Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC 139 3 A AMAR CHAKRABORTY ROAD PO KHAGRA DIST MURSHIDABAD PIN 742103 | MURSHIDABAD | WEST BENGAL | 742103 | L1 | Accepted-AOC L1 Bidder | |
| 2 | L2₹28.8 L+₹4.7 L (19.4%)Rejected-Finance MATHURAPUR SONARPUR KOLKATA 700150 | KOLKATA | 24 PARAGANAS SOUTH | WEST BENGAL | 700150 | L2 | Rejected-Finance quoting higher rate | |
| 3 | L3₹29.0 L+₹4.9 L (20.5%)Rejected-Finance 2 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L3 | Rejected-Finance quoting higher rate |
| Sl No | Description | Qty | Unit | TARAKESHWAR ELECTRO ENTERPRISE L2 | MAHESWAR ELECTRICAL INDUSTRIES L3 | SUBHAM ELECTRICAL L1 |
|---|---|---|---|---|---|---|
| 1.00 | Disconnection & dismantling existing old/defective Electrical installation, Switch-board, wiring, Electrical fitting/fixtures etc with owns tools & takles without distrubing the day to day Govt works as well as providing uninterrupted power supply by temporary arrangement incl. clearing/removing from the site & handing over to the authority and mending good damages as per GS and as per direction of E.I.C | 1 | Item | 4,999 ₹4,999 | 500 ₹500 Lowest | 3,000 ₹3,000 |
| 2.00 | Supplying and fixing 415V, 250A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make:-Siemens/ L &T) | 1 | No. | 22,500 ₹22,500 | 14,038 ₹14,038 | 11,570 ₹11,570 Lowest |
| 3.00 | Supplying and fixing 415V, 250 A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per diection of EIC(Make:-L&T). (To be fixed on wall beside the existing panel as per instruction of authority for future provision) | 1 | No | 23,500 ₹23,500 | 13,287 ₹13,287 Lowest | 14,198 ₹14,198 |
| 4.00 | Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40 x 6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel. | 1 | Nos. | 1,97,500 ₹1,97,500 | 2,09,500 ₹2,09,500 | 1,77,000 ₹1,77,000 Lowest |
| 4.01Construction Details : | ||||||
| 4.02All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side. | ||||||
| 4.03Incomming Switch : | ||||||
| 4.04i) 415V, 250A, 36kA FP MCCB With Thermal - Magnetic Release (Make- L&T, Cat No.- CM92109OOP1OG or equivalent model of SIEMENS/Legrand) with extended spreaded terminals (L&T- Kit CM92007OOOO- 8 Pcs) and Rotary Handle (L&T, Cat No.-- CM99829OOOO or equivalent model of SIEMENS / Legrand) -- 1 No. | ||||||
| 4.05Bus bar Section :- | ||||||
| 4.06415V, 400 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x25 mm x 10 mm + 1x25 mm x 10 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set. | ||||||
Tender Value
Refer Docs
EMD Value
₹60,221
Closing Date
28 Jan 2026, 1:00 pmClosed
The Executive Engineer PWD,ECD
New office Complex Building(5th Floor) Bhabani Bhawan Alipore, Kolkata 700027
Repair and Renovation to Electrical Installation works of Administrative Building with street lighting system and arrangement of necessary poles from main gate to Hostel building in the campus of ITI Tollygunge
2026_WBPWD_983488_1
WBPWD/EE-ECD/e-NIQ-46/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Tollygunge
please refer tender documents
5 documents required · 5 mandatory
₹60,221
O/O The Executive Engineer PWD ECD
26 May 2026
5 Jan 2026
30 Jan 2026
5 Jan 2026
28 Jan 2026
15 Jan 2026
5 Jan 2026 - 13 Jan 2026
13 Jan 2026
Disconnection & dismantling existing old/defective Electrical installation, Switch-board, wiring, Electrical fitting/fixtures etc with owns tools & takles without distrubing the day to day Govt works as well as providing uninterrupted power supply by temporary arrangement incl. clearing/removing from the site & handing over to the authority and mending good damages as per GS and as per direction of E.I.C
Supplying and fixing 415V, 250A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating. (Make:-Siemens/ L &T)
Supplying and fixing 415V, 250 A TPN on load front operated Changeover switch with Sheet Steel enclosure on angle iron frame on wall with nuts bolts etc as per diection of EIC(Make:-L&T). (To be fixed on wall beside the existing panel as per instruction of authority for future provision)
Supply and installation of L.T. cubical type fully compartmentalized distribution panel board, having rigid and self supporting structure fabricated with 14 SWG CRCA sheet with M.S. angle iron frame (main frame with 50 x 50 x 6 mm angle and each vertical compartment with 40 x 40 x 6 mm MS angle iron). The base of panel should be made with 75mm x 40mm x 4.4 mm M.S. channel. [Manufacturer/Fabricator having Test Certificates from CPRI]. An Auto Cad Drawing of the panel has to approved by EIC before making of panel.
Construction Details :
All incoming & outgoing switches are to be housed in respective compartments hinged and gasket doors at the front. All doors should have panel locking arrangement in such a fashion that it can not be on unless the feeder remains in off position. The rear panel should gasketed wire net guard for ventilation arrangement will be made of easy accessibility to each compartment by providing rear panel doors with locking system . The panel is to be properly gasketed to prevent the dust & vermin. All vertical bus bar chambers is to properly arrange and all electrical equipments are to be fixed by nuts and bolts on suitable Hylam board / porcelain insulators of adequate size and dimension. The outgoing feeder connection from respective switches are to be made at rear side of panel by means of busbar, copper multi core cables, to be terminated on bolted type terminals for cable connection or on bush insulators for bus bar connection. Each compartment will be providing with DMC/FRP board at back side.
Incomming Switch :
i) 415V, 250A, 36kA FP MCCB With Thermal - Magnetic Release (Make- L&T, Cat No.- CM92109OOP1OG or equivalent model of SIEMENS/Legrand) with extended spreaded terminals (L&T- Kit CM92007OOOO- 8 Pcs) and Rotary Handle (L&T, Cat No.-- CM99829OOOO or equivalent model of SIEMENS / Legrand) -- 1 No.
Bus bar Section :-
415V, 400 Amp capacity 99.9% – 99.5% electrolytic tinned 4 bar copper bus bar [size of flat 3x25 mm x 10 mm + 1x25 mm x 10 mm] mounted on non-hygroscopic porcelain insulator / hylam sheet having sufficient di-electric strength duly wrapped with colour PVC tapes (Red, yellow, blue & black) for phases & neutral identification - 1 set.
The busbar is to be rigidly supported on suitable non-hygroscopic insulating materials of robust ration to with stand electromechanical stress in the event of earth fault. All connection to bus to made by suitable nuts & bolts. The busbar is too wrapped with coloured PVC (Red. Yellow, Blue & Black) for colour identifications.
Outgoing Switches :-
a) 415V, 125A, 36kA FP MCCB With Thermal - Magnetic Release (Make- L&T, Cat No.-CM92108OOL1OG or equivalent model of SIEMENS/Legrand) with extended spreaded terminals (L&T- Kit CM92007OOOO- 8 Pcs) and Rotary Handle (L&T, Cat No.-- CM99829OOOO or equivalent model of SIEMENS / Legrand) -- 5 Nos.
b) 415V, 63A, 36kA FP MCCB With Thermal - Magnetic Release (Make- L&T, Cat No.-CM97919OOJ2OG or equivalent model of SIEMENS/Legrand) with Rotary Handle (L&T, Cat No.-- CM97895OOOO or equivalent model of SIEMENS / Legrand) -- 1 No.
Metering Panel :-
a) 3Ph LED single function Ammeter (Cl 0.5) ( Make L& T, Model- CAT No.-WL131020OOOO or equivalent)- for ammeter --- 1no.
b)3Ph LED single function Voltmeter( Cl 0.5) ( Make L& T, Model no..WL132020OOOO or equivalent) for voltmeter-- 1 no.
c) S& F basic multifunction meter MFM 4400 LED meter Cl 0.5 with RS485 ( Make L& T CAT No.WL440021OOOO or equivalent) - 1 no
d) Indicating LED Lamp with colour glasses showing (Red/Yellow/Blue/Amber) (Make- Siemens, Cat No.- 3SB5285-6HC03, 3SB5285-6HD03, 3SB5285-6HF03 or equivalent) - 21 Set.
d) 250/5 Amp ratio C.T (Kappa or equivalent) --- 3 nos.
e) Supplying & Fixing 6 Amp SP MCB---- 3 nos.
f) E.I. Danger Board of suitable size ------- 1 No.
Interconnection :-
All interconnection between incoming main to Busbar and busbar to all outgoing mains are to be made with suitable size of electrolytic tinned copper bars or equivalent flexible pvc insulated multistranded single core Cu cable as approved by E.I.C and also for metering arrangements are to be made by suitable size of Copper wire with proper socketing of the end of each wire leads as approved/direction of E.I.C
Earthing :-
A separate continuous aluminum earth busbar of size 40mm x 5 mm shall run across the full length of the panel board and brought outside the panel. All electrical equipment are to be properly earthed with suitable size G.I. wire.
The complete panel board is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating.
Installation :-
The complete panel board is to be installed on suitable brick padestal as directed by the E.I.C.
All incoming/outgoing switches is to be properly lebeled on Acrylic sheet as per direction of EIC.
Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
a) 4 way Enclosure [Make: Legrand Enclosure (607913) or equivalent model of Siemens/L&T as approved by E.I.C]
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment
6 Way Make - Legrand, Enclosure (607716 ) or equivalent model of Siemens/L&T as approved by E.I.C.
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.
2+14 Way [Legrand/Siemens/L&T as approved by E.I.C.
Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kA with fixed thermal and fixed magnetic / adjustable thermal and fixed magnetic setting in existing DBs / enclosure and necessary connection. (Make: Legrand /Siemens/L&T as approved by E.I.C)
125 A FP MCCB
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.(Make: Legrand /Siemens/L&T as approved by E.I.C)
a) 63 Amps TP MCB
b) 6-32 Amps SP MCB
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. (Make: Legrand /Siemens/L&T as approved by E.I.C)
(a) 63Amp FP Isolator
(b) 40 Amp DP Isolator
Supply & Delivery of XLPE Insulated & Sheathed Armoured Aluminium Conductor cable for Working Voltage up to 1100 Volts of following sizes [Make: Gloster/Polycab/RR Kabel/Mescab/Havells as approved by E.I.C]
(i) 4 Core 16 Sqmm
(ii) 4 Core 35 Sqmm
Laying of 4 core 35sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting a s per direction of EIC
Laying of 4 core 16 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting a s per direction of EIC
Supplying and fixing compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS.
i) 4 Core 35 Sq. mm
ii) 4 Core 16 Sq. mm
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/RR Kabel/Havells/Polycab/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) fixed on Modular GI switch board with top cover plate and 2 no. suitable size “Ph & N” copper bar & earthing attachment fixed on wall incl. mending good damages to original finish.
a) (Average run 8 mtr)
b) (Average run 10 mtr)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/RR Kabel/Havells/Polycab/Gloster) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 6A 3 pin Modular type plug socket & switch (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on 4 Module GI switch board with 3/4 Module top cover plate on wall incl. necy. connection making earthing attachment, painting and mending good damages to building works
a) On Board
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
a) 20 mm size
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire(Finolex/RR Kabel/Havells/Polycab/Gloster) of the following sizes in the 19mm/25mm prelaid polythene pipe/PVC rigid conduit as per GS.
a) 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
b) 2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) as ECC
c) 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) as ECC (
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
a) 4 sqmm
b) 6 sqmm
Supply & Delivery of double LED tube light fitting complete with all accessories [Philips make Cat No. TMC 502 2xT-LED 22W or equivalent model of Wipro] incl. supply of 2 nos. MAS LED tube 1200mm 18W 865 T8I -2100lm (Make -Philips/ Wipro) complete with all accessories.
Supply & delivery of Single LED tube light fitting complete with all accessories [Philips make Cat No. TMC 502 1xT-LED 22W or equivalent model of Wipro] incl. supply of 1 nos. MAS LED tube1200mm 18W 865 T8I -2100lm (Make -Philips/ Wipro eq.) complete with all accessories.
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.
Supply & Fixing 240 V, 25 A, Modular type starter (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket ((Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C), without plug top and switch with 2 Module GI Modular type switch board with top cover plate flushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing computer board[Modular type] comprising of 240 V 3 nos. 6 A 1 no 20A 3 pin Modular type plug socket with separate 3 nos. 6 A & 1 no. 20A Modular type switch, indicator & 20A Modular type SPMCB 25A on 2 row 12Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switchboard and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C)
Supply & Delivery of 240V, 18" (1420 rpm) Full metal body & blade wall bracket fan (Make : EPC /Crompton 450mm ACVORTEX18WM/STORM II PLUS as approved by E.I.C)
Fixing only wall fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length
Supply & delivery of 230 V 1200 mm sweep Ceiling fan complete with all accessories. The capacitor of fan must be P2 type burst proof & must have safety wire directly linked from fan hook to stator of fan. ( Make - Orient New Breeze/ Crompton Aura 1200 or equivalent of Havells as approved by E.I.C)
Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Legrand: Myrius/Arterior /ROMA Urban as approved by E.I.C) on existing Modular GI switch board with top cover plate incl. making necy. connections etc
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
Supply and delivery of 30 W Indoor type 2'x2' Full glow recessed mounting LED light fitting complete with all accessories (Make-Philips, RC380B LED36S-6500 G6 L60W60 PSUOD S1/ Wipro CRCO1ORO3OHP57G3 as approved by E.I.C)
Fixing only ceiling LED fittings on wall /ceiling by screws etc.
Compound Lighting:- Supply & delivery or 7.0 Mtr Hot Dip Galvanized (86-65 micron. dry film thickness) Octagonal Pole, as per BSEN l0025; ASTM A572; IS 5986: IS 475 9/2629, ASTM AI23 and BSEN lS l461 standard. The pole should be 7.0 Mtr long bottom dia-130 mm, top dia-70mm thickness-4mm, continuously tapered and shall have octagonal cross section with pole cap at top, necessary cleat attachment/hanger for arm brackets. Base-plate having dimension 200x200x12 mm and 4 nos 'J' Type foundation bolt with DOUBLE nut and plate washer, bolt dia 20 mm , PCD- 200 mm ,bolt length- 600 mm, Projected bolt length - 100 mm( these dimention are subjected to tolerance as per IS-2102 except for bending radius). The pole will consist of a built-in loop-box having one 32A 4-terminal stud type connector, one 250V 5A kit-kat fuse unit, one NL on porcelain insulator, it permits clear access to equipment like cables, socket, etc . The door opening shall be complete with a closefitting, vandal resistance, weatherproof door ( to IP-55 of IS:2l47), providing with a heavy duty double internal lock with special paddle key. The door opening shall be carefully designed and reinforced with welded steel section.
The Pole should be supplied with adequate templates for the purpose of construction of base foundation.The pole should have earthing terminals 02(two) nos at a height of 600 mm from the base plate for connection of earth continuity wires/ conductors (Make:- Transrail/Subham/Bajaj] (Drawing & design from pole manufacturer should be approved by EIC).
Erection of upto 7 Mtr octagonal Gl (Hot Dip Galvanised in single dip) pole including carriage of upto 1.6 Km from the store to work-site with foundation of M20 grade concrete for 7.0 Mtr Gl Octagonal Pole with all the materials like sand, cement, stone chips, reinforcement steel, binding wire etc as relavent IS Code. soil bearing capacity at site as 7 T/sqmtr., by PCC Base foundation having (L-1000mm x W- 1000mm x H-100mm) & RCC foundation having dimention (L-500mm x W- 500mm x H-1400mm) including neatly cemented finish (3mm thick) above ground level. There should be multiple alkathene pipes upto 1.2 mtrs of 50 mm dia of adequate length for distribution of incoming & outgoing cables for street light wiring as directed by EIC in the CC foundation of octagonal poles
SITC of single arm dip galvanaized steel overhang bracket (swan Neck type) at the top of the pole having 1 mtr length complete with all fixing arrangement as required including painting-single arm, (Make:- Transrail/Subham/Bajaj] as per direction of EIC (Drawing & design from pole manufacturer should be approved from this end & necessary work as per EIC).
SITC of outdoor type water proof double door Distribution Feeder Pillar box (1200 mmx900 mm x750 mm ) conforming to Indian Standard IS : 5039- 1969 with latest amendments,suitable for use on 3 phase 4 wire, 400/440 Volts 50 Cycles A.C. Supply and shall be suitable to be fabricated as per design & drawing to be approved by EIC. The Enclosure shall provide Degree of protection IP -66 respective Indian standard (IS). [Manufacturer/Fabricator having Test Certificates from CPRI] The body will be fabricated with 3mm thick MS plate, MS angle ( 50X50X5) & MS Flat ( 50X6 ). The top of the box will be fitted with a sloping canopy made out of 3 mm thick sheet steel. It will have double hinged door at the front and back with suitable locking arrangement (Godrej Type ) and provision for manual locking arrangement also. Provision for fixing of CESC meter ,Cut out etc at backside of the feeder pillar must be kept.
a) Incoming - 100A, 415V, TPN SFU with sheet steel enclosure incl. S & F 3 nos. DIN type HRC fuse as per rating---------1No. b) Outgoing - 32A 415V, TPN SFU with sheet steel enclosure incl. S & F 3 nos. DIN type HRC fuse as per rating---------3 Nos. c) Busbar- 4 nos Al Busbar 100A (0.6mtr long each)------1 set. d) Astro mini Time switch [Make-L&T Cat No.- T2DDT7]----1 no. e) Contactor- 415V 70A 3 pole contactor with 230V AC operating coil voltage[Make- Legrand /L & T ] f)Red,Amber, Green LED indication lamp, 240V AC-3 nos. (L&T /Siemens) for system incoming supply on busbar chamber. (g) E.I. Danger Board of suitable size ------- 1 no. (h) Interconnection:-All interconnection between incoming main to Busbar are to be made with suitable size flexible pvc insulated multistranded single core Cu cable and the same between busbar to each outgoing mains and & for metering arrangements are to be made by suitable size of Copper with proper socketing of the end of each wire leads
(j)Earthing Arrangement :-A separate continuous aluminum earth busbar of appropriate size is to be painted at the inside bottom of the panel and run across the full load of the Feeder Pillar Box. All electrical equipment are to be properly earthed with suitable size G.I. strip. (k)The complete Feeder Pillar Box is to be spray painted after required surface treatment by 7 tanks process / sand blasting with 2 coat of red oxide primer & 2 coat of finished paint over dried or powder coating. (l) Installation:- The complete feeder pillar box board is to be installed on suitable brick padestal as directed by the E.I.C. the pillar box has to be installed by grouting the brick foundation after cutting earth pit dimension 3"X2.5"X2' below ground level and 3 ft above ground level ramming the same properly with neat cement finish.
Supply & delivery of BIS approved new generation energy saving environment friendly and long lasting heat resistant ,IP-66 & IK 10 rated 150 W (maximam) LED street light luminaries with pressure die cast aluminium housing with Toughened glass/ PC cover provided with high power LEDs and secondary optics PC/ PMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with builtin 4 KV surge protection and 10KV external SPD with Efficasy≥ 135 lumen/watt , Impact resistance IK 10, CRI >70,CCT ≥5700K. Make:- Wipro Voyage/ Crompton Falcon Pro I/ Philips-Urban edge Plus /Bajaj Hexo J, Driver Mk.-Philips Signify / Wipro / Xitanium/lnventronics, LED Chip mk.-Nichia,Cree,Osram, Lumiled.) as approved by E.I.C as per site requirement.
Fixing only Street Light Fitting with suitable tie clamps and MS plate for mounting on Pole/Tower or similar structure.
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level By ISI-Medium GI pipe as directed by EIC.
Excavation of soil for installation of Earth Electrode and filling & ramming (for soft soil).
Supply & Delivery of XLPE Insulated & Sheathed Armoured Aluminium Conductor cable for Working Voltage up to 1100 Volts of following sizes [Make: Gloster/Polycab/RR Kabel/Mescab/Havells as approved by E.I.C]
(i) 4 Core 10 Sqmm
(ii) 4 Core 25 Sqmm
(iii) 2 core 6 sqmm
Laying of 4 Core 10 sqmm Armoured Aluminium Conductor cables in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per direction by EIC.
Laying of 4 Core 10 sqmm Armoured Aluminium Conductor cables through pole as per direction by EIC.
Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish
From 2.5 sqmm to 35 sqmm at an average depth of 75 mm in floor/pavement/wall etc.
Laying of 4 core 25 sqmm Armoured Aluminium Conductor cables in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed as per direction by EIC. (From near building panel to feeder pillar box)
Laying of 2 core 6 sqmm cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting as per direction of EIC
Supply & laying 1.1 KV grade PVC insulated stranded copper wire through supply & laying polythene pipe for making connection from loop box to street light fittings as per direction by EIC. (make: Finolex/RR Kabel / Havells / Polycab/ Gloster as approved by EIC)
i) 3 x 36/0.3 (1.5 sqmm)
Supplying and fixing compression type gland and finishing the ends of following XLPE / PVC armoured AL. cable (2/4 / 3.5)Core as per GS.
i) 4 Core 25 Sq. mm
ii) 4 Core 10 Sq. mm
iii) 2 core 6 sq mm
Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required. As per direction by EIC.
a) 32 mm dia
b) 50 mm dia
Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for upto 2- core 6 sqmm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.
Supply & Deiivery of LED 90-100W street light luminarie IP 66,made up of pressure die cast aluminium housing withToughened glass/ PC cover provided with high power LEDs and secondary optics PC/PMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with built in 4 KV surge protection and 1OKV extemal SPD with Efficacy>120 lumen/watt, Impact Resistance :- IK 10, CRI >70, CCT>5700K. (Make:- Wipro DOT/Crompton, Raptor Pro/ Bajaj EDGE NXT LED/ PANASONIC BLOOM /Havells Endura SunDown/PHILIPS Urban edge PIus) Driver Mk.- Philips Signify/Wipro/ Xitanium/ Inventronics.LED Chip mk.-Nichia,Cree,Osram, Lumiled.
Supply & Delivery of 150W LED Flood light luminarie IP 66, made up of pressure die cast aluminium housing with Toughened glass/ PC cover provided with high power LEDs and secondary optics PC/ PMMA lens and Silicon filled BIS registered Potted Vibration proof Driver with builtin 4 KV surge protection and 10KV external SPD with Efficacy≥ 135 lumen/watt or better, Impact resistance-IK 10, CRI >70,CCT ≥5700K. Make:- Wipro ALPHA/ Crompton PLUTO NEO/ Philips Tango LED/Bajaj), Driver Mk.- Philips Signify / Wipro/ Xitanium/lnventronics,LED Chip mk.-Nichia,Croe,Oaram, Lumiled.
Fixing only outdoor / street light type light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Supplying and fixing 2 way MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting,connection & provision for earthing attachment as per direction of EIC (for installation of DP MCB for controlling of compound light fixed on building wall).
Supplying and fixing 240 V 10-32 A DP MCB of Breaking Capacity 10 kA & C Characteristics on din rail of existing DBs and necessary connection.(Make-Legrand/L&T/Siemens) (for controlling of compound light fixed on building wall).
Fixing only outdoor / street light type light fitting or MV light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S&F 40 mm GI pipe (ISI-Medium) quality 1.5 mts. average length having suitable bend S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages
a) No. 6 SWG Solid GI wire
Connecting the equipments body to earth busbar including S&F 20 mm x 3 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles as required and connection to equipments incl. drilling holes, with bolts, nuts, washers etc.
Supply & fixing Timer Control unit for compound light in SS double door (lP-43) 12way SPNDB Box [Make-L&T /Siemens/ Legrand/ ABB as approved by E.l.C [with all accessories on with fastners, nuts etc.] a) 12-way SPNDB or Timer DB -1 no. (b) 40 A DPMCB Isolator -1 no. c) 25 A 2 Pole Power Contactor -1 no d) Daily & weekly programmable digital time switch--1 no. e) LED lndicator lamp-2 Set(1- Red & 1-Green) f) 32 A Barrier type Terminal---1 No. (g) Centre off 2-way toggle switch---1 no. All control circuit wiring would be made by 2x4 + 1x2.5 sqmm FRLS stranded Cu wire(Make:- Gloster/Havells/Polycab/RR Kabel) of suitable length maintaining colour code incl. taping, socketing to complete the work.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.23 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_2399767.xls
BOQ • 0.42 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .