digital type 0-200 Amps Complete all as specified and as directed.
Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 35 W LED street light fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection.
Taking out the unserviceableflood light fittings Supply and fixing 70 W LED flood light fitting 230V out door type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistants complete with driver and lamp
Taking out the unserviceable post top latern fitting ,Supply and Fixing post top lantern LED type 20 W 230 Volts AC out door type with decorative post top for 360 degree indirect light IP65 protection with impact and corrosion resistant Complete with driver and lamp
Supply Only in repairs 10/12. 5 KVAR Capacitor heavy duty existing make and type 440 volts with inrush current Limiting Coil Complete all as specified and as directed.
Supply Only in repairs 20 KVAR Capacitor heavy duty existing make and type 440 volts with inrush current Limiting Coil Complete all as specified and as directed.
S&F heavy duty contactor suitable for 25Kvar capacitor complete all as specified and as directed.
Supply Only Automatic power factor relay ( APFCR ) 8 stage complete all as specified and as directed.
Supply only duty contactor suitable for 20Kvar capacitor
Supply only duty contactor suitable for 12.5 Kvar capacitor
S&F duty contactor suitable for 25Kvar capacitor
S&F duty contactor suitable for 12.5/ 10 Kvar capacitor
M&L danger notice plate of 1.6 mm thick mild steel sheet vitrous enamelled white letters fifgre and conventional skull and bones in single red colour and fixed with MS clamps bolts and nuts of approved size for LT 20X15cm size
All as per item no 79 above, but, HT 25X20cm size
Vishwas Enterprises
SREE VARU ELECTRICALS
GKR and CO
Chandana Enterprises
MARUTHI CIVIL AND ELECTRICAL WORKS
Pacific Enterprises
VSHVAS CIVIL AND ELECTRICAL SERVICES PRIVATE LIMITED
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .