| 1.00Location & pin pointing of cable fault exposing the same in the underground 33KV, 11KV and LT cable cable including digging of trench up to the depth of cable, high pressure testing of cable and proper levelling of pit after removal of fault of the faulty cable as per site conditions and providing proper working space inside the pit for bable jointing. (All operational charges on account of expenses on required man power, Vehicle, Driver and cost of fuel for movement and operation of fault locator machine shall be borne by the contractor. | |||||
| 2.00Fault attending of 11KV feeder | |||||
| 2.10 | (a) High Pressure test for 11KV cable & cable found healthy | 230 | Nos. | 5,425 ₹12.5 L | 5,150 ₹11.8 L |
| 2.30 | (b) High Pressure test for 11KV cable (found underground cable fault) pin pointing of fault. Digging filling & leveling of surface and again high-pressure test for checking healthiness of the cable | 200 | Nos. | 8,390 ₹16.8 L | 8,150 ₹16.3 L |
| 2.40 | (c) High Pressure test for 11KV Cable (found fault at outdoor/indoor/insulator) and again high-pressure test for checking healthiness of the cable. | 50 | Nos. | 6,425 ₹3.2 L | 6,150 ₹3.1 L |
| 3.00Fault attending of 33KV Feeder | |||||
| 3.10 | (a) High Pressure test for 33KV cable & cable found healthy | 230 | Nos. | 5,875 ₹13.5 L | 5,650 ₹13.0 L |
| 3.20 | (b) High Pressure test for 33KV cable (found underground cable fault) pin pointing of fault. Digging filling & leveling of surface and again high-pressure test for checking healthiness of the cable | 300 | Nos. | 11,490 ₹34.5 L | 11,250 ₹33.8 L |
| 3.30 | (c) High Pressure test for 33KV Cable (found fault at outdoor/indoor/insulator) and again high-pressure test for checking healthiness of the cable. | 50 | Nos. | 6,425 ₹3.2 L | 6,250 ₹3.1 L |
| 4.00 | Digging of Trench for laying of 11KV cable loop (Cable shall be provided by the department) | 1,000 | Nos. | 525 ₹5.3 L | 445 ₹4.5 L |
Tender Value
Refer Docs
EMD Value
₹1.1 L
Closing Date
2 Mar 2026, 4:00 pmClosed
SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
SUPERINTENDING ENGINEER, (TECHNICAL), AMAUSI ZONE
46/SE(T)/AMAUSI ZONE/2025-26
2026_MVVNL_1116160_1
46/SE(T)AMAUSI ZONE/2025-26
Open Tender
Electrical Works
365 days
LUCKNOW
AS PER TENDER DOCUMENTS
2 documents required · 2 mandatory
₹5,900
E.E., EDD, CESS-Ist, LESA, Lucknow
₹1.1 L
1 Apr 2026
16 Feb 2026
3 Mar 2026
16 Feb 2026
2 Mar 2026
16 Feb 2026
Location & pin pointing of cable fault exposing the same in the underground 33KV, 11KV and LT cable cable including digging of trench up to the depth of cable, high pressure testing of cable and proper levelling of pit after removal of fault of the faulty cable as per site conditions and providing proper working space inside the pit for bable jointing. (All operational charges on account of expenses on required man power, Vehicle, Driver and cost of fuel for movement and operation of fault locator machine shall be borne by the contractor.
Fault attending of 11KV feeder
(a) High Pressure test for 11KV cable & cable found healthy
(b) High Pressure test for 11KV cable (found underground cable fault) pin pointing of fault. Digging filling & leveling of surface and again high-pressure test for checking healthiness of the cable
(c) High Pressure test for 11KV Cable (found fault at outdoor/indoor/insulator) and again high-pressure test for checking healthiness of the cable.
Fault attending of 33KV Feeder
(a) High Pressure test for 33KV cable & cable found healthy
(b) High Pressure test for 33KV cable (found underground cable fault) pin pointing of fault. Digging filling & leveling of surface and again high-pressure test for checking healthiness of the cable
(c) High Pressure test for 33KV Cable (found fault at outdoor/indoor/insulator) and again high-pressure test for checking healthiness of the cable.
Digging of Trench for laying of 11KV cable loop (Cable shall be provided by the department)
Digging of Trench for laying of 33KV cable loop (Cable shall be provided by the department)
Location and pin pointing of cable fault exposing the same into the underground LT Cable including digging of trench up to the depth of cable cutting the fault cable and sealing of the cable.
Supply of various size S/th & O/D jointing kit in case of unavailability in store Lucknow.
(a) Outdoor Jointing Kit for 33KV 3x300Sqmm
(b) S/Th jointing Kit for 33KV 3x300Sqmm
(c) Outdoor Jointing Kit for 11KV 3x185Sqmm
(d) S/Th jointing Kit for 11KV 3x185Sqmm
(e) Outdoor Jointing Kit for 11KV 3x240Sqmm
(f) S/Th jointing Kit for 11KV 3x240Sqmm
G.S.T. Extra as per rules.
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.77 MB
T46FORM.pdf
Tender Documents • 1.63 MB
BOQ_2073643.xls
BOQ • 0.24 MB
Download all tender documents and submit your bid