| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.1 LAccepted-AOC GROUND FLOOR HEALTH CENTRAL 1 NO RAJA BUNGLOW PO DHORI DIST BOKARO PIN 825102 JHARKHAND | DHORI | BOKARO | JHARKHAND | 825102 | L1 | Accepted-AOC Awarded | |
| 2 | Rejected-Technical AT SOUTARDIH DHORI BASTI PO BERMO DIST BOKARO | BOKARO | JHARKHAND | 825102 | - | Rejected-Technical NOT EVALUATED | |
| 3 | Rejected-Technical 268 KARGALI BAZAR BERMO BOKARO 829104 JHARKHAND | BOKARO | JHARKHAND | 829104 | - | Rejected-Technical NOT EVALUTED |
Tender Value
Refer Docs
EMD Value
₹2,500
Closing Date
24 Jan 2023, 10:00 amClosed
P E EnM, Kargali OCP
Office of P E EnM, Kargali OCP
Repairing of wiring of 8 nos residential quarter occupied by P imambel, jogindra ram, ramesh, gopal ram, revati devi, somnath chatterjee, suresh giri, Mahesh ram of kargali OCP
2023_CCL_267993_8
CCL/BnK/KARGALI OCP/EnM/22-23/9
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
kargali OCP
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
19 Jun 2023
17 Jan 2023
25 Jan 2023
18 Jan 2023
24 Jan 2023
18 Jan 2023
18 Jan 2023 - 20 Jan 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group A
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 2 + 4 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral
Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required. 32 Amp TP&N
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.2 x 4 sq. mm
Total impact of GST for the purpose of CTC
M/s Kiran Electrical works
BIHAR ELECTRICAL WORKS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .