Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Awarded Being Lowest Bidder | |
| 2 | L2₹18.6 L+₹3.0 L (19.2%)Rejected-AOC PLOT NO 4 SUDARSHAN ROW RESIDENCY GAWADE MALA PIPELINE ROAD SAVEDI AHMEDNAGAR 414003 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414003 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹20.2 L+₹4.6 L (29.4%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | Rejected-Technical | - | Rejected-Technical Not Enlisted in appropriate Category |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
1 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer North Ahmednagar
Military Engineer Services Garrison Engineer North Nagar-Pathardi Road Opp Ahmednagar Fort Ahmednagar - 414002
Repair / Maintenance of cooling appliances under GE (N) Ahmednagar
2020_MES_363464_1
8442 / E8
Open Tender
Miscellaneous Works
Item Rate
270 days
Ahmednagar
Class E Cat c (i)
8 documents required · 8 mandatory
₹500
Yes
Garrsion Engineer North Ahmednagar
₹40,000
Yes
22 Sept 2020
24 Jul 2020
3 Sept 2020
24 Jul 2020
1 Sept 2020
14 Aug 2020
60 days
Amount
Supply and fix fan motor / condensor motor and replacing the same with new fan / condensor motor 230 Volts, 50 Hz, SP suitable for water cooler of capacity 40 / 80, 60 / 120 and 60 / 150 litres including connecting and testing as per existing make etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 (here-in-before) but of 230 Volts, 50 Hz, SP suitable for frost free refrigerator of capacity 286 / 300 / 310 litres etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 (here-in-before) but suitable for window type AC of capacity 1.5 / 2 TR etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 (here-in-before) but suitable for split type AC out door unit of capacity 1.5 / 2 TR etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 (here-in-before) but for split type AC in door unit 1.5/2 TR capacity etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 01 (here-in-before) but of 230 Volts, 50 Hz, SP suitable for deep freezer of capacity 205 to 310 ltrs cap etc complete all as specified and directed by Engineer-in-Charge.
Disconnecting burnt out compressor from existing electric and pipe line connections of Refrigerator of capacity 165 / 175 / 210 litres of any make, location, transporting and replacing the same with new compressor including connecting suction and discharge lines by copper brazing, pressure testing with the help of nitrogen gas and flushing out the oil in condensor cooling coil and as per existing make etc complete all as specified and directed by Engineer-in-Charge. Note : Gas charging will be measured and paid seperately under relevant item of this BOQ. Make : Samsung / LG / Godrej
All as per item No 07 (here-in-before) but Refrigerator of capacity 286 / 300 / 310 litres.
All as per item No 07 (here-in-Charge) but Water cooler of capacity 40 / 80 litres
All as per item No 07 (here-in-Charge) but Water cooler of capacity 60 / 120 / 150 litres
All as per item No 07 (here-in-before) but Deep freezer of capacity 205 to 310 litres
All as per item No 07 (here-in-before) but Window / Split type AC of capacity 1.5 TR
All as per item No 07 (here-in-before) but Window / Split type AC of capacity 2 TR
All as per item No 07 (here-in-before) but Cassette type AC of capacity 4 TR
Supply and charging only refrigerent gas of required HD i.e hydrocarbon, 134 a, R-22 or R-12 or any latest version for Refrigerators of capacity 165 to 310 ltr capacity including cutting copper pipe and sealing by brazing etc after charging gas as required and leak testing etc complete all as specified and directed by Engineer-in-Charge..
All as per item No 15 (here-in-Charge) but for Water coolers 40 / 80 to 60 / 120 ltr capacity
All as per item No. 15 (here-in-Charge) but for Window / Split type AC of capacity 1.5 TR capacity
All as per item No. 15 (here-in-Charge) but for Window / Split type AC of capacity 2 TR capacity
All as per item No. 15 (here-in-Charge) but for Deep freezer of capacity 205 to 310 litres
Supply & fix running/starter capacitor 2.5 / 3.15 / 4.0 / 6.0 mfd, 250 volts , AC, from cooling appliances etc complete all as specified and directed by Engineer-in-Charge. Make : EPCOS , Asian , Bajaj
All as per item No. 20 (here-in-beofre) but of 10.0/15.0 mfd
All as per item No.20 (here-in-before) but of 36.0/45.0 mfd
All as per item No. 20 (here-in-before) but of 40.0/60.0 mfd
All as per item No. 20 (here-in-before) but of 80.0/100.0 mfd
All as per item No. 20 (here-in-before) but of 50.0/60.0 mfd
Supply and fixing in replacement thermostat suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing etc complete all as specified and directed by Engineer-in-Charge. Make : Indofos , Johnson , honeywell
Supply and fixing in replacement over load protector suitable for window / Split type AC's, Water coolers, Refrigerators and Deep freezers of any make, capacity and model and testing etc complete all as specified and directed by Engineer-in-Charge. Make : Indofos, Johnson, honeywell
Supply and fixing in replacement box type relay or package assembly from Window type AC's of capacity 1.5 / 2 TR including testing etc complete all as specified and directed by Engineer-in-Charge. /Make : Renutral , Indofos , Godrej
All as per item No.28 (here-in-before) but for Split type AC's of capacity 1.5 / 2 TR
All as per item No. 28 (here-in-before) but for Refrigerators of capacity 165 to 310 litres
All as per item No. 28 (here-in-before) but Water coolers of capacity 40 / 80, 60 / 120 & 60 / 150 litres
All as per item No. 28 (here-in-before) but for Deep freezers of capacity 205 to 310 Litres
Supply and fixing in replacement 15 mm dia ball valve / float value of high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142 gms from water cooler of any capacity, make, location etc including connecting and testing etc complete all as specified and directed by Engineer-in-Charge. Make : Prayag or equivalent as approved by GE.
