CWE (ARMY) SECUNDERABAD
CWE (ARMY) MUDFORT COMPLEX, SECUNDERABAD- 500003
SPECIAL REPAIRS TO SEWAGE SYSTEM AT 2 TRG BN OF AOC CENTRE UNDER GE (SOUTH) SECUNDERABAD.
2020_MES_347962_1
CWE(S)/SOUTH/TOKEN-09 OF 2020-2021
Open Tender
Civil Works
Item Rate
180 days
Secunderabad
As per NIT
6 documents required · 6 mandatory
₹500
GE (South) Secunderabad
₹59,000
Yes
10 Sept 2020
28 May 2020
3 Jul 2020
28 May 2020
26 Jun 2020
13 Jun 2020
Amount
Excavation in trenches not exc. 1.5 meter wide and n.exc. 1.5 meter in depth for foundations of man holes etc., n.exc. 10sqm on plan and getting out in hard/dense soil complete all as specified and as directed
All as per item No 1.00 abvoe but trenches exceeding 1.5 meter and not exceeding 3 meter in depth complete all as specifed and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each in soils all as specified and as directed.
Removing excavated soils not exc 50 M and depositing where directed at a level not exc1.5 M above the starting point complete all as specified and as directed.
Demolition and breaking up drain pipes of size 100mm bore (salt glazed ware, AC or reinforced concrete) set in cement mortar including concert bedding and hanching complete all as specified and directed
All as per Item No 5.00 abvoe but size 150 mm bore complete all as specified and directed
All as per Item No 5.00 abvoe but size 200 mm bore complete all as specified and directed
M & L Concrete bed to drain pipes of 100mm dia bore in PCC 1:4:8 type D-2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M & L Concrete bed to drain pipes of 150mm dia bore in PCC 1:4:8 type D-2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
M & L Concrete bed to drain pipes of 200mm dia bore in PCC 1:4:8 type D-2 using 40mm graded stone aggregate including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed.
S & F salt glazed stoneware drain pipe (SGW) grade 'A' laid in trenches and jointed as specified of internal dia of pipe 100mm all as specified and as directed.
All as per Item No 11.00 abvoe but size 150 mm bore complete all as specified and directed
All as per Item No 11.00 abvoe but size 200 mm bore complete all as specified and directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 100mm bore SWG pipe complete all as specified and directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm bore SWG pipe complete all as specified and directed
Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting ou existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 200mm bore SWG pipe complete all as specified and directed
All as per item No 15.00 above but for removing existing branch drain, making good to walling and rendering, cutting out branch channel and making good benchings for 150mm dia SWG pipe complete all as specified and directed
All as per item No 16.00 above but for removing existing branch drain, making good to walling and rendering, cutting out branch channel and making good benchings for 200mm dia SWG pipe complete all as specified and directed
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlal facings, dressed stonework and precast concrete articles complete all as specfied and directed
Demolition of cement concrete (reinforced) of any description and any position not otherwise specifically provided.complete all as specified and as directed
M&L Brick work with subclass B bricks, straight or curved on plan exc 6m mean redius built in CM 1:6 complete all as specified and directed.
All as per Item No 21.00 abvoe but except bricks complete all as specified and directed. Note : Bricks shall be obtained from demolition item
M&L precast reinforced cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in landings, cover slabs (for manhole etc) including necessary form work and set in CM (1:4). Note:- reinforcement shall be measured and paid separate under respective items
Taking down cement plaster on brick or stone masonry wall etc including racking out joints hacking for key, scrubbing down with water etc as in internal and external suraces of manholes, septic tank, ailter bed etc including removing of debrie complete all as specified and directed
Supply only integral water proofing compound complete all as specified.
M&L Rendering 15mm thick in CM 1:4 on fair faces of brick/concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed.
Pumping out sewage water / sludges from Septic Tanks / Soak Wells / Sumps etc., of any size / dia by means of mechanical operated equipment / trolley mounted Browsers with taking all precautionary measures and removing sludges / water out side from the MD land (working in foul condition) complete all as specified and directed.
Cleaning and de-sludging of existing septic tanks/ deep manholes up to 3 metre deep including taking out sludge in any form alongwith all other foreign materials by mechanical equipment or manually or by way of other suitable means including removal of sludge and other foreign materials out side the MD land by any means complete (working in foul condition) all as specified and directed
All as per Item No 28.00 above but septic tanks/deep manholes above 3 meter to 6 meter deep complete all as specified and directed.
Removal of filter media including sludge from filter bed/soak well as deposited and barried in ground including excavation as required except re use material in foul position from filter bed etc any depth or width all as specified and getting out complete all as specified and directed
M&L loose filling with broken stone aggregate of gauge 40 to 80mm as filter media in filter beds, soak pits etc all as specified and directed
All as per Item No 32.00 above but 20mm gauge broken stone aggregate complete all as specified and directed.
M&L for cleaning of shurbs/ bushes arround the septic tank, filter bed, manholes and along the sewage line etc all as specfied and directed
Demolition and breaking up drain pipes ( AC or Reinforced concrete) set in cement mortar from floors, walls complete all as specified and diercted
S&F 110 mm PVC (SWR) pipes single socket in any length with rubber ring joints fixed to wall complete all as specified and directed.
All as per Item No 35.00 above but 75mm complete all as specified and directed.
S&F 110 mm PVC (SWR) bends any redius complete all as specified and directed.
S&F 75 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
S&F 110 mm PVC (SWR) bends any redius with access door complete all as specified and directed.
Supply and fixing PVC (SWR) junction single 'T' 110 mm bore equal or unequal complete all as specified and as directed.
Supply and fixing PVC (SWR) junction double 'T' 110 mm bore equal or unequal with access door complete all as specified and as directed.
S & F 110mm dia PVC (SWR) vent cowl complete all specified and as directed.
S & F 75mm dia PVC (SWR) vent cowl complete all specified and as directed.
S & F 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
S&F for PVC (SWR) gully trap of 125/110 mm dia set and jointing with solvent cement complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking, bending, sprillay for hooping for columns, hooking ends and binding with and including MS wire (annealled) not less than 0.90 mm dia complete all as specified and as directed.
All as per Item No 47.00 above but 6 to 8mm bore complete all as specified and directed
S&F in repair Vitreous china squatting pan, Orissa pattern of size 580 x 440mm, white complete with integral foot rests and PVC low level flushing cistern of 10 Ltr capacity and PVC flush pipe and including provn of lime concrete bedding including CI 'P' trap 100mm complete all as specified and directed.
S&F in repair vitreous china white wash hand basin (flat back or angle back type) size 550x400mm white including brackets, pedestal, wast fittings brass chromium plated, CP waste cupling, 32mm dia, waste pipe, PVC connection 15 mm bore with PTMT nuts of length complete all as specified and directed.
S&F cast iron branch piece single 100mm dia (equal or unequal), ordinary or inverted or with parellel branches complete all as specified and directed
S & F reinforced concrete pipes class NP3 laid and jointed complete with coller of 300mm bore complete all as specifed and directed
M & L concrete bed to drain pipes including packing under, and completely surrounding of pipes after they are laid and tested 300mm long complete all as specifed and directed
M & L PCC 1:2;4 type B1 (using 20mm graded stone aggregate) as in copings, kneeles apex stone, channel and the like including weathering, slightly roundd chamfered etc complete all as specified and directed
Dismantling floor hearth or wall tiling including cement mortar bedding but not backing, complete all as directed.
S & F Non skid coloured cermic tiles 7 to 8mm thick (square or rectangular) area of each tile exc. 0.06 sqm but n.exc 0.11 sqm in floors etc set and jointed in neat cement slurry and painted in white cemnent to match incuding 15mm thock screed bed or bedding layer of mortar in CM 1:6 for laying floor finishes, complete all as specified and as directed
S & F glazed ceramic Coloured tiles 300 x 200 mm thick in veritical surfaces set and jointed in neat cement slurry and painted in white cement to match including 10mm thick backing coat as in CM 1:4, complete all as specified and as directed
M & L for construction of 200 users septic tank in hard/dense soil, foundation in PCC 1;2;4 brick work in CM 1:4 RCC cover slab in M-25 including RCC pre cast manhole cover with angle iron frame vent saft and sludge chamber etc with ref to Drg No. TD/STR/8 sheet No. 3/3 CE(Fy) Hyd complete all as specified and as directed
M & L for construction of soakage well of size 3.0mtr dia and 4.5 mtr deep, excavation in hard/dense soil foundation in PCC (1:3:6), fly ash bricks masonry in CM 1:4 with honey coiming and PCC bend, including intersepting chamber, RCC cover slab in M-25 and filling with brick bats with reference to Drg No. HTD/381 Sheet No. 1/1 CE(Fy) Hyd complete all as specified and as directed
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .