Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹4.4 LAccepted-AOC | ₹4.4 L | L-1 | Accepted-AOC IST LOWEST |
| 2 | L-2₹4.5 LRejected-AOC R O VILL GATROL PO DABLA TEH GHUMARWIN BILASPUR 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | ₹4.5 L | L-2 | Rejected-AOC 2ND LOWEST |
| 3 | L-3₹4.5 LRejected-AOC VILL FAGOG P O BALOH TEHSIL JHANDUTTA DISTT BILASPUR HP | ₹4.5 L | L-3 | Rejected-AOC 3RD LOWEST |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹5.6 L
EMD Value
₹11,150
Closing Date
7 Apr 2026, 5:00 pmClosed
EXECUTIVE ENGINEER ELECT HIMUDA
EXECUTIVE ENGINEER ELECT HIMUDA KASUMPTI SHIMLA-9
Construction of science Lab Computer lab AND 2Nos Toilets at GSSS Darlaghat Distt Solan HP Libarary and Computer lab at GSSS Kandaghat, Distt Solan HP Laboratary and 4 Nos Toilets at GSSS G Karsog Distt Mandi HP and GSSS Dhami Pdg E I
2026_HIMUD_132672_1
HIMUDA PP E W 7 2025 2317-27 dt 27.03.2026
Open Tender
Electrical Works
195 days
SOLAN
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Yes
₹11,150
Yes
2 Jun 2026
28 Mar 2026
8 Apr 2026
28 Mar 2026
7 Apr 2026
28 Mar 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable i/c removal of old wiring as required. and approved by the Engineer- in- Charge. Group C. | |||||
| 2Wiring for power plug with 2x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing i/c removal of old wiring as required and approved by the Engineer- in- Charge. | |||||
| 3Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed pvc conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. and approved by the Engineer- in- Charge. a) 2x1.5 Sq. mm. | |||||
| 3.1 | 2x 6 Sq. mm.. | - | Per Rmt | - | - |
| 4Supplying and fixing of following sizes of PVC conduit along with the accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required: and approved by the Engineer- in- Charge. a) 25 mm Dia | |||||
| 5Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. and approved by the Engineer- in- Charge. | |||||
| 6Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required and approved by the Engineer- in- Charge. | |||||
| 7Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required: and approved by the Engineer- in- Charge- Single pole. Cat-A. | |||||
| 8Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. and approved by the Engineer- in- Charge. 63 Amps. Cat-A. | |||||
| 9Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wireset, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- and approved by the Engineer- in- Charge. Double door-4 way | |||||
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
NITDARLAGHAT.pdf
Tender Documents • 0.55 MB
Form6and8.pdf
Tender Documents • 2.55 MB
newspecification.pdf
Tender Documents • 0.13 MB
UNDERTAKING.pdf
Tender Documents • 0.29 MB
BOQ_196191.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid