Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Lowest | |
| 2 | L2₹12.5 L+₹15,196 (1.24%)Rejected-Finance NO 26 GURU AMARDAS COLONY BHAINSA NAKA SAGAR MADHYA PRADESH 470001 | SAGAR | MADHYA PRADESH | 470001 | L2 | Rejected-Finance Not lowest | |
| 3 | L3₹15.1 L+₹2.8 L (22.6%)Rejected-Finance CHATAI SHEEP WARD NO 07 NEW MARKET ROAD AHIWARA DURG CHHATTISGARH 490036 | DURG | CHHATTISGARH | 490036 | L3 | Rejected-Finance Not lowest | |
| 4 | L4₹16.5 L+₹4.2 L (34.2%)Rejected-Finance MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L4 | Rejected-Finance Not lowest | |
| 5 | L5₹16.9 L+₹4.6 L (37.8%)Rejected-Finance | L5 | Rejected-Finance Not lowest |
Tender Value
₹18.4 L
EMD Value
₹37,000
Closing Date
22 Dec 2020, 6:00 pmClosed
Garrison Engineer Nasik Road
Garrison Engineer Nasik Road AOP Complex Near AOP Gate PO Gandhinagar Nasik 422006
As per Tender Documents
2020_MES_397908_1
GE/NRC/8793/E8
Open Tender
Civil Works
Item Rate
180 days
Garrison Engineer Nasik Road
As per NIT
8 documents required · 8 mandatory
₹500
Garrison Engineer Nasik Road
₹37,000
Yes
11 Jan 2021
24 Nov 2020
26 Dec 2020
24 Nov 2020
22 Dec 2020
8 Dec 2020
Amount
Dismantling carefully the existing unserviceable LT / HT Overhead line ACSR conductor of any size from its position by necessary disconnecting of conductor and removing complete all as directed by Engr-in-Charge.
Dismantling of existing unserviceable LT pole of any size & type ( RCC / MS) from its position carefully and removing from the site and necessary excavation and earth work in any soil / strata, demoltion of concrete, disconnection of conductor fom pole etc. complete all as directed.
Supply , laying and testing XLPE insulated screened PVC bedded galvanised steel strip armoured electric power cable (Heavy duty ) with aluminium conductor 11000 volts grade lay in trenches , ducts , along pole, along transformer cross sectional area 3 core 95 sqmm complete all as specified and directed.
Material and labour for high density polyethylene pipes (HDPE) of pressure rating 6 kgf / cm2 laid in trenches of size 90 mm suitable for cable protection of size upto 95 sqmm to 150 sqmm HT / LT cable complete all as specified and directed.
EXCAVATION BY TENCHLESS TECH - Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia. Suitable for 0.4 mpa working pressure.
Excavation in trenches in soft / loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable, RCC poles / stays and struts etc. and getting out including trimming sides and forming bottom surface complete all as specified and directed at site.
Returning, filling in including spreading, leveling, watering and well ramming excavated soil in layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays , struts have been erected and tested , all as specified and directed.
Removing excavated surplus soil (Soft / hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed.
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for outdoor termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
M&L for cable jointing kit for 11 KV ( Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 3 core 95 sqmm all as specified and directed by Engr-in-Charge
Supply, install erect in trench vertical position steel tubular seweaged welded poles complete with MS base plate of 6mm thick of size 450 mm x 450 mm finial taper plug pole cap, bolts, nut and screwed, pole made out of ERW MS tubing confirming to IS 2713 Part II of 11 mtr long 410 SP-22 including drilling of holes of required size and nos for fixing of cross arms bracing support / taking out of cables etc, and painting with one coat of red oxide primer and two coat of aluminium paint for exposed surface and two coat of black bituminious paint for the portion embeded in concerete complete all as specified and as directed by Engineer -in-charge.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate for coaping of pole
Plain cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete as specified.
Material and labour for earthing complete with galvanized steel earth plate electrode size 600 x 600 x 6.3 mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanized earth lead 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanized including GI protection pipe light grade 15 mm dia connected to main earth wire on pole or control board and GI pipe light grade 20 mm dia bore for watering funnel with wire mesh. CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing on completion
Dismantling of unserviceable existing cross arms by means made from channels, angles, unserviceable FI clamps, nuts, bolts etc. from OH line and removing complete.
S & F Cross arms ,bracings,supports,clamps and back plate fabricated from structural steel sections including nuts ,bolts, in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide .
S & F Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame out door type suitable for vertical installation single brake provided with locking arrangement, consisting of MS channel ,HT post type insulator ,copper alloy high pressure assembly ,operating rod of GI pipe medium grade confirming to IS-1818 of 1972 ,suitable for 11000 Volt ,400 Amps including dismantling of old one all as specified.
M& L for lightening arrester NON LINEAR TYPE complete with all fittings distribution class discharge capacity 65 kilo Amp, current rating 5 kA suitable for 11000 Volt complete with all fittings.
M & L for drop out fuse assembly for 11 KV, 3 Phase of 100 Amp capacity each pole, consisting of galvanized steel base paper fuse carrying brackets, mounting channel, separating rod complete all as specified including labour for taking down old unserviceable DO unit & removing form all as directed by Engr-in-Charge.
M & L for cable route indicator 100 mm dia, for HT round shaped 10 mm thick with marking of 1.1 KV, HT welded bolted on angle iron 25 x 25 x 5 mm of 60 cm long including PCC in 1:3:6 type C2 of size 15 x 15 x 15 cm embedded in ground including necessary excavation earth work complete all as specified and directed.
Supply, Install, Testing and commissioing of Solar Standalone street light LED 24 W consisting of in built SCC, SPV panel, Low maintenance Lead acid battery , powder coated 5 mtr above ground MS tubular pole with necessary excavation, PCC Foundation and necessary fixing arrangement all as specified and directed.
S&F XLPE insulated, armoured heavy duty electric cable with aluminium cable conductor, 1100 Volts grade, cross sectional area 3.5 core 35 Sqmm
M&L for high density polyethylene pipes (HDPE) of pressure rating 6 kgf / cm2 laid in trenches of size 50 mm suitable for cable protection complete all as specified and directed.
S&F 4 way MCCB powerline vertical DBs in double door suitable for TP / FP MCCB, bus bar with current rating capacity upto 250 A, IP-43-IK09 protection grade complete all as speicified and directed by Engr-in-Charge.
S&F in MCCB TPN 100 Amps, 415 Volts, 25 KA, 4 pole
S&F MCB TPN 415 Volts, 'C' series, breaking capacity 10 KA of rating 63 Amps
S&F in repair for MCB SP 6-32 Amps 'C' series breaking capacity 10 KA of rating
Sub main wiring power / circuit using PVC insulated unsheathed, stranded copper conductor caable 4 x 6 Sqmm + 1 x 6 Sqmm earth continuity conductor to be drawn through and including PVC conduit not less than 32 mm dia medium grade on surface walls / roof / floors complete all as specified and directed. Note : (i) Four wires of 6 Sqmm and one wire of 4 Sqmm and one run of PVC conduit shall be measured as one unit (for 3 phase, supply)
M&L for Water heater storage type, electric supplied and installed complete of capacity 25 ltr all as specified and directed by Engr-in-Charge.
Supply and laid galvanised pipe medium grade complete including fittings ( such as socket, elbow, nipple , union & tee etc) of size 15 mm bore in short length all as specified and directed.
Supply and fix gun metal gate / globe valve with iron wheel head, screwed both ends for iron pipe and fixed of size 15mm dia all as specified and directed.
Supply and fix bib tap, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed to bore of pipe 15 mm dia all as specified and directed.
M&L for Point wiring with PVC insulated unsheathed stranded copper conductor cable of size 2.5 sqmm for one light point controlled by one switch, with PVC unsheathed stranded copper conductor cable of size 2.5 sqmm stranded for earth continuity wire to be drawn in and including PVC medium grade surface casing capping not less than 20 mm width with MS sheet metal sunken switch / terminal box 1.2 mm thick and ebonite switch board cover 3.0 mm thick or PVC moulded switch board and brass screws with cup washers including all necessary wall cutting and making good disturbed surface all as directed and specified. Note : Cutting, chases and making good to match with the adjoining surface shall be included in the unit rate.
S&F Sheet metal enclosure with socket plug top and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240V 25 Amps all as specified and directed.
NOTE : - AMOUNT OF SCHEDULE OF CREDIT Rs. 13,350.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.
Veer Brothers
M/S SANTOSH CONSTRUCTION CO
DURGAI ELECTRICALS
M/S S.N ENTERPRISES
RELIANCE ELECTRONICS
Bidder Name
RELIANCE ELECTRONICS
DURGAI ELECTRICALS
Rama Electricals
M/S SANTOSH CONSTRUCTION CO
M/S S.N ENTERPRISES
Veer Brothers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .