Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹64.5 LAccepted-AOC B 22 HQ ADG NEI GUWAHATI BABULAR BAZAAR TINSUKIA 786125 ASSAM | TINSUKIA | ASSAM | 786125 | 1 | Accepted-AOC ACCEPTED | |
| 2 | 2₹66.0 L+₹1.5 L (2.26%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | 2 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 3 | 3₹71.6 L+₹7.1 L (11.0%)Rejected-Finance A T ROAD CHABUA DIBRUGARH ASSAM 786184 | DIBRUGARH | ASSAM | 786184 | 3 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 4 | 4₹75.9 L+₹11.4 L (17.6%)Rejected-Finance | 4 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER | |
| 5 | 5₹79.2 L+₹14.7 L (22.7%)Rejected-Finance 33 CHANDASI HOUSE LANE NO 11 S K PURAM ARYA SAMAJ MANDIR ROAD RPS MORE BAILEY ROAD DANAPUR PATNA BIHAR 801503 | PATNA | PATNA | BIHAR | 801503 | 5 | Rejected-Finance REJECTED NOT BEING THE LOWEST TENDERER |
Tender Value
₹79.9 L
EMD Value
₹1.4 L
Closing Date
26 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) JORHAT
HQ CWE (AF) JORHAT, ROWRIAH, JORHAT, ASSAM-785005
84137/E8 PROVN OF PRE PAID SMART METERS IN MD ACCN AT AF STN DINJAN PH-I UNDER GE AF MOHANBARI
2025_MES_702357_1
84137/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE AF MOHANBARI
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
GE AF MOHANBARI
₹1.4 L
Yes
9 Jun 2025
22 Mar 2025
28 Apr 2025
22 Mar 2025
26 Apr 2025
14 Apr 2025
Amount
INTERNAL ELECTRIFICATIONS
Taking down Old existing Meter (both Serviceable and Unserviceable) and Depositing to MES Store for further Re-use/ Disposal action as deemed fit, complete all as specified and as directed.
Disconnecting & Taking down MCB of any description, complete all as specified and as directed.
Disconnecting & Taking down MCB Distribution Board of any description including Make Good Disturbed Surfaces of Walls/Ceilings, etc. with Cement Mortar 1:3 and Providing Surface Treatment (White/Colour Washing/ Distempering, etc.) wherever required to match the Existing Finishes, complete all as specified and as directed.
M&L Point Wiring with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable with 4.0 Sqmm (nominal area) 1100 Volt grade PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Wire, drawn in and including PVC Conduit (ISI Marked) of suitable Size (20/25mm Dia) along with all Fitting/Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. including suitable Size PVC Board with 3.0mm thick Hylam Sheet Cover for mounting Switches, Sockets, etc., Earth Continuity Wire connected to Common Earth dolly for ONE SWITCH SOCKET OUTLET, 16 AMP, 3/5 PIN on INDEPENDENT BOARD, complete all as specified and as directed.
M&L Sub-main Wiring with 2-Runs of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable and 1-Run of 4.0 Sqmm (nominal area) 1100 Volt PVC insulated Unsheathed FRLSH Multi-stranded Single Core Copper Conductor Cable (Green Colour) as Earth Continuity Conductor drawn through and including PVC Conduit (ISI Marked) of suitable Size (approx 20/25mm Width) along with all Fitting/ Fixtures as Tee, Bend, Elbow, Socket, Saddles, etc. (White/ Ivory/ Off White in Colour) and Make Good Disturbed Surfaces of Walls/ Roofs/ Floors, etc. so as to match with the Existing Finishes, complete all as specified and as directed. NOTE :- (a) Cost of 3-Runs Cable & 1-Run PVC Conduit will deem to be include in the Quoted Unit Rate and the same also Measured as ONE UNIT. (b) Sub-main Wiring will be measured PVC Conduit only. Wire for looping (as ordered/required), etc. will deem to be included in the Quoted Unit Rate.
S&F Switch Socket Combination 15/16 Amp, 3 Pin, Piano type, Multi-purpose, 230/240 Volt AC and Connecting up, complete all as specified and as directed.
S&F MCB 6 Amp to 32 Amp, Single Pole (SP), 'C' Curve, 50 Hz, 10 kA, 240 Volt and Connecting up, complete all as specified and as directed.
S&F MCB 32 Amp to 40 Amp, Single Pole & Neutral (SPN), 'C' Curve, 50 Hz, 10 kA, 240 Volt and Connecting up, complete all as specified and as directed.
S&F Factory made Sheet Metal Enclosure Distribution Board 8-way, SPN, Horizontal type, Double Door, 240 Volt, IP-43 Protected with Steel Phosphatised Powder Painted having Neutral Bars & Earth Bar, fixed Flush with Wall Inside the Niches or Out-side on Wall Surface suitable for Mounting Isolators & MCB's etc. and Connecting up, complete all as specified and as directed.
S&F Factory made Sheet Metal Enclosure, Concealed Single Pole & Neutral with Socket Plug Top, having 2-Pin Earth Plug & Socket, IP-43 Protected with Steel Phosphatised Powder Painted, Fixed with MCB 20 Amp (01 No.) Double Pole, 240 Volt, Flush with Wall Inside the Niches or Out-side on Wall Surface suitable for Mounting MCB's, etc. and Connecting up, complete all as specified and as directed.
EXTERNAL ELECTRIFICATIONS
Disconnecting & Taking down/ out Unserviceable LT Cable, UG Cable of Size upto 50 Sqmm, 2.0/3½/4.0 Core and any description from Poles, Trenches, Floors, Walls, GI Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Disconnecting & Taking down/ out Unserviceable LT Cable, UG Cable of Size 240 Sqmm to 400 Sqmm, 3½ Core and any description from Poles, Trenches, Floors, Walls, GI Pipes, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
Disconnecting & Taking down/ out Unserviceable LT Feeder Pillar Box/ LT Panel including Connected Items of any description, complete all as specified and as directed.
Disconnecting & Taking down/ out Unserviceable Earthing of any description, complete all as specified and as directed.
Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable Lines, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Lines, etc. with Surplus Soil in Soft/Loose Soil, complete all as specified and as directed.
Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
M&L Horizontal Boring of Holes under Road, Pavement, Hardstanding by Trenchless Technology Using Ultra Sounding Technique and necessary Machine/ T&P including HDPE Pipe of 150/160mm bore (dia) suitable for 0.4 mpa Working Pressure, complete all as specified and as directed. NOTE : Cost of HDPE Pipe and Hire Charges of necessary T&P will deem to be included in the Quoted Unit Rate.
M&L XLPE insulated, Armoured, Heavy duty Electric Cable with Aluminium Stranded Conductor, 1100 Volts grade, Cross-sectional Area 10 Sqmm, 2.0 Core including Providing Electrical Connection with Cable Glands, Lugs, etc., Laid in Trenches/ Ducts or Passing through Pipe or Fixing to Poles, Walls, etc. with suitable Size Mild Steel Flat Iron Clamps, Bolts, Nuts & Washers, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.
M&L XLPE insulated, Armoured, Heavy duty Electric Cable with Aluminium Stranded Conductor, 1100 Volts grade, Cross-sectional Area 50 Sqmm, Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe including Providing Electrical Connection with suitable Size Cable Glands, Lugs, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.
M&L XLPE insulated, Armoured, Heavy duty Electric Cable with Aluminium Stranded Conductor, 1100 Volts grade, Cross-sectional Area 240 Sqmm, Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe including Providing Electrical Connection with suitable Size Cable Glands, Lugs, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.
M&L XLPE insulated, Armoured, Heavy duty Electric Cable with Aluminium Stranded Conductor, 1100 Volts grade, Cross-sectional Area 400 Sqmm, Sqmm, 3½ Core, laid in Trenches/ Ducts or Passing through Pipe including Providing Electrical Connection with suitable Size Cable Glands, Lugs, etc., complete all as specified and as directed. NOTE : Necessary Earth Works, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under appropriate Items.
Supply, Laying & Testing XLPE insulated, Screened, PVC Bedded, Galvanised Steel Strip or Wire Armoured, Electric Power Cables (Heavy duty) with Aluminium Stranded Conductor, 11000 Volts Grade (Earthed), Cross sectional Area 95 Sqmm, 3 Core, laid in Trenches/ Ducts or Passing through Pipe including Providing Electrical Connection with suitable Size Cable Glands, Lugs, etc., complete all as specified and as directed. NOTE : Necessary Earthworks, Sand Cushioning, Bricks, GI Pipe, etc. will be Measured and Paid separately under relevant Items.
M&L Cable Jointing Kit for 11 KV (Earthed) Grade Cable, Indoor Termination, Heat Shrink type complete with Jointing Materials and Accessories suitable for XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 95 Sqmm, 3 Core, Providing Connection and Testing, complete all as specified and as directed.
M&L Cable Jointing Kit for 11 KV (Earthed) Grade Cable, Outdoor Termination, Heat Shrink type complete with Jointing Materials and Accessories suitable for XLPE Armoured Aluminium Conductor Cable, Cross-sectional Area 95 Sqmm, 3 Core, Providing Connection and Testing, complete all as specified and as directed.
M&L Sand Cushioning (Dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 230mm Spread thickness (80mm in Depth before Laying the Cable and 150mm in Depth after Laying the Cable) and Consolidated (Punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
Supply & Laying Sub-class ‘B’ Bricks of Size 230x115x75mm, Kiln burnt, for Covering to UG Cable as Protection, laid Flat, Transversally Width Equal to the Length of the Cable, complete all as specified and as directed.
Supply & Laying Un-reinforced Pre-cast Concrete (Grade not Lower than M-20) Cable Cover of Size 450x180x40mm, Flat, Class HVP, Type 2 with Peak, complete all as specified and as directed.
S&F Galvanised Steel Tubing 100mm bore (dia), Light grade, Conforming to IS-1239 with all Fittings for Protection of UG Cable, laid in Trenches, etc., complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid separately under appropriate Items.
S&F PCC Cable Route Indicator in PCC 1:2:4 (20mm graded stone aggregates) Block of Size 300x300x300mm and Embossing HT/ LT Indicator made out with Mild Steel/ Cast Iron Round Shaped Sheet, welded with Mild Steel Flat Iron 25x5.0mm of 200mm long, Painted with Two Coats of Synthetic Enamel Paint over a coat of Red Oxide Zinc Chrome Primer to Exposed Steel or Iron Surfaces and Grouting Vertically to Natural Ground to a Depth of 300mm (minimum) including necessary Earth Work, complete all as specified and as directed. NOTE : Cost of Earth Work, Formwork, Painting Work, etc. will deem to be included in the Quoted Unit Rate.
Supply, Installation, Commissioning & Testing Factory made (CPRI Tested/ Certified Manufacturer) LT Outdoor Feeder Pillar Box of Size 1200x1000x600mm (minimum), made out of 3.15mm (Outer) and 2.00mm (Inner) thick CRCA Steel Sheet with Angle Iron Frame Work and 4 No. Legs of ISA 50x50x5.0mm, Front and Rear Openings, AC 415 Volt, 50 Hz 3 Phase, 4-Wire, Totally Enclosed Self Supporting Structure/ Cubicle, Fully Compartmentalized type, Weather Proof, Dust and Vermin Proof, IP-54 Protected, Double Door type, having Bottom Cable Entry with suitable Cable Glands, Angle Iron Legs grouted in PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangements for Bus-bars, Ammeter, Voltmeter, Changeover Switch, MCCBs with Slope Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangement including Louvers at Sides, Feeder Pillar Box duly Powder coated and for Accommodating and including following Accessories:- BUS-BARS :- (a) Aluminium Bus-bar 200 Amp supported on Non-hygroscopic Fibers - 04 No. and Brass Screws for mounting
Supply, Installation, Commissioning & Testing Factory made (CPRI Tested/ Certified Manufacturer) LT Outdoor Feeder Pillar Box of Size 1500x1500x800mm (minimum), made out of 3.15mm (Outer) and 2.00mm (Inner) thick CRCA Steel Sheet with Angle Iron Frame Work and 4 No. Legs of ISA 50x50x5.0mm, Front and Rear Openings, AC 415 Volt, 50 Hz 3 Phase, 4-Wire, Totally Enclosed Self Supporting Structure/ Cubicle, Fully Compartmentalized type, Weather Proof, Dust and Vermin Proof, IP-54 Protected, Double Door type, having Bottom Cable Entry with suitable Cable Glands, Angle Iron Legs grouted in PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangements for Bus-bars, Ammeter, Voltmeter, Changeover Switch, MCCBs with Slope Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangement including Louvers at Sides, Feeder Pillar Box duly Powder coated and for Accommodating and including following Accessories:- BUS-BARS :- (a) Aluminium Bus-bar 400 Amp supported on Non-hygroscopic Fibers - 04 No. and Brass Screws for mounting
Supply, Installation, Commissioning & Testing Factory made (CPRI Tested/ Certified Manufacturer) LT Outdoor Feeder Pillar Box of Size 1500x1500x800mm (minimum), made out of 3.15mm (Outer) and 2.00mm (Inner) thick CRCA Steel Sheet with Angle Iron Frame Work and 4 No. Legs of ISA 50x50x5.0mm, Front and Rear Openings, AC 415 Volt, 50 Hz 3 Phase, 4-Wire, Totally Enclosed Self Supporting Structure/ Cubicle, Fully Compartmentalized type, Weather Proof, Dust and Vermin Proof, IP-54 Protected, Double Door type, having Bottom Cable Entry with suitable Cable Glands, Angle Iron Legs grouted in PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangements for Bus-bars, Ammeter, Voltmeter, Changeover Switch, MCCBs with Slope Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangement including Louvers at Sides, Feeder Pillar Box duly Powder coated and for Accommodating and including following Accessories:- BUS-BARS :- (a) Aluminium Bus-bar 500 Amp supported on Non-hygroscopic Fibers - 04 No. and Brass Screws for mounting
Supply, Installation, Commissioning & Testing Factory made (CPRI Tested/ Certified Manufacturer) LT Outdoor Feeder Pillar Box of Size 1500x1500x800mm (minimum), made out of 3.15mm (Outer) and 2.00mm (Inner) thick CRCA Steel Sheet with Angle Iron Frame Work and 4 No. Legs of ISA 50x50x5.0mm, Front and Rear Openings, AC 415 Volt, 50 Hz 3 Phase, 4-Wire, Totally Enclosed Self Supporting Structure/ Cubicle, Fully Compartmentalized type, Weather Proof, Dust and Vermin Proof, IP-54 Protected, Double Door type, having Bottom Cable Entry with suitable Cable Glands, Angle Iron Legs grouted in PCC 1:2:4 (20mm graded stone aggregates) Foundation Block with suitable mounting Arrangements for Bus-bars, Ammeter, Voltmeter, Changeover Switch, MCCBs with Slope Canopy at Top, Double Hinged Doors at Front with suitable Locking Arrangement including Louvers at Sides, Feeder Pillar Box duly Powder coated and for Accommodating and including following Accessories:- BUS-BARS :- (a) Aluminium Bus-bar 750 Amp supported on Non-hygroscopic Fibers and - 04 No. Brass Screws for mounting
Supply, Installation, Testing & Commissioning Outdoor type Transformer Step Down, Copper wounded having Primary Side for HT Three Phase 11 KV & Secondary for 3 Phase, 433 Volts, 4 Wire, 50 Hz of Capacity 250 KVA as per IS-1180 Part-I or as per latest IS Amendment Level-II with and including the following Specifications :- (a) No Load Voltage Ratio - 11KV/ 0.433 KV (b) Nos. of Phase - Three (c) Type of Cooling - ONAN (d) Frequency - 50 Hz (e) Vector Group - DYN 11 (f) Two Earthing Terminals for Body Earthing and Two Additional for Neutral (g) Oil Level Gauge indicating Oil Level with Minimum & Maximum Indication (h) Lifting Lugs Rollers and MS Terminal Box on both HT and LT Side (j) Rating & Terminal Marking Plates (k) Dehydrating Breathing Device which would not permit Ingress of Moisture, Rain Water and Insects
(l) Drain Cum Sampling Valve preferably Steel with Plug (m) Off Load Tap Changer (+5.0% to -10% in Steps of 2.5% with 7 Position) (n) Oil Filling Hole with Cover (Transformer with Conservator) (o) Connection - Delta / Star (p) Temperature Rise in Oil - 40 °C (q) Temperature Rise in Windings - 45 °C (r) Material Winding - Copper Wound (s) High Voltage/ Low Voltage with Cable Termination Box (t) Service - Outdoor type (u) Neutral - Internally connected with Earthing Lead and Bush (v) First Filling of New Dehydrated Transformer Oil upto recommended Level. NOTE :- (a) Cost of Plinth for Transformer as recommended by Manufacturer OEM with Chain Link Fencing of 75x75mm Mesh with 4.0mm Dia Wire (surrounding 1.0 Metre apart from Plinth) and Gate of suitable Size or as ordered will deem to be included in the Quoted Unit Rate. (b) Transformer shall be Despatched only after Inspection Clearance by the Inspecting Officer appointed byAceepting Officer.
M&L Writing Letters or Figures (Block, Roman, Italic or Indian) on Cable Route Indicator & Panels, etc. not exc. 150mm High with Synthetic Enamel Paint (as per Colour Scheme), complete all as specified and as directed.
M&L Earthing Complete with Galvanised Earth Plate Electrode 600x600x6.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Galvanised Earth Strip of Size 32x6.0mm by means of Bolts, Nuts, Check nuts and Washers of GI or Steel and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) ‘Light’ grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC 1:2:4 (20mm graded stone aggregates) Cover Slab of Size 450x450x50mm, Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) ‘Medium’ grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I, Testing on Completion, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
M&L Earthing Complete with Copper Earth Plate Electrode 600x600x3.0mm thick buried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, Connected with and including Copper Earth Strip of Size 20x3.0mm by means of Copper/ Brass Bolts, Nuts, Check nuts and Washers and connected Earthing Testing Point/Bus-bar with GI 40mm bore (dia) ‘Light’ grade Protection Pipe, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregates) and Pre-cast RCC 1:2:4 (20mm graded stone aggregates) Cover Slab of Size 450x450x50mm, Reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) ‘Medium’ grade including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I, Testing on Completion, complete all as per specified and as directed. NOTE : All Joints should be joined by Exothermic Welding or Brazing.
DEDUCTION AGAINST SCHEDULE OF CREDIT
Bidder(s) is/ are required to Quote the EQUAL AMOUNT (as per SCHEDULE OF CREDIT at SERIAL PAGE No. 22 of TENDER DOCUMENTS) under Column 5 i.e. 'UNIT RATE' (M) against ROW No. 59 .
M/S R G Construction (BID ID -3282054)
kabitaconstruction (BID ID -3284541)
M/s Dhruv Enterprises (BID ID -3287340)
Roy and Sons Infrastructures (BID ID -3284906)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .