Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.3 LAccepted-AOC RZ H 5 NANDA BLOCK MAHAVIR ENCLAVE PART 1 PAL AM SOUTH WEST DELHI DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Awarded | |
| 2 | L2₹30.3 L+₹2.8 L (10.1%)Rejected-Finance | L2 | Rejected-Finance Rejected | |
| 3 | L3₹38.8 L+₹11.4 L (41.4%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L3 | Rejected-Finance Rejected | |
| 4 | L4₹39.8 L+₹12.3 L (44.8%)Rejected-Finance | L4 | Rejected-Finance Rejected | |
| 5 | L5₹40.0 L+₹12.5 L (45.6%)Rejected-Finance | L5 | Rejected-Finance Rejected |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
28 Jun 2023, 6:00 pmClosed
GE (AF) Subroto Park
GE (AF) Subroto Park c o 56 APO
REPAIR TO ROOF TREATMENT, CHAJJA, PARAPET WALL, INTERNAL/EXTERNAL PLASTERING AND CERTAINS MISC WORK AT SMQ AREA,CIVIL ZONE AND MES COLONY OF CAMERO COMPLEX AND REPAIR/REPLACEMENT AND MAINTAINANCE OF UG CABLES LT PANELS FEEDER PILLAR BOXES PANEL
2023_MES_600431_1
GE/SP/ TOKEN-43/2023-24
Open Tender
Civil Works
Item Rate
120 days
Subroto Park Delhi Cantt
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE (AF) Subroto Park
₹98,000
Yes
11 Oct 2023
2 Jun 2023
5 Jul 2023
2 Jun 2023
28 Jun 2023
16 Jun 2023
Amount
Taking out of APP modified water proofing membrane including mud puska complete on roof surface and surface properly cleaned by wire brush including removing of debries/domolished material obtained from roof out from defence land complete all as specified and as directed by Engineer-in-Charge.
M&L for preparation of plastered/concrete surfaces of roof and applying the under mentioned course of roof treatement complete all as specified and directed by Engineer-in-Charge.:- (a) Surface shall be throughly wire brushed, cleaned, washed, dried up properly and apply evenly a bituminuous primer coat conforming to IS @0.4 ltr /Sqm over concrete / plastered roof surface. (b) Applying evenly a tack coat of bitumen 85/25 grade @1.20 kg/ sqm. (c) Laying of 3mm thick APP membrane sheet (min weight 3 Kg/Sqm) consisting of a core of 160 gms/Sqm polyster non woven fabric mat protected on both sides with a high quality polymeric asphaltic mix again protected with thermo fusible HMHDPE FILM on dried primed surface by torch application method. APP membrane will normally be laid in length at right angle to the direction of slope. The over lap shall be minimum 100mm on longitudinal direction and 150mm on the transverse direction including cuttings, grooves etc. (d) Membrane bonded completely to the substrate & the over laps are then scaled/fused by flame. (e) Including 10mm thick rendering with 1:4 using WPC. (f) Painting with two coats of water proofing paint with aluminium finish. (g) PCC 1:2:4 type B0 (using 12.5mm graded aggregate) roof kerbs, benching rounded or chamfered on edge including rounded or chamfered edges with necessary form work etc complete Note:- This treatement shall be done by the approved authorized applicators and guarantte of treatement shall be for 10 years.
M&L PCC 1:2:4 type B1 using 20mm graded aggregate mixed with water proofing compound as per manufacturer instructions laid as in padding over roof slabs for providing proper slope to the concrete padding, surface finished even and smooth without using extra cement up to four stories complete all as specified.
M&L for cement contrete tiles 20cmX20CMX20MM thick wth grey cement and no pigment machine pressed; set jointed and pointed in neat cement slurry in floors and cut and polished including 20 mm thick screed bed or bedding layer of cement mortar (1:4), for laying of cement tiles on roof completed all as specified and directed by Engr-In-Charge.
M&L for guiniting work to RCC work in coloumn, chajjas, balconies, slabs, landings etc by removing loose, concrete, incl removing rust with short blasting and cleaning of surface with wire brush and applying epoxy treatment to rusted reinforcement and including S&F welded wire mess fabric or wire not less than 95x95x3mm adhesive plaster grade for concrete admixture and providing guniting pressure 2.00/2.50 Kg/Sq cm with admixture 1 part of cement and 3.50 part of sand and thickness 50mm average and making the surface even and smooth including necessary formwork and 10mm thick with CM 1:4 plaster over repaired surface with WPC complete all as specified and directed by Engr-in-Charge.
Demolition of brick work or stone/boulder masonry built in cement mortar up to four stories complete all as specified and directed by Engr In Charge.
M&L for brick work with subclass 'B' bricks, straight or curved on plan exc 6 M mean radius built in CM 1:6 complete all as specified and directed by Engr In Charge.
M&L Brickwork with sub- class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified and directed by Engr In Charge.
M&L for rendering CM (1:6) 15 mm thick on other than fair faces of brick work or concrete surfaces etc including finished even and smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M&L rendering 15mm thick in cement mortar 1:4 on other than fair faces of brick work or concrete surfaces finished even and smooth with using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
M & L rendering 10mm thick on ceiling in cement mortar 1:3 finished fair and even smooth without using extra cement up to four storey height bldg complete all as specified and directed by Engr In Charge.
Taking down cement or cement lime plaster on brick walls incl racking out joints hacking for key scrubbing down with water etc and removing the debries outside the MOD land up to four storey height bldg complete all as specified and as directed by Engr -in - Charge.
M&L for preparation of new surface and applying two coat of distemper on wall/ceiling over with 3mm thick JK/Birla wall care putty on walls complete all as specified and directed.
M&L for prepration of old plastered or unplastered surfaces of walls and applying two coat of approved shade of oil emulsion distemper with 3mm thick JK/Birla wall care putty on walls, including repairing of pot holes and cracks with putty, take it plaster where it required complete all as specified and directed by Engr-in-Charge.
M&L for preparing surfaces of new plaster on walls and applying exterior two or more coats of APEX/WEATHER over 3mm putty including priming coat of exterior primer applied complete all as specified and directed by Engr-in-Charge.
Material & Labour for prepration of old plastered or unplastered surfaces of walls and applying exterior two or more coats of APEX/WEATHER over 3mm putty including priming coat of exterior primer applied complete all as specified and directed by Engr-in-Charge.
Dismantling stone slab and granite of any description or thickness in floors etc and removing the debries outside the MOD land complete all as specified and directed by Engineer-in-Charge.
M & L 20 mm thick screed bed or bedding layer of cement mortar (1:4), for laying of granite complete all as specified and directed by Engr In Charge.
M&L pure black Granite (of any type) tiles 20mm (+-2mm) thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including moulded of edges grinding and polishing complete all as specified and directed by Engr-in-Charge.
M&L green Marble work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, windowcills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade to match the shade of marble stone including moulded ofnedges grinding and polishing complete all as specified and directed by Engr-in-Charge.
M&L Glazed ceramic coloured tiles in vertical surface 300X 450X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match incl back plaster 10 mm thick in cm 1:4 including dismentling complete all as specified and directed by Engr In Charge.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not xceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortar (1:4) including dismentling complete all as specified and directed by Engr In Charge.
Ditto as above item No-26 but as on vertical surface of wall such as skirting incl 10mm thick cement plaster (1:4) as in backing coat of tiles including dismentling complete all as specified and directed by Engr In Charge.
M&L Virified Ceramic light shade tiles 9 to 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match flooring( in any pattern) and jointed with neat cement slurry over 15 mm thick cement screed in CM 1:6 and pointed with coloured cement matching with surfaces of tiles as in floor including vertical surface of wall such as skirting incl 10mm thick cement plaster (1:4) as in backing coat of tiles and dismentling complete all as specified and as directed by Engr-In-Charge.
M&L for Chequered cement concrete tiles (rubber moulded with gloshy finishing) with grey cemet and pigments 30cm x30cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with 15mm thick bedding layer of cement sand mortar (1:6) including 100mm thik cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base for floors finishes including dismentling complete all as specified and directed by Engr In Charge.
S&F precast machine pressed PCC interlocking paver block of 80 mm thickness, M-40 grade of any shape and size confirming to IS -15658-2006 with grey cement and pigment as approved and 100mm thick plain cement concrete, type D-2, 1:4:8, (using 40mm graded stone aggregate) as in sub base flooring, surface finished even and rough to receive floor topping including sand cusion and dismentling complete all as specified and directed by Engineer-in-Charge.
M&L Machine pre polished cut kota stone slab 20 mm(+-2mm) thick in tread of steps, and similar over cement screed 20 mm thick in cm 1;4 base laid and jointed with grey slurry mixed with pigment to match the slab including rubbing 0ver CM 1:4:8 PCC 40MM thick and polishing as per up to four stories height and dismentling complete all as specified and directed by Engr In Charge.
.-Ditto-.but riser on stair case, skirting on walls etc incl the surface with . jointed with grey slurry mixed with pigment to match the slab including rubbing and polishing as per complete all as specified and directed by Engr In Charge.
M&L for cleaning of rotational moulded polyethylene water storage tanks any size or shape or capacity hoisted and refixed in same position including date of cleaning with enamel white paint and if required necessary fittings complete all as specified and directed by Engr In Charge.
M&L for removing rotational moulded polyethylene water storage tanks any size or shape or capacity hoisted and refixed in same position including necessary fittings with 20 mm dia Ball brass valves, high pressure, with polythene float and flynut including other fittings complete all as specified and directed by Engr In Charge.
S&F Rotational moulded polyethylene 500 Ltr water storage tanks as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings with 20 mm dia Ball brass valves, high pressure, with polythene float and flynut including dismantling water tanks exc 250 but not exc 500 ltrs capasity and removing to store complete all as specified and directed by Engr In Charge.
S&F Rotational moulded polyethylene 1000 Ltr water storage tanks as per IS (cylindrical vertical with closed top) hoisted and fixed in position including necessary fittings with 20 mm dia Ball brass valves, high pressure, with polythene float and flynut including dismantling water tanks exc 500 but not exc 1000 ltrs capasity and removing to store complete all as specified and directed by Engr In Charge.
S&F pre painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/clading to wall, fixed with self tapping screws as specification including dismentling complete all as specified and directed by Engr In Charge.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafter, purlins where connected to common rafters, running rails, grills, guides for sliding doors fixed with angle cleat and other connecting plates conforming to Fe-290 Grade E-165 including dismentling complete all as specified and directed.
M&L Preparation of new or old steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide/ zinc up to four storey height building chromate complete all as specified and directed by Engr In Charge.
M & L for 75 mm thick PCC 1:3:6 type C2 as in Plinth Protection using 40 mm stone aggregate including making joints & filling with sand bitumen mastic as per incliding dismentling complete all as specified and directed by Engr In Charge.
S&F in repair for 15mm bore steel water tubing medium grade , galvanized ISI marked with all fittings fixed to wall & ceiling or laid in floors including dismentling complete all as specified and directed by Engineer-in-charge.
All as per item No37 above but 20mm bore
Taking down rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and directed by Engr In Charge.
S&F for 75 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as percomplete all as complete all as specified and directed by Engr In Charge.
S&F for 110 mm dia pvc pipe Stack clamps out of 50 mm by 5mm flat iron and 16mm dia round iron stays,enlcuding bolts and nuts and securing ends of stays to wall or roof as per complete all as specified and directed by Engr In Charge.
S&F for PVC SWR bends 110 mm complete all as specified and directed by Engr In Charge.
S&F PVC SWR bends 75 mm complete all as specified and directed by Engr In Charge.
S&F for PVC (SWR) pipes 110 mm single socketed, in any length with solvent cement joints fixed to walls/laid in floors incl stack clamps of stainless steel with bolts & nuts etc complete all as specified and directed by Engr In Charge.
All as per item no.44 above but 75 mm dia..
S&F in repair pre painted galvalume aluminium zinc coating Gl based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering top of door/chajja/clading to wall, fixed with self tapping screws or fastner including all structure item/ members as required specification complete all as specified and directed by Engr in Charge
Taking down carefully copper/aluminium point wiring( light ,fan, socket or power) complete, fitting such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. Complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with single core of FRLS PVC insulated unsheathed ISI marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20 mm including conduit fittings and accessories concealed in wall / ceiling wiring in flush metal box alongwith outer cover plate for mounting modular/piano switch, socket and electronic regulator along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS ISI marked copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. For One light point/fan point/bell Point controlled by one switch one way.
All as per item No 48 above but for one 3 pin 5 amps socket outlet on indipendent board with switchs.
All as per item No 48 above but for one 3 pin 5 amps socket outlet on the same board with switchs.
All as per item No 48 above but with 2.5 Sq mm cable for Independent one 3 pin 15 Amps socket outlet In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring for one light / one fan / one bell controled by one switch with 1.5 Sq mm PVC insulated copper conductor cable drawing in and including PVC Casing/capping or surface conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly with 3mm thick plastic laminated sheet cover complete as specified and directed by Engineer in Charge.
All as per srl item 52 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 52 above but for one 3 pin 5 amps socket outlet on the same board with switchs.
All as per item No 52above but with 2.5 Sqmm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
M&L for point wiring with 1.5sqmm PVC insulated unsheathed multi stranded copper conductor cable drawing in existing steel/PVC conduit with 1.5 Sq mm PVC insulated copper conductor cable for continuous earth wire connected to main earth dolly excluding 3mm sheet metal box and hylam sheet complete for light point/fan point/bell point controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 56 above but for one 5 pin 5 amps socket outlet on the independent board.
All as per item No 56 above but for one 3 pin 5 amps socket outlet on the same board with switchs.
All as per item No 56 above but with 2.5 Sq mm PVC insulated stranded copper conductor cable for one 3 pin 15 Amps socket outlet. In and including S/C 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR cable for continuous earth wire.
S&F in replacement switch piano, flush type single pole, one way, 6 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement Socket outlet 2 in 1, 5 pin,6 A, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement switch piano, flush type single pole, one way, 16 Amps, 240 volts all as specified and directed by Eng-in-charge.
S&F in replacement socket 16 Amps, 2 in 1, flush type all as specified and directed by Eng-in-charge.
Supply & fix in replacement bell push, flush type, 5 Amps, 240 volts all as specified and directed by Eng-in-charge. .
S&F in replacement Fan Regulator step type 120 watt, 240 volt complete.
S&F in replacement Modular Fan step regulator, 120W step type 120 watt, 240 volt complete.
S & F Modular switch 1 way 6A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 6A - 2/3 pin combined 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S&F Modular switch 1 way 16A, 1 modules suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
S & F Modular Socket, 16A 2 module, suitable for 240 volt AC Complete all as specified and directed by Engineer-in-Charge.
Supply and fix Modular bell push 1 Module 5 Amps suitable for 240 volt Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,2 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,3 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,4 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fix White cover plate with frame,8 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 3 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 4 module Complete all as specified and directed by Engineer-in-Charge.
S & F Modular metal flush box 6 module Complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed by Eng-in charge
Taking down the old white hylium sheet from the existing flash metal box and replacing new supper quality white hylium sheet of size 9" x 13" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 81 above but of size 8" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 81 above but of size 7" x 5" complete all as specified and as directed by Engineer-in-Charge.
All as per srl item 81 above but of size 5" x 5" complete all as specified and as directed by Engineer-in-Charge.
Taking down rusted sunkan metal box and fixing new metal box of 3 mm thick of size 9''x13'' with finishig of disturbed surfaced as directed by Engineer in charge.
All as per srl item 85 above but of size 8''x5'' with finishing of disturbed surfaced as directed by Engineer in charge.
All as per srl item 85 above but size 7" x 5" with finishing of disturbed surfaced as directed by Engineer in charge.
All as per srl item 85 above but size 5" x 5" with finishing of disturbed surfaced as directed by Engineer in charge.
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non- metallic PVC/metallic conduit incl 4.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire. Note: 3 runs of 4 Sqmm wire will be measure one unit
S&F in repair of sub main wiring with 2 single core 06 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non metallic PVC conduit incl 6.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire. Note: 3 runs of 6 Sqmm wire will be measure one unit
S&F in repair of sub main wiring with 2 single core 04 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in and incl rigid non metallic PVC conduit 25 mm dia incl 04 Sq mm PVC insulated single core copper conductor cable for continuous earth wire. Note: 3 runs of 4 Sqmm wire and 1 run of PVC condiut will be measure one unit
S&F in repair of sub main wiring with 2 single core 06 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in and incl rigid non metallic PVC conduit 25 mm dia incl 6.0 Sq mm PVC insulated single core copper conductor cable for continuous earth wire.Note: 3 runs of 6 Sqmm wire and 1 run of PVC condiut will be measure one unit
S&F in repair of sub main wiring with 2 single core 10 Sq mm PVC insulated unsheathed 1100 V grade copper conductor cable drawing in existing rigid non metallic PVC conduit 32 mm dia incl 10 Sq mm PVC insulated single core copper conductor cable for continuous earth wire. Note: 3 runs of 10 Sqmm wire will be measure one unit
Supply and fixing LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with flexible copper conductor cable of suitable size from ceiling rose complete.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with flexible copper conductor cable of suitable size complete.
Supply and fixing decorative LED wall light for reduced glare designed for use with energy saving LED light bulbs with 100 lumen/watt complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable from ceiling rose to terminal block, and testing complete all as specified and directed by the Engineer-In- Charge.
Supply and fixing round/square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up core flexible copper conductor cable of suitable size complete.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up driver with flexible copper conductor cases of suitable size complete.
Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete.
S&F in replacement electronic driver suitable for 24 to 48 watt suitable for 2x2 recess LED, 6000 K luminaire Complete all as specified and directed by Engineer-in-Charge. .
All as per item No 100 above but Suitable for 9 to 18W complete all as directed by Engr-in-charge.
Supply and fix in replacement lamp holder PVC/Poly Carbonate type suitable for LED Bulb with ISI mark complete all as specified and as directed by Eng-in-charge.
Supply anf fixing bell, AC, 230 volts, single pole
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 4 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 100 Amps =01 No MCCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement load line vertical distribution board 'A' frame made out of CRCA sheet,double door, surface mounting TPN 6 way 415 volts 200 Amps rated bus bar and stove enamels dust and vermin proof suitable forTP/FP 'A' frame MCCB of 100 Amps =01 No MCCB for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCB shall be measured and paid seperately.
S&F in replacement of fan capacitor with copper wire plastic body 2.5 mfd.
S&F in replacement of fan capacitor with copper wire plastic body 3.15 mfd.
S&F in replacement of rubber real for ceiling fan complete all as specified and directed by Engineer in Charge.
S&F in replacement of mild steel U clamps including 10 mm dia but, nuts, washers and split pin for ceiling fan complete all as specified and directed by Engineer in Charge.
S&F in replacement of mild steel fan hook made out of 12 mm dia mild steel round bar of suitable size as per existing hook as directed by Engineerin Charge.
S&F in replacement of upper louver conopy of ceiling fan of any sweep, make, modles & size as per existing complete as specified and directed by Engineer in Charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC)
Taking down carefully Exhaust fans after disconnecting all electrical connections of any size for minor repair/service/rewinding/greasing as directed by Engineer in Charge.
M & L for repair to exhaust fan/ of of any size ( 200 to 600 mm sweep) by replacing unserviceable ball bearing No 6201/6202/6203 including neccessary greasing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of exhaust fan heavy duty plastic body 200 mm sweep including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust fan heavy duty metal body type 225/230 mm sweep including necessary fixing arrangement for proper fixing in wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
All as per item No 116 above but size of exhaust fan 300 mm sweep complete all as directed by Engr-in-charge.
All as per item No 116 above but size of exhaust fan 450 mm sweep complete all as directed by Engr-in-charge.
S&F in replacement of wall mounting fan heavy duty 450 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of exhaust fan louvers fan suitable for 225/230/250 mm sweep including necessary fixing arrangement for proper fixing on wall as per site requirement complete all as specified and as directed by Engineer-in-Charge.
All as per item No 120 above but size of exhaust fan 300 mm sweep complete all as directed by Engr-in-charge.
Supply and fixing in replacement MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 8 way 230 volts double door. Note :- MCB shall be measured and paid seperately.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, 240 volts, 6 to 40 amps C Curve capacity.
Supply and fixing in replacement MCBs 10 KA breaking capacity, single pole, and neutral, 240 volts, 40 amps C Curve capacity.
S&F in replacement MCB TP 25 to 63 Amps 10 KA, 440 volt 50 Hz all as specified ans directed by engineer in- charge.
S&F in replacement MCCB FP 40 Amps 16 KA, 440/415 volt 50 Hz all as specified ans directed by engineer in- charge.
Supply and fixing in replacement MCCB four Pole 100 Amps, 415 volt thermal release bearing cap 16 KA suitable for the MCB DB above comlete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in replacement MCCB four Pole 125 Amps, 415 volt thermal release bearing cap 16 KA suitable for the MCB DB above comlete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of MCCB 160 Amps FP 415 volts 3 phase 50 HZ with fixed/adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 200 Amps FP 415 volts 3 phase 50 HZ with fixed/adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 250 Amps FP 415 volts 3 phase 50 HZ with fixed/adjustable Thermal & adjustable Magnetic setting of rapturing capacity 35 KA.
S&F in replacement of MCCB 320 Amps FP 415 volts 3 phase 50 HZ with Fixed/adjustable Thermal & adjustable Magnetic setting of rapturing capacity 36 KA.
Excavation in trenches in hard and dense soil n exc 1.5 mtr wide and n.exc 1.5 mtr in depth for laying of pipe,foundation for poles, stay, laying cables etc and getting out complete all as specified and directed by engineer-in-charge.
Returning filling in including spreading, leveling watering and well ramming in layers n. exc 25 cm in hard/dense soil complete all as directed by engineer-in-charge..
Removing excavated material n.exc 50 meters and depositing where directed at a level n.exc 1.5 meter above the starting point complete all as directed by engineer-in-charge.
M&L for Sand cushioning of cables provided with a layer of sand 8 cm deep before laying the cable and 15 cm depth after punning down and stretching the cable complete all as directed by engineer-in-charge.
Supply and laying well burnt sub class ‘B’ bricks old size as mechanical protection to under ground cables laying across the cable complete all as directed by engineer-in-charge.
Laying of old bricks received during earth excavation after keeping safe as mechanical protection to under ground cables laying across the cable complete all as directed by engineer-in-charge.
M&L for precast cement concrete block masonry with solid blocks,exceeding 10 cm in width and setting in mortar type B1, 1:2:4 using 20 mm graded aggrigate complete all as specified and as directed.
Material and labour for cutting of road/ hard standing up to a size not exceeding 20cm width and not exceeding 60cm in depth for laying of cable protection pipe including making good the disturbed road/hard standing by providing PCC (1:2:4) type B1 and block top with black bituminous upto existing surface level complete all as specified and as directed by Engineer-in-charge.
Supply and laying GI pipe light grade galvanized with all fittings laid in trenches or fix on wall for cable protection of 80 mm bore complete all as directed by engineer-in-charge.
All as per srl item No 141 above but size 50 mm bore copmlete all as directed by engineer-in-charge.
Disconnecting,removing & taking out faulty U/G cable off sizes from trenches,wall and ducts complete all specified and as directed
Supply, Laying, Testing and connecting cable XLPE insulated armoured heavy duty electric cable with stranded aluminium conductor 1100 volts grade cross section area of 300 sqmm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 144 above but size 185 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 144 above but size 70 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 144 above but size 50 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 144 above but size 35 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
All as per srl item No 144 above but size 16 Sq mm x 4 core copmlete all as directed by engineer-in-charge.
All as per srl item No 144 above but size 120 Sq mm x 3.5 core copmlete all as directed by engineer-in-charge.
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 240 to 400 sq mm all as specified and directed by engineer-in-charge.
Supply and fixing in replacement of aluminium thimble stud type suitable for size of cable 16 to 180 sq mm all as specified and directed by engineer-in-charge.
M & L in replacement FRP juction box including MCBs with front cover fixed with locking arrangement with suitable clamp/fixture on pole complete all as specified and directed by Engineer-in-Charge.
Material and labour for cleaning of Electric panel at rusted portion with sand paper and painting with synthetic enamel paint suaitable for metal complete all as specified and as directed by Engineer-in-Charge
Preparation of old painted surface of steel tubular swaged poles (9 to 11 meter long) and painting with one coat of aluminium paint including cleaning the acrylic cover and painting with black to 1.5 mtr height from top of PCC coping and marking pole numbers with one coat of synthetic enamel paint complete all as specified and directed by Engineer-in-Charge
Supply and fixing in replacement LED street light fitting 30/40 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. complete all as specified and directed by engineer-in-charge.
All as per srl item No 156 above but 60 watt
All as per srl item No 156 above but 80/90 watt
All as per srl item No 156 above but 120/150 watt
Supply and fixing LED flood light 50 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
All as per srl item No 160 above but 150 watt
M&L for earthing complete with GI earth plate electrode 60cmx60cmx6.3mm thick buried directly in ground (earth pit not less than 2.25 meter deep below normal ground level) with top edge of the plate not less than 1.5 meter below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of GI bolts, nuts, check nuts and washers earth pit surrounded by picked layer of coal dust and 15 mm thick mixture in equal ratio of magnesium sulphate & copper sulphate in all around bottom and top and watering pipe 20mm bore of GI medium grade with funnel all as shown in electrical plate NO 5 of SSR Part I (1991) and connecting to earthing test point, including CI cover, frame and PCC (1:3:6) type C-2 using 20mm graded stone aggregate as in earthing pit with CI cover and framing including necessary earth work etc, complete all as specified Note :- PCC chamber shall be constructed at least one meter away from building shall be provided in slanting manner. Note :- PCC pit cover shall be precast of RCC 1:2:4 type B-I 80 mm thick reinforced with XPM weighting not less than 4 Kg (sqm in liew of CI)
All as per item no. 162 above but using galvanised iron strip 25x4mm as earthhing lead
S&F in repairs 4mm dia GI wire. complete all as specified and directed by engineer-in-charge.
Material and labour for galvanised iron strip 25 X 4 mm with saddles and fixing screws and connected as per site requirement comlete all as specified and as directed by Engineer-in-Charge.
shakti construction
OMVIN ENTERPRISES LLP
Laxmi traders
Ashish Sehgal and Co.
Mahesh Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .