Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.9 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹27.3 L+₹84,940 (3.21%)Rejected-Finance 00 BEHIND CHARCH NAYAGOWAN LAKHERA BEHIND RAMA MANI DAIRY KATNI MADHYA PRADESH 483501 | KATNI | MADHYA PRADESH | 483501 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹27.6 L+₹1.1 L (4.28%)Rejected-Finance VILLAGE POST PATHOLI AGRA UTTAR PRADESH INDIA | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹27.6 L+₹1.2 L (4.48%)Rejected-Finance GRAM RAKSHAWARA THANA KARARI TAH MANJHANPUR KAUSHAMBI | KAUSHAMBI | UTTAR PRADESH | 212201 | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹28.1 L+₹1.7 L (6.38%)Rejected-Finance 86 NAROTTAM KUNJ MADHU NAGAR AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L5 | Rejected-Finance Being other than L1 |
Tender Value
₹28.3 L
EMD Value
₹56,600
Closing Date
2 Jun 2020, 6:00 pmClosed
GE EAST AGRA
62 TAJ ROAD GWALIOR HOUSE AGRA CANTT
REPAIR REPLACEMENT OF LT DISTRIBUTION NETWORK LT OH CONDUCTOR LT POLE INSULATOR GUARD WIRE STAY LT CABLE ETC IN MH STATION ROAD AREA AKBAR ROAD BARRACK ROAD COD LALKURTI 9 PARA 252 AD BTY ETC UNDER GE EAST AGRA
2020_MES_336521_2
9242/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGRA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE EAST AGRA
₹56,600
Yes
10 Jun 2020
27 May 2020
4 Jun 2020
27 May 2020
2 Jun 2020
28 May 2020
Amount
Note: Please refer schedule 'A' notes given on serial page No. 13 to 15 before quoting the tender.
Disconnecting/taking out of existing old unserviceable under ground cable any description, any size and in any position complete all as specified and directed.
Disconnecting/taking down of existing old unserviceable over head conductoe any description, any size and in any position complete all as specified and directed.
Disconnecting/taking out of existing old unserviceable over insulators any description, any size and in any position complete all as specified and directed.
Dismantling of MS cross arms , guard cradles etc. of any size of Channel or angle iron sections, clamps, nuts, bolts etc from existing HT/LT OH Lines and depositing to AGE E/M Yard for taking credit complete all as specified and directed.
Dismantling of GI earth wire/stay wire and depositing to AGE E/M yard for taking credit complete all as specified and directed.
Supply and fixing in repair of Volt meter 500 Volt cap 95 x 95 mm including dismentling complete all as specified and directed. Make: AE/L&T/Schneider
Excavation in trenches in soft/loose soil N. exc 1.5 Mtr wide and not exc. 1.5 Meter deep and getting out including forming bottom surface for laying of cable complete all as specified and directed.
Returning filling including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed.
Supplying and laying sand cushioning for cable protection in trenches /filling in ducts at Sub Stations complete all as specified and directed.
Supplying and laying bricks old size sub class ‘B’ laid flat across the cable with length of whole brick for protection of cable complete all as specified and directed.
Supply and laying connecting and testing XLPE insulated screened, PVC bedded, galvanized steel strip or wire armoured heavy duty electric cable with aluminium conductor 1100V grade cross sectional area 95 Sq mm 3.5 core complete all as specified and directed. Make Havells/ Gloaster/Polycab/Grandlay
All as per item No 13 above but 70 Sq mm 3.5core complete
All as per item No 13 above bu 50 Sq mm 4 core complete
All as per item No 13 above bu 35 Sq mm 4 core complete
All as per item No 13 above bu 25 Sq mm 4 core complete
M&L for drilling suitable dia horizontal bore holes including insertion/ laying of 80mm bore HDPE pipe of any description below/under existing road surfaces / floors at a level not less than 0.60 mtr etc with using mechanical / or manual devices as required at site including making good the disturbed surfaces to match with the existing after laying pipes complete all as specified and directed by Engineer-in-Charge. Note : (i) Cost of equipment tools and plant material (horizontal boring rig machine) required for boring shall be arranged by contractor at no extra cost to the Govt.
M & L for GI pipe light grade 50 mm dia with all fitting laid in bore holes/trenches/drain/culvert or fixed along with pole/wall including 02 Nos FI clamps of 25x3 mm including nut, bolts etc. complete all as directed. Make TATA/Jindal/ Prakash
Supply, installation, testing and commissioning of outdoor type LT Main Feeder Pillar (IP-55) CPRI approved powder coated with structural siemens grey RAL 7032 shall be factory fabricated cubicle panel board of size not less than 1800 x 1500 x 800 mm as per IS 8623 rated for short circuit rating of 50 KA, front and back operable and lockable by keys from both sides having louvers and air vent, gasket an totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing copper bus bar duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators (size not less than 50mmx50mm conical type at a maximum interval of 500mm) of not less than 1.5 times the rating of main incommer. The incommer and all outgoing shall have extention link of capacity 1.5 times the rating of individual feeder. If the size of incoming /outgoing cable is more than 120 sqmm, then the extention link shall not be less than 300 mm long, all links shall be insulated with colour coded heat shrinkable sleeves and supported arms DMC/epoxy insulators having provision for termination of incommer and outgoing cables. All control wires shall be not less than 2.5 sqmm multistranded FRLS copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs, the cubicle will have a bottom support of channel of suitable size, duly coated with zinc metal coating. A detachable pre drilled gland plate of thickness 3.15mm thick, cold zink metal coated shall be provided with at the bottom for entry for armoured cable with adequate size of gland. Manufacturer name plate with feeder details and danger plate shall be provided at suitable visible place. including neceessary PCC1:2:4 Type B2 work for grouting of feeder pillar box and Angle Iron 40mmx40mmx6mm thick frame work complete and comprises following
Supply, installation, testing and commissioning of outdoor type CPRI approved LT Main Feeder Pillar (IP-55) powder coated with structural siemens grey RAL 7032 shall be factory fabricated cubicle panel board as per IS 8623 rated for short circuit rating of 50 KA, front and back operable and lockable by keys from both sides having louvers and air vent, gasket an totally vermin proof made out of 3.15 mm thick CRCA sheet duly compartmentalized for incoming and outgoing copper bus bar duly insulated with colour coded heat shrinkable sleeves and mounted on DMC/epoxy insulators (size not less than 50mmx50mm conical type at a maximum interval of 500mm) of not less than 1.5 times the rating of main incommer. The incommer and all outgoing shall have extention link of capacity 1.5 times the rating of individual feeder. If the size of incoming /outgoing cable is more than 120 sqmm, then the extention link shall not be less than 300 mm long, all links shall be insulated with colour coded heat shrinkable sleeves and supported arms DMC/epoxy insulators having provision for termination of incommer and outgoing cables. All control wires shall be not less than 2.5 sqmm multistranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs, the cubicle will have a bottom support of channel. All control wires shall be not less than 2.5 sqmm multistranded copper conductor and properly bunched/tied, ferruled for proper identification and crimpled with adequate size of lugs, the cubicle will have a bottom support of channel of suitable size, duly coated with zinc metal coating. A detachable pre drilled gland plate of thickness 3.15mm thick, cold zink metal coated shall be provided with at the bottom for entry for armoured cable with adequate size of gland. Manufacturer name plate with feeder details and danger plate shall be provided at suitable visible place. including neceessary PCC1:2:4 Type B2 work for grouting of feeder pillar box and Angle Iron 40mmx40mmx6mm thick frame work complete and comprises following
M&L for earthing complete with galvanized earth plate electrode 600 x 600 x6mm thick burned directly in ground ( earth pit not less than 2.5 M below normal ground level ) with top edge of the plate not less than 1.75 M below normal ground level connected to and including galvanized steel Strip of size 32 x 6 mm as earth lead Earth plate to bldg test point including 40mm GI light grade pipe for earth protection from earth point to earth plate surrounded by 150mm thick alternate layers of charcoal dust mix all with 35% common salt, 20mm bore medium grade GI Pipe for watering PCC pit type 1:3:6 type C-1 using 20mm graded stone aggregate, with RCC 50mm thick cover in 1:2:4 TYPE B-1 reinforced with 8mm dia CTD bars @8mm e/c both way. GI check nut, funnel with wire mesh necessary excavation and earth work in any type of soil all as specified and shown in electrical plate No 3 of MES SSR Part I 2009 .Note : 1. Result of earhiing shall not be more than 1 ohms , all earthing work will be rework if result not achieved 2. Earth lead with GI Protection Pipe upto 7.5 meter shall be included in quoted rate of the item.
Supplying and fixing in repair MCCB, 630 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 100% ,50 KA withTharmal Magnetic release complete all as specified and directed by Engineer-in-Charge. Make Cat No 422023 of Legrand or equivalent to Schiider/ L & T
Supplying and fixing in repair MCCB, 400 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 100% , 36 KA withTharmal Magnetic release complete all as specified and directed by Engineer-in-Charge. Make Cat No 422007 of Legrand or equivalent to Schiider/ L & T
Supplying and fixing in repair MCCB, 250 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 100% , 25 KA withTharmal Magnetic release complete all as specified and directed by Engineer-in-Charge. Make Cat No 420219 of Legrand or equivalent to Schneider/ L & T
Supplying and fixing in repair MCCB, 200 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 100% , 25 KA withTharmal Magnetic release complete all as specified and directed by Engineer-in-Charge. Make Cat No 420218 of Legrand or equivalent to Schneider/ L & T
Supplying and fixing in repair MCCB, 100 Amps, 4 pole, 415 Volts, AC supply, having breaking capacity Icu =Ics = 100% , 25 KA withTharmal Magnetic release complete all as specified and directed by Engineer-in-Charge. Make Cat No 420055 of Legrand or equivalent to Schneider/ L & T
Servicing & Painting to panel any type/size with two coat of synthetic enalmeld paint including repair to existing unservicable items , connecting and disconnecting to electric connection including servicing and making proper connections, replancement of door gasket and door locks where necessary all as directed and specified Make of paint : Asian Paint(Apcolite), Shalimar(Superlac Hi Gloss), Nerolac Paint (Nerolac full Gloss).
Removing of old paint by removers scrubing from LT steel poles 9 meter long, cross arms clamps etc for painting and M &L for painting with one coat of superior quality aluminum paint on exposed surface of poles and street light bracket mounted on the poles,junction box etc and making black strip upto1.5 Mtr height from ground level and writing pole Nos etc. written on it with black synthetic enamel paint compete all as specified and directed Make of paint : Asian Paint(Apcolite), Shalimar(Superlac Hi Gloss), Nerolac Paint (Nerolac full Gloss).
Surface dressing in soft/loose soil not exceeding 15 cm deep and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr complete all as specified and directed.
trimming/cutting/chopping of tree branches all around LT/HT over conductor upto two meter and removing excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr complete all as specified and directed.
Releasing tension of existing OH line, of ACSR/copper conductor or GI earth wire of any size/type on existing OH line restretching properly and fixing on existing insulators on OH cross arms of poles including disconnection service connection street light fitting etc and reconnecting the same after restretching complete all as specified and directed (each conductor will be measured seperately)
M&L for MS cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and including one primer coat of red oxide and two coats of aluminium paint, complete all as specified.Make Tata/Jindal/ Sail
Supplying, fixing, stringing in replacement of aluminum conductor steel reinforced (ACSR) including binding wire for binding to aluminum conductor properly on insulators at least 50mm on existing/ new pole over head lines, jumpring, connection and jointing and testing complete all as specified and directed.
Supplying, fixing, stringing in replacement on pole of Galvanised steel wire 3.15 or 4mm dia as guard wire/ creddle complete all as specified and directed.
Material and labour PCC 1:3:6 type C-1 using 20 mm graded stone aggregate complete all as specified and diredcted for foundation of taxi light/flood light fittngs/feeder pillar box etc.complete all as specified and directed.
Supply and fix cable jointing kit suitable for 1100 Volts grade LT cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 25 to50 sqmm. Make : 3M / M-seal/ Denson/Reychem
Supply and fix cable jointing kit suitable for 1100 Volts grade LT cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3.5/4 core XLPE armoured aluminium conductor cable of size 70 to 95 sqmm. Make : 3M / M-seal/ Denson/Reychem
S & F cable PVC junction box having dimension not less than 200 x 160 x 98mm with metric knockouts for cable entry 16/25 sqmm three phase with neutral, Terminal for 6 sqmm cable and including MCB SP 6 Amp with suitable mounting arrangement including clamps, nut, bolts etc completed all as specified by engr-in-charge of make: Hensel cat part No K 9255 or equivalent as approved by GE
S&F MS Busbar Chamber factory made of of 200 amps 4 way including electric connection ,etc with and including FI clamp made out of 50 mmx 3 mm , nut and bolts complete all as specified and directed. Make havells Cat pt No IHBC020004 OR EQUIVALANT TO LEGRAND/SCHIEDER
3Krishna Enterprises
C P Singh and Co
Narendra & Co.
M/s J S & SONS
M/s SCHOLASTIC ENTERPRISES
Gupta Automobiles
virendera singh
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .