Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC GOVT CONTRACTOR VILL NAYA SUJAN FEROZPUR KALAN TEH DIST PATHANKOT PIN 145023 | PATHANKOT | PATHANKOT | PUNJAB | 145023 | L1 | Accepted-AOC OK | |
| 2 | L2₹13.3 L+₹93,800.05 (7.59%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹13.4 L+₹1.1 L (8.60%)Rejected-Finance M S WALIA TRADING CO VILLAGE VASUDEVPURA NALAGARH ROAD VILLAGE VASUDEVPURA PINJORE HARYANA 134102 | PANCHKULA | HARYANA | 134102 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹13.4 L+₹1.1 L (8.64%)Rejected-Finance | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹14.0 L+₹1.6 L (13.2%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹15.4 L
EMD Value
₹30,800
Closing Date
31 Jul 2020, 6:00 pmClosed
CWE Pathankot
HQ CWE Pathankot
SPECIAL REPAIR TO BLDG NO T-30 T- 43 OF CERTAIN UNIT AT JANGLOTE UNDER GE BASOLI
2020_MES_357983_1
CWE/P-40/2020-21
Open Tender
Civil Works
Item Rate
180 days
JANGLOTE
class E and above Category (a) (I)
9 documents required · 9 mandatory
₹500
Yes
GE Basoli
₹30,800
Yes
19 Sept 2020
3 Jul 2020
3 Aug 2020
3 Jul 2020
31 Jul 2020
17 Jul 2020
Amount
Demolition of cement concrete (un reinforced) in any description and in any position not other wise specifically provided for complete all as specified and directed.
Dismantling of ceiling asbestos cement board any thickness including cover fillites complete all as specified and directed.
Demolition of brick or stone masonry built in cement mortar including all quoins, arches, pillars etc but incl ashlar facing dressed stone work and precast concrete articles all as specified.
Dismantling of AC (Corrugated or Semi Corrugated etc) sheets in roof covering including ridges complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified and directed.
Taking down cement plaster or cement line plaster on stone or brick walls etc including racking out joints, hacking for key scrubbing down with water etc.complete all as specified.
M&L Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240 complete all as specified.
M&L (Plates plain or chequered ) channels square cut or notched (ordinary and counter sunk) forming holes without attachment confirming Fe-290 (Gde-E-165) complete all as specified.
S&F Mild steel screw 5 to 10mm dia machine made, with hexagonal heads at one end and screwed the other, or screwed bolts each screwed and to be fitted with washers and one hexagonal or square nut not 5cm long complete all as specified and directed.
S&F Mild steel screw bolt 16 to 20mm dia machine made, with hexagonal heads at one end and screwed the other, or screwed bolts each screwed and to be fitted with washers and one hexagonal or square nut but bolt exc 15cm & not exc 22.5cm long complete all as specified and directed.
M&L for Cement concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in copings, bands, plinth courses, string courses, lacing courses, kneelers, apex stones, bed plates, including necessary form work complete all as specified.
Fabrication, erection and fixing only (material retrieved under Srl item no 05 shall be reused) rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connected plate confirming to Fe 410W(Gde E-250), quality 'A' complete all as specified.
M & L for pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M & L for pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified.
M&L Brick work with subclass ‘B’ bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as specified
All as per Ser item no 15 here-in before but except bricks
M&L for Plain cement Concrete 1:2:4 type-B0 (using 12.5mm graded aggregate) in roof, kerbs or mud stops, rounded or chamfered on edges complete all as specified.
M & L 15 mm thick rendering in cement Mortar (1:4) on brick concrete surface by using WPC @ 3% by weight of cement and finishing the surfaces even and smooth with using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed
M&L 15mm thick rendering in cement Mortar 1:6 on brick surface in two coats & finishing the surface with sagol finish complete all as specified
M&L 4mm thick non asbestos fibre cement plain bldg boards refixing in same timber freme work with screws in ceiling flat or sloping complete all as specified.
M & L 75mm thick PCC 1:3:6 Type C-1 (using 20mm graded crushed stone aggregates) as in plinth protection finishing the surfaces even & smooth with using extra cement complete all as specified.
M&L for prepration new or previously untreated wooden surface not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paints, over a coat of pink primer complete, all as specified and directed.
M&L for prepration of new plastered surface and applying three coats of white wash on ceiling complete all as specified.
M&L for preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic paint enamel paint over one coat of red oxide primer, complete all as specified.
M&L for preparation of old treated steel surfaces of any description not otherwise described, over 10cm width or girth and applying one coat of synthetic enamel paint , complete all as specified.
M&L prepration new plastered surface and applying two coats of cement base paint complete all as specified.
M&L prepration new plastered surface and applying two coats of OBD over cement based putty on plastered surfaces prepratory to receive distemper on wall paint complete all as specified.
Roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust and including taking out existing roof treatments, brushing neat cement slurry with 3.0 Kg of cement per sqm and rubbish off the materials to a distance n.exc. 100m complete all as specified
M&L for cement Concrete 1:2:4 type-B0 (using 12.5mm graded crushed stone aggregate) 25mm thick in flooring complete all as specified.
Non skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding. 0.38 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade over and including 15mm thick screed bed or bedding layer in cement mortar 1:6, complete all as specified and directed
Non skid ceramic tiles 7 to 8mm thick (square / rectangular) area of each tile exceeding 0.18 Sqm but not exceeding. 0.38 Sqm in skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match shade over and including 10mm thick cement plaster in cement mortar 1:4 complete all as specified and directed
Taking down steel window and ventilator with wire mesh / glazed shutter (without taking of shutter from frame) area not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkhat with shutter (without taking of shutter from frame) area exceeding 1.50 Sqm but not exceeding 4.00 Sqm each complete all as specified and directed.
S&F Plain framed factory made 35mm thick panelled shutter of 2nd class hard wood rail & style (two panel) with lock rail and panel of 9mm BWP commercial plywood or 12 mm veneered particle board with commercial veneering on both faces , the size of rail and style as per IS 1003 (Part-1) kiln seasoned and pressure treated all as specified.
S&F 35mm thick 2nd class hard wood gauzed and skeleton shutters, open rebated and prepared to receive glass, gauge etc (without sash bars), edges of framing plain, chamfered or rounded fitted with cut and mitered beads for securing glass etc. size of members of shutters as specified in SSR Part-I, Section 8, clause 8.20 (a) chowkhat complete, all as specified.
M&L pressed steel frame for doors with one or more rebates including necessary fixing lugs, hinges, lock strike mate etc complete of size 105x60mm frame complete all as specified and directed by Engineer-in-Charge
M & L PCC 1:3:6 type C-1 using 20mm graded crushed stone aggregate as in back filling of chowkhats complete all as specified and directed by Engineer-in-Charge
M&L Box type steel windows and ventilator comprised of tubular frame and shutters made out of 1.25mm thick MS Sheet tube factory made with double side shutters wire gauged shutter & glass glazed shutter (wire cloth and glass panes only shall be measured and paid seperately) with side hung shutters with steel handle and steel peg stay dovetailed or welded incl 2 Nos tower bolts 150mm long for each leaf including other fittings, hinges, handles, tarred hold fasts, PCC blocks etc all as shown on drg No CEPZ/TD-27/13 sheet 1/4 to 4/4 complete all as specified and directed.
S&F Mild steel work as in framed work such as grills and framed guard bars, in window including securing bolts including all necessary drilling, bolting or riveting etc and similar work all as specified and directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.40mm and fixed tinned tacks, or galvanised wire staples etc complete all as specified and directed
S&F sheet glass ordinary quality 3mm thick with oil putty in area not exceeding 0.5 Sqm in each pane complete all as specified and directed
S&F for 150 mm long mild steel tower bolts stove enameled black and bright bolt complete all as specified and directed
Supply and fixing Mild steel sliding door bolts, plate type stove enameled black with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolts plate and two on staple plate, 300mm long, complete all as specified.
S&F mild steel 300 mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed
S&F for 150mm size mild steel pressed handle oval type stove enaelled black complete all as specified and directed
S&F curtain rod 20mm dia of ms powder coated with incl PVC brackets, stops, rollers etc. complete all as specified and directed by Engr-in-Charge
M&L Granite black colour (of any type) 15 to 20mm thick machine cut as in , cooking platforms and like in cement mortar 1:4 incl pointing in white cement (1:2) unsing marble dust with admisture of pigment to match with shade of granite & 20mm thick screed bed or bedding layer of mortar in 1:6 for laying floor finishes including driling hole throughout the depth of slab for gas pipe complete all as specified & directed.
M&L rounding / moulding to edges of stone slabs marblestone, granite stone slabs one edge, such as in steps, cooding platform and othersimilar situations etc complete all as specified & directed.
S&F in position suspended false ceiling system using E-grid suspended ceiing grid system of M/s Saint Gobain. The size of the grid shall be 600x600mm with GI framework main runner 38x24mm cross tee 25x24 mm and wall angle 24x24mm using 9mm thick ceiling panel laminated with PVC film on front face and foil back available in due drop texture as per IS-2095 Part-I 1996 fixed in the grid of the E-grid suspended ceiling system duly suspended by 4mm dig GI bar hangers from the purlins of the roof with butterfly clips using including prepration of the surfaces and applying two coats of synthetic enamel paint over a coat of primer complete as specified and directed.
Surface excavation in any type of soil not exceeding 30cm deep and avg 15cm in foul condition to remove heaps of waste , cleaning flora & fauna , follage and bushes around septic tank , soakage well and manholes and removing debrises/heaps of bushes /vegetation etc from the vicinity and depositing at a place complete as specified and directed.
M & L 75mm thick PCC 1:4:8 type D-2 (using 40mm graded crushed stone aggregate) as in sub base finished even and smooth complete all as specified and directed
M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed
M&L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 60mm thickness M-35 Grade, pointed with grey cement and pigments, complete all as specified and directed by Engr-in-Charge.
M&L for Chequered cement concrete tiles 200 x200 x 25mm thick, set jointed and pointed in neat cement slurry in floors with grey cement and pigment complete all as specified and directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power socket and bulk head fittings) complete including fixture and fittings such as switches, ceiling roses, pandents holder , regulators, sockets, lamp holder, buzzer , light fittings etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of wall, floors, complete all as specified and directed.
M & L Point wiring for light/fan point controlled by one switch with 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel sunkum boxes having thickness as specified 3mm bakalite laminated sheet for switches and sockets, including 1.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green) (b) On RCC roof ceiling PVC conduit shall be provided on surface for fan with proper fixing clips all as directed.
All as per Srl item No 57 but for one 3 pin 5 Amp socket outlet on independent board.
All as per Srl item No 57 but for one 3 pin 5 Amp socket outlet on same board.
M&L Point wiring with 2.5 sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS with and including PVC rigid conduit (medium grade) having thickness as per IS code with all fittings including galvanised pressed steel sunkum boxes having thickness as specified 3mm bakalite laminated sheet for one 3 pin socket outlet 15 Amp on independent board including 2.5sqmm single core PVC insulated unsheathed multistranded copper conductor FRLS as earth continuity conductor connected to common earth dolly including cutting, chiseling for concealed piping and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specfied and directed. Note : (a) Colour coding is to be maintained (Ph-Red, N-Black, Half -Yellow, Earth- Green)
M&L Switch piano flush type 5 Amp 230 Volts single pole one way, (ISI marked), complete all as specified.
S&F Socket outlet 2 & 3 pin 5 Amp flush type 230 Volts, complete all as specified & directed.
S&F in Socket outlet 2 in 1, 3 pin 5 & 15 Amp AC 240 Volts, complete all as specified & directed.
S&F Switch socket combination 2 in 1, 6 Pin 5 and 15 Amps flush type universal complete all as specified and directed.
S & F electronic fan regulator socket type in 4 steps speed 100 Watt (rotary type) control complete all as specified.
S&F Lamp holder PVC/Polycarbonate type with back plate having matching colour to holder for angle/batten fittings (ISI marked) complete all as specified and directed.
S & F Ceiling rose, surface bakelite two or three terminals isolated body (ISI marked) fixed on PVC round block complete all as specified.
S&F in replacement LED tube light fitting made out of CRCA sheet, 1x20w AC 230v, including LED (tube rod), LED drivers, bipin holders, 4 feet long complete with all accessories pre-wired and including connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core complete all as specified. Note: (i) Contractor shall produce LM 79 test report form third party (instead of company inhouse lab) NABL/UL accredited laboratory. (ii) LM-80 report from LED manufacturer. (iii) Test certificates to be submitted before commencement of work/claiming for payment. (iv) Warranty certificate for minimum 02 years to be submitted from OEM.
S&F in replacement LED bulkhead fittings luminaries with opal diffuser including (LED lamp type 10 W LED 6000 K ), lamp holder etc complete all as specified.
S&F Sheet metal enclosure powder coated Double door SPN 8 way provision for one No incoming MCB DP and outgoing MCBs SP, AC 230 Volt, 50 HZ AC supply having protection IP43, IK-09 with copper bus bar rated 200 amps, neutral link, earth bar complete all as specified.
S&F MCB SPN 32 Amps, AC 230 Volts, 10 KA breaking capacity of 'C' series all as specified
S & F in replacement MCB single pole (SP) 6 to 32 Amps with 10 KA breaking capacity , of 'C' series in distribution boards all as specified.
M & L for submain wiring with two single core PVC insulated flexible copper conductor cable of size 6 sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6 Sqmm as earth lead in & including concealed PVC conduit light grade cutting chases to walls for laying conduit and making good the disturbed wall surfaces to match with existing specification all as required at site. Note: (a) Two runs of 6 Sqmm single core PVC insulated copper conductor cable(FRLS) and one run of 6 sqmm copper conductor cable (FRLS) as a earth lead and one run of PVC conduit will be measured as a one unit. b) Rates are deemed to be chases of conduit and sinking for boxes cutting and making holes in wall/floor for passing in or through conduit
M&L Earthing complete with galvanized steel earth plate electrode 600cmx600cmx6 mm thick buried directly in ground (Earth pit not less than 2.25 Mtr deep below normal ground level )with top edge of the plate not less than 1.5 Mtr below normal ground level connecting with galvanized iron GI earth wire 4mm dia by means of bolt nut check nuts and washers of galvanized iron and provision of GI tubing medium grade (ISI marked)of size 15mm for protection of GI earth wire upto test point, 20mm dia GI medium grade watering pipe, 15mm boree light grade earth lead protection pipe upto main board, funnel with wiremesh, 400mm thick RCC 1:2:4 type B1 using 20mm graded crushed stone aggregate reinforced with suitable handle and angle iron frame and necessary excavation and earth work in any type of soil etc. complete all as specified and as directed including testing on completion.
S&F ceiling fan 1200mm sweep AC 230 Volts 50 Hz, BEE 5 star rated BLDC having nominal suitable capacity complete with accessories such as down rod, canopy, copper wound electric motor, aluminium wings, clamps, rubber reel etc complete all as specified.
Supply laying and testing LT XLPE insulated, screened, PVC bedded galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts graded with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified.
S&F DWC high density polyethelene pipes having dia 63/50 mm, outer dia, inner as per site requirement having corrugation on the wall and plain surface on the inner wall conforming to IS: 14930(Part I & II) for protection of underground cable laid along pole/along wall/in PCC on GL/roof and including all fittings as required at site complete all as specified and directed.
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in deep for foundation of pole/stay and laying of UG cable and getting out in any type of complete all as specified.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm, in any type of soil, complete all as specified and as directed.
Removal of excavated material (soil) to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point complete all as specified and directed
Notes : The Schedule of Credit amount shall be deducted from the total of this schedule(BoQ) to arrive at Contract Sum.
MANOTRA BUILDER
Walia trading co
Ms Dalip Kumar and Co.
Standard engineers
Ms International Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .