Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | l1₹24.4 LAccepted-AOC | l1 | Accepted-AOC Being L1 Bidder | |
| 2 | l2₹26.7 L+₹1.3 L (4.92%)Rejected-Finance | l2 | Rejected-Finance not being L1 bidder | |
| 3 | l3₹27.1 L+₹1.6 L (6.31%)Rejected-Finance 24 25 MANGAL ARCADE TELCO ROAD OPP HOTEL DOUBLE TREE MOHAN NAGAR CHINCHWAD PUNE 411019 | PUNE | MAHARASHTRA | 411019 | l3 | Rejected-Finance not being L1 bidder | |
| 4 | l4₹31.3 L+₹5.8 L (22.7%)Rejected-Finance THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | l4 | Rejected-Finance not being L1 bidder | |
| 5 | l5₹32.6 L+₹7.1 L (28.0%)Rejected-Finance | l5 | Rejected-Finance not being L1 bidder |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
28 Oct 2022, 6:00 pmClosed
CWE No 2 Secunderabad
CWE No 2 Secunderabad, Mudfort, MES Complex, Secunderabad-03
REPAIR REPLACEMENT OF LT FEEDER PILLAR BOXES, APFC PANELS, LT HT CABLE, CABLE JOINTS, LT POLES, SERVICE CONNECTIONS AND OTHER CONNECT ACCESSORIES ABNS AND ABOS AREA UNDER GE BELGAUM
2022_MES_553888_1
81116/E8
Open Tender
Civil Works
Item Rate
180 days
GE Belgaum
As per Tender Documents
7 documents required · 7 mandatory
₹500
GE Belgaum
₹70,000
Yes
30 Nov 2022
23 Sept 2022
4 Nov 2022
23 Sept 2022
28 Oct 2022
14 Oct 2022
Amount
M&L for laying in trenches or fixing in walls/poles/under trenches or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 sq mm, 3.5 core including testing the same after laid and jointed including Taking out / dismantling existing old u/s service LT UG cables of any size and any run and making good the disturbed surface all as specified and as directed. Note:- Excavation and earth work, pipe/ cable protection will be measured and paid separetely.
All as per item No. 1 but cable size 185 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 150 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 120 sq mm 3.5 core all as specified and as directed.
All as per item No.1 but cable size 95 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 70 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 50 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 35 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 25 sq mm 3.5 core all as specified and as directed.
All as per item No. 1 but cable size 16 sq mm 4 core all as specified and as directed.
All as per item No. 1 but cable size 10 sq mm 4 core all as specified and as directed.
All as per item No. 1 but cable size 10 sq mm 2 core all as specified and as directed.
Supply and laying in trenches or fixing in walls/poles/under treanches or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq mm, 3 core including testing after laid and jointed including Dismantling existing old u/s service HT UG cables of any run any size & making good the disturbed surface all as specified and as directed. Note:- Excavation and earth work pipe/ cable protection shall be measured and paid separetely.
All as per item No. 13 but cable size 120 sq mm 3 core all as specified and as directed.
All as per item No. 13 but cable size 95 sq mm 3 core all as specified and as directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m depth and getting out in Soft/loose soil for laying cables, pipes, pole foundation etc. all as specified and as directed.
Excavating in trenches n exc 1.5m wide and n exc 1.5m depth and getting out in hard/dense soil for laying cables, pipes, pole foundation etc. all as specified and directed.
Returning , filling in including spreading , levelling , watering , and well ramming in layers not exc, 25 cm in soft / loose soil complete all as specified and as directed .
Removing excavated material not exc 50 m & depositing where directed at a level n exc 1.5 m above the starting point. all as specified and as directed.
M&L for plain Cement concrete 1:2:4 type B2 using 20 mm graded stone aggregate for filling of road cuttings areas complete all as specified and as directed
S & F GI tube light grade 40 mm bore fixed in walls or laid in floors / trench complete all as specified and directed with MS clamp and nut bolts and washers etc taking down old GI tubing along with all fixing accessories all as specified and as directed.
S & F GI tube light grade 80 mm bore laid in trenches / road / drain / fixed to wall complete all as specified and directed with MS clamp and nut bolts and washers etc, as required including taking down old GI tubing along with all fixing accessories all as specified and as directed.
S & F GI tube light grade 100 mm bore laid in trenches / road / drain / fixed to wall complete all as specified and directed with MS clamp and nut bolts and washers etc, as requied including taking down old GI tubing along with all fixing accessories all as specified and as directed.
S&F Double wall corrugated high density polymer ethyl pipe of size 63 mm outer dia with ISI marked (IS 14930- 2001 ), laid in trenches /floors & fixed on wall/ pole with & including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables, complete all as specified and as directed. Make - Duraline, Rex, Tirupati, Tijaria,Ketron.
S&F Double wall corrugated high density polymer ethyl pipe of size 120 mm outer dia with ISI marked (IS 14930- 2001 ), laid in trenches /floors & fixed on wall/ pole with & including necessary fittings such as bends, sockets & other connected accessories etc for laying of electric cables, complete all as specified and as directed. Make - Duraline, Rex, Tirupati, Tijaria,Ketron.
S&F as in repairs LT Panel Outdoor type floor mounted free standing dust and vermin proof panel / DB with IP-55 protection, CPRI approved, frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, including Separate cubicle chamber with cable alley not less than 300mm width for installation/connecting switchgears with the main bus bar using aluminium bus link or copper conductor flexible wires suitable for switch rating and connecting outgoing terminals of the switchgear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, panel having front and rear opening and provision for installation of separate cable alleys, bus bar chamber and switchgear compartments, Provision in cable alleys for bottom cable entry for incoming & outgoing cables, affixing MV danger plate at suitable intervals / locations including erection, testing and commissioning complete all as specified and directed including the following fixtures amd fitments mentioned below
Outgoing:- Separate cubical chamber with a cable alley not less than 300 mm width for installation/connecting the following switch gear with the main bus bar using aluminium bus link or copper conductor flexible wires suitable to the switch rating and connecting outgoing terminals of the switch gear with terminal blocks of appropriate current rating using flexible copper wires duly terminated by cable lugs and thimbles. (MCCB should be with adjustable thermal and adjustable magnetic setting)¬ (i)MCCB, 4 pole 200 A, 36 KA -02 No g) (ii) MCCB, 4 pole 160 A, 25 KA -02 No (iii)MCCB, 4 pole 100 A, 25 KA -03 No (i)MCCB, 4 pole 63 A, 36 KA -03 No Make of MCCB: Havells/HPL/Standard/Legrand / Seimens / Schneider / ABB Note:- (i) A clear space of 20mm shall be kept from floor level for switchgear compartment. (ii) Air ventilation breathers with exhaust fan plastic body 100mm sweep shall be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. (iii) Each compartment shall be numbered/lettered as per the approved by GE. . (iv) Contractor shall submit the GA drawings of LT Panel for approval of GE before placing the bulk order.
Supplying and laying synthetic Rubber insulated mats of sizes 2m x 1m and 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and as directed
All as per item No. 28 but rubber insulated mat of size 2.5 mm thick for voltage upto 11 kv (size 2x1m) complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6.3mm burried directly in ground vertically (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below normal ground level connected to GI strip of size 32x6mm (upto 7.5m long) by means of GI nuts, bolts and washers and 50 mm dia GI pipe light grade for protection of earth lead and 20mm dia GI pipe medium grade (upto 7.5m long) for watering arrangement and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule Part I including necessary excavation and earth work in any type of soil, charcoal, dust salt, PCC 1:2:4 type B1 in chamber, 40mm thick RCC 1:2:4 type B1 in cover slab with 8mm dia TMT bars at 100mm C/C both ways and with 8mm dia MS hook complete and testing all as specified and directed.
M&L in repairs for Cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 4/ 3.5 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm.complete all as specified and as directed
All as per item No. 30 but cable size 120 sq mm to 185 Sq mm core complete all as specified and as directed.
M&L for steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) including dismantling existing old u/s LT Poles of any size & making good the disturbed surface complete all as specified and as directed. Notes: Excavation, earthwork, foundation concrete and coping shall be measured and paid separately under relevant items of this Schedule.
M&L for plain Cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and as directed.
M&L for plain Cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate for foundation of poles complete all as specified and as directed.
S&F in repairs Sheet Moulding Compound (SMC) Junction box, 300x200x105 mm internal size, off white colour, with front hinged type door and locking arrangement with and including provision of 1 No. of 8 way bakelite connector terminal block suitable for 3 phase cable upto 16 sqmm size and provision of 1 No. of MCB SP 6-32 Amps, box fixed on pole/ wall with suitable clamps, bolts and nuts all as specified and as directed. Make: SINTEX or equivalent
S&F in repairs street light bracket made out of GI pipe light grade 40 mm dia not less than 1.20 metres in length and bent to shape fixed to walls/ poles with suitable MS clamps, bolt, nuts etc. complete all as specified and as directed.
S&F as in repairs Automatic power factor correction panel of capacity 100 KVA in 12 stages with micro processor based by Supply, assembly, erection, testing and commissioning of Outdoor type floor mounted free standing, dust and vermin proof panel/DB with IP-55 protection CPRI approved ISO 9001 certified frame fabricated out of 40mm x 40mm x 4mm angle iron, 3 mm thick CRCA sheet for entire outer panel with single door and locking arrangements & 1.6 mm for inner compartment with 40mmx4mm flat Iron, MS surfaces epoxy based powder coated, shade as approved over 2 coats of red oxide primer, surfaces pre-treated in seven tank process for de-greasing, de-rusting & Phosphated, Panel / DB having front and rear opening for installation of separate cable alleys, busbar chamber and switchgear compartments, Provision in cable alleys to be kept for bottom cable entry for incoming & outgoing cables. A clear space of 200mm to be kept from floor level for switchgear compartment. Air ventilation breathers to be provided for heat dissipation. Suitable sized knock-out holes for cable glands shall be provided. Each compartment shall be numbered/lettered as per the approved drg. Affixing MV danger plate as suitable intervals/locations, fully internally wired with suitable size of thimbles. Incoming / outgoing internal connection with PVC insulated PVC sheathed multistranded copper wire of suitable size all as directed & comprising the following :-
BUS BAR CHAMBER :- (a) 200 Amp 3 Strips & Neutral Strip 100 Amp, Aluminium conductor, with color coded heat shrinkable sleave and shall be mounted on non hygroscopic, non combustible, track resistant, high strength DMC material, interconnection of all incomings & outgoings.
INSTRUMENT CHAMBER :- (i) Digital Multifunction Meter- 01 Set. (ii) Red,Yellow,Green Phase indicating Lights LED type 220V AC- 1 Set. (Set of three). (iii) Protection MCB 6 A SP C Series- 1 Set. (Set of three). Make of Metering Accessories :-L&T/ AE/ Trinity/ Schneider.
Tracing out fault in 11KV underground cable any size with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. Note: (i). Joint kit shall be measured and paid separately. (ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable. (iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted. (iv) T&P required for the entire job shall be provided by the contractor at his own end and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately. (vi) Fault & location thereof shall be traced within 12 hours of intimation by the Engineer-in-Charge and shall be rectified within given time frame
ASHIRWAD ELECTRICALS
metro electrical services
Green Ray Enterprises
M/s. VIJAY ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .