Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.8 LAccepted-AOC 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NORTH | DELHI | 110006 | L1 | Accepted-AOC Accepted due to lowest rate quoted | |
| 2 | L2₹26.3 L+₹3.4 L (15.1%)Rejected-Finance RZ 1 7 167 GALI NO 6 DURGA PARK NASIRPUR SOUTH WEST DELHI DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance Rejected due to highest rate quoted. | |
| 3 | L3₹33.1 L+₹10.2 L (44.7%)Rejected-Finance | L3 | Rejected-Finance Rejected due to highest rate quoted. | |
| 4 | L4₹34.0 L+₹11.1 L (48.8%)Rejected-Finance RZ 50D GALI NO 13 VASHISHT PARK PANKHA ROAD NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Rejected due to highest rate quoted. | |
| 5 | L5₹34.8 L+₹11.9 L (52.1%)Rejected-Finance 19 62 1ST FLOOR WEST MOTI BAGH SARAI ROHILLA NEW DELHI 110035 | NEW DELHI | NEW DELHI | DELHI | 110035 | L5 | Rejected-Finance Rejected due to highest rate quoted. |
Tender Value
₹49.5 L
EMD Value
₹99,000
Closing Date
27 Apr 2024, 6:00 pmClosed
GE (AF) GURGAON
GE (AF) GURGAON
REPAIR MAINT OF SPLIT WINDOW TYPE AV COOLING APPLIANCES AND AC PLANT 3X35 TR AT NTS AND REPAIR PERIODICAL SERVICES TO DG SET PCC 3.3 PLC APFC AMF PANELS AND OTHER CONNECTED WORKS AT NTS NCN UNDER GE AF GURGAON
2024_MES_648744_1
GE/GUR-/NIT-92/2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE (AF) GURGAON
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (AF) GURGAON
₹99,000
25 May 2024
30 Mar 2024
29 Apr 2024
30 Mar 2024
27 Apr 2024
13 Apr 2024
Amount
Material and labour for taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning/washing of cocling coil air Each job filters/plasma filters etc of Indoor unit & condenser, compressors, fan motor etc of Out door unit with vacuum cleaner OR cleaning solution Including checking the servicibility of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, remote control unit, fan. blower, etc and changing connections from heating mode to cooling mode or vice-versa and keeping the AC unit in satisfactory working condition complete all as specified and as directed. Note:-(1) Replacement of defective spares will be measured & paid separately under relevant items and Labour charges for fixing of new spares shall deemed to be included in unit rate quoted. (ii) Penalty will be charged for not attencing complaint from 6 hours to 12 hours Rs. 250/- and from 12 Hours to 24 hours Rs. 500/- each complaint. Further if complaint not attended and rectified within 24 hours after intimation (Intimation will be given by message/whats app/mail by mentioning time of complaint, for that contractor has to submit his authorised reps details for receiving complaint) of complaint, failing which same will be got rectified through spot quotation by job order by any other agency at risk and cost of the contractor.
Supply only following spare parts of split AC unit of cap 1.5Ton/2 Ton complete all as specified and as directed:-
Running capacitor 36 MFD Make: Bentex/Delcon
Running capacitor 45 MFD Make: Bentex/Delcon
Starting capacitor 100-120 MFD Make:- Bentex/Delcon.
Starting capacitor 120-150 MFD Make:- Bentex/Delcon.
Starting Relay 1022/ 1622 Make::- Renutral / Epcas/Asian
Starting Relay 2000 Make:- Renutral/Epcos/Asian
Overload Relay Make:- Renutral/Epcos/Asian
Thermostat switch 2059/2064/2054 Make:- Indfass/Danfoss fan blade for spilt Type A.C Cap 2/1.5 Ton
Condenser fan blade for spilt Type A.C Cap 2/1.5 Ton
Wiring kit for A.C split Type 1.5/2 TR
Remote control for split AC Cap 1.5/2 TR of make as per site requirement complete all as specified and as directed.
Supply & fixing in repairs main printed circuit board (PCB) with electric accessories and sensors suitable for split AC capacity 1.5/2 TR complete all as specified and as directed.
S & F in replacement suction and discharge valve set for Split AC 1.5/2 TR capacity of make as per exisiting at site complete all as specified and as directed.
Replacement of unserviceable PCBs from existing split type AC of 1.5/2TR capacity, and re-fixing with new proper functioning of the AC complete all as specified and as directed.
M&L for disconnecting from mains and taking out existing unserviceable sealed compressor unit from the sp it type Air Conditioner of Cap Eas 1.5 Ton of any model/make/type from any location and Supply, Installing and testing (in repairs) existing company made new sealed compressors with one year warantee including cleaning and rernoving dust/dirt from the cooling coll condenser coil with necessary modification capillary tube etc including Charging of Gas R-22 and commisioning complete all as specified and as directed. Make Kirloskar/Voltas/Blue star.
All as per item No. 03 above but spilt type Air Conditioner of Cap. 2 Ton Make Kirloskar/Voltas/Blue star.
M&L for Disconnecting from mains and Taking of unserviceable fan motor blower motor of split tyce AC 152 ton capacity of any make and type Em from any location and supply, installing and testing new motor of 1/4 HP or 1/2HP 920 RPM, 230 Volts or as per existing capacity and model complete all as specified and as directed. Make: AUE/Crompton Greaves Speed King/Cool Master Note Transportation Charges From side to trade workst op and back to criginal location after repair shall be deemed to be included in unit rate quoted.
Material and labour for disconnecting from mains and taking out unserviceable condenser couper coil of split Type AC of Cap 15 Ton/2 Ton Ea of any make and type from any location and supply, installing and testing in repairs new condneser coil as par existing capacity and make complete all as specified and as directed.
S & F in repairs evaporator/cooling coil of split type AC of capacity 1.5 TR 12 TR of existing make and size complete all as specified and as directed.
Maternal and labour for taking down unserviceable outdoor unit of split AC of any make type any capacity & supply & fixing nevi outdoor unit E suitable for 1.5/2TR capacity complete all as specified and as directed.
Taking down unservice sble indoor unit of split AC of an, make type and capacity & supply & fixing new indoor unit suitable for 1.5/2TR E capacity complete all as specified and as directed. Maks LG//Voitas/Cam.pro/Godrej
Taking down unserviceable copper pipe of size 1/4" and supply & fixing new copper pipa refrigerant tubing 1/4" for suction /discharge includ ng insulation tubing 1/4" complete including brazing, welding, with bolts and screws c' reqd size complete all as specified and as directed.
Taking down unserviceable copper pipe of size 1/2" and supply & fixing new copper pipe refngerant tubing 1/2" for suction/discharge includ ng insulation tubing 1/2 complete including orazing, welding, with boils and screws of read size complete all as specified and as directed.
Material and labour for taking down unserviceable PVC drain pipe and supply & fixing new PVC drain pipe 15 mm dia for Split/window AC complete all as specified and as directed.
Material & labour for detecting the leakages of gas of split type AC of capacity 1.5/2 TR at any location and rectifying the defect to stop the leakage by gas welding or charging of refrigerant gas R-22/R-134A in window type /Split Type AC unit of capacity 1.5/2TR including testing and commissioning complete in satisfactory working condrion by any other means and making it fully functional complete all as specified and as directed.
Taking down unserviceable contactor and supply and fixing new contactor single phase suitable for Split AC 15 to 2.0 TR complete all as specified and as directed.
Supply and Fix Metal clad socket outlet with single pole and nuetral enclosure with two pin and earth plug socket complete with one single pole MCB 20-32 Amps including taking down old/unsv Metal clad socket complete all as specified and as directed.
Supply and fix MCB single pole, 240 volts, 5 to 40 Amps 13 KA complete including taking old unservicable MCBs of any type/capacity complete all as specified and as directed.
Supply & Fixing in replacement Metal clad Plug ISI Marked complete all as specified and as directed.
Supply & Fixing in replacement Metal clad Socket complete all as specified and as directed.
M&L for shifting of split AC 1.5/2 00 TR including dismantling all accessories, indoor outdoor unit and copper insulation, voltige stabiliser and ninstalling the all acessories at new location as directed the coat of new copper pipe suction and discharge including insulation and electr: cable 3 core 4 Sqmum as per site requirement in included in the quoted rate complete all as specified and as directed.
M&L for 3 core flexible PVC ensu ated cord sheathed 4.00 Sqmm including connection complete all as specified and as directed.
M&L for taking down for servicing unserviceable voltage stabilizer of capacity 4 to 5 KVA from the site and transporting to E contractors workshop for locating the fault including checking the servicibility of electrical electronic circuits relays and repalcement of defective spare parts, vassembling after making connections, testing by applying low and high voltage input to get the 230 volts correct output and transporting back the same to site complete all as specified and as directed. Note: Replacement of defective spares and rewinding of transformer of voltage stabilizer will be measured & paid separately under.
Supply only following defective spare parts of Voltage stabilizer of Cap 4 to 5 KVA complete all as specified and as directed:-
Voltmeter (Anlog) 0 to 330 voits any type shape single phase 50 Hz AC supply.
Digital type Voltmeter 0 to 300 volts any type shape single phase 50 Hz AC supply.
Printe circuit control card suitable for 4 to 5 KVA.
Nput/cutput switch Maka AE/Rishabh/Mico.
Push on switch Make AE/Rishabh Mico.
Indicator complete with bulbs Make Renutrol/Technomac .
Trigger Transformer for 4 to 5 KVA.
Relay for4 to 5 KVA voltage stabilizer Make Renutral/Technomac.
Time relay .
Material and labour for taking out the burnt winding of transformer of voltage stablizer and prepaining core after cleaning by suitable cleaning agent and rewinding the transofmer of voltage stablizer with super anameld copper wire of existing gauge including varnishing, heating complete all as specified and as directed.
All as per item No 23 above but 5 KVA complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 190 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 300/310 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 40/80 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 60/120 Lirs capacity rafrigerators complete all as specified and as directed.
Dismantling and removing defective compressor and replacing the same with new sealed compressor of approved make cotained from author sed dealers for 150 Lirs capacity rafrigerators complete all as specified and as directed. Note FOR ITEM No. 25 to 29 here as above:- (1) Warranty certificate from manufacturer/authorised dealers shall be submitted alongwith compressor unit. ( Supply and charging of gas will be measured and paid separately under relevant item.
Supply and charging religerant cas non CFC based compatible to F-22/134 in refngerators of capacity 180/300/310 Ltrs capacity complete all as specified and as directed.
Supply and charging refrigerant gas nox CFC based compatible to F-22/134 in water coolers of capacity 40/80 Lirs capacity including 4 cutting and brazing of copper tubes complete all as specified and as directed.
Supply and charging refrigerant gas non CFC bared compatible to F-22/134 in water coolers of capacity froin 60/120 Lims to 150/150 Lis capacity including cutting and brazing of copper tubes complete all as specified and as directed.
Supply and fix in replacement capilary tube of existing size including necessary brazing suitable for 180/315 Lins capacity refrigerator complete all as specified and as directed.
Supply and fix in replacement over load protector relay su table for 180/300/310 Ltrs capacity refigerator complete all as specified and as directed.
Supply and fix in replaciment thermostat suitable for 180/100/310 Lirs cap waty refrigerators complete all as specified and as directed.
Supply and fix ir replacement over load protector relay su able for 40/80 Les capacity water cooler complete all as specified and as directed.
Supply and fix in replacement the mostat suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix irreplacement condensor motor fan blade suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in replacement new condensor motor 1/32 HP with fan blades complete suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in replacement PVC drain pipe 25mm da with suitable standard clip complete to fix with water cooler of any capacity including dismantling the old unserviceable one complete all as specified and as directed.
Supply and fix in replacement PVC connecting pipe 20mrt dia and 1.5 Mtr length for inlet to water cooler with both side threaced sockated type complete all as specified and as directed.
Supply and fox in replacement drain water tray compite suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in replacement chromium plated bib cock push type outer/innar threaded suitable for 40/80/120/150 Ltr capacity water coolers complete all as specified and as directed.
Supply and fix in repairs PVC float valve of size 15mm dia complete su able for socke: of same size complete all as specified and as directed.
Supply and fix in repains freezer door with spring of refreginrators of any capacity & make complete all as specified and as directed.
Supply and foxing in replacement vegetable basket with glass suitable for 183/300/310 Ltrs capacity refrigerators complete all as specified and as directed.
Supply and fixing in replacement PVC defrost tray as per sample suitable c 180/300/310 Ltris capacity refrigerators complete all as specified and as directed.
Supply and fixing in replacement door gasket for refrigerators of capacity upto 180 to 310 Ltra complete all as specified and as directed.
Dismantling of existing repairable deep freezers of any make and from its position after disconnecting electric connections, transporting from site to contractor's workshop fro carrying out repairs and renewal/replacement of parts, re-assembling and transporting back to the site includ ng installation of the same on the same location and making electric connection etc, complete all as specified and as directed. Note: Parts renewed shall be measured and paid separately under appropriate iterns.
Supply only starting relay upto 300/320 Lirs capacity deep freezer complete all as specified and as directed.
Supply only overload protector suitable for upto 300 Ltrs capacity deep freezer complete all as specified and as directed.
Supply only running capacitor for upto 300/320 Ltrs capac ty deep freezer complete all as specified and as directed.
Supply only thermostat suitable for upto 300/320 Ltrs capacity deep freezer complete all as specified and as directed.
Supply only starting capacitor for upto 300/320 Ltrs capac y deep freezer complete all as specified and as directed.
Taking down defective compressor of capacity 300/320 deep freezer of any make and supplying and fixing now sealed unit compressor a specified here under including brazing and with necessary nuts and bolts, copper filter, capilary and supply & charging of refrigerant ga Won C-C based or equivalent to Non CFC gas in required qty and testing complete all as specified and as directed.
M&L for taking down desert cooler of any type/size/mode from any height / floor for servicing like changing of wood wool pads, kit motor Eas submersible pump, fan blade, front grill, wining, capacitor, cleaning or any other repar work is specified and re-fixing to existing place after repair work/overhauling complete all as specified and as directed. Note (1) The rates quoted by the contractor shall deemed to include the cost of T&P (2) The items required to be replaced shall be measured and paid separately under rolevant items.
Supply only wood wool pad of suitable site for 24 sweep desert cooler complete all as specified and directed 01 Set comprising of 3 Nos of pad As per sample complete all as specified and as directed.
All as per item No 57 above but 20 sweep approximate weight 700-800 Gms As per sample complete all as specified and as directed.
Supply only submersible pump (tullu pump) motor 230 Volts, single phase, AC complete all as specified and as directed. Make-Little/ Cromptor/Khaitan
S&F in replacement of New fan motor with copper winding including suitable fan blade of existing capacity and size for desert coolers complete all as specified and as directed.
Supply only PVC front gril for desert cooler of approved make complete with 5 Amp switch, three speed regulator including indicating samp complete all as specified and as directed. (As per Samole)
Supply & fixing wire mesh for desert cooler pad (Set of Thee) complete all as specified and as directed.
Supply & fixing PVC pips for connecting pump and water distributor of size 15 mm dia. As per sample complete all as specified and as directed.
Supply & fixing PVC elbow for desert cooler As per sample complete all as specified and as directed.
Supply & fixing PVC 4 Way distribution cross for desert cooler As per sample complete all as specified and as directed.
S&F in repairs & replacement flexible copper conductor cable PVC insulated & PVC sheathed of size 14/1076 complete all as specified and as directed. (Make-Flaza/Kalinga)
S&F in replacement desert coolers fan blade of 18" (inch) sweep make out of Plastic/Aluminum complete all as specified and as directed.
S&F in replacement desert coolers fan blade of 20" (inch) sweep make out of Plastic/Aluminun complete all as specified and as directed.
Supply and fixing in repairs side panel of desert cooler of 20" (inch) sweep made out of 20 SWG, GI sheet suitable for fixing with the existing desert coolers, duly painted with synthetic enameled paint over a coat of red oxide primer complete all as specified and as directed.
S&F in replacement swich piano flush type single pole one way 5Amp 230 V for desert cooler complete all as specified and as directed.
S&F replacement 3 pin plug top 5 Amp. 230V for desert cooler complete all as specified and as directed.
S&F in replacement desert cooler body of size 26 inch x 25 inch x 32 inch (height) with side panels (03 Nos) (abricated out of 20 SWG PGI Sheet alongwith PVC front grill, distribution switch 5 Amp piano switch and depth of water tank not less than 7" (inch) complete all as specified and as directed.
M&L for evacuation of Gas from the systam feeding the dry nitrogen by separating the low and high side of the system and leuk testing the same arresting the leaks including S&F in replacement of Teflon sealing of all refrigerant no valves of compressors, gland packages of att angle valves fiaring of all connections framing welding angle valves flaing of all connectic is framing welding etc complete ncluding gas charging of Cenizal Type AC plant of capacity 3X 35 TR complete all as specified and as directed.
Supply and charging refrigerant R-22/R-32Gas of approved rake in new sealed cylinde complete all as specified and as directed.
Repair/maintenance/servicing complete unit of AHU's of AC plant 3X7.5TR Capacity system and cleaning of metallic finers and cooling coils with cleaning agent folowed with pressurized water jet at AFSSR including repair to niszzle and spraying pipe clamps and the rod replacement, cisaning at FRB shuts and fixing HW FRP cover to air motor complete all as specified and as directed.
Dismantling the existing water cooled condenser of Cap 3x7.5TR of shell and tube type from its pipe line and gas connection repairing the same by replacing the defective copper tubes by new one with existing size and dia, Cleaning the shell complete assembly the new and serviceable tubes charging testing for 350 PSI pressure complete all as specified and as directed. Note Rate quoted shall be inclusive of copper tubes.
S&F in replacement of thermostatic expansion valve of suitable for existing AC Plant 3x35 TR including cutting, welding brazing replacement nut bolt, washer of existing nake etc complete all as specified & as directed. Note for item Before disconnecting the existing expansion valve from the system the refrigerant has to be pump down or taken in empty cylinder by help of ICE etc.
S&F in replacement of temeperature gauges of the chiller and condenser linas operatas by mercury liquid of range 0-50°C complete all as specified and as directed. Make Fiebig
S&F in replacement of pressure gauges of the chiller and condenser lines ct range 0-250 P complete all as specified and as directed. Make Fiebig
M&L for repalcement of wom bearing No. 6308 for compresser motor 40 HP including replacement of coupling plate, bush nuts bolts complete accessories for smooth functioning and testing complete all as specified and as directed.
M&L for repair to control panel with replacement of contractor, relay timer switch starting switch complete wiring of panel and connection Replacement of imported controls pressure, switches gauges, modulating valves, modulating motors, microprocessor and BMS components of compressor unit 1 to 3 at 3x35R NTS complete all as specified and as directed.
Supply upply and fix in replacment butterfly valves suitable for Gl pipe complete incited finecting the old and nuts 100mm as per site replacmeent complete all as specified and as directed.
M&L for rewinding of induction Electric Motor upto 7 to 15HP Capacity of any Make and size complete with super enameled copper wire oF existing gauge including Varnishing and replacement of insulated material and replacement of ball Bearing complete all as specified and as directed.
&L for rewinding of compressor Electric Motor upto 50 HP Capacity of any Make and size complete with super enameled copper wire c existing gauge including Vamishing and replacement of insulated material and replacement of ball Bearing complete all as specified and as directed.
M&L for repairing the cooling tower of AC Plant 3x35 TR at NTS by Strip opening of the parts such as CT fan motor, fan, fan blades, PVC fins, sprinkler, tie rod eliminator, electric connection complete and removing silt deposited inner part of the cooling tower by wire brush, PVC branch pipe and applying solvent as applicable and refixing the same after repairs/modification etc all as specified and as directed.
Supply and fix in replacement of ON Load changecver switch confirming to IEC 947-3, EN-60947-3, AC-23A, Front operated, 4 pole 415 volts, 50 Hz 400 Amps, in sheet metal er closer complete all as specified and as directed.
S&F Power Contactor MNX-8 with Aux contacts 1 NO +1 NC of range AC1-32 A & AC3-18 A complete all as specified and as directed.
S&F Power Contactor MNX-25 with Aux contacts 1 NO +1 NC of range AC1-45 A & AC3-25 A complete all as specified and as directed.
S&F Power Contactor MNX-40 with Aux contacts 1 NO +1 NC of range AC1-55 A & AC3-40 A complete all as specified and as directed.
S&F Timer Electronic type 240/415 volts complete all as specified and as directed.
S&F single phase preventer suitable for 3 HP 50 HP pump sets complete all as specified and as directed.
S&F in replacement MCCB 125 A 4 pole, 35/36 (A with adjustab a thermal & fixed magnetic setting with bus bar sprieder links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as directed.
M&L for Carry out 'C' check from authorised rep or service engineer from the manufacturer of DG set of 2X750 KVA capacity with replacement of oil filter,Diesel filter & related accessories such as set of 'O' ring, set of joint /gasket, Set of Copper washer,Set of Fuel Flexible Pipe,Set of cogged belt, Set of Hoses, Instrument fuse, Battery maintenance, descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air, or water. Make : Cummins ( excluding the cost of the following spares all as per OEM & specified andas directed. Note :- Supply of Spares shall be measured & paid seperatly.
Supply only Element Lub oil filter (cat part No.3238204)
Supply only Kit fuel filter and Ring. (cat part No.3238493)
Supply only Kit super by pass filter element (cat part No.3879488)
Supply only SEAL 'O' Ring (cat part No.3010937)
Supply only Engine oil, VALVOLINE PREMIUM BLUE 7800 PLUS1/210 Ltr (Cat Part no. 504626)
Supply only air cleaner element (K, QSK, V series) (Cat part no. 3238665)
Supply only INHIBITOR CORROSION 1/ 10 Ltrs (cat part No.3167222)
Supply only STRIP TEST (cat part No.4912590)
Supply only Gasket Rocker Lever Cover (Cat part No. 4920076)
Supply only Seal O Ring (Cat part No. 3066914)
Supply only Seal O Ring (Cat part No. 3042542)
Supply only Coolant for radiator
Supply and fixing New AVR VARIABLE SPEED DCDG suitable for DG set with input voltage range 415 Volt AC with neutral & Out put DC voltage suitable for DG set of 750 KVA complete all as specified and as directed.
Disconnected and opening of self starter assemlly 12/24 volt for repair from DG set of 750 KVA & repair unserveceable part of self starter suitable size as required on site complete all as specified and as directed. Note :- Supply of Spares shall be measured & paid seperatly as under:-
Supply only Armature.
Supply only Solenoied switch
Supply only Bush gear
Supply only'O' Ring assy.
Supply only Bush set.
Supply only FIELD Coil
Supply only Sealing kit.
Supply only Brush Set
Supply only the following items of DG Set of various capacity complete all as specified and as directed :-
Battery terminal, lug, bolts type suitable for heavy duty battery.
Battery leads of copper conductor multiwired 70 Sqmm Single Core.
Hinges for DG set door of any size, any type as required on site.
V belt for fan pulley for DG set of 750 KVA DG Set complete all as specified.
Fuel hose pipe from fuel filter to fuel pump for DG set of 750 KVA.
Fuel pipe from fuel tank to fuel filter for DG set of 750 KVA.
Material & labour for carrying out complete servicing of DG set (750 KVA) PCC3.3 digital panel(power command), including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, repairing of PCC3.3 card , making all electric connections and testing for smooth operation, complete all as directed.
Supply & fixing following parts of PCC3.3 digital panel of 750 KVA (Make: Cummins) DG Set complete all as specified and as directed:-
PCC3.3 Control card (cat part No.A054J968)
Display control (cat part No.0300-6315-02)
Aux card- (cat part No.A028T766)
PCB assy Governor Card (cat part No.0327-1507)
M&L for maintenace/testing of RTCC panel by isolating, disconnecting of input/output , supply cable, detecting of fault, ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out auto/manual switches LED indicator, cost of spare parts complete all as specified and as directed. (repacement of spare parts not to be paid separately .
M&L for maintenace/testing of PLC panel by isolating, disconnecting of input/output , supply cable, detecting of fault, ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out auto/manual switches LED indicator, complete all as specified and as directed. Note: (i) Parts not mentioned in above description will be paid separately as supply only but to be fixed under above items.
Supply only following spares parts for PLC Panel complete all as specified and as directed.:-
SMPS, input 220 V, output 24 V DC, 10 Amp
Transformer 415 to 24 volt,25 amp
Multifunctional meter wit MMI suitable for existing PLC Sytem
Auxiliary contact suitable for existing PLC Sytem
Thermal relay suitable for existing PLC Sytem
M&L for maintenace/testing of VRV panel by isolating, disconnecting of input/output , supply cable, detecting of fault, ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out auto/manual switches LED indicator, complete all as specified and as directed. Note: Parts not mentioned in above description will be paid separately as supply only but to be fixed under above items.
Supply only following spares parts for VRV Panel complete all as specified and as directed:-
Transformer 500 VA
63 amp TP MPCB, 16 KA
M&L for maintenace/testing of PAC panel by isolating, disconnecting of input/output , supply cable, detecting of fault, ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out auto/manual switches LED indicator, complete all as specified and as directed. Note: Parts not mentioned in above description will be paid separately as supply only but to be fixed under above items.
Supply only following spares parts for PAC Panel complete all as specified and as directed.:-
Single phase preventer
Auxiliary contact 9 amp suitable for existing PLC Sytem
Capacitor upto 10 KVAR
Adujustable MPCB upto 20 amp ,10/16 KA
M&L for maintenace/testing of MDB panel by isolating, disconnecting of input/output , supply cable, detecting of fault, ,u/s component in panel ,cleaning of serviceable parts/ component ,including replacement of worn out auto/manual switches LED indicator, complete all as specified and as directed.
Supply, laying, jointing and testing XLPE insulated, PVC outer sheathed, galvanised steel strips armoured, heavy duty power cable with aluminium conductor suitable for rated voltage of 1100 Volts grade earthed system and conforming to IS : 7098 of 1995 and of size 3.5 core X 300 Sqmm and laid in trenches/ducts/pipe or on poles complete all as specified and as directed.
All as per item No 107 above but size 3.5 core X 150 sqmm
All as per item No 107 above but size 3.5 core X 25sqmm
All as per item No 107 above but size 4 core X 16 sqmm
All as per item No 107 above but size 4 core X 10 sqmm
Supply ,jointing and testing straight through , cold shrinkable joint kit suitable for PVC/XLPE insulated heavy duty armoured with aluminium multi stranded conductor 1100 volt grade of size 16 sq mm 4 core and including taking out from faulty portion in any situation /position complete all as specified and as directed.
All as serial item No-112 here in before but of size 25 Sqmm 3.5 core.
All as serial item No-112 here in before but of size 150 Sqmm 3.5 core.
Excavation in trenches not exceeding 1.5 mtr and n.exc 1.5 mtr depth in any of soil complete all as specified and as directed.
S & F Bricks Burnt clay fly ash building bricks having compressive strength 75 Kg /Sq cm laid in trenches for cable protection complete all as specified and as directed.
S&F sand in trenches including spreading & levelling for cushioning of LT UG cable complete all as specified and as directed.
Returning filling in including spreading, levelling watering and well ramming in layers n.exc 25cm thick complete all as specified and as directed.
Removal of excavated material to a distance n exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Arranging fault locating machine to pin point the fault in any size of HT/LT under ground cable in any situation , taking out the fault portion of HT/LT Cable of any length from trench , jointing with cable jointing kit and testing for satisfactory serviceability of the HT/LT cable in trench after jointing . Including excavation and earth work in any type of soil complete all as specified and as directed. Cable jointing kit shall be measured sepereatly under respective item of Sch 'A'. Retrived old servicable bricks /cable cover willbe relaid in trenches on the cable
S & F Frequeny meter flush type 3 phase 415 volts AC including removing old meter complete all as specified and as directed.
S & F Volt meter of 0-500 Volt, 415 Volt Ac connecting testing including removing of unserviceable meter complete all as specified and as directed.
S & F Ammeter 0 -3000 A with CT Coil,415 Volt Ac connecting testing including removing of unserviceable meter complete all as specified and as directed.
Disconnecting the existing unservicable /burnt MCCB from the LT panel /stand by DG set panel & Supply & fixing new MCCB ,3 pole ,630 Amp(DN3-630N),50 KA,415 volt,50 Hz, 3 phase,Ics=100% of Icu with thermal magenatic release,installation of MCCB and connecting with existing cable including nut,bolt and washer etc complete all as specified and as directed.
All as serial item No 124 here in before but of size 400 Amp(DN3-400 N) 50 KA
All as serial item No 124 here in before but of size 200 Amp, 36 KA
All as serial item No 124 here in before but of size 160 Amp, 25 KA.
All as serial item No 124 here in before but of size 100 Amp,16 kA
All as serial item No 124 here in before but of size 63 Amp, 16 KA .
S & F in replacement of 10 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following single pole complete with connection testing complete all as specified and as directed.
S & F in replacement 63 amp TP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles complete with connection testing complete all as specified and as directed.
S & F in replacement 32-40 amp TP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles complete with connection testing complete all as specified and as directed.
Disconnecting the existing unservicable /burnt ATS from the PAC panel & Supply & fixing new ATS ,400 Amp, 3/4 pole ,415 volt,50 Hz, 3 phase with automatic /manual with inbuilt time delay and connecting with existing cable including nut,bolt and washer etc complete all as specified and as directed.
Repair&servicing of 12V, 180AH Battery including replacement of any part to make it serviceable Any Make battery complete all as specified and as directed.
M & L in replacement for Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including using galvanised iron strip 32×6mm as earthing strip by means of bolts, nuts, check nuts and washers of galvanized iron or steel, earth plate surrounded by packed layer of char coal dust and common salt, 15cm thick all around bottom and top and watering pipe 20mm bore of GI light grade with funnel, wire mesh and 40 mm dia GI protection pipe medium grade all as shown in electrical plate No 3 of SSR Part-I and connected to earthing test point, main switch board and testing on completion including excavation, earth work concrete pit with 80mm thick RCC cover in RCC 1:2:4 type B-1 duly reinforced with MS bars 8mm dia @ 150C/C both ways and pit chamber in PCC 1:2:4 type B-1 with 2 Nos suitable lifting handles of 12mm MS bar complete all as specified and as directed.
Supply and lay in trenches GI strip 25 mm x 4 mm galvanised iron strip for earth continuity earthing complete all as specified and as directed.
Material & labour for carrying out complete overhauling / servicing of DG set panel / AMF panel / control panel, including checking and rewiring faulty electrical circuit using 1.5 sqmm FRLS copper conductor, Relay, fuse, timer, for DG Set of any type / make / capacity, making all electric connections and testing for smooth operation,complete all as specified and as directed.
S&F in replacement of power contactor 4 pole 200Amp model no MCX-33 of L&T or equivalent out of makes spd in list of makes complete all as specified and as directed.
M&L for drilling hole under hard standing /road in different location as per site requirement (between 03 mtr to 12mtr maximum) for laying of pipe for protection of cable etc by means of mannual bookle and without disturbing the top surface and making good the disturbed surface if any complete all as specified and as directed.
Supply and laying GI tube medium grade 80 mm bore, ISI marked complete all as specified and as directed.
Supply and laying GI tube medium grade 40 mm bore, ISI marked complete all as specified and as directed.
S&F in replacement of MCCB with adjustable thermal & fixed magnetic setting with bus bar spreader links for connecting both incoming and outgoing cables with suitable connections with suitable size of glands etc complete including testing & commissioning complete all as specified and as directed as per existing model/make of the following sizes:-
(a) 100 Amps 4 Pole breaking capasity 35/36 KA .
(b) 125 Amps 3 Pole breaking capasity 35/36 KA .
(c) 160 Amps 4 Pole breaking capasity 35/36 KA .
(d) 200 Amps 4 Pole breaking capasity 36 KA .
(e) 200 Amps 3 Pole breaking capasity 36 KA .
(f) 250 Amps 4 Pole breaking capasity 36 KA .
(g) 250 Amps 3 Pole breaking capasity 36 KA .
(h) 400 Amps 4 Pole breaking capasity 36 KA .
(i) 400 Amps 3 Pole breaking capasity 36 KA .
(j) 630 Amps 4 Pole breaking capasity 50 KA .
(k) 630 Amps 3 Pole breaking capasity 50 KA .
Supply, fixing and erection in replacemnt of steel tubular swaged pole type 410SP-31(9 Mtr long) Swan neck complete with CI base plate,taper plug,bolts,nuts,and screws etc duly painted internally and externally with metal oxide anti corrosive paint before errection and painting with two coats aluminium paint after erection complete all as cofirming to IS 2713 (part-1 to 111) complete all as specified and as directed. Note : Necessary earth work and concrete shall be measured and paid separately
M&L for Foundation for Tubular swaged pole type including excavation , getting out, pole foundation with PCC (1:4:8) type D 2 (using with 40 mm graded crushed stone aggregate). Coping of pole with PCC (11:3:6) type C ( using with 20 mm graded stone agregate) and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and as directed.
S&F in replacement for Changeover switch of capacity 250 Amps , 415 Volts , 4 pole with sheet metal inclosure complete all as specified and as directed.
S&F in replacement for Changeover switch of capacity 400 Amps , 415 Volts 4 pole with sheet metal inclosure complete all as specified and as directed.
S&F in replacement for Changeover switch of capacity 630 Amps , 415 Volts , 4 pole with sheet metal inclosure complete all as specified and as directed.
Supply & fixing in replacement of old unservicable feed pump for fuel injection pump complete assy for capacity 750 KVA of DG set complete all as specified and as directed.
Supply & fixing in replacement, of fuel shutoff valve assy , solenoied valve kit including taking outold valve assy and making all connection, testing for smooth opreation complete of all DG set capacity 750 KVA complete all as specified and as directed.
S&F element Air cleaner,inner for DG set 750 KVA complete all as specified and as directed.
Material & labour for opening / taking out of injector of DG set of any type/make and capacity 750 KVA disconnection and opening of fuel injector assembly, carrying complete overhauling/servicing fuel injection system with including replacement of injector repair kit ,including calibration of injector, checking of pressure complete for each injector and re-assembling the same, fitted with DG set properly in original location, checking the allignment, making proper fuel connection, testing for smooth opreatio complete all as specified and as directed.
S&F in replacement of old un/sv lifting magnet of existing make suitable for 750 KVA DG set complete all as specified and as directed.
S&F in replacement of unsv thermostat with new thermostat alongwith complete assy for DG set of various capacity , including all connection testing complete all as specified and as directed.
Supply and fixing, in replacement of Old unserviceable water temp meter complete all as specified and as directed.
Supply and fixing, in replacement of Old unserviceable OIL PRESSURE METER complete all as specified and as directed.
Supply and fixing, in replacement of Old unserviceable OIL TEMP METER complete all as specified and as directed.
Supply and fixing, in replacement of Old unserviceable H.C.T. SWITCH complete all as specified and as directed.
Supply and fixing, in replacement of Old unserviceable LLOP SWITCH complete all as specified and as directed.
Repair of door by removing and replacement of damage hinges,acoustic material and providing / fixing of glass wool,tissue paper, MS perforated sheet with painting complete all as specified and as directed.
Supply and fixing, in replacement, of Automatic Voltage Regulator (AVR) suitable for DG Set of 750 KVA capacity, with and including taking out old AVR and making all connection, testing for smooth operation complete all as specified and as directed.
Supply & fixing in replacement of battery charging unit including rectifier unit , voltage regulator,two Nos clamp,,nuts, bolts and suitable length of stranded copper conductor PVC cable 2.5 sq mm 3 run from power point to battery charger and 2 run fro battery charger to battery etc suitable for 12 volt battery charging unit complete all as specified and as directed.
Taking out and replacement of unservicable/blocked residential silencers of existing make suitable for 100 to 200 KVA and cutting welding and fixing of pipe complete all as specified and as directed.
Labour for attending of any breakdown of standby supply in any location ,whenever required round the clock ,rectify the fault and restore the standby supply within three hour after receipt of complaint of any nature i.e. Engine, alternator,control panel,AMF panel etc complete all as specified and as directed. Note -(i) The cost of replaced spare parts will be paid and measured seperatly. (ii) If complaint is not attended by contractor with in three hour the penality of Rs 500 / per hour to be imposed and amount of penality will be deducted from RAR. (iii) The cost of transportation (to and fro) for all kind of necessary equipment / T&P shall be arranged/brought by contractor to complete the job at site or at E/M yard and no extra cost shall be paid to the contractor to this effect. (iv) Complaint shall be lodged by telephonically ,so contractor to specify the telephone no who will receive the complaint round the clock.
M&L for capacity 750 KVA complete descaling of cooling system by radiwash with two times circulation of radiwash by means of running of engine & cleaning of fan blades, crankcase breather, radiator and its fins by means of high pressure air or water complete all as specified and as directed.
Supply & filling distilled water in sealed packing suitable for DC 12 volt battery complete all as specified and as directed.
Supply & Fixing in repalcement of 630A, Electrically operated Draw-out type ACB 3 pole fixed type with Microprocessor basedSR18G relay with protection aganist over current, earth fault and short circuit, 50KA=Icu=Ics=Icw for protection against common outgoing of change over switch complete all as specified and as directed.
Supply & Fixing in repalcement of 1250A, Electrically operated Draw-out type ACB 4 pole fixed type with Microprocessor basedSR18G relay with protection aganist over current, earth fault and short circuit, 50KA=Icu=Ics=Icw for protection against common outgoing of change over switch complete all as specified and as directed.
YASHVI ENGINEERS
D P ENTERPRISES
M/S PARKASH ENTERPRISES
SNOWY ENGINEERING INC
Chaudhary Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .