| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹15.3 LAccepted-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L-1 | Accepted-Finance LOWEST TENDERER | |
| 2 | L2₹17.3 L+₹2.0 L (13.0%)Rejected-Finance BHAIRAVNATH NAGAR AT KUSGAON POST LONAVLA 410 401 DISTT PUNE | PUNE | MAHARASHTRA | 410401 | L2 | Rejected-Finance GREATER THAN L1 | |
| 3 | L-3₹17.8 L+₹2.4 L (15.9%)Rejected-Finance 601 A WING SAI PARAMOUNT APARTMENT SHRADDHA VIHAR COLONY INDIRANAGAR NASHIK NASHIK MAHARASHTRA 422009 | NASHIK | MAHARASHTRA | 422009 | L-3 | Rejected-Finance GREATER THAN L1 | |
| 4 | L4₹19.1 L+₹3.7 L (24.3%)Rejected-Finance GARDEN AVENUE PLOT NO 242 243 244 RH 4 SECTOR 21 NERUL NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L4 | Rejected-Finance GREATER THAN L1 | |
| 5 | L-5₹19.4 L+₹4.0 L (26.2%)Rejected-Finance | L-5 | Rejected-Finance GREATER THAN L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Sept 2020, 6:00 pmClosed
Maj Komal Parihar
GE (I) (NAVY), INS SHIVAJI - POST, LONAVLA -410402
REPAIRS TO ROOF OF CERTAIN BLDGS OF MANGLORE TILES CGI SHEETS, GALVALUME SHEET AND FALSE CEILING UNDER AGE BRI AT INS SHIVAJI LONAVLA
2020_MES_369495_1
GE/LONAVLA/8928/E8
Open Tender
Civil Works
Item Rate
270 days
GE (I) (NAVY) LONAVLA
As per NIT /Tender documents
4 documents required · 4 mandatory
₹500
Yes
GEINDEPNAVYLONAVLA
₹50,000
Yes
7 Sept 2020
14 Aug 2020
5 Sept 2020
14 Aug 2020
3 Sept 2020
21 Aug 2020
15 Aug 2020 - 20 Aug 2020
Amount
Dismantling mangalore pattern roofing tiles single layer laid dry.
Dismantling mangalore pattern roofing tiles single layer including ridge tiles laid, bedded in cement mortar etc complete all as specified and as directed.
Dismantling battens for tiles any size spacing exceeding 15 cm centres .
Dismantling wooden fillets as in rafter, purlin etc unframed work.
Dismantling timber scantlings 40 sq. cm and over in section, in any position Framed trusses nd purlins
Dismantling boarding any description fixed in any position fixed in the nails.
Dismantling of CGI/PGI /TCT sheet in roofing any gauge and any thickness including ridge, valley/gutter etc.
Taking down asbestos cement (corrugated ,semicorrigated ,etc.) sheets in roof covering.
M&L mangalore pattern roof tiles inter locking at side joints laid dry.(class AA tile)
All as per item No.9 above but fixing only roof tiles obtained from dismantling.
M&L ridge or hip tiles to suit mangalore pattern roofing tiles bedded and jointed in CM 1:6 using class AA tiles.
All as per item No 11 above but fixing only ridge or hip tiles obtained from dismantling.
M/L 2nd class hard wood battens sectional area exc 5 sqcm and n.exc 15 sqcm clean sawn @ 30cm spacing all as directed.
All as per item 13 above but fixing only batterns obtained from dismantling.
M&L 2nd class hard wood scantlings square or rectangular in section Exc 13 & N.exc 25 Sqcm clean sawn of size 50mmx50 mm used as rafter and purlin and fixed to CGI Sheet with selftapping screws all as directed.
All as per item 15 above but fixing only scantlings obtained from dismantling.
S&F 20mm thick 2nd class hard wood boarding fixed with nails planed one side with butt joints.
All as per item No 17 above but fixing only obtained from dismantling.
M&L for Second class hard-wood Clean sawn in scantlings in timber framed for rafter and purlin in roof
S/F CGI sheeting with two corrugation side lap fixed with 'L' or 'J' type hook in roof 0.63mm thick class IV make (JINDAL)
All as per item No 20 above but fixing only CGI sheet any thickness obtained from dismantling.
S/F plain galvanised steel sheeting as in ridge laps valley gutter 0.63mm thick class IV al as specified.
Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
S&F Pre painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
M&L filleting in CM 1:4 in any shape sectional area n.exc 25 sqcm in repair
Dismantling structural steel work including doors, gates but excluding framed truss etc.
S&F steel work in Tubular trusses, vertical post connecting to plates, including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1998 grade St-240 complete
S&F Rolled mild steel section in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc quality conforming to Fe 410-W (Gde E250) quality-A.
S&F wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 290 Gde E-165
Dismantling Wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets/Aluminium snap grid
M&L for powder coated aluminium snap grid frame work for false ceiling, with aluminium angle 25mmx25mmx1.5mm fixed to perimeter of wall, Main 'T' runner 38mmx25mmx1.5mm and secondary/cross 'T' runner 25mmx25mmx1.5mm to be interlocked in such a way that the size of grid shall be 605mmx 605mm including 6mm dia GI hangers (upto 1200mm length) adjusting level fixed to roof by means of ceiling cleats made out of GI flat 40x3mm, 60mm long and expansion hold fastners 12.5mm dia, 40mm long complete all as specified and as directed. Note:- The thickness of the powder coating shall not be less than 0.5 micron & the tint shall be as decided by GE.
S&F 4 mm thick Non Asbestos (E-board) designer tiles (Electra) suitably fixed in false ceiling grid /frame with staples or screws complete all as specified and as directed.
Demolition of PCC/Padding concrete of any type
M&L for PCC 1:2:4 type B0 (12.5mm graded agg) as in roof kerbs coving over chajjas and similar locations rounded or chamfered on edges.
Dismantling of existing water proofing treatment treatment consisting of cement mortar, concrete tarfelt and foreign materials etc incl cleaning the surface and removal of dismantled materials outside MD land complete all as specified and as directed.
M&L rendering 15mm thick in cement mortar (1:4) as in roof using water proofing compound including necessary scaffolding etc complete all as specified and as directed. Note: Water proofing compound will be measured and paid separately.
M&L for water proofing treatment to RCC roof slab all as specified below and as directed:- (a) Apply one coat of bituminous primer @ 0.25 Kg/Sqm. (b) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (c) Laying APP polymer modified membrane 4mm thick with non woven polyster reniforcement weighing not less than 4.00 Kg/Sqm applied by torch application method. (d) Apply a coat of blown type bitumen grade 85/25 heated to working temperature of 180 degree centigrade and applied at 1.20 Kg/Sqm of the surface area. (e) Apply a coat of solar reflective bituminous aluminium paint @ 0.10 Kg/Sqm.
Supply integral water proofing compound.
M&L for cutting ,grooves or rebates n.exc 15cm girth and triming surface for inserting pre-painted galvatume sheet with or without reinforcement.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.
Demolition of Brickwork or stone/bou-lder masonry, built in Cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles
M&L for Brickwork with sub class B' bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 in narrow widths including Cutting out bricks/stone, forming toothing for, and bonding new into old brickwork /stone masonry
M&L for rendering 15mm thick in cement mortar 1:6 on brick work or concrete surfaces and finished even and smooth without using extra cement on walls
M&L for rendering 15mm thick in cement mortar 1:4 on brick work or concrete surfaces and finished even and smooth without using extra cement on walls
Preparing new surfaces, plastered or unplastered surfaces of walls and applying three coats of white washing
M&L for Preparing new plastered surface and applying 2 coats of Apex paint on walls over a coat of primer
M&L for preparation of old plastered surfaces of wallsand applying one coat of white wash on the walls, pillars, cornices etc complete all as specified and directed.
M&L preparing new surfaces of wooden tiles batterns of any thickness and spacing and applying two coat of creoste oil all as specified.
--- do --- as above but with one coat on old surface
Preparation of new wooden surface of girth exceeding 10cm and applying two coats of synthetic enamel paint over a coat of primer.
Preparation of old timber surface of girth exceeding 10cm and applying two coats of synthetic enamel paint complete
Preparing new steel Surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of Synthetic enamel paint over a coat of red oxide
Preparing old steel Surfaces of any des-cription, over 10cm in width or grith, not otherwise described and applying two coats of Synthetic enamel paint complete.
Demolition and breaking up PVC Rain water Carrying pipes fixed to roof and walls including all fittings such as couplers, bends, elbows clamps, brackets etc
S&F PVC SWR rainwater gutter pipes half round section 140 mm nominal diameter with couplers fixed to roof with pipe clamps and top brackets all as per manufacturer specification and instructions and directed by Engineer in charge
S&F PVC (SWR) pipes of dia 110mm bore single socketed in any length with rubber ring joints fixed to walls.
S&F PVC SWR elbows half round section 140 mm nominal diameter fixed to rainwater gutters pipes all as per manufacturer specification and instructions and directed by Engineer in charge
S&F PVC (SWR) bends of 110 mm dia bore
S&F Mild steel work in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay): heavy, for large gates: hook and pintle hinges; large hasp staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to trusses or rafters ; knee pieces inserts ; two way and three way straps' plate washers and similar small articles conforming to Fe-290, Gde-E-165
seema enterprises
SAI SAMARTH ENTERPRISES
M/s S.D Construction Co
RK AND SONS CREATION
United Engineers and Contractors
SHAILENDRA B TULSANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .