| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 LAccepted-AOC 1ST FLOOR SIDHARTH TOWER BALTI KHARKHANA BYELNE S J ROAD ATHGAON GUWAHATI KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | L1 | Accepted-AOC Being L1 bid. | |
| 2 | L2₹39.7 L+₹1.8 L (4.73%)Rejected-Finance VILL GHARGA PO DWARNARI DIST PURBA BARDHAMAN PIN 713403 WB | PURBA BARDHAMAN | WEST BENGAL | 713403 | L2 | Rejected-Finance BEING L2 BID | |
| 3 | L3₹42.5 L+₹4.6 L (12.1%)Rejected-Finance VILL SANDIPUR PO DWARNARY DISTT PURBA MEDINIPUR KOLKATA 7134403 WB | KOLKATA | PURBA MEDINIPUR | WB | 7134403 | L3 | Rejected-Finance BEING L3 BID |
Tender Value
₹39 L
EMD Value
₹78,000
Closing Date
28 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) (CGN) KOLKATA
GE (I) (Coast Guard Navy) Military Engineer Services Damodar Complex Naval Transit Accommodation Hastings, Kolkata700 023
PROVN OF BOREWELL AT FRAZERGUNJ UNDER GE (I) (CGN) KOLKATA
2023_MES_612009_1
NIT No 8701/35/2023-2024/04/E8
Open Tender
Water Equipments/ Meter/ Drilling/ Boring
Item Rate
180 days
FRAZERGUNJ
CLASS D AND CATEGORY a(ii)
8 documents required · 8 mandatory
₹500
GE (I) (CGN) Kolkata
₹78,000
Yes
26 Sept 2023
3 Aug 2023
29 Aug 2023
3 Aug 2023
28 Aug 2023
14 Aug 2023
Amount
Mobilisation of accessories /tools/ plants /equipment as per IS 2800 (Part 1) 1994 for construction of borewell of 450-500 mm dia bore hole using Rotary Drilling Method (Direct Circulation Method) with all minor accessories at site complete all as specified and directed. Note: The quoted rate shall be inclusive of shifting the accessories/ tools/ plants/ equipment from one site to other for subsequent boring.
Drilling pilot bore hole of 450-500 mm dia by Rotary/ Reverse rotry Drilling Method (Direct Circulation Method) as described in IS: 2800 (Part I): 1991 in any kind of soil strata including hard stone/boulder upto 300 metre depth below ground level, including compound/ powder like valmite, bentonite solution, local silty clay etc. to be required as per the site condition including collecting samples from different strata, preparing and submitting strata chart/ bore log all complete all as specified and directed.
Resistivity variation studies in bore hole drilled by electric logging of pilot bores by expert of Geology division to know the potential and temperature probes of drinking water by approved agency duly collaborated with strata chart/bore log, submitting of Report including its interpretation by a qualified Hydrologist/ground water expert complete all as specified and as directed.
Material and labour for conducting test on Tube well for yield after developing including draw down test, vertically test, aquifers performance test including arrangement for all T&P required for testing complete all as specified and directed.
Supply, assembling, lowering and fixing in position 200 mm nominal dia (8 inch) PVC-U type, casing pipe confirming to IS 12818 : 2010, CD type, K value gretter than 64, with wall thickness 14.80 mm having male threads at spigot end and female threads at socket end fixed with sealing rings of EPDM material complete all as specified and directed.
Supply, assembling, lowering and fixing in position 150 mm nominal dia (6 inch) PVC-U type, casing pipe confirming to IS 12818 : 2010, CD type, K value gretter than 64, with wall thickness 10.70 mm having male threads at spigot end and female threads at socket end fixed with sealing rings of EPDM material complete all as specified and directed.
Supply, assembling, lowering and fixing in position 150 mm nominal dia (6 inch) PVC-U type, ribbed screen pipe confirming to IS 12818 : 2010, RMS type, K value gretter than 64, with wall thickness 8.50 mm, ribs shall be 2.5 ribs/cm, having male threads at spigot end and female threads at socket end fixed with sealing rings of EPDM material complete all as specified and directed.
S&F mild steel bail plug assembly suitable for 150 mm bore casing pipe internal threaded with strong iron hook, screwed and welded to casing pipe as per IS 2800 complete all as specified and directed.
Supply and fixing PVC Nipple 200 mm dia 1 feet long fitted to casing pipe complete all as specified and directed.
Supply and fixing PVC reducer suitable for (200 x 150 mm ) bore casing pipe, 10 mm thick, fitted to casing pipe as per IS 2800 by means of electric welding complete all as specified and directed.
S & F mild steel housing clamp of 200 mm long 100 mm wide made out of 20 mm thick thick MS plate made of shape for 200 mm bore casing pipe including necessary bolts & nuts of required size complete all as specified and as directed.
S & F mild steel centre guide pati set of 150 mm wide made of 20 mm thick MS plate made of shape for 150 mm bore casing pipe including necessary bolts & nuts of required size complete all as specified and as directed.
Supplying, designing, packing gravel (hard, insoluble and roughly rounded) of particle size ranges (2 mm to 3.35 mm, 3.35 mm to 4.75 mm, 4.75 mm to 6.3 mm, 6.3 mm to 8 mm, 8 mm to 12.5 mm) to the tube well in accordance with IS: 4097 as per the site requirement complete all as specified and as directed.
Material and labour for disinfection of bore well as per IS 2800 (Part 2): 1991 using 200 milligrams of powdered chlorine compound per litre of water present in the well and left in the well for at least 8-12 hours to ensure elimination of any bacteria complete all as specified and as directed.
Developing of tube well by means of compressed air with diesel engine operated air compressor for each till free flow of water in well is obtained and till sand free clear potable water with sand content upto 10 PPM is obtained and yield not less than 50000 LPH is obtained and tested for following duration to get maximum yield and discharge including supply of yield test result complete all as specified and directed. Note : Above rate is inclusive of DHPP and all necessary Tool and Plant.
Carrying out testing of water sample of untreated water for all parameters mentioned in Table 1 to Table 6 of IS 10500: 2012 from any govt approved Lab as approved by the GE complete all as specified and as directed.
S&F pressure gauge 0-14 Kgs rating with isolation cock suitable for a working pressure of 7 Kg/cm² (Liquid based High Intensity) complete all as specified and directed.
Supply and laying or fixing or passing through pipe flat PVC insulated PVC sheathed copper couductor stranded submersible cable cores 1100 volt grade 6 Sqmm 3 core including jointing material and connection work complete all as specified and as directed.
Supply lowering and fixing PVC column pipe of 80 mm dia bore, heavy grade (including CI adapter, Nipple, Elbow, Flanges and other fittings) confirming to IS, both end sockets, complete all as specified and directed.
Material and labour for PCC (1:2:4) type B1 using 20 mm graded stone aggregate, for construction of platform of size 1.00m x 1.00m x 0.60m (0.30 M below normal ground level and 0.3 M above ground level) with drain out arrangement including necessary excavation, returning filling, removing of surplus soil and form work for Tube well casing pipe all as specified and directed at site.
Supply, installation, testing and commissioning, lowering of submersible pump, electric driven 415 V, TP Star delta suitable for (Casing pipe size 200 mm), head range 65-74 Mtr, upto 10 HP discharge 4000 LPH complete all as specified and directed.
Supply and fixing GI water tubing 80 mm bore, medium grade with all fittings (such as bends, elbows, tees, short plugs and union etc.) and laid in trenches complete all as specified and as directed.
Supply and fixing non return valve PN-1.6 size of 80 mm dia both ends flanged heavy duty, including jointing materials, nut bolts washer etc and testing complete all as directed.
Supply and fixed 80 mm bore seated valve PN – 1.6 IS 14846-2000 with Spindle Iron (Heavy duty) Wheel head and both ends flanged and MS nut bolts and washers and pair of rubber/fiber gasket and fixed in position complete all as directed.
M&L for Construction of brick masonry chamber with subclass B bricks in CM (1:6) with PCC 1:4:8 type B2 for foundation of internal dimension of 90x90x60cm including 15mm thick plastering in CM (1:4) inside the chamber and on the external portion of exposed above ground level including 3mm thick MS cover welded around with MS flat iron of size 40x6mm including MS angle iron frame of size 40x40x6mm with locking arrangement including painting of two coats of syntetic enemel paint over a coat of red oxide primer including necessary earth work in soft/ loose soil, well ramming of soil around the constructed chamber complete all as specified and directed.
Excavation in trenches n exc 1.50m wide n exc 1.50m deep and getting out ant type (loose soil) of soil complete all as specified and as directed.
Returning filling including spreading levelling, watering and well ramming in layers n exc 25cm thick complete all as specified and as directed.
Removing excavated material n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and as directed.
Supply & spreading in trenches dry river sand cushioning to underground cable in trenches including spreading, levelling hand punning down complete all as specified and directed Note:- Depth of sand cushioning will be measured after punning down and levelling the sand properly.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 with peak, size 250mm x 150mm x 40mm along length of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed
Supply, laying and testing of cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 1100 Volts grade, cross sectional area 25 Sqmm 3.5 core complete all as specified and directed by Engr-in Charge.
Desige, supply, install, testing and commissioning outdoor cubical type made of Polycarbonate CPRI approved dust and vermin proof factory made LT panel board outdoor type, dust vermine and water proof suitable for 415 Volt,50 Hz, FRP (shock proof, rust free, corrosion free, acid and chemical resistant, fire retardant, having high impact, made of halogen and silica free recyclable material), UV resistant, having high grade gasket made of Polyurethane, should withstand glow wire test at 9600c, should be flame retardant, for avoiding condensation or formation of water droplets inside the feeder pillar.. The locking system will be spring loaded. For that moisture absorbent material made of synthetic rubber, super absorbent polymer and nonwoven fabric which should have absorbency of 0.8g (H2O)/1g (product) @ 25deg C and 95% RH or Higher. the feeder pillar panel should hold Type Test certificates (CPRI) with switchgear assemblies as per IEC60 439-1, with 4 wire system with 250 Amp capacity copper bus bar with suitable size of Copper strip for internal links, thimbles gland including PCC foundation (PCC 1:3:6 type C-2) and supply & comprising of the following including internal pre-wiring complete:- (i) Incomming MCCB 160 Amp, 4Pole, 35KA - 1No (ii) Out going MCCB 63 Amp, 3 pole, 25KA - 1No (iii) MCCB 40 Amp, 3 poole 16 KA- 4 Nos (iv) Fully Automatic Star delta Starter In PVC sheet Enclosure Type MN Motor rating AC-3,Duty 415v, 50 Hz 3 Phase to 15 HP,Relay range of 10-63 A.- for bore well - 01 Nos (v) DOL Starter for 3 HP Water pumps- 2Nos (vi) The panel should have under voltage and over voltage protection including single phase protection, (vii)) LED indication lamps for RYB- 1 set, (viii) Digital multifunction meter for 415V, 3 phase, 4 wire, 50 Hz AC system. (ix) Digital Voltmeter 0-500 Volts - 1No (x) Digital Ammeter 0-200 AMp with CT coil- 1No
Supply, installation, commissioning and testing of GRP Panel tank of 25000 litre capacity as per the description given below, inclusive of connection with nuts and bolts :- (i) Tensile strength (Mpa)≥60 (ii) Bending strength (Mpa)≥100 (iii) Glass fiber content,%≥25 (iv) Standard panel is typically 1000 x 1000mm, 1000 x 500mm, 1000 x 1500mm. 2000X1000mm. The contractor has to assemble the tank for the required capacity as mentioned above so that the tank can be placed and accommodated. (iv) The bolts, nuts and other fasteners that hold the GRP tank together shall be hot-dip galvanized. (v) The internal and roof bolts shall be of grade 304 stainless steel (vi) The sealant for sealing the joint shall be high density, non-toxic PVC foam (vii) Tank Support/ Skid Base i.e. The beams and framework shall be hot dip- galvanized (viii) Ladder :- The external ladder shal be hot-dip galvanized steel pipe while the internal ladder shall be made of standard 304 stainless steel pipe or hot- dip galvanized steel pipe. (ix) There should not be any metal components in the internal structure including necessary civil work as per manufacturer recommendations including all inlet outlet vent and overflow connections and fixing of open well submersible pumps etc of complete all as specified and as directed.
Supply, installation, testing and commissioning of monoblock pump, 3 HP, 3 Phase 415 Volts, suitable for installation in small capacity UG sumps, heavy duty with stainless steel frame body and SS impellers, pump capable of delivering 7200 litters per hour at 36 Meters of head of water with heavy duty galvanised nuts, bolts and washers etc complete all as specified and as directed. (For water pumping to overhead/ service tank)
Supply and install Altoch dosing system item no 153120, item type C, Model-ADS-PRO of Declibac specification:- multi cavity water sanitiser /conditioning station with proportional dosing arrangement at zero discharge of following specification:MOC: Non mettalic maximum temperature 45 degree C operation :power free automatic dosing pattern, proportional capacity 100liters-200 liters, compatibility Stequa 411 AE refill/prefill total refill.tank lid must have provision for mounting dosing pump on the lid wass . cavity are complete with lids. Attachements: a) Overflow valve b) Water inlet valve c) Outlet valve (for offline/ automatic gravity flow), drain d) Level controller, e) Detachable grouting base with rubber buffer valve complete all as specified and as directed by Eng-in-charge. Make:- Declibac technologies Pvt Ltd/ Potter and watts/ Brio zing Note:-i) Rate quoted by contractor inclusive of all arrangement required for functioning of dosing system including fixing arrangement all as specified and directed by Eng-in-Charge
Supply, only Item No S411AE, item type C, Item name STEQUA411 AE refill, of Declibac Specification:- Chlorine tablets contained in plastic cylindrical sealed disposable sanitiser refill for disinfection of drinking water with arrangements of controlled release of disinfectant in wate, suitable for operation through recommended dosing system. Replacement indication- visual and weight variation operation type -non contact, non inhalatory, heavy metal contaminants (like Hg and Pb) in product media must be below detection limit(BDL) and product must pass through acute toxicity test, based on which the product must be considered safe to use from human health safety point of view. when use in recommended dosage, all as specified and as directed by Eng-in-charge
Material and labour for Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 25 X 4 mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Supply, installation and testing water meter with encloser and water resistant IP 65 as Bulk Enclosed Type, Mettalic Gears, C.I. Body, IS:2373, Flanged Ends, Class A Water meter of 80 mm dia with existing water pipe line complete all as specified and directed.
HIGH HILLS ENTERPRISE
UNIVERSAL TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .