Loading…
Loading…
Tender Value
₹3.8 Cr
EMD Value
₹7.6 L
Closing Date
9 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TRD
16 conditions · 3 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
Note: In case, date of tender inviting is on or after date of statutory deadline for audit of balance sheet of previous FY (i.e. 30th Sept or as further extended for this FY), audited balance sheet of 4th previous year shall not be considered unless concerned CA certifies that balance sheet is not audited yet as on date of invitation of this tender.
Contractor/Firm should have Valid Electrical contractor license.
5 conditions · 2 needing a document upload
The tenderer shall submit all relevant documents as detailed in para 14 & 18.10 of Tender Form (Second Sheet) of Part I of GCC work-2022.
The tenderer shall submit copy regarding status of firm i.e. sole proprietorship, partnership, Company, Society/Trust etc. and also submit a power of attorney and other relevant documents as detailed in Para no. 15 of Tender Form (Second Sheet) of Part I of GCC-2022.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should quote only the above/below percentage on estimated value, in the space provided at web portal for the purpose & nowhere else. Financial & Technical conditions quoted at any place other than prescribed space shall not be entertained while evaluating the offer.
Tenderer are required to go through the documents attached along with the tender and submit their bids accordingly.
TRD modification work in c/w Provision of New TMC sidings along with facilities -29 Nos. over Bikaner Division.
02-TRD-BKN-ETender-26-27~NWR
02-TRD-BKN-ETender-26-27
Open
Works - General
18 Months
Bikaner, Rajasthan
₹0
₹7.6 L
18 Aug 2026
18 Aug 2026
26 Aug 2026
197 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 3,80,51,116 | ||
| — | 600.00 | — | — | ||
| Concrete for foundation and plinth in all type of soil including hard / rocky soil (including excavation and supply of all material viz. sand, cement and ballast, padding etc.). | — | — | — | 47,09,100 | |
| — | 70.00 | — | — | ||
| Supply of rolled or fabricated and galvanized traction mast, TTC, Portals, AT masts, feeder mast, bridge masts, DA etc. | — | — | — | 97,49,495 | |
| — | 70.00 | — | — | ||
| Erection of rolled or fabricated and galvanized traction mast, TTC, Portals, AT masts, feeder mast, bridge masts, DA etc. | — | — | — | 7,58,765 | |
| — | 14.00 | — | — | ||
| Supply of fabricated & galvanized steel work (SPS) other than masts with necessary components. | — | — | — | 19,49,899 | |
| — | 14.00 | — | — | ||
| Erection of fabricated & galvanized steel work (SPS) other than masts with necessary components. | — | — | — | 1,51,753 | |
| — | 140.00 | — | — | ||
| Supply of single cantilever assembly for conventional OHE (without insulator). | — | — | — | 36,90,120 | |
| — | 140.00 | — | — | ||
| Supply of Stay and bracket tube Porcelain type insulators (CD 1050mm) for single bracket assembly. | — | — | — | 16,71,768 | |
| — | 140.00 | — | — | ||
| Erection of single cantilever assembly complete with insulator for conventional OHE. | — | — | — | 3,74,178 | |
| — | 18.00 | — | — | ||
| Adjustment of OHE turnout (2 turnouts to be considered as 1 no.) / x-overs. | — | — | — | 3,47,880.6 | |
| — | 90.00 | Each Span | — | ||
| Transfer of OHE from one support to another and adjustment of droppers / slewing of OHE. | — | — | — | 5,36,490 | |
| — | 90.00 | Each Span | — | ||
| Re-droppering of spans including making profiling and adjustment of height & adjustment of encumbrance including removal of kink. | — | — | — | 1,62,918 | |
| — | 24.00 | — | — | ||
| Supply of three Pulley type Regulating equipment (Conventional type) with complete assembly excluding insulator & termination arrangement. | — | — | — | 16,91,798.4 | |
| — | 24.00 | — | — | ||
| Erection of three Pulley type Regulating equipment (Conventional type) with complete assembly. | — | — | — | 2,48,457.6 | |
| — | 8.00 | — | — | ||
| Supply of Fixed Termination Anchor (FTA) standard arrangement complete (without insulator). | — | — | — | 75,784 | |
| — | 8.00 | — | — | ||
| Erection of Fixed Termination Anchor (FTA) standard arrangement (with insulator). | — | — | — | 19,756.8 | |
| — | 24.00 | — | — | ||
| Supply of materials for termination of single/ double conductor of OHE (without insulator). | — | — | — | 2,23,360.8 | |
| — | 24.00 | — | — | ||
| Erection of materials with insulator for termination of single/ double conductor of OHE. | — | — | — | 41,716.8 | |
| — | 35.00 | — | — | ||
| Supply of complete Guy rod assembly. | — | — | — | 3,98,758.5 | |
| — | 35.00 | — | — | ||
| Erection of complete Guy rod assembly. | — | — | — | 63,059.5 | |
| — | 6.00 | — | — | ||
| Supply of section insulator assembly including core insulator (without cut-in insulator). | — | — | — | 4,50,273.6 | |
| — | 6.00 | — | — | ||
| Erection of complete section insulator assembly including core and cut-in insulator. | — | — | — | 44,902.2 | |
| — | 6.00 | — | — | ||
| Supply of 25kV single pole isolator with 160sqmm jumpering arrangement (without insulators and earth contact assembly). | — | — | — | 4,12,306.2 | |
| — | 6.00 | — | — | ||
| Supply of insulators (2 post insulator and 1 operating rod insulator) for isolators. | — | — | — | 1,47,467.4 | |
| — | 6.00 | — | — | ||
| Erection of 25 kV single pole isolator with insulator and jumpering arrangement (without earth contact assembly). | — | — | — | 43,661.4 | |
| — | 6.00 | — | — | ||
| Supply of Earth Contact assembly on isolator. | — | — | — | 50,560.2 | |
| — | 6.00 | — | — | ||
| Erection of Earth Contact assembly on isolator. | — | — | — | 8,565.6 | |
| — | 48.00 | — | — | ||
| Supply of 25kV post insulator and all components such as pedestal cap, clamps, stud bolts etc. to support jumper/busbar. | — | — | — | 5,08,459.2 | |
| — | 48.00 | — | — | ||
| Erection of 25kV post insulator and all components such as pedestal cap, clamps, stud bolts etc. to support jumper/busbar. | — | — | — | 18,360 | |
| — | 96.00 | — | — | ||
| Supply of 18mm copper solid bus bar. | — | — | — | 2,79,705.6 | |
| — | 96.00 | — | — | ||
| Erection of 18mm copper solid bus bar with fittings. | — | — | — | 55,939.2 | |
| — | 60.00 | — | — | ||
| Supply of 9 Tonne porcelain cut in insulator. | — | — | — | 3,02,298 | |
| — | 12.00 | — | — | ||
| Erection after testing of 9 Tonne porcelain cut in insulator. | — | — | — | 14,767.2 | |
| — | 300.00 | — | — | ||
| Supply of 130 sqmm stranded cadmium copper large span wire as per RDSO spec. no. TI/SPC/OHE/CAT(Cu-Cd)/0971 or latest with required fittings. | — | — | — | 3,55,920 | |
| — | 300.00 | — | — | ||
| Erection of Large span wire (130 sqmm stranded cadmium cu wire) with fittings. | — | — | — | 35,850 | |
| — | 2.00 | — | — | ||
| Supply of Anti creep arrangement (without insulator). | — | — | — | 76,702.6 | |
| — | 2.00 | — | — | ||
| Erection of Anti creep arrangement with insulator. | — | — | — | 8,253 | |
| — | 25.00 | — | — | ||
| Supply of copper jumpers ATJ/C/F type. | — | — | — | 36,365 | |
| — | 25.00 | — | — | ||
| Erection of copper jumpers ATJ/C/F type. | — | — | — | 7,892.5 | |
| — | 20.00 | — | — | ||
| Supply of G Jumpers (160 sqmm) with fittings. | — | — | — | 2,21,954 | |
| — | 20.00 | — | — | ||
| Erection of G Jumpers with fittings. | — | — | — | 47,292 | |
| — | 2.00 | — | — | ||
| Splicing and extension of anchor OHE. | — | — | — | 17,327 | |
| — | 2.50 | — | — | ||
| Supply of overhead equipment excluding catenary and contact wire. | — | — | — | 61,775 | |
| — | 2.50 | — | — | ||
| Erection of overhead equipment including catenary and contact wire. | — | — | — | 61,135 | |
| — | 30.00 | — | — | ||
| Supply of material for single earth electrode with earth pit complete as per RDSO Drg. No. ETI/OHE/P/7020 or latest. Price also cover supply of 40 x 6 mm MS flat as well as all nut bolts necessary for earthing connection. | — | — | — | 1,27,011 | |
| — | 30.00 | — | — | ||
| Erection of single earth electrode with pit as per RDSO Drg. No. ETI/OHE/P/7020 or latest. The price include digging / excavation of earth, treatment of earth electrode by charcoal & salt, bonding with supply, fabrication (shaping) and providing 40 x 6 mm MS flat for earthing connection with making holes and bolting (Galvanized fasteners / bolts) for earth connections between earthing station & structure / equipment and from earth pit to rail. The connecting MS flats are to be painted with two coat of red oxide and two coat of black bituminous paint. The price also includes erection of earth pit duly white wash & painting of earth value on the same. | — | — | — | 52,917 | |
| — | 125.00 | — | — | ||
| Supply of structure bonds. | — | — | — | 1,08,800 | |
| — | 125.00 | — | — | ||
| Erection of structure bonds. | — | — | — | 18,337.5 | |
| — | 40.00 | — | — | ||
| Supply of transverse (cross rail, inter track) & special bonds. | — | — | — | 48,952 | |
| — | 40.00 | — | — | ||
| Erection of transverse (cross rail, inter track) & special bonds. | — | — | — | 4,436 | |
| — | 40.00 | — | — | ||
| Supply of longitudinal bonds. | — | — | — | 31,316 | |
| — | 40.00 | — | — | ||
| Erection of longitudinal bonds. | — | — | — | 4,724 | |
| — | 2200.00 | — | — | ||
| Developing the sectioning / schematic / TSWR diagram with computerized digital printing on adhesive vinyl of adequate size and color as per requirement. | — | — | — | 9,78,560 | |
| — | 60.00 | — | — | ||
| Supply & erection of various types of enamel caution boards (approx. area in range of 500-1000 sq.cm. per board). | — | — | — | 18,174 | |
| — | 30.00 | — | — | ||
| Supply of enamel/retro reflective structure plate/boards for traction use (approx. area in range of 1000-1200 sq.cm. per board). | — | — | — | 32,355 | |
| — | 30.00 | — | — | ||
| Erection of enamel/retro reflective structure plate/boards for traction use (approx. area in range of 1000-1200 sq.cm.). | — | — | — | 3,384 | |
| — | 30.00 | — | — | ||
| Supply of enamel/retro reflective danger/caution, unwired turnout, engine stop, sigma boards and other similar type of boards (approx. area in range of 1200-6000 sq.cm. per board). | — | — | — | 67,206 | |
| — | 30.00 | — | — | ||
| Erection of enamel/retro reflective danger/caution, unwired turnout, engine stop, sigma boards and other similar type of boards (approx. area in range of 1200-6000 sq.cm.). | — | — | — | 16,626 | |
| — | 80.00 | — | — | ||
| Supply of material for 5/7 mm dropper wire for re-droppering of spans. | — | — | — | 85,056 | |
| — | 90.00 | — | — | ||
| Breaking of concrete foundation of mast, portal, TTC etc. | — | — | — | 1,59,849 | |
| — | 20.00 | — | — | ||
| Dismantling of Regulating equipment. | — | — | — | 1,98,606 | |
| — | 22.00 | — | — | ||
| Dismantling and removal of Guy rod assembly. | — | — | — | 33,631.4 | |
| — | 80.00 | — | — | ||
| Dismantling of cantilever assembly. | — | — | — | 1,40,720 | |
| — | 1.00 | — | — | ||
| Dismantling of Section Insulator. | — | — | — | 4,335.8 | |
| — | 3.00 | — | — | ||
| Dismantling of Isolator. | — | — | — | 4,467 | |
| — | 1.20 | — | — | ||
| Dismantling of OHE wires, contact, catenary, droppers etc. | — | — | — | 67,135.68 | |
| — | 4.00 | — | — | ||
| Dismantling of Anti-creep. | — | — | — | 10,619.6 | |
| — | 12.00 | — | — | ||
| Dismantling & removal of mast, portal, TTC & other small part steel. | — | — | — | 1,22,353.2 | |
| — | 60.00 | — | — | ||
| Dismantling of mast/upright by cutting. | — | — | — | 1,33,680 | |
| — | 12.00 | — | — | ||
| Preparation of Design & Drawings as per RDSO principle of OHE design & specification, Sectioning Diagram and Lay out plan. | — | — | — | 1,76,814 | |
| — | 110.00 | — | — | ||
| Preparation of as erected LOP. | — | — | — | 5,79,117 | |
| — | 140.00 | — | — | ||
| Checking and preparation of SED. | — | — | — | 1,03,194 | |
| — | 3.00 | — | — | ||
| Adjustment of insulated / un-insulated overlap. | — | — | — | 3,868.8 | |
| — | 2200.00 | — | — | ||
| Fabrication and supply of pre compressed particle laminated boards white in color with aluminum beading 1/2" x 1/2" on all around the board and an arrangement of fixing / hanging on wall of adequate strength on top of boards required in size. | — | — | — | 1,75,560 | |
| — | 20000.00 | — | — | ||
| Transportation charges for OHE material. | — | — | — | 2,90,000 | |
| — | 2.00 | — | — | ||
| Dismantling of Auxiliary Transformer with complete accessories and mounting arrangement and handing over to concerned TRD staff. | — | — | — | 18,789 | |
| — | 2.00 | — | — | ||
| Erection, oil filtration, testing & commissioning of AT. | — | — | — | 12,794.4 | |
| — | 2.00 | — | — | ||
| Supply of 25 kV drop out fuse switch assembly complete with fuse carrier & fuse element. | — | — | — | 70,423.4 | |
| — | 2.00 | — | — | ||
| Erection of 25 kV drop out fuse switch assembly complete. | — | — | — | 5,394.8 | |
| — | 2.00 | — | — | ||
| Supply of 9-ton suspension insulator assembly including all accessories. | — | — | — | 17,084.2 | |
| — | 2.00 | — | — | ||
| Erection of 9-ton suspension insulator assembly including all accessories. | — | — | — | 4,660.6 | |
| — | 2.00 | — | — | ||
| Supply of copper jumper wire from AT to OHE with components. | — | — | — | 18,674.6 | |
| — | 2.00 | — | — | ||
| Erection of copper jumper wire from AT to OHE with components. | — | — | — | 1,557.2 | |
| — | 16.00 | — | — | ||
| Supply of 50 x 6 mm MS flat earth bus. | — | — | — | 4,348.8 | |
| — | 16.00 | — | — | ||
| Erection of 50 x 6 mm MS flat earth bus. | — | — | — | 1,296 | |
| — | 10.00 | — | — | ||
| Supply of copper strips of size 25 mm x 3 mm for earthing of AT with mast. | — | — | — | 8,565 | |
| — | 10.00 | — | — | ||
| Erection of copper strip for earthing of AT with mast. | — | — | — | 1,345 | |
| — | 2.00 | — | — | ||
| Supply of anti-climbing device for AT station. | — | — | — | 4,646 | |
| — | 2.00 | — | — | ||
| Erection of anti-climbing device for AT station. | — | — | — | 1,378.2 | |
| — | 2.00 | — | — | ||
| Supply and erection of LT Junction Box for AT. | — | — | — | 43,824.4 | |
| — | 0.40 | — | — | ||
| Dismantling of Feeder/Return Conductor. | — | — | — | 2,367 | |
| — | 0.20 | — | — | ||
| Supply of copper cross feeder wires (37/2.25 mm HDBC) across the track at SP/SSP/FP/BT locations. | — | — | — | 2,78,141.22 | |
| — | 0.20 | — | — | ||
| Erection of copper cross feeder wires (37/2.25 mm HDBC) across the track at SP/SSP/FP/BT locations. | — | — | — | 748.76 | |
| — | 5.00 | — | — | ||
| Erection (with insulator) of materials for termination of copper cross feeder with gantries. | — | — | — | 4,476 | |
| — | 0.20 | — | — | ||
| Manual Erection of all aluminium 25KV Feeder/ Return conductor (Single Spider). | — | — | — | 1,170.4 | |
| — | 1.00 | — | — | ||
| Erection (with insulator) of material for termination of all aluminium 25KVFeeder / return conductor (Single Spider). | — | — | — | 895.2 | |
| — | 3.00 | — | — | ||
| Erection (with insulator) of a suspension (9Tonne) Insulator. | — | — | — | 1,105.8 | |
| — | 84.00 | — | — | ||
| Construction of TSWR as per approved sectioning diagram and ACTM. | — | — | — | 9,20,740.8 | |
| — | Breakup | for details. | — | ||
| 100% extra on erection rates for work done under power block for items mentioned below: | — | — | — | 26,92,092.34 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tender Document
ATTACHMENT
TenderDocumentEtenderTRD0226-27.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].