Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹50.0 LAccepted-AOC 30 20 ATHIPALAYAM ROAD CHINNAVEDAM PATTI POST COIMBATORE 641 006 TN | COIMBATORE | COIMBATORE | TAMIL NADU | 641006 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹54.3 L+₹4.3 L (8.55%)Rejected-Finance 121004 | L2 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 3 | L3₹55.3 L+₹5.3 L (10.5%)Rejected-Finance 47A C3 OLD DAMU NAGAR PULIAKULAM COIMBATORE 641 045 | COIMBATORE | COIMBATORE | TAMIL NADU | 641045 | L3 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 4 | L4₹55.7 L+₹5.7 L (11.4%)Rejected-Finance | L4 | Rejected-Finance BEING NOT LOWEST TENDER | |
| 5 | L5₹58.1 L+₹8.1 L (16.2%)Rejected-Finance 2 375 ARAVENU POST KOTAGIRI THE NILGIRIS TAMIL NADU 643 201 | KOTAGIRI | THE NILGIRIS | TAMIL NADU | 643201 | L5 | Rejected-Finance BEING NOT LOWEST TENDER |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
13 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SULUR
Garrison Engineer AF Sulur Military Engineer Services Kangayampalayam Post Sulur Coimbatore 641 401
REPAIR MAINT TO FIRING RANGE AREA BRICK WORK HARDSTANDING ROOFING AND CERTAIN MISC B R WORKS AT AF STN SULUR
2020_MES_389581_1
8371/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE AF SULUR
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
GE AF SULUR
₹98,000
Yes
18 Dec 2020
24 Oct 2020
14 Nov 2020
24 Oct 2020
13 Nov 2020
7 Nov 2020
24 Oct 2020 - 6 Nov 2020
60 days
Amount
SCHEDULE A BOQ
Demolition of brick work masonry, built in cement mortar including all quoins, pillars etc., complete all as specified and directed.
Fly ash Brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
Fly ash Brick work obtained from demolition of brick work on plan exceeding 6 M mean radius built in cement mortar 1:4 complete all as specified and directed.
Demolition of cement concrete reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position etc complete all as specified and as directed.
Reinforced Cement Concrete Type B1 1:2:4 (using 20 mm graded granite stone aggregate) cast in situ in lintels up to 1.5 M span, cills and other similar bands, plinth courses, parapets, copings, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating as directed including use and waste of form work complete all as specified and directed.
Deformed TMTsteel bar of grade Fe-500, 5mm dia and over upto 10 mm dia in stirrups, spacers and binders etc conforming to IS 432 cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
Rendering 15 mm thick in two layers on brick or concrete surfaces,first coat 10mm thick in cement mortar 1:4 and 2nd coat 5mm thick in cement mortar 1:4 mixed with water proofing compound as per manufacturer instructions finished even and smooth without using extra cement complete all as specified and directed. Note: (a) Water proofing compound shall be measured and paid seperately. (b) The unit rate quoted is deemed to included for Removing of accumulated earth of any width and depth upto 15 cm cleaning/cutting the grass with hand operated petrol/kerosene driven grass cutting machine and removing the grass waste around 3 m from plinth protection to outside MD land Note: Periodicity of cutting of grass shall be before commencement of work and after completion of repairs.
Supply Only integral water proofing compound complete all as specified and as directed. Make:-Dr. Fixit Pidi Proof and equivalent.
Complete removal of existing water proofing treatment and expose of top surface of RCC slabof any thickness, any type by stripping out old tar felt over roofs, parapets, chimney stacks etc laid horizontally or vertically including taking out layer of cement plaster etc and cleaning the surface with water and using wire brush including removing debris to out side the MoD land and providing following :- (a) Dismantling existing cement concrete/roof tiles on roof including removing debris to out side MD land as directed. (b) Bring upto the slope by providing filling of light weight materials sch as cinder, light weight concrete etc as required, and then providing PCC 1:2:4 type B1 of average thickness of 50mm. (c) Rendering 10mm thick in CM 1:3 on concrete roof surfaces and finish the surface even and smooth without using extra cement including mixing water proofing compound @ 3% by weight of cement. (d) Apply a coat of bituminous primer confirming to IS-3384@ 0.4 ltr/Sqm on newly plastered surface after curing as per IS-456 and dried. (e) After the primed surface has dried, apply a coat of hot blown bitumen(85/25 penetration) confirming to IS-702 @ 1.2 Kg/Sqm of the surface. (f) Providing APP modified water proofing as approved by GE weighing not less than 4kg per sqm unrolled over the bituminous coated surgace with 100mm over laps, the overlap shall be sealed by flame as per manufacture instructions complete. (g) Over the APP membrane, apply evenly a tack coat of hot air blown bitumen of grade 85/25 at the rate of 1.20 kg per sqm including cleaning of surface. (h) Applying a coat of aluminium paint at the rate of 100 gm per sqm as per manufacture instruuction over bituminous layer complete all as directed. Note : (i) Care shall be taken to avoid wrinkle and air gaps while sticking membrane to the bitumen applied surface.
Plain cement concrete type B-1, 1:2:4 (20mm graded aggregate) as in roof kerbs,benching rounded or chamfered on edge all as specified complete all as directed.
Repair of leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damage portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed by Engineer-in-Charge
Repair of leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damage soil waste pipes or fittings of any shape, specification and size, making good to the damage portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and matching to existing wall complete to avoid the leakage/ seepage at the site of work as directed and specifie by the Engineer -in- charge
Note for item No 12 & 13 (a) Find out main cause of leakage and take necessary steps to resolve / rectify. (b) Replace existing tiles in case lakage through NT/FT. (c) The rate also include provision of new NT/FT. (d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as direct by the manufacturere specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit
Removing the existing sand from the firing butt and refilling in the same area after seiving the sand with out any fired bullet scrap, pebbles etc, complete all as specified and directed.
River sand (M sand prohibited) filling in firing butt of height average 3.2m including necesaary watering complete all as specified and directed.
Supply only saw dust and mixing with sand in proportion as directed including filling in the firing butt complete all as specified and directed.
Polyethene bag of 50 Kg capacity and river sand filling (M sand prohibited) in bag after screening, striching the bag with hand machine and stacked/placed upto 1.5m heightcomplete all as specified and directed.
Glazed ceramic coloured tiles 450 x 300 mm x 7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles on vertical surface such as dado, laid over and including backing coat with cement mortar 10 mm thick in CM 1:3 complete complete all as specified and directed. Note : The Unit rate is demend to be included for : (a) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Joint free non skid coloured ceramic tiles 7 mm to 8mm thick (Square/rectangular) area of each tile exceeding 0.09 Sqm but n exc 0.18 Sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with tiles , laid over and including cement screed bed 15 mm thick in CM 1:4 complete Note : The Unit rate is demend to be included for : (a) Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation/fixing
Taking down Chowkats or frames with shutters (Without taking off shutters from the frames) not exceeding 1.5 Sq. M each complete all as specified and directed.
Taking down Chowkats or frames with shutters (Without taking off shutters from the frames) exceeding 1.5 Sq. M each but n exc 4 sq.m each complete all as specified and directed.
Taking down shutters from the frames exceeding 1.0 Sq. M each but n exc 2 sq.m each complete all as specified and directed.
Minor repair to aluminum/ glass doors, windows, partitions and making good the same (i.e. Handels, hings, rubber beadings, clips etc) complete all as specified and directed.
Second class hard wood plain, solid, straight Chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered, put together with glue pinned at joints complete all as specified and directed.
Solid PVC door frame of size 50mmX47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling & fixing in opening as per specificatioon and drawing
Factory made Solid PVC Door Shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded / sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement complete all as specified.
30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a), all as specified and directed.
Second class hard wood plain fillets, square, rectangular or triangular in section, clean sawn, se-cured with nails or brads in section area 6 sq.cm but not exc 13 sq cm including taking down exisiting one
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete all as specified and directed.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.4mm complete including taken down existing one complete all as specified and as directed by Engineer-in-Charge.
75mm long medium weight, stainless steel, butt hinges all as specified and directed.
75mm long medium weight, stainless steel, butt hinges fixed as in repair and welded to metal frame n exc. 2.5 cm in length and n exc 6 mm of metal thickness.
5mm thick rubber beading strips of entrance doors having width exc 3CM to not exc 5CM to arrest entry insects including taking down existing one complete all as specified and as directed
Galvanished mild steel wire cloth, 0.63mm nominal dia of wire & average width of aperture 1.40mm & fixed with tinned tacks, or galvanished wire staples
Providing & fixing 10mm thick plaster of paris ceiling (Gypsum anhydrous) to flat surface over second class hard wood fillets & reinforced with G.I. wire mesh (Fillets & G.I. wire mesh measured and paid seperately)
Providing & fixing plaster of paris (Gypsum anyhdrous) decorative border of any thickness and width including dismantling all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material and labour for 4mm plain sheet glass ordinary quality and glazed with oil putty or fixed with fillets 2nd class hard wood of sectional area not exc 3 Sqcm and glass not exc 0.5 sqm each pane complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames/steel frames glazed with putty or fixed with beads and material Supply and fixing 4mm thick figured glass pin head type and glazing with oil putty or wooden beads in squares exc. 0.50 Sqmtr each pane complete all as specified and as directed
Pre painted Coloured Galvalume roofing system sheet 0.50 mm thick having Zinc aluminum alloy coating AZ150 shall be as per IS:277/ASTM 1379 150 gsm/ sqm double ribbed trapezoidal profile steel sheet any colour having tensile strength of 550 Mpa as in Roof covering /cladding to wall fixed with self tapping screws including dismantling of existing roof sheet complete all as directed.
Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws including dismantling of existing roof sheetas specified
Note for Pre-painted coloured Galvalume roofing :-
(i) The manufacturer's test certificate and individual test certificate for the chemical and mechanical properties of sheet must be submitted for approval by the concerned authority prior to installation.
(ii) The contractor shall ensured that no leakages take place from the roof. The roofing shall be Coloured Galvalume roofing system (olive green colour or as approved by GE) with feed material manufactured from 0.50 mm Total coated thickness (TCT), minimum 550 MPa yield strength and shall conform to the physical specifications of IS: 2062 of 2011, coated with hot dip metallic Aluminium / Zinc alloy coating AZ150 as 150 gm/sq.mt total on both sides.
(iii) The painting shall be coloured baked enamel polyester with silicon coating of film thickness 25 microns nominal on the exposed face/exterior side and on the reverse side ( interior face) shall be white with 15 microns film thickness, over a coat of 5 micron nominal thickness Primer.
(iv) The contractor shall produce purchase vouchers for each lot for verification of Engineer-in-Charge.
Magnetic catches with 8mm dia steel ball and brass body and striking plate including letting in complete all as specified and directed.
40 mm dia cupboard knobs fixed with nut, screw and washer of brass polished including taking down complete all as specified and as directed.
25 mm dia mild steel powder coated drapery rod cut to length required without joint in between and fixed at openings as directed
Mild steel powder coated fancy type end brackets fixed at both ends of drapery rod same colour and type of drapery rod as directed.
Mild steel powder coated fancy type holding brackets flat 20mm wide for holding the drapary rod and fixed to wall with MS srew as specified and as directed
Resecuring without taking down chowkhats or frames (without taking off shutters from the frames) not exc 1.5 sqm each
Resecuring without taking down chowkhats or frames (without taking off shutters from the frames) exc 1.5 Sqm but n exc 4 Sqm each.
Taking down shutters exc 1 sqm but n. exc 2.0 sqm and refixing in the same location complete all as specified and as directed.
Taking down the existing locking system, contains any number of levers replacing the strucked/damaged levers, applying oil to all parts and making functional properly and re-fixed in position complete all as specified and as directed
Mortice lock brass 4 levers vertical type of size 100mm fixed as in repair
150 mm long Brass barrel towel bolts, with cast or sheet barrel and rolled or cast bolts and fixed including taking down existing one complete all as specified and directed
125 mm long Brass barrel towel bolts, with cast or sheet barrel and rolled or cast bolts and fixed including taking down existing one complete all as specified and directed
150 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
100 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed.
150 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
100 mm long Extruded Aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
250 mm mild steel ordinary rat rail rod pattern spring including roller and roller plate including taking down existing one all as specified and directed.
Resecuring of easing & adjusting without taking down shutters of n exc 1 sqm each
Resecuring or easing & adjusting without taking down shutters of exc 1 Sqm but n exc 2 Sqm each
Applying two coat of synthetic enamel paint over a coat of pink primer of any description over 10 cm width or girth including preparation of new wooden surfaces complete all as specified and directed.
Applying two coat of synthetic enamel paint over a coat of pink primer of any description over 10 cm width or girth including preparation of new steel surfaces complete all as specified and directed.
Note :- (a) All synthetic enamel paint, plastic emulsion paint shall be of 1st quality manufactured by the standard firms of make as specified.
(b) The contractor shall inform the GE, within three weeks of the acceptance of the tender, the brand/names of the manufacturers of paint proposed to be used in the works and submit samples thereof and obtain prior written approval of GE before their use in works.
(c) The contractor shall when so required by the GE, produce certificate from the manufacturer or their representative to establish that the brands of paints purchased by the contractor from them, satisfy the requirements of the relevant Indian Standards. Tint of paint, will be approved by the GE.
(d) Paints shall be obtained direct from approved manufacturer or from their authorized agents only of respective brands mentioned below and brought to site in sealed containers. The paint so procured shall be of first quality of any approved make as per list of makes specified. i. Berger Paints (Luxol), ii. Jenson & Nicholson (Brolac), iii. Shalimar Paints(Superlac), iv. Goodlass Nerolac (Nerolac), v. Asian Paints(Apcolite)
(e ) Unless otherwise specified the tints of paint shall be as approved by the GE
(f) The contractor shall submit samples of the paints proposed for the work along with results of tests conducted in approved laboratory as directed by the Engineer-in-Charge for approval.
(g) The surface shall be thoroughly cleaned and dusted. All dirt scales oil and grease shall be thoroughly removed before painting is started. The prepared surface shall be inspected and approved by the GE before painting is commenced. The weather shall not be foggy/rainy, dusty or windy. The suitability of the weather will be determined by the Engineer-in-Charge.
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,15 mm thick in Cement Mortar 1:6 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Vitrified Ceramic tiles 10 mm thick, dark shade (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in skirting/dado. etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer ,10 mm thick in Cement Mortar 1:3 including taking down existing tile and removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. Note : (a) Vitrified tiles are classified under group B1a of the international Standard for ceramic tiles ISO: 13006. Tiles shall be hard, dense, impervious and frost resistant. Water absorption of tiles shall be less than 0.5% and flexural strength (Modulus of Rupture) shall be more than 35 N/Sqmm. (b) The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
False ceiling at any height with "Armstrong Ultima micro look tiles" manufactured by M/S Armstrong world industries using hot dipped galvanised steel section exposed surface chemically cleaned capping prefinished inbaked polyster paint, main tee of size 3000x32x15mm at 1200c/c and cross tee of size 1200x32x600 at 600mm c/c and wall angle of size3000x19x19mm around the wall to form grid of size 600*600 mm centre to centre.Hanger ofGI wire of 4.0mm dia to be fixed by approved roof plug' level adjusters and screws etc, The last hanger at the end of each main runner should not be greater than 450mm from the adjacent wall. Perimeter wall angle and micro look grid runner has to be on the 600x600mm mould including taking down of existing ceiling board of description complete all as directed. Make Armstrong or equivalent make as per list of makes
12mm thick toughened glasss frameless partition, with option of swing and sliding doors with all necessary to patch fittings and bottom insert like corner connection and side connector and bottom insert to the floor about 15 to 30mm or done with aluminium profile 12mm depth including taking down existing glass complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
100mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), laid in 1:20 slope as in hardstanding/ path including making joints @ 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement including demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thickness and rubish material shall be disposal to out side MD land complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Framed work such as grills, gratings, angles etc. with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, framework of static water tanks and similar work con- forming to Fe.290. Gde-E-165 including dismantling wrought iron or mild steel work of any description not otherwise provided for fencing/ watch tower having height 30m complete all as specified
Aluminium powder coated of three track sliding window outer frame top & sides (section no-20831) of size 92.0x31.75x1.5mm weighing 1.06 Kg/m, frame bottom (Section No 20832) of size 92.0x31.75x1.5mm weighing 1.248Kg/m , shutter to plain vertical (Section No 21093) of size 39x18x1.5mm weighing 0.634 Kg/m, shutter interlock vertical frame (section 21094) of size 39x18x1.55 weighing 0.734 Kg/m, shutter bottom horizontal frame (Section No 20551) size 40x20x1.5mm weighing 0.484 Kg/m, with powder coating of min thickness 50 micron , sliding type with out sash bars, 4mm thickness colour glass, rubber packing, snap beading screws with stainless steel wire mesh, including taken existing window with chowkats of any size, completet all as specified
250 mm long aluminium alloy ,anodisd ,sliding door bolt with hasp,stable (bolt type) and fixing of clips sheet ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed .
Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor 150mm complete all as specified and as directed by Engneer-in-Charge
Floor door stopper of aluminium alloy body and tongue anodized with hard drawn steel spring fixed in floor 150mm Including taken down existing one complete all as specified and as directed by Engneer-in-Charge
Door closer hydraulically regulated designation No. 3, universal type, Aluminium body (extruded section), suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed including taking down existing one all as specified and directed.
Material and Labour for Granite work (of any type) 18 to 20mm thick (table rubbed and polished including round edge) in steps, jambs, pillars, windowcills, cooking platforms, wash basin platform and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with granite shade over and including 15mm thick screed bed in cm 1:4 including dimantling existing one complete all as specified and directed by Engineer-in-Charge. NOTE : The manufacturer's test certificate and individual test certificate for tiles must be submitted for approval by the concerned authority prior to installation.
Hard core of broken/crushed stone aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L heavy duty techstone/geo stone vitrified tiles of size 600mmX600mm,10 mm thick square/rectangular) polished,area of each tile not exeeding 0.36 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over and including screed bed or bedding layer 10 mm thick in Cement Mortar 1:3 and backing coat of 10mm thick in CM 1:3 including taking down existing tile and rubbish off the MD premises complete all as specified and as directed.
12mm thick toughened glass for doors including polished by machine on edges including stainless steel clips/hinges, stainless handles (02 Nos), floor spring double action including taking down existing glass complete all as specified and as directed by Engr-in-Charge (Make : Saint Gobin/ESG/Modi)
False ceiling using GI snap grid size 60x60cm with main runner 38x24,wall angle & cross tee 29x24mm wall angle 24x24mm suspended with 4mm dia GI Wire fixed with steel dash fasteners carrying max load upto 8.1 Kg/Sqcm with 4mm thick designer ceiling board (Lake & Hill) all as per Everest regular T-2430 or equivalent (Make-Ramco/Charminar/Armstrong) including dismantling.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm in any type of soil all as directed.
Cement concrete (1:3:6) type C-1 (20 mm graded aggregate) as in foundation filling and mass concrete all as directed.
Steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt,welded tubes conforming to IS 1161-1979 grade ST-240 including dismantling of existing steel complete all as specified
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc 10cm and dia of neck 11 to 15 mm including taking down existing one complete.
Mild steel sections in hold fasts, clamps, wind ties and similar small articles confirming to Fe 410-0 or Fe 310.0 complete all as specified and directed.
S& F Plates (plain or chequred ) channel ,square or notched (ordinary and countersunk )forming holes with rieveted ,bolted or welded or welded attachment(Fe 410 -W (E-250) quality A including dismantling of existing one complete all as specified
Preparation of new or previously untreated steel surfaces under 10 cm girth and applying two coat of synthetic enamal paint including onecoat of red oxide primer
Deformed TMT steel bar of grade Fe-500, 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
9mm thick prelaminated particle board, interior grade, prelaminated both sides with decorative choice lamination fixed with screws to aluminium frame including taking down existing one complete all as specified and as directed.
Powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat etc. including taking down existing one complete all as specified and directed. Note: Minimum thickness of powder coating 50 micron.
Coloured tinted float glass and glazing, 5.5 mm thick with oil putty in squares not exceeding 0.5 Sq.m in each pane, with glazing clips and oil putty, including taking down existing one complete all as specified and directed.
Powder coated aluminium door shutters,aluminium section weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each doors, hinges anodised aluminium snap beading screws etc including taking down existing one complete all as specified and directed. Note:-Glazing and particle board work shall be measured and paid seperately.
Cutting holes in stone wall exc half brick and n.exc one brick in cement mortar for inserting hold fasts and making good desmantled portion in cement mortar 1:3 or 1:2:4 type B-1 concrete as required.
S & F in repair double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box main body with stainless steel cover governing pivot made of brass, other parts made mild of steel heavy duty and fixed including taking down existing one all as specified.
Mortice lock brass 4 levers vertical type size 100mm fixed as in repair include for escutcheon plate two keys all as directed.
S & F framed bracket of angles or tees with web and flanges cut to shape ,drilled and countersunk for screw ,including bending and welding angles, as necessary ,gusset plates, riveting etc ..n.exc 10 kg each brackets ,confirming to Fe-290 Gde E-165 (brackets over 10 kg each to be measured under structural steel) ncluding dimantling of existing one all as directed.
Rotational moulded polythene water storage tank of 1000 Ltrs capacity (three layer white colour) cylinderical vertical with closed top including 3 Nos GI check nuts and tank nipple of 25mm bore for inlet and outlet, 25mm bore ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball hoisted and fixed in position all as specified in SSR part -I including taking down of old unserviceable tank complete all as specified and directed.
Preparation of new decorated plastered or unplastered surface of wall, brooming down or steel wire brushing down smoke soot, moulds mass, efflorescent , trading, oil, greasy spots and applying two coats of cement base paint over a coat of primer on external surfaces of walls and curing to CBP to required period complete all as specified and as directed.
75mm thick, plain cement concrete (1:3:6), type C-2 (using 40 mm graded mechanically crushed stone aggregates), laid in 1:20 slope as in plinth protection/path including making joints 1t 3.00 metre intervals and at each corner, the joint shall be filled with mastic filling (to full depth) comprising of one part heated hot blown bitumen 85/25 & two parts heated sand (by volume), surface finished even and smooth without using extra cement complete all as specified and as directed. Note :- The concrete shall be laid at a stretch not exceeding 3 metre in length and width of joint shall not be more than 12 mm.
Easing of door shutters for easy closing/opening and tightening of hinges or changing the position of hinges, adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed by Engineer-in-Charge, Size of door upto 2 Sqm single leaf or double leaf.
Easing of window shutters, kitchen cupboard shutters, show case shutter drawers including fixing of screws adjusting handles, knobs tightening piano hinges including misc small adjustments complete all as specified and directed by Engineer-in-Charge, size of window upto 1.5 Sqm.
Flush shutters,30mm thick, solid core construction, with particle board core and ply wood face panels, commercial type on both sides, complete all as specified and directed.
Fixed in repair 300 mm long aluminium alloy ,anodisd ,sliding door bolt with hasp,stable (bolt type) and fixing of clips sheet ,cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy complete all as specified and directed
100mm long medium weight fixed as in repair and welded to metal frame n exc. 2.5 cm in length and n exc 6 mm of metal thickness.
Repair to doors by supply and fixing bottom rail of second class hard wood 35 mm thick including making of grooves and fixing new bottom rail by replacing defecting rail using fevicol and wooden pinning. Size of bottom rail shall be 200 mm wide and shall be treated with two coats of painting over primer complete all as specified and directed by Engr-in-charge.
Supply and fixing in repair aluminium anodized hasp and staples safety type with mild steel hinge pin incl bolt to hinge plate fixed with screws of 100mm length.
Repair to doors by supply and fixing middle rail of second class hard wood 35 mm thick including making of grooves and fixing new middle rail by replacing defecting rail using fevicol and wooden pinning. Size of lock/middle rail shall be 150 mm wide and shall be treated with two coats of painting over primer complete all as specified and directed by Engr-in-charge.
100mm long medium weight, stainless steel, butt hinges all as specified and directed.
Supply and Fixing continuous (piano) hinges, stainless steel bright finish or electrogalvanised of 40mm width of flaps (when open).
Repair to doors by supply and fixing Top rail of second class hard wood 35 mm thick including making of grooves and fixing new top rail by replacing defecting rail using fevicol and wooden pinning. Size of stiles/ top and freeze rails of size 100 mm wide and shall be treated with two coats of painting over primer complete all as specified and directed by Engr-in-charge.
Neptune Engineers and Builders
KRISHNA ENTERPRISES
NAVEEN ENTERPRISES
G Perumal and co
D.R ASSOCIATES
M/s Shana Constructions
p.chinnasamy
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .