| 1 | Comprehensive maintenance of 7TR Package AC Plant | Comprehensive maintenance of following electro-mechanical services situated in the above buildings, as per specifications, conditions of contract and as per the details given in relevant sections by deploying specialized manpower and supplying and fixing required spares, arranging tools and plants etc, to keep the services operational up to the required standard complete as required.
7 TR Package AC plant, PAC at 1st. Floor 10 jobs per month, Note 0 2 Nos., at Contai TE and 8 Nos At Inda TE.
interconnection lead / cord including replacement of faulty spares, charging of refrigerant, repairing / rewinding of cooling motor and blower motor, replacement of faulty compressor, cleaning of filter, cooling coil and condenser coil etc. for smooth operation of the AC units complete as reqd.
a) 1.5 TR capacity Split / Window AC units (8 jobs/month ) ( At TE Bldg,Hijli) | 120 | Job | [email protected] | 365 |
| 2 | Comprehensive maintenance of 1.5 TR capacity Split, Window AC units | Comprehensive maintenance of following capacity WAC, Split AC unit and its associated power feeding arrangement comprising of MCB, Industrial Plug and socket, interconnection lead, cord including replacement of faulty spares, charging of refrigerant, repairing, rewinding of cooling motor and blower motor, replacement of faulty compressor, cleaning of filter, cooling coil and condenser coil etc. for smooth operation of the AC units complete as reqd. a 1.5 TR capacity Split, Window AC units 17 jobs per month, Note 12Nos at TE Bldg Inda TE and 5 nos at TE Bldg Contai | 204 | Job | [email protected] | 365 |
| 3 | Comprehensive maintenance of AFD at CONTAI TE. | Comprehensive maintenance of AFD system of the entire building (System of different floors) complete with replacement of faulty items as detectors and repairing of other components such as Main control panel, Local control panel, Manual call point, Hooters etc. as reqd At Contai TE | 12 | Month | [email protected] | 365 |
| 4 | Comprehensive maintenance of AFD at INDA TE. | Comprehensive maintenance of AFD system of the entire building, System of different floors, complete with replacement of faulty items as detectors and repairing of other components such as Main control panel, Local control panel, Manual call point, Hooters etc. as reqd, At Inda TE | 12 | Month | [email protected] | 365 |
| 5 | Replacement of faulty 36,40 watt fl. Tubes with 20watt retrofit, new LED light. | Replacement of faulty 36,40 watt fl. Tubes with 20watt retrofit, new LED light. | 42 | Nos | [email protected] | 365 |
| 6 | Rewinding of faulty ceiling fan 1200,1400 mm sweep motor with good quality copper wire. | Rewinding of faulty ceiling fan 1200, 1400 mm sweep motor with good quality copper wire. | 11 | Nos | [email protected] | 365 |
| 7 | Replacement of existing faulty Compound light lamps with 30 watt LED lamp. | Replacement of existing faulty Compound light lamps with 30 watt LED lamp. | 2 | Nos | [email protected] | 365 |
| 8 | Operation of Electromechanical services at Inda TE and staff Qtr Complex and Contai TE | Operation of Electromechanical services at Inda TE and staff Qtr Complex and Contai TE as per specification and details of services, Inventory etc. attached. | 12 | Month | [email protected] | 365 |