Supply and fixing in replacement Push cock, 15 mm dia, brass cromium plated ( SS 304 ) self closing type etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement 15 mm dia Stop valves, brass,chromium plated screwed down, high pressure,with crutch or butterfly handle, screwed both ends for iron pipe or for unions etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Stainless steel SS 304 water drain out tray for water cooler etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC connection 600 mm long with brass ends terminals suitable for water coolers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC pipe 32 mm dia for draining out waste water etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Fan blade set for water cooler fan motor etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Door light switch assembly of refrigerators of any model, type, size and capacity to suit the existing including connecting and testing etc complete all as specified and directed by Engineer-in-Charge..
Supply and fixing in replacement Lamp electric 230 vots, 50 Hz, 15 Watt, pin / threaded type of refrigerators of any model, type, size and capacity to suit the existing including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Lamp holder of refrigerators of any model, type, size and capacity to suit the existing including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Timer for refrigerator of existing specifications of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung
Supply and fixing in replacement Bimetal for frost free for refrigerator of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung
Supply and fixing in replacement Capiliary tube of refrigerators of any model, type, size and capacity to suit the existing including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Magnetic rubber gasket for refrigerator door of capacity 165 to 310 litres , of any model, type, size and capacity to suit the existing including connecting and testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung
Supply and fixing in replacement Copper tube 1/4" size for refrigerator, of any model, type, size and capacity to suit the existing including connecting and testing etc complete all as specified and directed by Engineer-in-Charge.
All as per item No 47 (here-in-before) but of size 3/8"
All as per item No 47 (here-in-before) but of size 5/8"
Supply and fixing in replacement Evaporative cooling coil for refrigerator of capacity 165 to 310 litres of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung
Supply and fixing in replacement Condensor coil for refrigerator of capacity 165 to 310 litres of any model, type, size and capacity including testing etc complete all as specified and directed by Engineer-in-Charge. Make : LG , Godrej , Samsung Note for Sl item Nos 47 to 51 : Gas charging shall be measured and paid separately under relevant item of this BOQ
Supply and fix Plug top 3 pin, 230 Volts, 6 Amps including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Anchor , Havells , Legrand
Supply and fix Plug top 3 pin, 230 Volts, 16 Amps including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Anchor , Havells , Legrands
Supply and fixing in replacement Refrigerator door to refrigerator of any capacity from 165 to 310 litres of any model, type, size including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Heater of any size to refrigerator of any capacity from 165 to 310 litres of any model, type, size including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Indofos , Denfos
Supply and fixing in replacement Air filter PVC type of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Fan blade of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement MCB,SP,32 Amps 230/240 Volts,50 Hz for existing window / split type air conditioners including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Sheet metal enclosure with 3 pin metal clad socket 32 Amps with metal clad plug top including 1 No MCB, SP of capacity 32 Amps for existing window / split type air conditioners ,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Legrand , Siemens , Hager
Supply and fixing in replacement PVC insulated cable 3 core 2.5 Sq mm, 1100 Volts grade copper conductor, multistranded including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Polycab , RR Kable , KEI
Supply and fixing in replacement PVC insulated cable 3 core copper conductor 1100 Volts grade 1.5 Sq mm for desert coolers including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Polycab , RR Kable , KEI
Supply and fixing in replacement Metal clad socket 3 pin 20 Amps, 230 Volts, with plug top 3 pin for existing window / split type air conditioners ,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 63 (here-in-before) but of 32 Amps
Supply and fixing in replacement Heatlion insulation pipe for wrapping copper tape duly fixed with polythelene type to suction and discharge lines for existing window / split type air conditioners 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Electronic card of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC flexible pipe 15 mm dia for desert coolers etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement PVC pipe 15 mm dia with all fittings of existing window / split type air conditioners of capacity 1.5 / 2 TR,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Khus Khus pads of suitable size to dessert cooler of capacity 3000 to 4000 CFM etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement Drum motor 230 Volts, 50 Hz, SP for desert cooler of any capacity,from any position, of any make including testing etc complete all as specified and directed by Engineer-in-Charge. Make : Signature , Modi , USHA
Supply and fixing in replacement Water pump, 230 Volts, 50 Hz, SP with discharge head of 1.87 m for desert cooler of any capacity etc complete all as specified and directed by Engineer-in-Charge. Make : Signature , Modi , USHA
Taking down/out old rusted mild steel body of Water coolers, AC's, Refrigerators and Deep freezers and replacing the same with new mild steel sheet, 1.6 mm thick including cutting to shape required,fabricating to size and shape by welding / brazing etc to replace deteroited portion of body to make it functional and spray painting to match with the existing surfaces including making necessary connections etc complete all as specified and directed by Engineer-in-Charge.
Taking down/out the fan motor from Desert coolers of any make, size,model and capacity, transporting to work shop, opening up, cleaning, taking out burnt winding etc , and rewinding of motor with superior quality of enamelled copper wire of same guage, re-assembling including over hauling of parts and fixing back the motor at the same or desired position including testing and making necessary connections to make it functional etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 73 (here-in-before) but of Window / Split type AC motors of capacity 1.5 / 2 TR
Taking down/out window / split type AC 1.5 / 2 TR capacity of any make,from existing postion, transporting and refixing at the new location including making necessary connections to make it functional etc complete all as specified and directed by Engineer-in-Charge. Note : Gas charging and/or parts if regd shall be measured and paid separetely under relevant item of this BOQ
Taking down/out from existing position window type AC's of capacity 1.5 / 2 TR , servicing the same by cleaning, dusting with blower, checking wiring, nuts, bolts, electrical contacts, tightening all loosend parts as required, setting grills and fan blades for proper functioning, oiling, greasing to moving parts and refixing to its original position and testing for smooth functioning etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 76 (here-in-before) but split type AC's of capacity 1.5 / 2 TR
All as per item No. 76 (here-in-before) but refrigrator & deep freezers capacity 165 ltrs to 310 ltrs including washing filters with water
All as per item No. 76 (here-in-before) but water cooler capacity 40 ltrs to 120 ltrs & desert cooler of any capacity upto 5000 cum including washing filters with water
Material & labour for preparing the surfaces by scrapping out the old paint and painting with one coat of synthetic enamel paint of existing quality paint to Refrigerator of capacity 165 to 310 litres by spray painting etc complete all as specified and directed by Engineer-in-Charge.
All as per item No. 80 (here-in-before) but to Water cooler of capacity 40 / 80, 60 / 120 and 60 / 150 litres
All as per item No. 80 (here-in-before) but to Window type AC of capacity 1.5 / 2 TR
All as per item No. 80 (here-in-before) but to Desert cooler of capacity 3000 / 4000 Cum per hour
Repair of voltage stabilizer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 4 / 5 KVA etc complete all as specified and directed by Engineer-in-Charge.
Repair of voltage stabilizer for automatic opration single phase naturally air cooled indoor type and desinged for input variation b/t 170 v to 280 v with output voltage stabilized at 230 v with accuracy of + 2.5 % and of capacity 0.5 KVA to 2 KVA etc complete all as specified and directed by Engineer-in-Charge.
Detecting gas leakage of refrigerators, water coolers, deep freezers, window type AC's and split type AC's and rectifying/arresting the leakages,testing for pressure drop etc complete all as specified and directed by Engineer-in-Charge. NOTE: Gas charging shall be measured and paid separately under relevant item of this BOQ.
Material & labour for repairing remote / control kit / electronic card of window / split AC including taking down/out electronic card / control kit including refixing back at site after repair & testing etc complete all as specified and directed by Engineer-in-Charge.
S&F sub main wiring with two single core PVC insulated, unsheathed,FRLS stranded copper conductor cable 4 sqmm with 4 Sqmm PVC insulated, unsheathed,FRLS stranded copper conductor cable as earth wire drawn through in and incl PVC casing and caping ISI marked with all necessary accessories and earth wire connected to common earth dolly etc complete all as specified and directed by Engineer-in-Charge. (Make of cable:Finolex/RR Cable/Havells & Make for PVC casing & caping :AKG/PRESTOPLAST/PRECISION):- Note: 1.proper colour coding shall be adopted for wiring(For phase-Red,Yellow,Blue,For Earth-Green for Neutral-Black) Note: Two run of 4 sqmm cable i.e for one run for phase,one run for neutral with one run of 4 sqmm cable for earth and one run of PVC casing & caping Shall be measured as one unit.
An amount of Rs 74,006.00 shall be deducted rom BOQ on account of schedule of credit
Maruti Abhiyantriki
OM SAI ASSOCIATES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .